PERFORMANCE SPECIFICATION. Table 1 summarizes the projected output from the stack module at rated load. * * Confidential information has been omitted and filed separately with the Securities and Exchange Commission pursuant to a request for Confidential Treatment. * * * 3.6 Stack Module Life * *
PERFORMANCE SPECIFICATION. The contractor’s proposal shall, together with the performance specification, form the contract requirements for the G4 Buffalo A2 vehicles. The contractor’s proposal shall meet or exceed all requirements in the Performance Specifications with the specific exception of Cooling system paragraph 3.4.2.a “...Maintain the specified component operating temperatures within the specified limits while operating continuously at full load and 0.6 tractive effort to gross vehicle weight ratio (TE/GVW) while under the maximum temperatures conditions specified herein.” and paragraph 4.9.4 “The cooling system shall be tested for maintaining the specified component operating temperatures within the specified limits while operating continuously at full load and 0.6 tractive effort...” The US Army has accepted performance at 0.5 tractive effort. G4 will also accept 0.5 tractive effort. In addition, Tires and Wheels paragraph 3.11.4 states in part “...A spare tire and wheel assembly identical to those provided on the axles shall be furnished, and provided with the vehicle.” In this case, the tires shall be provided as spares and not part of the vehicle shipment. The following specification paragraphs are also modified as follows:
· 3.1 First Article (p. 6)-Delete · Testing conducted by TACOM
PERFORMANCE SPECIFICATION. A description of the desired results or performance of a product, material, assembly, procedure, or a piece of equipment with criteria for identifying the standard.
PERFORMANCE SPECIFICATION. 3.10.1 A full and detailed functionality description of the system shall be provided by the Service Provider.
3.10.2 The Service Provider shall not focus on the provisioning of computer hardware since Swellendam Local Municipality will use existing infrastructure where possible. For this reason, it is also imperative that the Service Provider should be quite clear on where Swellendam Local Municipality’s hardware and/or networks lack the capability and/or capacity to function properly with the system proposed by the Service Provider and the Service Provider should indicate the cost of additional or replacement infrastructure.
3.10.3 A detailed graphical drawing depicting the proposed network and system layout must be drafted to clarify and indicate solution functionality. Should changes be required, full specifications and pricing must be provided.
3.10.4 The system provided by the Service Provider should ensure that different servers are utilized for different applications such as:
3.10.4.1 Database functions
3.10.4.2 Management applications
PERFORMANCE SPECIFICATION. The CK shall meet all requirements in the Performance Specification for the Containerized Kitchen, MIL-PRF-32026 (Attachment 1), with the following exceptions:
1.a When the CK is ordered Camouflage Green, 6 each, Fuel Cans, green, NSN 7240-01-337-5269 shall be provided. In addition, item 3 of Table III, can water, plastic, 5-gallon, sand, NSN 7240-00-089-3827 shall be replaced with, can, water, plastic, 5-gallon, green, NSN 7240-01-506-4426 in the same quantity.
1.b When the CK is ordered Tan, 6 each, Fuel Cans, tan, NSN 7240-01-337-5268, shall be provided. In addition, items 1 and 11 of Table III shall be replaced with, Beverage dispenser, 5-gallon, sand, NSN 7310-01-093-7371 and, Insulated food container, sand, NSN 7360-01-452-0686, respectively in the same quantities.
1.c The first sentence of paragraph 3.3.1.5 of the performance specification shall be modified to read: The CK shall have no less than one 110 volt, 15 amp, duplex outlet that is easily accessible in the mechanical room and no less than two 110 volt 15 amp outlets, which are easily accessible from the meal preparation area.
PERFORMANCE SPECIFICATION. Pursuant to the Framework Purchase Agreement, based on the Client's orders, the Supplier undertakes to deliver the following goods to the Client at the prices stated below: Xofigo 1100 kBq/ml solution for injection, sol inj 1x6 ml (sol.inj.gla.) containing 000Xx, XXXX code: 8112A
PERFORMANCE SPECIFICATION. The System shall be capable of automatically determining the terminal location of any tracked pitch with a Root Mean Square (RMS) error of no more than 0.5 inch under reasonable operating conditions. The terminal location shall be defined as the point where the pitch path crosses the plane determined as the back of the strike zone by the location of the tip of home plate.
PERFORMANCE SPECIFICATION. 3.4.1. When the heel of each foot is impacted at 6.7 ± 0,1 m/s in accordance with paragraph 3.3., the maximum impactor acceleration shall be 3.3 ± 0.5 kN. Figure 1 Upper foot impact test - Test set-up specifications Figure 2 Lower foot impact test (without shoe) - Test set-up specifications Figure 3 Lower foot impact test (with shoe) - Test set-up specifications Figure 4 Pendulum impactor This annex describes test procedures to demonstrate compliance to the electrical safety requirements of paragraph 5.2.8. For example, megohmmeter or oscilloscope measurements are an appropriate alternative to the procedure described below for measuring isolation resistance. In this case it may be necessary to deactivate the on-board isolation resistance monitoring system. Before the vehicle impact test conducted, the high voltage bus voltage (Vb) (see figure 1) shall be measured and recorded to confirm that it is within the operating voltage of the vehicle as specified by the vehicle manufacturer.
PERFORMANCE SPECIFICATION. ================================================================== By MCIT 8/3/96 Network Design Engineering Final Xxxxx Jabbarrezned [_______________] Sr. Engineer Approval / Date /s/ Xxxxxxx Xxxxxx, /s/ Xxxxxx X. Xxxxxxx, --------------------------------- ---------------------------- Xxxxxxx Xxxxxx, Manager Xxxxxx X. Xxxxxxx, Senior Manager ------------- MCI PROPRIETARY ------------- MCI Telecommunications Corporation Network Integration & Standares 0000 X. Xxxxxxx Xx. Xxxxxxxxxx, Xxxxx 00000 -------------------------------------------------------------------------------- ================================================================================ [_______________] ======================================================================= INTEREXCHANGE CARRIER ----------------------------- PERFORMANCE SPECIFICATION =======================================================================
PERFORMANCE SPECIFICATION. Table 1 summarizes the projected output from the stack module at rated load. This table shows the DC output from the stack module, which is comprised of the output from four DFC stacks connected as two parallel strings, each with two series-connected stacks. * This performance is for a powerplant operating at sea level atmospheric pressure. Module DC voltage will reduce by 2 volts for every 1000 feet of elevation above sea level due to reduced cell electrochemical performance at lower pressure. In addition to this module power output decrease, there will also be BOP impacts on power and efficiency due to elevation and ambient temperature, depending on the BOP design. This performance requires the proper supply of process gasses to the module. Table 2 shows the process flows required for rated operation. Anode Inlet, Natural Gas Fuel Anode Inlet, Digester Gas Fuel Air Flow (at module inlet, after air blower, combination of primary and secondary air) Temperature, deg F * * * Volume Flow, SCFM * * * Molar Flow, lbmol/hour * * * Mass Flow, lb/h * * * Components lb-mole/hr mole % lb-mole/hr mole % lb-mole/hr mole % Hydrogen * * * * * * Methane * * * * * * Carbon Monoxide * * * * * * Carbon Dioxide * * * * * * Water * * * * * * Nitrogen * * * * * * Oxygen * * * * * * Total * * * * * * * Contaminant Air limit, ppb Fuel limit, ppb Total sulfur compounds * * Total halogens, halides, or hypochlorite * * Particulates * * Siloxanes * * Metals * * Mercury * * Lead * * Selenium * * Cadmium * * Arsenic * * Vanadium * * Tin * * Potassium * * Sodium * * Zinc * * Barium * * Iron * * Chromium * * *