Physical Collocation. (a) If space for Physical Collocation is immediately available at the time of Requesting Carrier’s Collo Order, Ameritech shall include in its Collo Response to Requesting Carrier notice of such immediate availability.
(b) If Requesting Carrier’s requested Physical Collocation space is available, Ameritech and Requesting Carrier shall have an initial walk-through of such space within the interval specified in the Implementation Plan. Absent Ameritech’s written consent, Requesting Carrier must have at least one (1) authorized employee (i.e., in addition to any authorized vendor) at such walk- through. If during the initial walk-through, Requesting Carrier wishes to modify or change its Collo Request, Requesting Carrier must sign or initial any such modifications or changes and provide Ameritech a change order reflecting same within five (5) Business Days of such initial walk-through. If a change or modification is noted at the initial walk-through, Ameritech shall have no obligation to commence work on Requesting Carrier’s Collocation space until it receives a change order to amend the Collo Request or written confirmation that Requesting Carrier does not wish to pursue such change or modification. Failure to provide Ameritech the change order or written confirmation within the foregoing five (5) Business Day period shall be deemed a Requesting Carrier Delaying Event for the period between the expiration of such five (5) day period and the date of actual receipt by Ameritech.
(c) Ameritech shall deliver to Requesting Carrier the requested space on or before the later of (i) one hundred twenty (120) days from Ameritech’s receipt of Requesting Carrier’s Collo Order, (ii) ninety (90) days from the date of the initial walk-through and (iii) such other reasonable date that the Parties may agree upon if it is not feasible for Ameritech to deliver to Requesting Carrier such space within the foregoing intervals (such date of delivery referred to as the “Delivery Date”).
(d) Physical Collocation space ordered by Requesting Carrier will be made available to Requesting Carrier by Ameritech as more fully described in Section 1 of Schedule 12.12.
(e) Ameritech may begin billing recurring charges for the Collocated space on the date such space is made available for occupancy (the “Occupancy Date”). Requesting Carrier shall vacate the Collocated space if either (i) Requesting Carrier (or one of its Resident Collocators, if applicable) fails to install within ninety (90) d...
Physical Collocation. CLEC is responsible for the maintenance and repair of its equipment located within CLEC's leased space.
Physical Collocation. Ameritech shall provide to Requesting Carrier Physical Collocation on its Premises for equipment necessary for Interconnection (pursuant to Article III) or for access to unbundled Network Elements (pursuant to Article IX), except that Ameritech will provide for Virtual Collocation of such equipment if Ameritech demonstrates to the Commission that Physical Collocation is not practical for technical reasons or because of space limitations, as provided in Section 251(c)(6) of the Act. Ameritech shall provide Requesting Carrier Collocation only for the purpose of Interconnection or access to Ameritech's unbundled Network Elements and for no other purpose other than as specifically provided by the Act, the Commission or the FCC.
Physical Collocation. CLEC shall provide to SBC-AMERITECH Physical Collocation in the LEC Access Equipment Room in CLEC’s Wire Centers for equipment necessary for Interconnection (pursuant to Article III). CLEC shall provide SBC- AMERITECH Collocation only for the purpose of such Interconnection.
Physical Collocation. GTE shall provide to Nextel physical collocation of equipment pursuant to 47 CFR § 51.323 necessary for interconnection, provided that GTE may provide virtual collocation in place of physical collocation, or in some cases deny a particular collocation request entirely, if GTE demonstrates that physical collocation, or perhaps even virtual collocation, is not practical because of technical reasons or space limitations, as provided in Section 251(c)(6) of the Act. GTE will work with Nextel to install collocation arrangements within 120 calendar days absent extenuating circumstances. GTE will provide such collocation for purposes of interconnection pursuant to the terms and conditions in the applicable federal and state EIS tariffs.
Physical Collocation. 4.1.1 When MCIm provides its own facilities or uses the facilities of a 3rd Party to an AT&T ILLINOIS Tandem or End Office and wishes to place its own transport terminating equipment at that location, MCIm may interconnect using the provisions of Physical Collocation as set forth in Appendix Collocation.
Physical Collocation. (a) If space for Physical Collocation is immediately available at the time of CLEC's request, SBC-AMERITECH shall include in its notice to CLEC: (i) the space to be provided, and (ii) whether SBC- AMERITECH can deliver the space to CLEC by the date set forth in Section 12.15.2(d).
(b) At CLEC’s request, SBC-AMERITECH will make cageless collocation available to CLEC in single-bay (10 square feet) or single cabinet (18 square feet) increments. A cageless collocation is one in which CLEC collocates in any unused space that is conditioned to house its equipment. CLEC is not required to construct any enclosure of its equipment. CLEC may locate equipment at any location in the Central Office, up to SBC-AMERITECH’s last unreserved bay space in that central office. In the case of Remote Terminal Cabinet, Controlled Environment Vault or Hut cageless collocation will be offered in increments of one (1) shelf.
(c) If CLEC's requested Physical Collocation space is available, SBC- AMERITECH and CLEC shall have an initial walkthrough of such space within ten (10) Business Days after SBC-AMERITECH's receipt of CLEC's Initial COBO Payment. SBC-AMERITECH shall, within ten (10) Business Days after such initial walkthrough, provide documentation submitted to and received from contractors for any work being done on behalf of CLEC that will be billed as extraordinary expenses and provide for a parallel installation sequence.
(d) SBC-AMERITECH shall deliver to CLEC the requested space on or before the later of: (i) ninety (90) days from SBC-AMERITECH's receipt of CLEC's Initial COBO Payment, where applicable (as provided on Schedule 12.12) for Caged, Shared Cage and Cageless space in Active (conditioned) Central Office space, (ii) one hundred and fifty (150) days from SBC-AMERITECH’s receipt of CLEC Initial COBO Payment where applicable (as provided on Schedule 12.12) for Caged, Shared Cage and Cageless space in Inactive (non- conditioned) Central Office space, or (iii) such other reasonable date that the Parties may agree upon (such date of delivery referred to as the “Delivery Date”).
(e) SBC-AMERITECH will provide reduced intervals to CLEC where CLEC has existing collocation space and CLEC requests different interconnection arrangements in that existing space. Collocation arrangements shall be provided pursuant to Schedule 12.15.2.
(f) Physical Collocation space ordered by CLEC will be made available to CLEC by SBC-AMERITECH as more fully described in Schedule 12.16.
(g) If ...
Physical Collocation. 31.7.2.1 If additional space for Physical Collocation is immediately available at the time of SBC-AMERITECH’s request, CLEC shall include in its notice to SBC- AMERITECH: (i) the space to be provided, and (ii) whether CLEC can deliver the space to SBC-AMERITECH by the date set forth in Section 31.7.2.3.
31.7.2.2 If SBC-AMERITECH's requested Physical Collocation space is available, SBC-AMERITECH and CLEC shall have an initial walkthrough of such space within ten (10) Business Days after CLEC confirms that the requested space is available.
31.7.2.3 CLEC shall deliver to SBC-AMERITECH the requested space on or before the later of: (i) one hundred twenty (120) days from CLEC's receipt of SBC- AMERITECH's request for Collocation, or (ii) such other reasonable date that the Parties may agree upon if it is not feasible for CLEC to deliver to SBC-AMERITECH such space within the foregoing intervals (such date of delivery referred to as the ("Delivery Date").
31.7.2.4 Physical Collocation will be subject to the additional rules and regulations set forth in Schedule 31.7.
31.7.2.5 After completion of construction, CLEC and SBC- AMERITECH will complete an acceptance walkthrough of all Collocated space requested from CLEC. Exceptions that are noted during this acceptance walkthrough shall be corrected by CLEC within thirty (30) days after the walkthrough. CLEC shall conduct a root cause analysis of all exceptions identified. The correction of these exceptions shall be at CLEC's expense, subject to any change orders requested by SBC-AMERITECH.
31.7.2.6 SBC-AMERITECH shall also be entitled to credits for delays by CLEC in provisioning space for Collocation, and for the inability of SBC- AMERITECH to use equipment located in space provided for Collocation as a result of the failure by CLEC to comply with its obligations under this Agreement, pursuant to terms and conditions agreed upon by the Implementation Team.
Physical Collocation. GTE shall provide to Centennial physical collocation of equipment necessary for interconnection or for access to unbundled network elements, provided that GTE may provide virtual collocation in place of physical collocation, or in some cases deny a particular collocation request entirely, if GTE demonstrates that physical collocation, or perhaps even virtual collocation, is not practical because of technical reasons or space limitations, as provided in Section 251(c)(6) of the Act. GTE will provide such collocation for purposes of interconnection or access to unbundled network elements pursuant to the terms and conditions in the applicable GTE federal and state collocation tariffs.
Physical Collocation. CBT shall provide to Intermedia Physical Collocation on its Premises for equipment necessary for Interconnection (pursuant to Article III) or for access to unbundled Network Elements (pursuant to Article IX), except that CBT will provide for Virtual Collocation of such equipment if CBT demonstrates to the Commission that Physical Collocation is not practical for technical reasons or because of space limitations, as provided in Section 251(c)(6) of the Act. CBT shall provide Intermedia Collocation only for the purpose of Interconnection or access to CBT's Network Elements.