Power System Particulars; Sample Clauses

Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: Normal Voltage 415V 11KV 33KV Maximum Voltage 500V 12 KV 36KV No. Of phases 3 3 3 System frequency (Hz) 50 50 50 No. of wires 5 3 3 Fault level (MVA) 25 350 1500 Fault Current / Duration * * 25 kA / 3s Earth Fault Current / Duration * 3 kA / 3 s 3 kA / 3 s Neutral point Earthing Solid Resistance Resistance Conductor arrangement Vertical Horizontal Horizontal
AutoNDA by SimpleDocs
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: Table 6 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV 3 No. Of phases 3 3 3 4 System frequency (Hz) 50 50 50 5 No. of wires 5 3 3 6 Fault level (MVA) 25 350 1500 7 Fault Current / Duration 120KA/3S * 25 kA / 3s 8 Earth Fault Current / Duration * 3 kA / 3s 3 kA / 3s 9 Neutral point Earthing Solid Resistance Resistance 10 Conductor arrangement Vertical Horizontal Horizontal
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV 3 No. Of phases 3 3 3 4 System frequency (Hz) 50 50 50 5 No. of wires 5 3 3 6 Fault level (MVA) 25 350 1500 7 Fault Current / Duration * * 25 kA / 3s 8 Earth Fault Current / Duration * 3 kA / 3s 3 kA / 3s 9 Neutral point Earthing Solid Resistance Resistance 10 Conductor arrangement Vertical Horizontal Horizontal All low voltage equipment must be capable of operating within range of +10% to –15% of the rated voltage, tripping devices shall be capable of operating within the range +10% to –25% of the rated voltage.
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data: 1 Normal Voltage 415V 11KV 33KV 2 Maximum Voltage 500V 12KV 36KV 3 No. Of phases 3 3 3 4 System frequency (Hz) 50 50 50 5 No. of wires 5 3 3 6 Fault level (MVA) 25 350 1500 7 Fault Current / Duration 120KA/3S * 25 kA / 3s 8 Earth Fault Current / Duration * 3 kA / 3s 3 kA / 3s 9 Neutral point Earthing Solid Resistance Resistance 10 Conductor arrangement Vertical Horizontal Horizontal ⮚ Technical Specifications for Item no.1: Rated 36 KV, Single Core Cable, Aluminum Conductor of 400 mm2, XLPE Insulated, Copper Wire Screened, Aluminum Wire Armored, And PVC Sheath. ◼ As per the details
Power System Particulars;. The plant and materials supplied shall be suitable in all respect for continuous operation in the existing system having the following data:

Related to Power System Particulars;

Time is Money Join Law Insider Premium to draft better contracts faster.