We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Common use of Prepaid Start-up Charge Clause in Contracts

Prepaid Start-up Charge. Prepaid Start-up Charge for each Unit operating under Condition 1 for each Contract Year will be calculated as the Prepaid Start-up Cost times the number of Prepaid Start- ups. The number of Prepaid Start-up equals the Maximum Annual Start-ups per Unit. The Prepaid Start-up Cost will be calculated in accordance with Equation D-1 for Start-up Cost with the following assumptions: a. Hourly Fuel Price: For the initial Contract Year the Hourly Fuel Price shall be the simple average of the applicable index prices from Table C1-8 of Schedule C for the period beginning on the later of the initial publication date of such indices or January 1, 1998 and ending December 31, 1998, plus the applicable Transportation Rate under Equation C1-8 as in effect on April 1, 1999. For each subsequent Contract Year, the Hourly Fuel Price shall be agreed upon by CAISO and Owner; if there is no agreement, the Hourly Fuel Price shall be the simple average of the Hourly Fuel Prices for the twelve months ending the prior June 30 as calculated in accordance with Equation C1-8 of Schedule C; b. Energy Price shall be based on the [insert Applicable UDC Tariff rate], including applicable demand charges, provided that the Applicable UDC Tariff rate shall only be the energy charge rate at those Facilities where Units have the capability to use Energy from other units at the same Facility to effect Start-ups or where generation from other units is otherwise permitted under the CAISO Tariff to be netted against auxiliary power needed to effect Start-up of the Unit. For the initial Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-use Energy for the six-month period ending December 31, 1998 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same time period. For Facilities that have not been charged for auxiliary power for the six-month period ending December 31, 1998, the Energy Price for the Initial Contract Year shall be the simple average of the prices for Energy for varying times of day shown in the Applicable UDC Tariff. For each subsequent Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-use Energy for the twelve months ending the prior June 30 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same twelve-month period;

Appears in 19 contracts

Samples: Reliability Must Run Contract, Reliability Must Run Contract, Reliability Must Run Contract

Prepaid Start-up Charge. Prepaid Start-up Charge for each Unit operating under Condition 1 for each Contract Year will be calculated as the Prepaid Start-up Cost times the number of Prepaid Start- Start-ups. The number of Prepaid Start-up equals the Maximum Annual Start-ups per Unit. The Prepaid Start-up Cost will be calculated in accordance with Equation D-1 for Start-up Cost with the following assumptions: a. Hourly Fuel Price: For the initial Contract Year the Hourly Fuel Price shall be the simple average of the applicable index prices from Table C1-8 of Schedule C for the period beginning on the later of the initial publication date of such indices or January 1, 1998 and ending December 31, 1998, plus the applicable Transportation Rate under Equation C1-8 as in effect on April 1, 1999. For each subsequent Contract Year, the Hourly Fuel Price shall be agreed upon by CAISO and Owner; if there is no agreement, the Hourly Fuel Price shall be the simple average of the Hourly Fuel Prices for the twelve months ending the prior June 30 as calculated in accordance with Equation C1-8 of Schedule C; b. Energy Price shall be based on the [insert Applicable UDC Tariff rate], including applicable demand charges, provided that the Applicable UDC Tariff rate shall only be the energy charge rate at those Facilities where Units have the capability to use Energy from other units at the same Facility to effect Start-ups or where generation from other units is otherwise permitted under the CAISO Tariff to be netted against auxiliary power needed to effect Start-up of the Unit. For the initial Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-use Energy for the six-month period ending December 31, 1998 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same time period. For Facilities that have not been charged for auxiliary power for the six-month period ending December 31, 1998, the Energy Price for the Initial Contract Year shall be the simple average of the prices for Energy for varying times of day shown in the Applicable UDC Tariff. For each subsequent Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-end- use Energy for the twelve months ending the prior June 30 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same twelve-month period;

Appears in 14 contracts

Samples: Must Run Service Agreement, Must Run Service Agreement, Must Run Service Agreement

Prepaid Start-up Charge. Prepaid Start-up Charge for each Unit operating under Condition 1 for each Contract Year will be calculated as the Prepaid Start-up Cost times the number of Prepaid Start- Start-ups. The number of Prepaid Start-up equals the Maximum Annual Start-ups per Unit. The Prepaid Start-up Cost will be calculated in accordance with Equation D-1 for Start-up Cost with the following assumptions: a. Hourly Fuel Price: For the initial Contract Year the Hourly Fuel Price shall be the simple average of the applicable index prices from Table C1-8 of Schedule C for the period beginning on the later of the initial publication date of such indices or January 1, 1998 and ending December 31, 1998, plus the applicable Transportation Rate under Equation C1-8 as in effect on April 1, 1999. For each subsequent Contract Year, the Hourly Fuel Price shall be agreed upon by CAISO and Owner; if there is no agreement, the Hourly Fuel Price shall be the simple average of the Hourly Fuel Prices for the twelve months ending the prior June 30 as calculated in accordance with Equation C1-8 of Schedule C; b. Energy Price shall be based on the [insert Applicable UDC Tariff rate], including applicable demand charges, provided that the Applicable UDC Tariff rate shall only be the energy charge rate at those Facilities where Units have the capability to use Energy from other units at the same Facility to effect Start-ups or where generation from other units is otherwise permitted under the CAISO Tariff to be netted against auxiliary power needed to effect Start-up of the Unit. For the initial Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-use Energy for the six-month period ending December 31, 1998 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same time period. For Facilities that have not been charged for auxiliary power for the six-month period ending December 31, 1998, the Energy Price for the Initial Contract Year shall be the simple average of the prices for Energy for varying times of day shown in the Applicable UDC Tariff. For each subsequent Contract Year, the Energy Price shall be calculated as the total auxiliary power (including Energy for Start-ups) costs charged to the Facility by its supplier of end-use Energy for the twelve months ending the prior June 30 divided by the auxiliary power (including Energy for Start-ups) consumed at the Facility for that same twelve-month period;

Appears in 6 contracts

Samples: Must Run Service Agreement, Must Run Service Agreement, Must Run Service Agreement