Quality Control A. Controlled Affiliate agrees to use the Licensed Marks and Name only in connection with the licensed services and further agrees to be bound by the conditions regarding quality control shown in attached Exhibit A as they may be amended by BCBSA from time-to-time.
Project Reporting During the course of Implementation Services, the NAVITAIRE Hosted Revenue Accounting Services Project Manager will coordinate status reporting with the NAVITAIRE Hosted Reservation Services Project Manager. Following completion of installation of the Hosted Reservation Services, the NAVITAIRE Hosted Revenue Accounting Services Project Manager will provide Customer with status on the remaining Implementation Services for Hosted Revenue Accounting Services as follows; (a) Weekly Project Plan Update and Status Report; (b) Weekly Updated Issues/Resolution List; and (c) Executive Summary.
Quality control system (i) The Contractor shall establish a quality control mechanism to ensure compliance with the provisions of this Agreement (the “Quality Assurance Plan” or “QAP”).
Quality control records and Documents The Contractor shall hand over a copy of all its quality control records and documents to the Authority’s Engineer before the Completion Certificate is issued pursuant to Clause 12.2. The Contractor shall submit Road Signage Plans to the Authority Engineer for approval at least 6 (six) months prior to expected completion of Project Highway.
Quality Control Program The Contractor shall describe the Quality Control Program in a written document which shall be reviewed by the Engineer prior to the start of any production, construction, or off-site fabrication. The written Quality Control Program shall be submitted to the Engineer for review at least ten (10) calendar days before the start of construction. The Quality Control Program shall be organized to address, as a minimum, the following items:
Pollution Control Requirements If this Contract is for $100,000 or more, the CONSULTANT:
Quality Control Plan Within forty five (45) days after the design development documents are approved, the Design-Builder shall develop a quality control plan for the Project (the “Quality Control Plan”). A draft of the Quality Control Plan shall be submitted to the Department and shall be subject to the Department’s review and approval. The Quality Control Plan shall be tailored to the specific products/type of construction activities contemplated by the GMP Basis Documents, and in general, shall include a table of contents, quality control team organization, duties/responsibilities of quality control personnel, submittal procedures, inspection procedures, deficiency correction procedures, documentation process, and a list of any other specific actions or procedures that will be required for key elements of the Work.
Commodity Compliance and Compatibility It is the Contractor’s responsibility to ensure that the Commodities supplied are compliant with the Contract requirements, specifications, terms, and conditions. Additionally, the Contractor shall ensure that all Commodities ordered by the Customer are fully compatible with each other and with any associated pre-existing Commodity possessed by the Customer and disclosed to the Contractor by the Customer. The Contractor’s acceptance of the Customer’s order shall indicate that the Contractor agrees to deliver a Commodity that is fully compliant and compatible with the Customer’s order requirements, specifications, terms, and conditions. In the event any ordered Base Equipment, OEM and Non-OEM Option(s), Part(s), Accessory(ies), and Implement(s); and their respective features, equipment, and components are found by the Customer to be missing, incorrect, defective, damaged, non- compatible, or non-compliant, the Contractor shall, at the Customer’s discretion, be required to complete one of the following: • Install or repair the Base Equipment, OEM and Non-OEM Option(s), Part(s), Accessory(ies), and Implement(s), and their respective features, equipment, and components; • Replace the Base Equipment, OEM and Non-OEM Option(s), Part(s), Accessory(ies), and Implement(s); and their respective features, equipment, and components; • Refund the purchase price of the Base Equipment, OEM and Non-OEM Option(s), Part(s), Accessory(ies), and Implement(s); and their respective features, equipment, and components to the Customer. Any changes necessary after the delivery of the Customer’s order that are required to bring a Commodity into compliance or compatibility due to an incorrect order fulfillment by the Contractor shall be accomplished at the Contractor’s expense.
Monthly Reporting Within twenty (20) calendar days following the end of each calendar month, Registry Operator shall deliver to ICANN reports in the format set forth in Specification 3 attached hereto (“Specification 3”).
Supervisory Control and Data Acquisition (SCADA) Capability The wind plant shall provide SCADA capability to transmit data and receive instructions from the ISO and/or the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, as applicable, to protect system reliability. The Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected and the wind plant Developer shall determine what SCADA information is essential for the proposed wind plant, taking into account the size of the plant and its characteristics, location, and importance in maintaining generation resource adequacy and transmission system reliability in its area.