Reducing fittings Clause Samples

The 'Reducing fittings' clause defines the requirements and standards for the use of pipe fittings that connect pipes of different diameters within a system. It typically specifies the types of reducing fittings permitted, such as concentric or eccentric reducers, and may outline acceptable materials, installation methods, and pressure ratings. By establishing clear guidelines for these components, the clause ensures compatibility and safety in piping systems, preventing leaks or failures that could arise from improper connections.
Reducing fittings. Where fittings have reducing ends or branches they are described as 'reducing'. In the case of pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should the Contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will be entertained.
Reducing fittings. Where fittings have reducing ends or branches they are described as 'reducing'. In the case of pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should the Contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will be entertained. 22 15mm Pipe chased into brick walls. A1 : 2 A2 : 3 A3 : 2 A4 : 4 23 22mm Ditto. A1 : 2 A2 : 7 A3 : 2 A4 : 4 m 11 m 15 Section 2 Bill No. 10 Plumbing and Drainage (Provisional) 24 15mm Fittings. No 11 A1 : 2 A2 : 3 A3 : 2 A4 : 4 25 22mm Fittings. A1 : 2 A2 : 3 A3 : 2 A4 : 4 No 11 Carried to Collection Section 2 Bill No. 10 Plumbing and Drainage (Provisional) Section 2 Bill No. 10 Plumbing and Drainage (Provisional) Total Brought Forward from Page No. Section 2 Bill No. 10 Plumbing and Drainage (Provisional) 66 67 68 R Amount SECTION 2 BILL No. 11 PAINTWORK Note that the total quantity per each item is split into the various buildings and appears below each description as follows: A1 - DWG 04 - Staff Ablutions (2M2F1D) A2 - DWG 06 - Grade R Ablution (3R1T) A3 - DWG 14 - Male Ablutions (6B) A4 - DWG 35 - Female Ablutions (6G)
Reducing fittings. Where fittings have reducing ends or branches they are described as "reducing" and only the largest end or branch size is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained Fixing of pipes. Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing to walls, etc, casting in, building in or suspending not exceeding 1m below suspension level. Pipes chased into brickwork must be wrapped with two layers of ▇▇▇▇▇ brown paper tied with wire. Rates are to include for wrapping around joints and fittings. Section No. 2 Bill No. 11 Plumbing & Drainage (Measured Provisionally) Water pipework is to be disinfected at completion. Pipes to be taped shall be coated with the appropriate primer and the tape shall be applied in the appropriate widths and with overlaps. Couplings and fittings to pipes shall be taped in strict accordance with the manufacturer's instructions. Prices for wrapping of pipes shall include for all work as described to couplings in the length. Laying, backfilling, bedding, etc of pipes: Pipes shall be laid and bedded in accordance with manufacturers' instructions and trenches shall be carefully backfilled. Where no manufacturers' instructions exist, pipes shall be laid in accordance with the relevant section of SANS 2001. Section No. 2 Bill No. 11 Plumbing & Drainage (Measured Provisionally) Descriptions of cast iron roof outlets shall be deemed to include joints to pipes and casting into concrete (adaptors for joints to PVC pipes, etc are given separately). Descriptions of overflow pipes where measured in number, shall be deemed to include joints to cisterns and splay cut ends. Descriptions of pipes laid in and including trenches and of inspection ▇▇▇▇▇▇▇▇, catchpits, etc shall be deemed to include excavation, bedding, backfilling, compaction to a minimum of 95% Mod AASHTO density and disposal of surplus material on site. Descriptions of service pipes and flexible connecting pipes shall be deemed to include connections to taps, cisterns, etc and to steel pipes (adaptors for connections to copper pipes, etc are given separately). Descriptions of WC pans, slop hoppers, etc shall be deemed to include for joints to soil pipes (pan connectors are separately measured). Ogee profile seamless aluminium guttering fixed to fascia boards (fascias esewhere measured). 1 125 x 85mm OGEE ▇▇▇▇▇ gutter m 155 2 75 x 50mm fl...
Reducing fittings. Where fittings have reducing ends or branches they are described as "reducing". In the case of pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will be entertained Exposed surfaces of concrete stormwater channels, cover slabs, inspection eye marker slabs, ▇▇▇▇▇▇ tops, cleaning eye tops, catchpits, inspection ▇▇▇▇▇▇▇▇, etc shall be finished smooth with plaster No claim for rock excavation will be entertained unless the contractor has timeously notified the quantity surveyor thereof prior to backfilling Pipes shall be laid and bedded and trenches shall be carefully backfilled in accordance with manufacturers' instructions Where no manufacturers' instructions exist, pipes shall be laid in accordance with clauses 5.1 and 5.2 of each of the following: SABS 1200 L : Medium-pressure pipelines LD : Sewers LE : Stormwater drainage Pipe trenches etc shall be backfilled in accordance with clauses 3, 5.5, 5.6, 5.7 and 7 of SABS 1200 DB : Earthworks (Pipe trenches) Pipes shall be bedded in accordance with clauses 3.1 to 3.4.1, 5.1 to 5.3 and 7 of SABS 1200 LB : Bedding (Pipes). Unless otherwise described bedding of rigid pipes shall be class B bedding Section No. 5 Bill No. 3 STORMWATER (PROVISIONA) 1 110mm Slotted uPVC pipes laid in and including trenches not exceeding 1m deep, including 19mm crushed stone encasing size 300 x 300mm and Bidum Type U24 filter fabric blanket wrapped around encasing with 150mm side and 300mm end laps including stitching, complete with excavations and carting away of excavated material and backfilling of trenches with clean river sand m 200 25MPa/19mm unreinforced concrete with rounded salient edges and finished on exposed surfaces with 2:1 cement mortar, laid to falls in panels not exceeding 2m long with 12mm bitumen impregnated softboard movement joints with exposed edges raked out for a depth of 10mm and sealing with "Sikaflex-1a" joint sealant including all necessary formwork, excavations, compaction, etc 3 Surface channel size 1500mm wide x average 120mm thick with 50mm deep V-shaped waterway (concrete = 0,18 m3/m) m 240 4 Extra over 1200mm wide channel for closed ends, angle intersection, tee intersections, etc No 2