Sampling and Testing Sample Clauses

Sampling and Testing. A qualified independent laboratory, reasonably acceptable to both Parties, shall perform sampling, proximate analysis (including moisture analysis), total sulfur analysis, oxidation analysis, plastic behavior analysis, and petrography of each Coal shipment. Such sampling, analysis and petrography shall be performed in accordance with ASTM Standards. The results of such analysis and petrography shall be promptly provided to each member of the Coal Committee in Writing, and shall be used for determining compliance with the Coal Blend Standards in respect of each Coal Blend.
AutoNDA by SimpleDocs
Sampling and Testing. Prior to purchasing any of the Coals comprising any Coal Blend selected by the Coal Committee (except for the sampling and testing thereof for the purpose of determining whether such coals should be incorporated into a Coal Blend), sampling and testing of all such Coals shall be performed in a manner reasonably acceptable to Off-Taker and Provider, and they shall be provided with a reasonable opportunity to review and, if appropriate, object to such test results. In addition, Provider or its designee shall also maintain a quality control program in respect of Coal blending in accordance with generally accepted industry practice, which shall be reasonably satisfactory to Off-Taker. Such quality control program is to include, without limitation, procedures for sampling, testing and reporting Coal Blend quality charged into the coke ovens at the Plant.
Sampling and Testing. Prior to purchasing any of the Coals comprising any Coal Blend selected by the Coal Committee (except for purchases made for the purpose of sampling and testing thereof), sampling and testing of all such Coals shall be performed in a manner reasonably acceptable to the Parties, and each Party shall be provided with a reasonable opportunity to review and, if appropriate, object to such test results. Such sampling and testing shall include the collection of representative samples of meaningful quantities of each potential Coal to be prepared and tested in a laboratory approved by the Coal Committee for moisture, ash, sulfur, volatile matter, PSI (free swelling index), oxidation (via petrographic techniques and US Steel method), ash mineral analysis (including P205, Na20, K20 and chlorine) and other parameters as agreed to from time to time. The Seller and Purchasers will use their best commercial efforts to have the cost of such analysis be to the account of the potential Coal supplier(s). Seller shall arrange for similar sampling and testing to be carried out with respect to Coals actually purchased by Seller for the production of coke and each Party shall be provided a reasonable opportunity to review and, if appropriate, object to such test results. Upon the reasonable request of Purchasers, Seller shall process blends of Coals for trial purposes at the Plant.
Sampling and Testing. (i) The District agrees that the City may, at its option and expense, sample wastewater discharges within the District System at:
Sampling and Testing. THE FOLLOWING IS ADDED TO THE FIRST PARAGRAPH: Ensure that the mix meets the requirements as specified in 902.02.04.A, otherwise the RE or ME will reject the material. THE SECOND PARAGRAPH IS CHANGED TO: During production, the ME will take one random acceptance sample from each 700 tons of production to verify composition. Conduct air voids and draindown tests as directed by the ME. THE FOURTH PARAGRAPH IS CHANGED TO: The ME will perform sampling according to NJDOT B-2 or ASTM D 3665, and will perform testing for composition according to AASHTO T 308 or NJDOT B-5. Perform testing for air voids according to AASHTO T 209 and either NJDOT B-6 or AASHTO T 331. Perform testing for draindown according to NJDOT B-7 or NJDOT B-8.
Sampling and Testing. X. Xxxxxxx of the aggregates for mix design and determination of suitability shall be taken under the supervision of Engineer and delivered to the laboratory, well in advance of the scheduled placing of concrete. Records of tests which have been made on proposed aggregates and on concrete made from this source of aggregates shall be furnished to Engineer in advance or the work for use in determining aggregate suitability. The costs of all such tests, sampling, etc., shall be borne by Contractor.
Sampling and Testing. 4.16.7.6.1. The Contractor shall notify NYCDOT of the intended source of the material a minimum of 21 calendar days in advance of the scheduled use of the material to allow time for sampling, sample shipment and testing.
AutoNDA by SimpleDocs
Sampling and Testing. THE ENTIRE TEXT IS CHANGED TO:
Sampling and Testing. On a confidential basis, Terminal Company will perform the following on-site testing, and associated sampling, at the Terminal, at no additional charge, in order to determine whether Customer’s blended Product meets the Delivery Pipeline’s minimum specification: sulfur; API gravity; RVP; and BS&W. At Customer’s request and expense, Terminal Company will arrange for an independent inspector, selected by Customer, to perform any off-site testing on Customer’s Product. Any testing performed by Terminal Company or by any independent inspector arranged by Terminal Company, at Customer’s request, will be performed in accordance with the then-current ASTM procedures. Terminal Company will promptly provide Customer with a complete and unaltered copy of any testing reports produced or obtained by or at the request of Terminal Company regarding Customer’s Product. All such testing reports that are generated under this Agreement shall be deemed Customer’s proprietary and confidential business information and shall not be disclosed, in any form or format, by Terminal Company or any of its Representatives to any third party without Customer’s prior written consent except as necessary to: enforce Terminal Company’s rights under this Agreement; to respond in any legal proceeding (including, without limitation, any deposition, interrogatory, subpoena, or civil investigative demand); and to defend against any allegation by a Delivery Pipeline that Terminal Company has failed to meet the Delivery Pipeline’s applicable, minimum Product specifications.
Sampling and Testing. (a) Aradigm will be responsible for sampling of Other Excipients, API and non-iDMS identical components. Novo Nordisk Delivery Technologies, Inc. will be responsible for all other sampling of all iDMS identical materials and the Packaged Dosage Forms.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!