Setting conditions Clause Samples
Setting conditions. The setting conditions for the test to determine the net power are indicated in Table 2. Table 2
1. Setting of carburettor(s), evaporator/pressure regulator In accordance with the manufacturer's production specifications, and used without further alteration for the particular application.
2. Setting of injection pump delivery system
3. Ignition or injection timing (timing curve)
4. Governor setting 5. Emission control devices
Setting conditions. The setting conditions shall conform to the manufacturer's specifications for the production motor and be used without further alteration for the particular application.
2.5. Data to be recorded
2.5.1. The test for determining the net power shall be carried out with the accelerator control set at the maximum position.
2.5.2. The motor must have been run-in in accordance with the recommendations of the applicant for the approval.
2.5.3. Torque and speed data shall be recorded simultaneously.
2.5.4. If needed, the cooling liquid temperature recorded at the motor outlet must be maintained at ±5 K of the thermostat temperature setting specified by the manufacturer. For air cooling drive trains, the temperature at a point indicated by the manufacturer shall be kept within +0/-20 K of the maximum value specified by the manufacturer.
2.5.5. The temperature of the lubricating oil measured in the oil sump or at the outlet from the oil temperature exchanger (if any) shall be maintained within the limits prescribed by the manufacturer.
2.5.6. An auxiliary regulating system may be used, if necessary, to maintain the temperature within the limits specified in paragraphs 2.5.4. and 2.5.5. above.
Setting conditions. The setting conditions for the test to determine the net power are indicated in table 2. TABLE 2 - Setting conditions 1 Setting of carburettor(s) In accordance with the manufacturer's production specifications and used without further alteration for the particular application 2 Setting of injection pump delivery system 3 Ignition or injection timing (timing curve) 4 Governor setting 5 Anti-pollution devices */ Exhaust gas recirculation. UN ECE Regulation 24/03 52 5.3 Test conditions
5.3.1 The net power test shall consist of a run at full throttle for positive-ignition engines and at fixed full-load fuel injection pump setting for diesel engines, the engine being equipped as specified in table 1.
5.3.2 Performance data shall be obtained under stabilizing operating conditions with an adequate fresh air supply to the engine. The engines must have been run-in in accordance with the manufacturer's recommendations. Combustion ▇▇▇▇▇▇▇▇ may contain deposits, but in limited quantity. Test conditions, such as inlet air temperature, shall be selected as near to reference conditions (see 6.2) as possible in order to minimize the magnitude of the correction factor.
5.3.3 The temperature of the inlet air to the engine (ambient air) shall be measured within 0.15 m upstream of the point of entry to the air cleaner, or, if no air cleaner is used, within
Setting conditions. The setting conditions shall conform to the manufacturer’s specifications for the production motor and be used without further alteration for the particular application.
Setting conditions. The setting conditions for the test to determine the net power are indicated in table 2. TABLE 2 - Setting conditions 1 Setting of carburettor(s) In accordance with the manufacturer's production specifications and used without further alteration for the particular application 2 Setting of injection pump delivery system 3 Ignition or injection timing (timing curve) 4 Governor setting 5 Anti-pollution devices