We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Common use of Specific tests Clause in Contracts

Specific tests. Filament lamps approved according to UN Regulation No. 37, gas-discharge light sources approved according to UN Regulation No. 99 and LED modules are exempted from the tests indicated in paragraphs 4.3.1. and 4.3.2. below. 4.1. [Reserved] 4.2. Gas discharge light sources The starting test shall be applied to light sources which have not been aged and have not been used for a period of at least 24 hours prior to the test. The light source shall start directly and remain alight. 4.3. Run-up 4.3.1. Filament lamps are exempted from this test. 4.3.2. Gas discharge light sources The run-up test shall be applied to light sources which have not been used for a period of at least 1 hour prior to the test. The front fog lamp shall reach at least in the point 0°, 2.5°D on the line 6 a luminous intensity: After 1 second: 25 per cent of its objective luminous flux; After 4 seconds: 80 per cent of its objective luminous flux. The objective luminous flux is indicated on the submitted data sheet. 4.4. Hot re-strike 4.4.1. Filament lamps are exempted from this test. 4.4.2. Gas discharge light sources The light source shall be started and be operated with the electronic light source control-gear at test voltage for a period of 15 minutes. The supply voltage to the electronic light source control-gear shall then be switched off for a period of 10 seconds, and be switched on again. The light source shall restart directly after being switched-off for a period of 10 seconds. After one second the light source shall emit at least 80 per cent of its objective luminous flux. 4.5. Colour rendering 4.5.1. Red content In addition to measurements as described in paragraph 7. of this Regulation, the minimum red content of the light of a LED module shall be such that: Where: Ee () (unit: W) is the spectral distribution of the irradiance;

Appears in 2 contracts

Samples: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles

Specific tests. Filament lamps approved according to UN Regulation No. 37, gas-discharge light sources approved according to UN Regulation No. 99 and LED modules are exempted from the tests indicated in paragraphs 4.3.1. and 4.3.2. below. 4.1. [Reserved] 4.2. Gas discharge light sources The starting test shall be applied to light sources which have not been aged and have not been used for a period of at least 24 hours prior to the test. The light source shall start directly and remain alight. 4.3. Run-up 4.3.1. Filament lamps are exempted from this test. 4.3.2. Gas discharge light sources The run-up test shall be applied to light sources which have not been used for a period of at least 1 hour prior to the test. The front fog lamp shall reach at least in the point 0°, 2.5°D on the line 6 a luminous intensity: After 1 second: 25 per cent of its objective luminous flux; After 4 seconds: 80 per cent of its objective luminous flux. The objective luminous flux is indicated on the submitted data sheet. 4.4. Hot re-strike 4.4.1. Filament lamps are exempted from this test. 4.4.2. Gas discharge light sources The light source shall be started and be operated with the electronic light source control-gear at test voltage for a period of 15 minutes. The supply voltage to the electronic light source control-gear shall then be switched off for a period of 10 seconds, and be switched on again. The light source shall restart directly after being switched-off for a period of 10 seconds. After one second the light source shall emit at least 80 per cent of its objective luminous flux. 4.5. Colour rendering 4.5.1. Red content In addition to measurements as described in paragraph 7. of this Regulation, the minimum red content of the light of a LED module shall be such that: Where: kred = 780 nm  Ee () V() d =610 nm 780 nm  Ee (unit: W) is the spectral distribution of the irradiance;V() d =380 nm  0.05

Appears in 2 contracts

Samples: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles

Specific tests. Filament lamps approved according to UN Regulation No. 37, gas-discharge light sources approved according to UN Regulation No. 99 and LED modules are exempted from the tests indicated in paragraphs 4.3.1. and 4.3.2. below. 4.1. [Reserved] 4.2. Gas discharge light sources The starting test shall be applied to light sources which have not been aged and have not been used for a period of at least 24 hours prior to the test. The light source shall start directly and remain alight. 4.3. Run-up 4.3.1. Filament lamps are exempted from this test. 4.3.2. Gas discharge light sources The run-up test shall be applied to light sources which have not been used for a period of at least 1 hour prior to the test. The front fog lamp shall reach at least in the point 0°, 2.5°D on the line 6 a luminous intensity: After 1 second: 25 per cent of its objective luminous flux; After 4 seconds: 80 per cent of its objective luminous flux. The objective luminous flux is indicated on the submitted data sheet. 4.4. Hot re-strike 4.4.1. Filament lamps are exempted from this test. 4.4.2. Gas discharge light sources The light source shall be started and be operated with the electronic light source control-gear at test voltage for a period of 15 minutes. The supply voltage to the electronic light source control-gear shall then be switched off for a period of 10 seconds, and be switched on again. The light source shall restart directly after being switched-off for a period of 10 seconds. After one second the light source shall emit at least 80 per cent of its objective luminous flux. 4.5. Colour rendering 4.5.1. Red content In addition to measurements as described in paragraph 7. of this Regulation, the minimum red content of the light of a LED module or light-generator shall be such that: Where: kred = 780 nm ∫ Ee (λ) V(λ) dλ λ=610 nm 780 nm ∫ Ee (unit: Wλ) is the spectral distribution of the irradiance;V(λ) dλ λ=380 nm ≥ 0.05

Appears in 1 contract

Samples: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles