Steam Condenser Sample Clauses
Steam Condenser. A water cooled steam condenser shall be provided for each STG. The condenser shall be a shell-and-tube type with cooling water flowing inside and steam condensing outside the tubes, which shall be arranged in a dual or single pass configuration. The condenser shall be capable of operating with full STG steam by-pass receiving up to 100% of the HRSG(s) rated thermal capacity with the duct burners off. The condenser shall comply with recommended design methods of the Heat Exchange Institute. Each condenser shall be provided with two 50% capacity condensate pumps with one uninstalled equal size pump assembly, without can as a spare for the project. Redundant steam ejection system is required. An option will be provided for each pump to be sized to provide 100% of the condensate for one HRSG full load without duct firing or power augmentation on a 95(degree)F ambient day.