STRUCTURES AND RELATED WORK Clause Samples

STRUCTURES AND RELATED WORK. ▇▇▇▇▇▇ Mechanical will provide access to equipment within its scope in accordance with sound engineering and safety practices, including catwalks, platforms and stairs in the Main Process Building for access to the major tanks and equipment. Unit heaters are provided for the DD&E, Main Process, Utility and Maintenance buildings. Unit heaters in the process areas are designed to maintain temperatures above 40°F in the event of a winter shutdown. ▇▇▇▇▇▇ Mechanical will provide the initial stocking of permanent safety equipment for the plant including fire extinguisher stations, safety showers, and eyewash stations so the plant is in compliance with the Uniform Fire Code and governing building codes. ▇▇▇▇▇▇ Mechanical will install Owner furnished Delta T standard lab equipment package to provide the Owner with the proper tools to continually monitor process performance and help diagnose any process problems that occur. This lab package provided by Owner will contain, as a minimum, one each of the following items: · High Performance Liquid Chromatograph (HPLC) · ▇▇▇▇ ▇▇▇▇▇▇ product moisture analyzer · Centrifuge - lab size · Microscope · pH meter · Dissolved oxygen meter · Analytical balance · Moisture meter · Hotplate · Sieves and shaker · Incubator · Provision of lab supplies, furniture, storage and glassware ▇▇▇▇▇▇ Mechanical will provide all equipment, components and piping as required for the Work for the Plant to meet the Contract specifications excluding any items specifically defined herein or the attached DOR as being the Owner’s responsibility. ▇▇▇▇▇▇ Mechanical’s responsibilities include, but are not limited to, the following: · Installation of all equipment in final position, complete, anchored, connected and in operable condition, except items specifically defined herein as the Owner’s responsibility. · Erect large field-fabricated tanks on-site. · Provide all piping systems in accordance with the final design and Contract specifications. · Provide piping system identification in accordance with Contract specifications. · Prime and paint or insulate all carbon steel materials. · Provide supplementary steel supports and brackets for equipment. · Commission and test all tanks and mechanical systems and connections in accordance with the Contract specifications. · Provide all manual and automated valves. · Provide all pipe racks, pipe supports, hangers, anchors, and fasteners. · Provide all Plant process piping including buried piping. · Provide requ...
STRUCTURES AND RELATED WORK. Delta-T will provide the buildings listed below for the Plant. They will be conventional, pre-engineered metal buildings and will comply with the Contract specifications and governing building code requirements. Exact configurations will depend upon final engineering and plant layout. Main Process Building - A metal building to house process equipment with a general purpose electrical classification, sized to adequately accommodate the final layout design for the equipment. It will come complete with all partitions, walls, MCC room, control room, lab, restrooms, employee breakroom, and other interior buildout items and features required to implement the final design. Insulation will be provided in the roof and walls. Building services to include: o Male and female employee bathroom fixtures and plumbing including showers o Fixtures and plumbing for laboratory o HVAC in offices, control room, lab, bathrooms, and break room areas o Ventilation in accordance with design codes for process areas o Climate controlled MCC room -------------------------------------------------------------------------------- Page 42 o Electrical receptacles per NEC requirements DD&E Equipment Enclosure - A metal building sized to adequately accommodate the final layout design for selected DD&2E process equipment. Insulation will be provided in the roof and walls. Building services to include: * Ventilation in accordance with design codes for process area * Electrical receptacles per NEC requirements DDGS Storage & Loadout Building - A metal building to house the DDGS storage and handling system, sized to adequately accommodate the final layout design for this equipment. This building will provide flat storage of DDGS, complete with all handling pits, conveyors, load out hoppers, and other structures and components required to implement the final design. Insulation will be provided in the roof and walls. Utility Building - A metal building to house the boiler, chiller, air compressor and support equipment, sized to adequately accommodate the final layout design for this equipment. Insulation will be provided in the roof only. Building services to include: o Building ventilation only (no heating or air conditioning) o Adequate convenience receptacles General - Delta-T will provide all building related concrete including footings, foundations, walls, and floor slabs as required to complete the Work. Delta-T will also provide all interior and exterior equipment foundations, pads and su...