Test arrangements Sample Clauses

Test arrangements. The observation time to be used for the measurements shall be as for quasi-stationary equipment as defined in IEC 00000-0-0, Table 4.
AutoNDA by SimpleDocs
Test arrangements. The test set-up shall be performed according to paragraph 5. of CISPR 22 for conducted emissions.
Test arrangements. 3.1. The test shall be performed according to ALSE method described in paragraph 6.4. of CISPR 25. 3.2. Alternative measuring location As an alternative to an absorber lined shielded enclosure (ALSE) an open area test site (OATS) which complies with the requirements of CISPR 16-1-4 may be used (see Figure 1 of the appendix to Annex 7).
Test arrangements. The tests for vehicle in configuration "REESS charging mode coupled to the power grid" with rated current ≤ 16 A per phase and not subjected to conditional connection shall be performed according to paragraph 6. of IEC 00000-0-0.
Test arrangements. The test shall be performed according to paragraph 7.4.1. of CISPR 16-2-1 as floor-standing equipment.
Test arrangements. The artificial network(s) to be used for the measurement on vehicle are
Test arrangements. 3.1. For ESA other than involved in "REESS charging mode coupled to the power grid" the test shall be performed according to the ALSE method described in paragraph 6.4. of CISPR 25. 3.2. For ESAs in configuration "REESS charging mode coupled to the power grid" the test arrangement shall be according to Figure 2 of the appendix to this annex. 3.2.1. The shielding configuration shall be according to the vehicle series configuration. Generally all shielded High Voltage (HV) parts shall be properly connected with low impedance to ground (e.g. AN, cables, connectors etc.). ESAs and loads shall be connected to ground. The external HV power supply shall be connected via feed-through-filtering. 3.2.2. The ESA power supply lead shall be connected to the power supply through an HV-AN (for ESA with DC HV supply) and/or AMN (for ESA with AC supply). DC HV supply shall be applied to the ESA via a 5 μH/50 Ω HV-AN (see Appendix 8 clause 2). AC supply shall be applied to the ESA via a 50 μH/50 Ω AMN (see Appendix 8 clause 4). 3.2.3. Unless otherwise specified the length of the Low Voltage (LV) harness and the XX xxxxxxx parallel to the front edge of the ground plane shall be 1,500 mm (±75 mm). The total length of the test harness including the connector shall be 1,700 mm (+300/-0 mm). The distance between the LV harness and the XX xxxxxxx shall be 100 mm (+100/-0 mm). 3.2.4. All of the harnesses shall be placed on a non-conductive, low relative permittivity material (εr ≤ 1.4), at 50 mm (±5 mm) above the ground plane. 3.2.5. Shielded supply lines for HV+ and HV- line and three phase lines may be coaxial cables or in a common shield depending on the used plug system. The original HV-harness from the vehicle may be used optionally. 3.2.6. Unless otherwise specified, the ESA case shall be connected to the ground plane either directly or via defined impedance. 3.2.7. For onboard chargers, the AC/DC power lines shall be placed the furthest from the antenna (behind LV and XX xxxxxxx). The distance between the AC/DC power lines and the closest harness (LV or HV) shall be 100 mm (+100/-0 mm). 3.3. Alternative measuring location As an alternative to an absorber lined shielded enclosure (ALSE) an open area test site (OATS), which complies with the requirements of CISPR 16-1-4 may be used (see Figure 1 of the appendix to this annex).
AutoNDA by SimpleDocs
Test arrangements. The tests for ESA in configuration "REESS charging mode coupled to the power grid" with rated current ≤ 16 A per phase and not subjected to conditional connection shall be performed according to paragraph 4. of IEC 00000-0-0.
Test arrangements. Local/private communication lines connected to signal/control ports and lines connected to wired network ports shall be applied to the vehicle through AAN(s). The various AAN(s) to be used are defined in Appendix 8, clause 5: - Clause 5.1. for signal/control port with symmetric lines; - Clause 5.2. for wired network port with PLC on power lines;
Test arrangements. For ESA other than involved in "REESS charging mode coupled to the power grid" the test shall be performed according to the ALSE method described in paragraph 6.4. of CISPR 25.