Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customer’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable)) 2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customer’s premises and may have load coils. 2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customer’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box. 2.8.2.3.1 If NewPhone requests a UCSL and it is not available, NewPhone may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL. 2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises. 2.8.2.4.1 Upon request for USLD-INC from NewPhone, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhone’s use on this cross-connect panel. NewPhone will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s). 2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician. 2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx. 2.8.2.7 The site set-up must be completed before NewPhone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhone’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs. 2.8.2.8 Once the site set-up is complete, NewPhone will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone for Subloop pairs, expedite charges will apply for intervals less than five (5) days. 2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 15 contracts
Samples: MFN Agreement, MFN Agreement, MFN Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone AFN requests a UCSL and it is not available, NewPhone AFN may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneAFN, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneAFN’s use on this cross-connect panel. NewPhone AFN will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone AFN shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneAFN’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone AFN is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneAFN’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone AFN can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneAFN’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone AFN will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone AFN requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone AFN for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 4 contracts
Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone <<customer_short_name>> requests a UCSL and it is not available, NewPhone <<customer_short_name>> may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhone<<customer_short_name>>, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhone<<customer_short_name>>’s use on this cross-connect panel. NewPhone <<customer_short_name>> will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone <<customer_short_name>> shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone<<customer_short_name>>’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone <<customer_short_name>> is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone<<customer_short_name>>’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone <<customer_short_name>> can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhone<<customer_short_name>>’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone <<customer_short_name>> will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone <<customer_short_name>> requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone <<customer_short_name>> for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 3 contracts
Samples: Telecommunications, Telecommunications, Telecommunications
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth AT&T provides from an a customer’s point of demarcation to a BellSouth AT&T cross-connect device. The BellSouth AT&T cross-connect device may be located within a remote terminal (RT) or a stand-stand- alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth AT&T will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customer’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customer’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box.
2.8.2.3.1 If NewPhone CLEC requests a UCSL and it is not available, NewPhone CLEC may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth AT&T inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneCLEC, BellSouth AT&T will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth AT&T will place cross-connect blocks in twenty five (25) pair increments for NewPhoneCLEC’s use on this cross-connect panel. NewPhone CLEC will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone CLEC shall install a cable to the BellSouth AT&T cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth AT&T technician within the BellSouth AT&T cross-box during the set-up process. NewPhoneCLEC’s cable pairs can then be connected to BellSouthAT&T’s USL within the BellSouth AT&T cross-box by the BellSouth AT&T technician.
2.8.2.6 Through the SI process, BellSouth AT&T will determine whether access to USLs at the location requested by NewPhone CLEC is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneCLEC’s request, then BellSouth AT&T will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxAT&T CLEC Online website.
2.8.2.7 The site set-up must be completed before NewPhone CLEC can order Subloop pairs. For the site set-up in a BellSouth AT&T cross-connect box in the field, BellSouth AT&T will perform the necessary work to splice NewPhoneCLEC’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth AT&T will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone CLEC will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone CLEC requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone CLEC for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouthAT&T’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone CCI requests a UCSL and it is not available, NewPhone CCI may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneCCI, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneCCI’s use on this cross-connect panel. NewPhone CCI will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone CCI shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneCCI’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone CCI is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneCCI’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone CCI can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneCCI’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone CCI will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone CCI requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone CCI for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone PLI requests a UCSL and it is not available, NewPhone PLI may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhonePLI, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhonePLI’s use on this cross-connect panel. NewPhone PLI will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone PLI shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhonePLI’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone PLI is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhonePLI’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone PLI can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhonePLI’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone PLI will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone PLI requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone PLI for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone MRC requests a UCSL and it is not available, NewPhone MRC may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneMRC, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneMRC’s use on this cross-connect panel. NewPhone MRC will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone MRC shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneMRC’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone MRC is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneMRC’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone MRC can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneMRC’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone MRC will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone MRC requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone MRC for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 2 contracts
Samples: Interconnection Agreement, Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Preferred requests a UCSL and it is not available, NewPhone Preferred may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhonePreferred, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhonePreferred’s use on this cross-connect panel. NewPhone Preferred will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Preferred shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhonePreferred’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Preferred is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhonePreferred’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Preferred can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhonePreferred’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Preferred will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Preferred requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Preferred for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Quality Telephone requests a UCSL and it is not available, NewPhone Quality Telephone may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneQuality Telephone, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneQuality Telephone’s use on this cross-connect panel. NewPhone Quality Telephone will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Quality Telephone shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneQuality Telephone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Quality Telephone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneQuality Telephone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Quality Telephone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneQuality Telephone’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Quality Telephone will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Quality Telephone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Quality Telephone for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone US LEC requests a UCSL and it is not available, NewPhone US LEC may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneUS LEC, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneUS LEC’s use on this cross-connect panel. NewPhone US LEC will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone US LEC shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneUS LEC’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone US LEC is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneUS LEC’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone US LEC can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneUS LEC’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone US LEC will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone US LEC requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone US LEC for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone INET requests a UCSL and it is not available, NewPhone INET may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneINET, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneINET’s use on this cross-connect panel. NewPhone INET will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone INET shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneINET’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone INET is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneINET’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone INET can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneINET’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone INET will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone INET requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone INET for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone BCFL requests a UCSL and it is not available, NewPhone BCFL may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneBCFL, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneBCFL’s use on this cross-connect panel. NewPhone BCFL will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone BCFL shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneBCFL’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone BCFL is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneBCFL’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone BCFL can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneBCFL’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone BCFL will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone BCFL requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone BCFL for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Grande requests a UCSL and it is not available, NewPhone Grande may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneGrande, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneGrande’s use on this cross-connect panel. NewPhone Grande will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Grande shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneGrande’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Grande is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneGrande’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Grande can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneGrande’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Grande will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Grande requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Grande for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone OnFiber requests a UCSL and it is not available, NewPhone OnFiber may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneOnFiber, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneOnFiber’s use on this cross-connect panel. NewPhone OnFiber will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone OnFiber shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneOnFiber’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone OnFiber is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneOnFiber’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone OnFiber can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneOnFiber’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone OnFiber will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone OnFiber requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone OnFiber for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Speedy Reconnect requests a UCSL and it is not available, NewPhone Speedy Reconnect may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneSpeedy Reconnect, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneSpeedy Reconnect’s use on this cross-connect panel. NewPhone Speedy Reconnect will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Speedy Reconnect shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneSpeedy Reconnect’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Speedy Reconnect is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneSpeedy Reconnect’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Speedy Reconnect can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneSpeedy Reconnect’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Speedy Reconnect will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Speedy Reconnect requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Speedy Reconnect for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Aero requests a UCSL and it is not available, NewPhone Aero may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneAero, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneAero’s use on this cross-connect panel. NewPhone Aero will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Aero shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneAero’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Aero is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneAero’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Aero can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneAero’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Aero will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Aero requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Aero for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Georgia Telephone requests a UCSL and it is not available, NewPhone Georgia Telephone may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneGeorgia Telephone, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneGeorgia Telephone’s use on this cross-connect panel. NewPhone Georgia Telephone will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Georgia Telephone shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneGeorgia Telephone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Georgia Telephone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneGeorgia Telephone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Georgia Telephone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneGeorgia Telephone’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Georgia Telephone will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Georgia Telephone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Georgia Telephone for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 28.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 28.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 28.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 28.2.4 If NewPhone Nexus requests a UCSL and it is not available, NewPhone Nexus may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 28.2.5 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 28.2.6 Upon request for USLD-INC from NewPhoneNexus, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneNexus’s use on this cross-connect panel. NewPhone Nexus will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 28.2.7 For access to Voice Grade USLD and UCSL, NewPhone Nexus shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneNexus’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 28.2.8 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Nexus is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneNexus’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 28.2.9 The site set-up must be completed before NewPhone Nexus can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneNexus’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 28.2.10 Once the site set-up is complete, NewPhone Nexus will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone Nexus requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Nexus for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 28.2.11 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Starlink requests a UCSL and it is not available, NewPhone Starlink may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneStarlink, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneStarlink’s use on this cross-connect panel. NewPhone Starlink will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Starlink shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneStarlink’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Starlink is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneStarlink’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Starlink can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneStarlink’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Starlink will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Starlink requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Starlink for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Home Telecom requests a UCSL and it is not available, NewPhone Home Telecom may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneHome Telecom, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneHome Telecom’s use on this cross-connect panel. NewPhone Home Telecom will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Home Telecom shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneHome Telecom’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Home Telecom is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneHome Telecom’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Home Telecom can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneHome Telecom’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Home Telecom will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Home Telecom requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Home Telecom for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Utility USA requests a UCSL and it is not available, NewPhone Utility USA may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneUtility USA, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneUtility USA’s use on this cross-connect panel. NewPhone Utility USA will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Utility USA shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneUtility USA’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Utility USA is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneUtility USA’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Utility USA can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneUtility USA’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Utility USA will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Utility USA requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Utility USA for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone FLATEL requests a UCSL and it is not available, NewPhone FLATEL may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneFLATEL, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneFLATEL’s use on this cross-connect panel. NewPhone FLATEL will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone FLATEL shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneFLATEL’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone FLATEL is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneFLATEL’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone FLATEL can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneFLATEL’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone FLATEL will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone FLATEL requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone FLATEL for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customer’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customer’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customer’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box.
2.8.2.3.1 If NewPhone TeraBlue requests a UCSL and it is not available, NewPhone TeraBlue may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneTeraBlue, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneTeraBlue’s use on this cross-connect panel. NewPhone TeraBlue will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone TeraBlue shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneTeraBlue’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone TeraBlue is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneTeraBlue’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone TeraBlue can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneTeraBlue’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone TeraBlue will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone TeraBlue requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone TeraBlue for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Freedom requests a UCSL and it is not available, NewPhone Freedom may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneFreedom, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneFreedom’s use on this cross-connect panel. NewPhone Freedom will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Freedom shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneFreedom’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Freedom is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneFreedom’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Freedom can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneFreedom’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Freedom will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Freedom requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Freedom for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Deland Actel requests a UCSL and it is not available, NewPhone Deland Actel may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneDeland Actel, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneDeland Actel’s use on this cross-connect panel. NewPhone Deland Actel will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Deland Actel shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneDeland Actel’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Deland Actel is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneDeland Actel’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Deland Actel can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneDeland Actel’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Deland Actel will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Deland Actel requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Deland Actel for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Charter requests a UCSL and it is not available, NewPhone Charter may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneCharter, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneCharter’s use on this cross-connect panel. NewPhone Charter will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Charter shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneCharter’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Charter is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneCharter’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Charter can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneCharter’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Charter will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Charter requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Charter for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an a customer’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customer’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customer’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box.
2.8.2.3.1 If NewPhone Global Dialtone requests a UCSL and it is not available, NewPhone Global Dialtone may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneGlobal Dialtone, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneGlobal Dialtone’s use on this cross-connect panel. NewPhone Global Dialtone will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Global Dialtone shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneGlobal Dialtone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Global Dialtone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneGlobal Dialtone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone Global Dialtone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneGlobal Dialtone’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Global Dialtone will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone Global Dialtone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Global Dialtone for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Clec Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Starlink requests a UCSL and it is not available, NewPhone Starlink may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneStarlink, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneStarlink’s use on this cross-connect panel. NewPhone Starlink will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Starlink shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneStarlink’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Starlink is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneStarlink’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone Starlink can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneStarlink’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Starlink will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone Starlink requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Starlink for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Clec Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Access Point requests a UCSL and it is not available, NewPhone Access Point may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneAccess Point, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneAccess Point’s use on this cross-connect panel. NewPhone Access Point will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Access Point shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneAccess Point’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Access Point is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneAccess Point’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Access Point can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneAccess Point’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Access Point will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Access Point requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Access Point for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone BTI requests a UCSL and it is not available, NewPhone BTI may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneBTI, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneBTI’s use on this cross-connect panel. NewPhone BTI will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone BTI shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneBTI’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone BTI is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneBTI’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone BTI can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneBTI’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone BTI will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone BTI requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone BTI for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Ring Connection requests a UCSL and it is not available, NewPhone Ring Connection may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneRing Connection, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneRing Connection’s use on this cross-connect panel. NewPhone Ring Connection will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Ring Connection shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneRing Connection’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Ring Connection is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneRing Connection’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Ring Connection can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneRing Connection’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Ring Connection will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Ring Connection requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Ring Connection for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone NationNET requests a UCSL and it is not available, NewPhone NationNET may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneNationNET, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneNationNET’s use on this cross-connect panel. NewPhone NationNET will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone NationNET shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneNationNET’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone NationNET is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneNationNET’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone NationNET can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneNationNET’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone NationNET will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone NationNET requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone NationNET for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Lightning requests a UCSL and it is not available, NewPhone Lightning may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneLightning, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneLightning’s use on this cross-connect panel. NewPhone Lightning will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Lightning shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneLightning’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Lightning is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneLightning’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Lightning can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneLightning’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Lightning will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Lightning requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Lightning for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Southern Telcom requests a UCSL and it is not available, NewPhone Southern Telcom may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneSouthern Telcom, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneSouthern Telcom’s use on this cross-connect panel. NewPhone Southern Telcom will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Southern Telcom shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneSouthern Telcom’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Southern Telcom is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneSouthern Telcom’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Southern Telcom can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneSouthern Telcom’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Southern Telcom will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Southern Telcom requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Southern Telcom for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone InterGlobe requests a UCSL and it is not available, NewPhone InterGlobe may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneInterGlobe, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneInterGlobe’s use on this cross-connect panel. NewPhone InterGlobe will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone InterGlobe shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneInterGlobe’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone InterGlobe is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneInterGlobe’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone InterGlobe can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneInterGlobe’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone InterGlobe will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone InterGlobe requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone InterGlobe for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 2.4.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 2.4.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 2.4.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 2.4.2.3.1 If NewPhone US South requests a UCSL and it is not available, NewPhone US South may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 2.4.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 2.4.2.4.1 Upon request for USLD-INC from NewPhoneUS South, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneUS South’s use on this cross-connect panel. NewPhone US South will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 2.4.2.5 For access to Voice Grade USLD and UCSL, NewPhone US South shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneUS South’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 2.4.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone US South is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneUS South’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 2.4.2.7 The site set-up must be completed before NewPhone US South can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneUS South’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 2.4.2.8 Once the site set-up is complete, NewPhone US South will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone US South requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone US South for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 2.4.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Birch requests a UCSL and it is not available, NewPhone Birch may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneBirch, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhone’s Xxxxx’x use on this cross-connect panel. NewPhone Birch will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Birch shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone’s Xxxxx’x cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Birch is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone’s Xxxxx’x request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Birch can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneBirch’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Birch will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Birch requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Xxxxx for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone South Carolina Net requests a UCSL and it is not available, NewPhone South Carolina Net may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneSouth Carolina Net, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneSouth Carolina Net’s use on this cross-connect panel. NewPhone South Carolina Net will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone South Carolina Net shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneSouth Carolina Net’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone South Carolina Net is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneSouth Carolina Net’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone South Carolina Net can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneSouth Carolina Net’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone South Carolina Net will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone South Carolina Net requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone South Carolina Net for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Xxxx requests a UCSL and it is not available, NewPhone Xxxx may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneXxxx, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhone’s Xxxx’x use on this cross-connect panel. NewPhone Xxxx will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Xxxx shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone’s Xxxx’x cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Xxxx is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone’s Xxxx’x request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Xxxx can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhone’s Xxxx’x cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Xxxx will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Xxxx requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Xxxx for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 22.2.1 The USLD facility is a dedicated transmission facility that BellSouth AT&T provides from an customerEnd User’s point of demarcation to a BellSouth an AT&T cross-connect device. The BellSouth AT&T cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth AT&T will make available the following subloop distribution offerings where facilities exist: exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 22.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 22.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-cross- box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 22.2.4 If NewPhone Dialog requests a UCSL and it is not available, NewPhone Dialog may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.UCSL.
2.8.2.4 22.2.5 USLD-INC is the distribution facility owned or controlled by BellSouth AT&T inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 22.2.6 Upon request for USLD-INC from NewPhoneDialog, BellSouth AT&T will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth AT&T will place cross-connect blocks in twenty five (25) pair increments for NewPhoneDialog’s use on this cross-connect panel. NewPhone Dialog will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 22.2.7 For access to Voice Grade USLD and UCSL, NewPhone Dialog shall install a cable to the BellSouth AT&T cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhone’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.Attachment
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Global Crossing requests a UCSL and it is not available, NewPhone Global Crossing may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneGlobal Crossing, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneGlobal Crossing’s use on this cross-connect panel. NewPhone Global Crossing will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Global Crossing shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneGlobal Crossing’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Global Crossing is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneGlobal Crossing’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Global Crossing can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneGlobal Crossing’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Global Crossing will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Global Crossing requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Global Crossing for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone ProNet requests a UCSL and it is not available, NewPhone ProNet may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneProNet, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneProNet’s use on this cross-connect panel. NewPhone ProNet will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone ProNet shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneProNet’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone ProNet is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneProNet’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone ProNet can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneProNet’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone ProNet will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone ProNet requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone ProNet for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Southern Digital requests a UCSL and it is not available, NewPhone Southern Digital may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneSouthern Digital, BellSouth will install a cross- connect panel in the building equipment room for the purpose of accessing USLD- INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneSouthern Digital’s use on this cross-connect panel. NewPhone Southern Digital will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Southern Digital shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneSouthern Digital’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Southern Digital is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneSouthern Digital’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone Southern Digital can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneSouthern Digital’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Southern Digital will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone Southern Digital requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Southern Digital for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone Universal Beepers requests a UCSL and it is not available, NewPhone Universal Beepers may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneUniversal Beepers, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-cross- connect blocks in twenty five (25) pair increments for NewPhoneUniversal Beepers’s use on this cross-connect panel. NewPhone Universal Beepers will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone Universal Beepers shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-set- up process. NewPhoneUniversal Beepers’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Universal Beepers is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneUniversal Beepers’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone Universal Beepers can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneUniversal Beepers’s cable into the cross-cross- connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone Universal Beepers will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone Universal Beepers requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Universal Beepers for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone DSL requests a UCSL and it is not available, NewPhone DSL may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneDSL, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneDSL’s use on this cross-connect panel. NewPhone DSL will be responsible for connecting its facilities to the twenty five (25) pair cross-cross- connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone DSL shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneDSL’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone DSL is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneDSL’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web sitesite address: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxxxxxx://xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/products/html/unes.html.
2.8.2.7 The site set-up must be completed before NewPhone DSL can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneDSL’s cable into the cross-connect box. For the site set-set- up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone DSL will request Subloop pairs through submission of a LSR form to the Local Carrier Service Center (LCSC). OC is required with USL pair provisioning when NewPhone DSL requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone DSL for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 2.4.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 2.4.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 2.4.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 2.4.2.3.1 If NewPhone Nexus requests a UCSL and it is not available, NewPhone Nexus may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 2.4.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 2.4.2.4.1 Upon request for USLD-INC from NewPhoneNexus, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneNexus’s use on this cross-connect panel. NewPhone Nexus will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 2.4.2.5 For access to Voice Grade USLD and UCSL, NewPhone Nexus shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhoneNexus’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 2.4.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone Nexus is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhoneNexus’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 2.4.2.7 The site set-up must be completed before NewPhone Nexus can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhoneNexus’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 2.4.2.8 Once the site set-up is complete, NewPhone Nexus will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone Nexus requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone Nexus for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 2.4.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 TR73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract
Samples: Interconnection Agreement
Unbundled Subloop Distribution (USLD). 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an customerEnd User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customerEnd User’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customerEnd User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer End User and the cross-box.
2.8.2.3.1 If NewPhone DeltaCom requests a UCSL and it is not available, NewPhone DeltaCom may request the copper Subloop facility be modified pursuant to the ULM process to remove load coils and/or excessive bridged taps. If load coils and/or excessive bridged taps are removed, the facility will be classified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customerEnd User’s premises.
2.8.2.4.1 Upon request for USLD-INC from NewPhoneDeltaCom, BellSouth will install a cross- cross-connect panel in the building equipment room for the purpose of accessing USLD- USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in twenty five (25) pair increments for NewPhoneDeltaCom’s use on this cross-connect panel. NewPhone DeltaCom will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, NewPhone shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. NewPhone’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will determine whether access to USLs at the location requested by NewPhone is technically feasible and whether sufficient capacity exists in the cross-box. If existing capacity is sufficient to meet NewPhone’s request, then BellSouth will perform the site set-up as described in the CLEC Information Package, located at BellSouth’s Interconnection Web site: xxx.xxxxxxxxxxxxxxx.xxxxxxxxx.xxx/xxxxxxxx/xxxx/xxxx.xxxx.
2.8.2.7 The site set-up must be completed before NewPhone can order Subloop pairs. For the site set-up in a BellSouth cross-connect box in the field, BellSouth will perform the necessary work to splice NewPhone’s cable into the cross-connect box. For the site set-up inside a building equipment room, BellSouth will perform the necessary work to install the cross-connect panel and the connecting block(s) that will be used to provide access to the requested USLs.
2.8.2.8 Once the site set-up is complete, NewPhone will request Subloop pairs through submission of a LSR form to the LCSC. OC is required with USL pair provisioning when NewPhone requests reuse of an existing facility, and the OC charge shall be billed in addition to the USL pair rate. For expedite requests by NewPhone for Subloop pairs, expedite charges will apply for intervals less than five (5) days.
2.8.2.9 USLs will be provided in accordance with BellSouth’s TR 73600 Unbundled Local Loop Technical Specifications.
Appears in 1 contract