Whereas, TECAN has developed a RSP (Robotic Sample Processor) which is
manufactured and sold to TRIPATH as `AUTOCYTE(R) PREP' PREPARATION SYSTEM,
hereinafter called "Product".
Whereas, TRIPATH will sell the Product worldwide under its name and its
Trademark with its sales force and through its distributors, but will sell
Product solely in combination with reagents.
Now, therefore, in consideration of the mutual covenants hereinafter expressed,
the parties agree as follows:
1/17
1. DEFINITIONS
1.1 "Product" means the `AUTOCYTE(R)PREP' PREPARATION SYSTEM, as
described in Exhibit A .
1.2 "Application" means the use of the Product, in particular the
QUAD-Arm (or direct derivatives), for the preparation of cytology or histology
samples for diagnostic purposes.
1.3 "Affiliate" shall mean any entity which directly or indirectly
controls, is controlled by or is under common control with another entity. For
purposes of this Agreement, an entity shall be deemed to be in control of
another entity if the former owns, or the partners of the former own, directly
or indirectly at least fifty percent (50%) of the outstanding voting equity (or
other equity or ownership interest in the event that such entity is other than a
corporation) of the latter.
2. MINIMAL QUANTATIES TO MAINTAIN EXCLUSIVITY
2.1 TECAN agrees not to offer directly on the basis of an Original
Equipment Manufacturing (OEM-) or Private Label (PL) Agreement to any third
party any device similar to the Product and intended for the Application,
provided that TRIPATH purchases the minimum number of Products specified during
this contract period ([*****] or such higher number as may have been notified by
TRIPATH in accordance with this paragraph). TRIPATH has to purchase a minimum of
[*****] Products during the contract period, and may purchase during the
contract period up to [*****] Products. TRIPATH will notify TECAN no later than
July 1, 2002, if it intends to purchase a higher number of Products (up to
[*****]) during the contract period.
TECAN must deliver the total number of Products as notified by TRIPATH
until December 31st, 2004, provided that TRIPATH has submitted orders in
accordance with this Agreement.
If TRIPATH orders less than its committed total number of Products
during the contract period but more than [*****], Tecan is entitled to charge
TRIPATH for costs for not purchased Products. Tecan is entitled to charge
TRIPATH CHF [*****] per Product up to the total number of Products committed by
TRIPATH pursuant to the last sentence of the first paragraph of this clause 2.1
but not purchased. For the avoidance of doubt, this charge of costs shall only
apply for Products not ordered in excess of [*****]; TRIPATH must in all cases
purchase a minimum of [*****] Products.
For the same number of Products not ordered, TECAN has to deliver the
specific parts. The specific parts include: all printed circuit boards, the
power supply transformer and the power supply.
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
2/17
TRIPATH has to purchase all remaining specific parts with one single
order before December 31st, 2004. Delivery and invoicing for these parts may be
scheduled by TECAN throughout 2005, with all parts to be delivered and invoiced
no later than December 31st, 2005.
2.2 TECAN hereby grants to TriPath a perpetual, license to copy,
distribute, perform, display, and create derivative works from the system
software related to and/or used in the Products. TECAN shall deliver to TRIPATH
the system software development tools and the source code at the termination of
this Agreement. TRIPATH shall not have any further rights against TECAN with
respect to the system software. TRIPATH assumes all responsibility for the
application software development, documentation (including operating manual),
installation and after sales support.
3. PURCHASE OF PRODUCT, QUANTITIES AND PRICING
3.1 Subject to the terms and conditions of this Agreement, TRIPATH
shall purchase, and TECAN shall sell to TRIPATH the Product. TRIPATH shall
purchase the Products hereunder at the price set forth in Exhibit B. A Product
is considered to be purchased during the Contract period in which the Product is
shipped from TECAN. Upgraded or repaired units shipped ex TECAN of Product do
not count as purchased during the contract period under this agreement.
3.4 For standard TECAN RSP 5000 Spare Parts TECAN will grant TRIPATH a
discount of [*****]% on International List Prices (ILP) (as set and revised by
TECAN at its sole discretion from time to time). No discount is applicable for
OEM specific Spare Parts (see Exhibit C).
3.5 For single orders for Spare Parts exceeding a total of CHF
[*****].-- TECAN will grant to TRIPATH an additional discount of [*****]% on the
ILP of both standard TECAN and OEM specific Spare Parts.
4. ORDERS AND DELIVERY, PAYMENT AND SHIPMENT
4.1 In the first month of each quarter, TRIPATH will forecast orders of
the Product for the following 12-month period (the Production Forecast). The
production Forecast is non-binding and to be used for planning purposes only,
and summarizes the next 12 months forecast activity. TRIPATH shall immediately
inform TECAN if it anticipates (or would reasonably have to anticipate) that it
will deviate significantly from the Production Forecast in its orders.
Products shall be ordered by means of a purchase order binding on
TRIPATH.
Each purchase order shall contain a description of the Products
ordered, quantity ordered, routing instructions, requested destination, delivery
date and confirmation price. Purchase orders may be sent by telegraph or fax.
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
3/17
No order will be binding on TECAN until it is accepted.
4.2 Payment shall be net in Swiss Francs (CHF) within 60 days from the
date of invoice. Delays in payment will result in simple interest of 8% per
annum.
4.3 The parties have agreed on the prices set forth herein based on an
exchange rate of CHF [daily rate at signing] / USD for 2002. Exchange rate
fluctuations between the CHF and USD will be checked twice annually on July 1
and December 31 of each contract year. If the average exchange rate for the
previous six months deviates more than 2.5% of the base exchange rate, such
difference (the whole difference) is split 50:50 by TRIPATH and TECAN and TECAN
shall invoice/issue credit note to TRIPATH of 50% of the difference on the
ordered and delivered Products semi-annually. For the calculation basis the
average exchange rate of the previous six months as published by a leading Swiss
bank as chosen by Tecan is used. A new base exchange rate will be specified as
the basis of payments for the next six months by the parties based on the
currency markets.
4.4 Product prices are quoted ex works. Shipping costs are quoted as
DDU (Delivered duty unpaid).
4.5 Delivery times:
4 weeks after receipt of TRIPATH's purchasing order, provided the
Production Forecast was made available and the purchase order is within the
forecasted figures.
16 weeks after receipt of TRIPATH's purchasing order if the above
proviso is not fulfilled.
4.6 Shipment of Product to TRIPATH, North Carolina is done via a
carrier selected by TECAN.
4.7 Freight charges of any other delivery to TRIPATH or any drop
shipment will be borne by TRIPATH. Title and risk of loss or damage of any items
delivered hereunder shall pass to TRIPATH upon delivery to the carrier pursuant
to the INCOTERM rules (2000).
5. PRODUCT CHANGES
5.1 Except if required by law, TECAN may not modify or update the
Product, spare parts or accessory material, without express written advance
consent by TRIPATH, which consent shall not unreasonably be withheld. All
proposed changes, having an effect on the functionality of the Product shall be
announced in writing to the Purchasing Manager at TRIPATH. In such cases,
TRIPATH shall have the right to reject the changes within 30 days, in writing,
with the exception of changes that are required by law. All changes should be
announced in advance.
5.2 Only changes accepted in writing by TRIPATH shall be added as an
amendment to the specification in Exhibit A.
4/17
5.3 Enhancements in the Product, spare parts and accessory materials
requested by TRIPATH are subject to TECAN's discretion and price policy.
6. QUALITY CONTROL
6.1 Every Product and spare part(s) shall be subject to a quality
control inspection by TECAN, which conforms to TRIPATH manufacturing QC
specifications as set forth in Exhibit D, and non-conforming products shall not
be shipped by TECAN. With each Product supplied the full quality control report
shall be shipped.
6.2 Each Product or spare part received by TRIPATH that fails incoming
inspection shall be returned to TECAN at TECAN's expense for repair or
replacement. TECAN will provide a written analysis within 30 days of receipt of
failed parts, defining the cause of the failure and any corrective action
implemented to prevent future failures.
7. INSTALLATION AND TRAINING
7.1 TRIPATH will install the Product and train customers of TRIPATH
with regard to the Product.
8. WARRANTY AND SERVICE
8.1. TECAN is an ISO 9001 certified Company.
8.2 TECAN warrants each Product for a period of fifteen (15) months
from the date of shipment or twelve (12) months from the date of installation at
a customer site, whichever period expires first. TECAN shall warrant that each
Product is free from defects in workmanship and materials and is manufactured in
conformity with the specifications set forth in Exhibit D.
TECAN warrants valves, tips, fittings, and syringes up to successful
installation by TRIPATH in a customer laboratory but in no event longer than for
a period of three months after shipment. If these parts fail after being in
contact with any potential biohazardous materials, TRIPATH will dispose of them
in accordance with appropriate procedures for handling potential biohazards, and
will not be returned to TECAN for failure analysis.
Tubing is excluded from any warranty, whether contractual or statutory.
If a Product or part of a Product covered by the aforementioned
warranty is found defective, TECAN shall, at its option, repair or replace the
defective Product or part of Product. TRIPATH shall not have any further
remedies. In particular, TECAN shall not be liable for any consequential
damages. TECAN's liability shall in any event be limited to the amount of the
purchase price of the respective Product. No warranties are made except as
explicitly stated in this clause 8, and any statutory or implied warranties are
disclaimed and excluded.
5/17
8.3 TECAN represents and warrants that Product, spare parts and
accessory materials shall be delivered free of any rights of any third party.
TECAN has good title to and has full power to sell Product, spare parts and
accessory materials to TRIPATH hereunder.
8.4 TECAN guarantees the delivery of spare parts for the Products sold
and delivered hereunder (except for unforeseeable quantities ordered) until
December 31st, 2007.
8.5 TRIPATH shall provide for sufficient insurance coverage against
third party claims and liabilities (including, but not limited, to product
liability and consequential damages).
8.6 Transportation costs for goods under warranty to and from TECAN
will be borne by TECAN. Transportation costs for repair goods to and from TECAN
will be borne by TRIPATH.
9. INDEMNIFICATION
9.1 In no event shall either party be liable to the other party
hereunder for any consequential, indirect or special damages.
9.2 TECAN does not assume any liability for damages resulting from
improper handling or installation or from disregard of operating requirements.
9.3 TECAN shall defend, indemnify and hold harmless TRIPATH for and
against all loss, liability and expense, including legal fees and disbursements,
court costs, and settlement payments actually incurred by TRIPATH as a result
of, arising out of or related to TECAN's breach of their respective
representations, warranties and covenants set forth in this Agreement provided,
however, that TECAN's obligation under this clause 9.3 shall in any event be
limited to the amount of the purchase price of the respective Product.
9.4 TRIPATH shall defend, indemnify and hold harmless TECAN for and
against all loss, liability and expense, including legal fees and disbursements,
court costs, and settlement payments actually incurred by TECAN as a result of,
arising out of or related to TRIPATH's breach of their respective
representations, warranties and covenants set forth in this Agreement. TRIPATH's
obligation under this clause 9.4 shall in any event be limited to the amount of
the purchase price of the respective Product.
10. TERM OF AGREEMENT AND TERMINATION
10.1 This Agreement shall commence on January 1st, 2002, and will
terminate December 31st, 2004, except for the sale and purchase of spare parts
for Products sold and delivered, for which the agreement shall run until
December 31, 2007 in accordance with clause 8.5.
10.2 Either Party to this Agreement ("Party") shall have the right to
terminate this Agreement effective immediately, without penalty, upon written
notice to the other Party in the event any of the following should occur:
6/17
(a) The other Party engages in fraudulent conduct;
(b) The other Party becomes insolvent; is adjudicated bankrupt; a
receiver, trustee or custodian is appointed for it; there is an assignment of
the other Party's business for the benefit of creditors; the other Party
liquidates or dissolves; or the occurrence of any action or event involving
either Party which is the equivalent of one or more of the events described in
this Section 10.2(b).
10.3 Other than for occurrences covered by Section 10.2 hereof, either
Party shall have the right to terminate this Agreement upon thirty (30) days
written notice if the other Party materially breaches or fails to perform any of
its obligations, representations or undertakings hereunder, and fails to cure
such breach or failure within such thirty (30) day notice period. In the event
that TRIPATH terminates this Agreement pursuant to this Section 10.3, the
requirements of the third paragraph of Section 2.1 shall not apply, and TRIPATH
shall have no payment obligation to TECAN except for Products delivered prior to
the effective date of any such termination.
10.4 TriPath shall have the right to terminate this Agreement on sixty
(60) days' prior written notice at its convenience. TRIPATH shall be liable for
payments accruing under the third paragraph of Section 2.1 in the event it
terminates this Agreement pursuant to this Section 10.4.
11. SETTLEMENTS OF DISPUTES
11.1 Both parties agree to reasonably try to settle any dispute arising
from this Agreement amicably. The right to pursue the proceeding set forth in
article 13.2 remains reserved.
12. MISCELLANEOUS PROVISIONS
12.1 All written notices and demands required or permitted to be given
or made pursuant to this Agreement shall be in English and shall be sent by
registered mail, or fax or courier addressed as follows:
If to TRIPATH: If to TECAN:
TRIPATH IMAGING. TECAN SCHWEIZ AG
000 Xxxxxxxxxx Xxxxx Xxxxxxxxxx 000
Xxxxxxxxxx, Xxxxx Xxxxxxxx 00000 8708 Mannedorf
USA SWITZERLAND
or to such other address as to which either party may advise the other
in writing that notices should be sent.
12.2 This Agreement shall be binding upon and relate to the benefit of
the parties hereto, their successors and assignees. This Agreement shall be
assignable by either party only with the prior written consent of the other,
except that either party may assign this Agreement without the consent of the
other to an Affiliate.
7/17
12.3 This Agreement supersedes all earlier agreements between TECAN and
TRIPATH or any of its predecessors regarding its subject matter.
12.4 Confidential Information. Either party may disclose to the other
party certain trade secret, proprietary or confidential information of the
disclosing party. Except as provided for in this Agreement or as otherwise
authorized by the disclosing party in writing, the receiving party will use such
information only for the purposes for which it is disclosed by the disclosing
party, will not disclose it to any third party and will take appropriate
reasonable steps to protect it from any unauthorized use or disclosure at least
as rigorous as those steps the receiving party takes to protect its own
confidential information. Collaborator will use the Results only in connection
with the applicable Research Project and will not publish or otherwise disclose
any Results to any third party without the prior written consent of TRIPATH.
13. GOVERNING LAW AND ARBITRATION CLAUSE
13.1 This Agreement shall be governed by, and construed in accordance
with, the laws of Switzerland, to the exclusion of the Swiss rules on conflicts
of laws and to the exclusion of the 1980 UN Convention on Contracts for the
International Sale of Goods.
13.2 Any disputes or controversies arising out of or in connection with
this Agreement, including disputes on its conclusion, binding effect, amendment
and termination, shall be resolved to the exclusion of the ordinary courts by a
three-person arbitral tribunal having its seat in Zurich, Switzerland in
accordance with the International Arbitration Rules of the Zurich Chamber of
Commerce. Each party shall appoint one arbitrator. Arbitration shall be
conducted in the English language.
Mannedorf, October 26, 2001 Burlington, November 1, 2001
TECAN Schweiz AG TRIPATH IMAGING, INC.
/s/ Xxxx Schrofner /s/ Xxxxx Xxxxxx /s/ Xxxxx X. Xxxxxxx
----------------------------------------- ---------------------------------
Xxxx Schrofner Xxxxx Xxxxxx Xxxxx X. Xxxxxxx
General Manager CFO Vice President, Operations
8/17
EXHIBIT A
PRODUCT
`AUTOCYTE(R)PREP' PREPARATION SYSTEM Part. No. 505 107 includes:
Description: Part Number:
1 Quad Arm 505225
1 1000 ul DiTi C option 505215
1 Additional 465 Dilutor 445003
4 5 ml syringes 300206
1 Autocyte Tubing Guide 505249
4 Pipette bundles 505230
1 CPU87 Board 520350
1 STEMO87 520351
1 POSU87 Board 520352
Liquid System
2 4 liter waste bottles 505255
1 Tube Vac - incl. Tubing 505248
Racks
1 Specimen Preparation Tray compl. 505250
Manuals
1 Operating Manual RSP 5000 - Series 390977
1 including Option 3.1 390205
1 Tubing plan 505251
1 AutoCyte Installation Report 390861
1 Autocyte Installation Procedure 390865
Following parts are in responsibility of TRIPATH and are therefore excluded from
`AUTOCYTE(R)PREP' PREPARATION SYSTEM Part. No. 505 107:
1 Waste station including: 505220
1 Tip rack ......
1 Waste / wash station 505222
1 Tip loading rack 505221
1 Base Plate 0552542.P0
4 Slide racks 505235
The `AUTOCYTE(R) PREP' system does not include the controlling PC, nor the
application software written in Integrator.
The `AUTOCYTE(R) PREP' PREPARATION SYSTEM is white including the safety guard
and instead of the TECAN-Logo the AUTOCYTE-Label is placed.
9/17
EXHIBIT B
Prices are valid within the period January 1st, 2002 until December 31st, 2004.
- `AUTOCYTE(R)PREP' System, TECAN P/N 505 107
Price per Unit in CHF [*****]
- Shipping costs
Transported units per order Transfer Price
per Unit in CHF
One unit per shipment [*****]
Two units per shipment [*****]
Three units per shipment [*****]
Four units per shipment [*****]
Five units and more per shipment [*****]
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
10/17
EXHIBIT C
Spare parts
Order No. Description Qty. Transfer Price
CHF
Spare Parts:
505 260 Preventive Maintenance kit 1 [*****]
505 250 Specimen Tray 1 [*****]
505 225 QUAD-Arm complete 1 [*****]
505 255 Waste Bottles for Vacuum System 1 [*****]
505 248 Tube Vac 1 [*****]
505 251 Tubing Kit complete 1 [*****]
505 227 1-4 Manifold on QUAD 1 [*****]
505 222 QUAD waste trough incl. elbow 1 [*****]
505 226 QUAD Tubing complete 1 [*****]
505 247 Vacuum Tubing Pump - Bottle 2 [*****]
505 246 Vacuum Tubing Bottle - IIII-Block 1 [*****]
505 249 Tubing Guide 1 [*****]
505 230 Tip Bundles 4 [*****]
503 350 Ball Slide 1 [*****]
503 351 BioHazard Disposal Bag (100 Pieces) 1 [*****]
503 352 Labels (BioHazard, Contaminated, Waste) 1 [*****]
503 307 Fuse board - CE version [*****]
503 329 Power module [*****]
503 330 Fan for board cage [*****]
503 331 Ferrit-flex cable-CE version [*****]
503 332 L-clamp-flex cable [*****]
503 333 Clamp plate-flex cable [*****]
503 334 Power Lamp [*****]
505 273 Z-rod (new Style DiTi) [*****]
505 274 Compensation Spring-Z motor [*****]
503 340 Motor w/longer shaft-Z [*****]
503 339 White plastic sleeve [*****]
503 336 Contact Switch CPL [*****]
503 338 Insulator block w/Spring [*****]
503337 Tubing Guide Assy [*****]
235 220 Adapter for Water Valve [*****]
505 271 Motor CPL [*****]
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
11/17
For following parts ILP - [*****]% is applicable ILP CHF
(International List
Price)
503 320 Y motor [*****]
503 321 Y belt [*****]
503 322 Idler pulley assy. Y belt [*****]
503 323 Drive pulley 10XL-Y motor [*****]
503 324 Pulley - Quad Arm Springs [*****]
503 325 Foot [*****]
503 319 Screw for X bearing [*****]
503 326 Idler pulley assy. -X belt [*****]
503 327 x-motor [*****]
503 325 On/Off switch-CE version [*****]
235 222 Metal Vacuum Adapter [*****]
520 366 RS 232 cable [*****]
552 483 DiTi spring loaded Z-Rack 1 [*****]
505 215 DiTi C 1000 ul RIAS complete 1 [*****]
320 002 Diluter 465/87 1 [*****]
445 003 Diluter 465/87 EMV CE 1 [*****]
520 350 CPU 87 1 [*****]
520 353 PONI/ALID left 1 [*****]
503 308 PONI/ALID left EMV CE 1 [*****]
530 360 FLEX-Cable left 1 [*****]
520 450 ARM left 1 [*****]
520 453 ARM left EMV CE 1 [*****]
520 355 Motherboard 1 [*****]
520 310 Motherboard EMV CE 1 [*****]
520 100 Option 3.1: Solenoid Valve Kit complete 1 [*****]
390 350 Operating Manual RSP 5051 1 [*****]
ILP is subject of change without notification.
Repair parts
(No discount)
Order No. Description Transfer Price
Repair Parts: CHF
R503308 Repair of PONI / ALID left CE version [*****]
R505215 Repair of XxXx XXXX Kit complete [*****]
R520350 Repair of CPU-87 Board [*****]
R520353 Repair of PONI/ALID 87 "LEFT" with cable [*****]
R520355 Repair of Motherboard 87 [*****]
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
12/17
R520450 Repair of arm LEFT [*****]
R520453 Repair of arm LEFT CE version [*****]
R520455 Repair of AutoCyte arm CE version [*****]
R320002 Repair of Diluter 465/87 [*****]
R445003 Repair of Diluter 465/87 EMV CE [*****]
R520351 Repair of STEMO -87 [*****]
R520351 Repair of Motherboard EMV CE [*****]
R503318 Repair of VADRI -87 [*****]
---------------
CONFIDENTIAL MATERIALS OMITTED AND FILED SEPARATELY WITH THE SECURITIES
AND EXCHANGE COMMISSION. ASTERISKS DENOTE SUCH OMISSIONS.
13/17
EXHIBIT D
FUNCTIONAL OBJECTIVES
SPECIMEN PREPARATION TRAY
The specimen preparation tray is used as a help to group sample vials,
centrifuge racks / tubes and slides etc. during manual sample preparation.
[SPECIMEN TRAY PICTURE]
The manual steps consist of:
1. Adding density gradient to centrifuge tube
2. Vortex sample vials
3. Insert Syringe into sample vial, obtain sample.
4. Insert Syringe / vial assembly into centrifuge tube, allow fluid to
drain
5. Place centrifuge tubes in centrifuge racks - centrifuge in Xxxxxxx
centrifuge
6. Remove supernatant with evacuator from centrifuge racks
7. Centrifuge again
REQUIREMENTS
- Slots for slides next to centrifuge rack receptacle.
- Finish: Aluminium, brushed, clear anodized.
INSTRUMENT
The base of the AutocytePrep System is a standard RSP 5051.
REQUIREMENTS
- Internal diluter (type 465) installed
- Both diluters equipped with 5000 ul syringes (4 pcs.)
- Additional DiTi 1000 ul, installed
14/17
QUAD
The QUAD arm is a permanent attachment to the RSP arm. Its purpose is to
dispense and aspirate (wash) the reagents and solvents in the settling xxxxxxxx.
The QUAD is lowered by the RSP Z-drive. The Z-drive is engaged in a special
Y-position. Special spring coils keep the QUAD in its home position.
REQUIREMENTS
- The QUAD holds four 5-tip bundles at fixed positions and the tubing.
- X/Y-accuracy must be better than +/- 1 mm (tested and adjusted with
alignment rack, see below).
- Liquid detection is not used when operating the QUAD.
- QUAD must have its own serial number.
The QUAD must allow the following alignments (required for tolerance
compensation):
1. Perpendicular (verticality)
2. Parallelism between QUAD tip carrier and worktable
3. Engagement position of RSP Z-drive.
4. Z-Height of individual tips
5. Y-position to worktable
[DIAGRAM]
DISPOSABLE TIPS
Currently used: Tips from USA Scientific Inc., Part no. 1112-2800.
VACUUM PUMP
The vacuum pump is supplied by TRIPATH IMAGING or its distributors.
15/17
TUBE EVACUATOR
The tube evacuator is used to remove the supernatant from the conical
centrifugation tubes after the first centrifugation. Prior to evacuation, DiTi's
are attached to the unit. For the device to operate properly, all ports must
have tips installed, even if fewer than 12 tips are being evacuated. The
evacuator is slowly lowered manually into the tubes. Tips must be changed for
the next evacuation.
[TUBE EVACUATOR PICTURE]
REQUIREMENTS
- Allows evacuating tubes which are placed in the Xxxxxxx centrifuge rack
- Uses different DiTi! (TRIPATH IMAGING order # 8000-240).
QUAD TUBING
Tubing dimensions of the Quad tubing: 1x2 mm and 2x3 mm, according to tubing
plan 505251 version 3.
LIQUID DETECTION
The liquid detection is not used at all. Instrument will lower tips to
predefined Z-levels. The ALID is only used to initialize the Z-axes.
CARRYOVER / TIP WASH
Sample carryover is assumed to be zero due to the use of disposable tips.
Carryover on QUAD tips is assumed to be negligible and of no significance.
MISCELLANEOUS HARDWARE
- Tubing guide
- Tubing gallows
- Manual
- Box including prints POSU, CPU and STEMO, 2 vacuum waste bottles
- Box 1 for accessories including Quad arm, 4 syringes 1000 ul, 2 tubing
(0x00x0000 mm), 2 tubing (8x14x900 mm), specimen preparation tray, tube
evacuator
- Box 2 for accessories including tubing for DiTi, z-bar, z-rod
engagement key, screws for Quad arm, DiTi, Screwdriver no. 2,
screwdriver no. 4, Xxxxx key set, label biohazard, label contaminated,
2 cables for the instrument and the computer, power cables USA
16/17
NOT INCLUDED
- Containers for solvents and reagents are not included in the system.
- Xxxxxxx centrifuge and the centrifuge tube racks are not included.
OTHER REQUIREMENTS
For the following parameters, the AUTOCYTEPREP SYSTEM has the same
specifications as the RSP 5051:
- Weight, volume, dimensions
- XYZ travel
- Speeds and accelerations (SW controlled by TRIPATH IMAGING)
- Positional resolution, step size, precision and accuracy
- Temperature range, humidity, noise
- Room requirements
- Chemical resistance
COLORS AND INDUSTRIAL DESIGN
- The instrument is TECAN white.
- Change the standard RSP 5000 type label to contain:
Model No.:
Serial No.:
Voltage:
Power:
Fuse:
PERSONNEL REQUIREMENTS
The operation of the AUTOCYTEPREP SYSTEM should only require training on the
instrument and the system. More over that, the user is expected to have basic
personal computer knowledge. One user is required to operate the instrument.
END USER SW
End user SW, based on the TECAN RSP 5000 INTEGRATOR, is written and maintained
by TRIPATH IMAGING. TRIPATH IMAGING takes full responsibility for its
application SW.
ACCEPTANCE CRITERIA
The following tests will be done by Tecan on each instrument: QC-test, Random
test, Voltage test.
QC-TEST
The QC test shall cover the following points(see detailed description under
Tecan doc. no. 390 854):
- Liquid system test
- Vacuum and Quad test
- Random system test
- Random test Quad arm
- Wet test
- Tip handling test
- z-rod test
- contact spring test
17/17