AMENDMENT NO.1 TO THE STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONSTRUCTION MANAGER WHERE THE CONSTRUCTION MANAGER IS ALSO THE CONSTRUCTOR (AIA A121/CMc) BETWEEN THE OWNER: NATIONAL RURAL UTILITIES COOPERATIVE FINANCIAL CORPORATION AND THE...
Amendment No.1 to Agreement Between Owner and Construction Manager
NRUCFC Corporate Headquarters Facility
AMENDMENT NO.1
TO THE
CONSTRUCTION MANAGER IS ALSO THE CONSTRUCTOR
(AIA A121/CMc)
BETWEEN THE OWNER: NATIONAL RURAL UTILITIES COOPERATIVE FINANCIAL CORPORATION
AND THE
CONSTRUCTION MANAGER: THE XXXXXXX-XXXXXX CONTRACTING COMPANY
FOR:
NRUCFC CORPORATE HEADQUARTERS FACILITY
CONTRACT DATED: AUGUST 26, 2009
AMENDMENT NUMBER 1 FOR NRUCFC HEADQUARTERS OFFICE BUILDING
AMENDMENT DATED May 17, 2010
EXHIBT A - LIST OF CONTRACT DOCUMENTS
EXHIBIT B - ASSUMPTIONS & CLARIF1CATIONS TO THE GMP
EXHIBIT C - ALLOWANCE ITEMS
EXHIBIT D - SCHEDULE OF VALUES
EXHIBIT E - SCOPE OF WORK
EXHIBIT F - SCHEDULE
This Amendment to the Agreement entered into as of the day and year first written above.
OWNER | CONSTRUCTION MANAGER |
National Rural Utilities Cooperative Finance Corporation | The Xxxxxxx-Xxxxxx Contracting Comapany |
/s/ XXXX X. XXXXX | /s/ X.X.Xxxxx |
Xxxx X. Xxxxx, Senior Vice President | X.X. Xxxxx, Division Vice President |
EXHIBIT A
LIST OF CONTRACT DOCUMENTS
May 17, 2010
Miscellaneous Contract Documents:
·
|
Addendum No. I Dated November 13, 2009 issued by KGD
|
·
|
Addendum No.2 Dated March 5, 2010 issued by KGD
|
Contract Drawing List:
Main Site Design Drawings prepared by Xxxxxxxx.
Dwg.#
|
Drawing Title
|
Date
|
Discipline
|
C1
|
Coversheet
|
03/05/2010
|
Civil
|
C2
|
Index Sheet
|
5/28/2009
|
Civil
|
C3
|
Construction Details
|
01/15/2010
|
Civil
|
C4
|
Grading Plan
|
01/08/2010
|
Civil
|
C5
|
Grading Plan
|
2/24/2010
|
Civil
|
C6
|
Grading Plan
|
01/08/2010
|
Civil
|
C7
|
Utility and Labeling Plans
|
02/24/2010
|
Civil
|
C8
|
Utility and Labeling Plans
|
01/08/2010
|
Civil
|
C9
|
Erosion & Sediment Control Narrative
|
05/28/2009
|
Civil
|
C10
|
Erosion & Sediment Control Details
|
05/28/2009
|
Civil
|
C11
|
Erosion & Sediment Control Phase I
|
01/13/2010
|
Civil
|
C12
|
Erosion & Sediment Control Phase I
|
01/13/2010
|
Civil
|
C12A
|
Erosion & Sediment Control Phase I
|
05/28/2009
|
Civil
|
C13
|
Erosion & Sediment Control Phase II
|
01/13/2010
|
Civil
|
C14
|
Erosion & Sediment Control Phase II
|
01/13/2010
|
Civil
|
C14A
|
Erosion & Sediment Control Phase II
|
05/28/2009
|
Civil
|
C15
|
Storm Sewer Profiles
|
01/20/2010
|
Civil
|
C16
|
Storm Sewer Computations and Details
|
01/18/2010
|
Civil
|
C17
|
Sanitary Sewer & Watermain Profiles and Computations
|
12/11/2009
|
Civil
|
C18
|
Storm Water Management Computations
|
10/01/2009
|
Civil
|
C19
|
Storm Water Management Computations
|
10/01/2009
|
Civil
|
C20
|
Storm Water Management Computations
|
10/01/2009
|
Civil
|
C21
|
Storm Water Management Computations Pond #1
|
03/01/2010
|
Civil
|
C22
|
Storm Water Management Computations Pond #1
|
03/01/2010
|
Civil
|
C23
|
Storm Water Management Computations Pond #1
|
03/01/2010
|
Civil
|
C24
|
Storm Water Management Computations Area #2
|
5/28/2009
|
Civil
|
C25
|
Storm Water Management Computations Area #4
|
07/01/2009
|
Civil
|
C26
|
Storm Water Management Computations Area #5
|
07/01/2009
|
Civil
|
C27
|
Geotechnical Information
|
07/09/2009
|
Civil
|
C28
|
Lighting Details
|
09/2008
|
Civil
|
C29
|
Lighting Details
|
09/2008
|
Civil
|
C30
|
Lighting Details
|
05/28/2009
|
Civil
|
C31
|
Approved CPAP-1994-0081
|
07/15/2008
|
Civil
|
C32
|
Approved CPAP-1994-0081
|
07/15/2008
|
Civil
|
C33
|
Approved CPAP-1994-0081
|
07/15/2008
|
Civil
|
C34
|
Approved CPAP-1994-0081
|
9/2008
|
Civil
|
C35
|
Loudoun Sanitary Sewer Details
|
9/2008
|
Civil
|
C36
|
Loudoun Sanitary Sewer Details
|
9/2008
|
Civil
|
C37
|
Loudoun Sanitary Main Details
|
9/2008
|
Civil
|
C38
|
Loudoun Sanitary Main Details
|
9/2008
|
Civil
|
C39
|
Loudoun Sanitary Main Details
|
9/2008
|
Civil
|
C39A
|
Loudoun Water Reclaimed Water Water Main Details
|
9/2008
|
Civil
|
C39B
|
Loudoun Water Reclaimed Water Water Main Details
|
9/2008
|
Civil
|
C39C
|
Loudoun Water Reclaimed Water Water Main Details
|
9/2008
|
Civil
|
C40
|
Landscape Plan
|
06/09/2009
|
Civil
|
C41
|
Landscape Plan
|
06/09/2009
|
Civil
|
C42
|
Landscape Plan
|
07/14/2009
|
Civil
|
C43
|
Plant Schedule and Calculations
|
07/14/2009
|
Civil
|
C44
|
Tree Preservation Plan
|
07/30/2009
|
Civil
|
C45
|
Tree Preservation Plan
|
06/05/2009
|
Civil
|
C46
|
Tree Preservation Plan
|
06/05/2009
|
Civil
|
C47
|
Tree Preservation Plan
|
07/30/2009
|
Civil
|
C48
|
Tree Preservation Plan
|
06/05/2009
|
Civil
|
C49
|
Site Lighting & Fire Lane Sign Location Plan
|
01/08/2010
|
Civil
|
C50
|
Site Lighting & Fire Lane Sign Location Plan
|
01/08/2010
|
Civil
|
C51
|
Electrical Site Lighting Key Plan Sheet 1 / Photometric Plan
|
04/06/2009
|
Civil
|
C52
|
Electrical Site Lighting Plan Sheet 1/ Photometric Plan
|
04/06/2009
|
Civil
|
C53
|
Electrical Site Lighting Plan Sheet 2/ Photometric Plan
|
04/06/2009
|
Civil
|
C54
|
Electrical Site Lighting Plan Sheet3/ Photometric Plan
|
04/06/2009
|
Civil
|
C55
|
Electrical Site Lighting Plan Sheet 4/ Photometric Plan
|
01/08/2010
|
Civil
|
C55
|
Pavement Map
|
10/20/2009
|
Civil
|
C56
|
Electrical Site Lighting Plan Sheet 5 (Removed)
|
03/05/2010
|
Civil
|
C57
|
Existing Potomac Interceptor Sewer Exhibit
|
09/2008
|
Civil
|
Design Drawings issued by Xxxxxxxxx Xxxxxx and Xxxxxx PC (KGD) Architecture.
Prepared by KGD, Fox, Xxxxx+Xxxxx, SK&A, and Others
Dwg#
|
Drawing Title
|
Date
|
Discipline
|
A.0
|
Cover Sheet Volume I
|
10/23/2009
|
Architectural
|
A.0
|
Cover Sheet Volume II
|
10/23/2009
|
Architectural
|
A.000A
|
Index Sheet Volume I
|
03/05/2010
|
Architectural
|
A.00B
|
Index Sheet Volume II
|
03/05/2010
|
Architectural
|
A.001
|
Abbreviations, Svmbols, Notes and Graphics
|
10/23/2009
|
Architectural
|
A.002
|
Code Analysis
|
10/23/2009
|
Architectural
|
A.002A
|
Egress Diagrams
|
03/05/2010
|
Architectural
|
A.003A
|
Base Building Partition Types
|
03/05/2010
|
Architectural
|
A.004
|
UL Standards
|
10/23/2009
|
Architectural
|
A.005
|
Base Building Door Types
|
03/05/2010
|
Architectural
|
A.006
|
Base Building Door Schedule
|
03/05/2010
|
Architectural
|
A.006A
|
Base Building Hardware Schedule
|
03/05/2010
|
Architectural
|
A.007
|
Finish Schedule
|
10/23/2009
|
Architectural
|
A.008
|
Finish Schedule
|
03/05/2010
|
Architectural
|
TP-1
|
Tree Preservation Plan (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-2
|
Tree Preservation Plan (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-3
|
Tree Preservation Plan (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-4
|
Tree Preservation Plan (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-5
|
Tree Preservation Plan (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-6
|
Tree Preservation Details and Notes (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
TP-7
|
Tree Preservation Details and Notes (As Previously Submitted)
|
04/06/2009
|
Landscaping
|
L.100
|
Key Plan
|
03/05/2010
|
Landscaping
|
L.201
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.202
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.203
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.204
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.205
|
Layout and Materials Plan Enlargement (AS Previously Submitted)
|
04/06/2009
|
Landscaping
|
L.301
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.302
|
Layout and Materials Plan Enlargement
|
03/05/2010
|
Landscaping
|
L.303
|
Landscape Fine Grading Plan
|
03/05/2010
|
Landscaping
|
L.501
|
Site Details
|
03/05/2010
|
Landscaping
|
L.502
|
Site Details
|
03/05/2010
|
Landscaping
|
L.503
|
Site Details
|
03/05/2010
|
Landscaping
|
LI.100
|
Irrigation Notes
|
03/05/2010
|
Landscaping
|
LI.101
|
Irrigation Plan
|
03/05/2010
|
Landscaping
|
LI.102
|
Irrigation Plan
|
03/05/2010
|
Landscaping
|
LI.103
|
Irrigation Plan
|
03/05/2010
|
Landscaping
|
LI.501
|
Irrigation Details
|
03/05/2010
|
Landscaping
|
LI.502
|
Irrigation Details
|
03/05/2010
|
Landscaping
|
LP.100
|
Planting Key Plan and Schedule
|
03/05/2010
|
Landscaping
|
LP.101
|
Overstory Planting Plan
|
03/05/2010
|
Landscaping
|
LP.102
|
Entry Drive Planting Plan
|
03/05/2010
|
Landscaping
|
LP.103
|
Groundplane Planting. Plan
|
03/05/2010
|
Landscaping
|
LP.201
|
Planting Plan Enlargement
|
03/05/2010
|
Landscaping
|
LP.202
|
Planting, Plan Enlargement
|
03/05/2010
|
Landscaping
|
LP.203
|
Planting. Plan Enlargement
|
10/23/2009
|
Landscaping
|
LP.501
|
Planting Details
|
10/23/2009
|
Landscaping
|
A.101
|
Architectural Site Plan
|
03/05/2010
|
Architectural
|
A.110
|
First Floor Slab Edge Plan
|
03/05/2010
|
Architectural
|
A.111
|
Second Floor Edge Slab Plan
|
03/05/2010
|
Architectural
|
A.112
|
Third Floor Slab Edge Plan
|
03/05/2010
|
Architectural
|
A.113
|
Lower Roof Slab Edge Plan
|
03/05/2010
|
Architectural
|
A.114
|
Upper Roof Slab Edge Plan
|
10/23/2009
|
Architectural
|
A.115
|
Slab Edge Details
|
03/05/2010
|
Architectural
|
A.200
|
First Floor Plan
|
03/05/2010
|
Architectural
|
A.201
|
Second Floor Plan
|
03/05/2010
|
Architectural
|
A.202
|
Third Floor Plan
|
03/05/2010
|
Architectural
|
A.203
|
Lower Roof Plan
|
03/05/2010
|
Architectural
|
A.204
|
Upper Roof Plan
|
03/05/2010
|
Architectural
|
A.205
|
Shaft Roof Plans
|
03/05/2010
|
Architectural
|
A.210
|
Enlarged Lobby Floor Plan
|
03/05/2010
|
Architectural
|
A.211
|
Enlarged Atrium First Floor Plan
|
10/23/2009
|
Architectural
|
A.212
|
Enlarged Atrium Second Floor Plan
|
10/23/2009
|
Architectural
|
A.213
|
Enlarged Atrium Third Floor Plan
|
10/23/2009
|
Architectural
|
A.2l4
|
Enlarged Restroom Plans
|
03/05/2010
|
Architectural
|
A.215
|
Enlarged Restroom Plans
|
10/23/2009
|
Architectural
|
A.216
|
Enlarged Plans
|
10/23/2009
|
Architectural
|
A.217
|
Enlarged Floor Plans
|
03/05/2010
|
Architectural
|
A.218
|
Enlarged Dome Plan/Section
|
03/05/2010
|
Architectural
|
A.220
|
Enlarged Loading. Dock Plan
|
03/05/2010
|
Architectural
|
A.221
|
Enlarged Loading, Dock Roof Plan
|
03/05/2010
|
Architectural
|
A.225
|
Generator Building
|
03/05/2010
|
Architectural
|
A.226
|
Generator Enclosure Details
|
03/05/2010
|
Architectural
|
A.227
|
Landscape Pavilion
|
03/05/2010
|
Architectural
|
A.227A
|
Landscape Pavilion
|
10/23/2009
|
Architectural
|
A.227D
|
Landscape Pavilion
|
03/05/2010
|
Architectural
|
A.228A
|
Storage Facility
|
03/05/2010
|
Architectural
|
A.228B
|
Storage Facility Elevations
|
03/05/2010
|
Architectural
|
A.228C
|
Storage Facility Sections
|
03/05/2010
|
Architectural
|
A.228D
|
Storage Facility Details
|
03/05/2010
|
Architectural
|
A.229
|
Mock Up Wall
|
03/05/2010
|
Architectural
|
A.230
|
First Floor Finish Plan
|
03/05/2010
|
Architectural
|
A.231
|
Second Floor Finish Plan
|
10/23/2009
|
Architectural
|
A.232
|
Third Floor Finish Plan
|
10/23/2009
|
Architectural
|
A.233
|
Enlarged Lobby Finish Plan
|
10/23/2009
|
Architectural
|
A.234
|
Enlarged Atrium Finish Plan
|
03/05/2010
|
Architectural
|
A.235
|
Enlarged Restroom Finish Plans
|
10/23/2009
|
Architectural
|
A.236
|
Enlarged Restroom Finish Plans
|
10/23/2009
|
Architectural
|
A.237
|
Enlarged Restroom Finish Plans
|
03/05/2010
|
Architectural
|
A.240
|
First Floor Reflected Ceiling Plan
|
03/05/2010
|
Architectural
|
A.241
|
Second Floor Reflected Ceiling Plan
|
03/05/2010
|
Architectural
|
A.242
|
Third Floor Reflected Ceiling Plan
|
03/05/2010
|
Architectural
|
A.243
|
Enlarged Lobby Reflected Ceiling Plan
|
10/23/2009
|
Architectural
|
A.244
|
Enlarged Atrium First Floor Reflected Ceiling. Plan
|
10/23/2009
|
Architectural
|
A.245
|
Enlarged Atrium Second Floor Reflected Ceiling Plan
|
10/23/2009
|
Architectural
|
A.246
|
Enlarged Atrium Third Floor Reflected Ceiling Plan
|
10/23/2009
|
Architectural
|
A.247
|
Enlarged Roof Lighting, Plan
|
10/23/2009
|
Architectural
|
A.248A
|
Enlarged Restroom Reflected Ceiling Plans
|
10/23/2009
|
Architectural
|
A.248B
|
Enlarged Restroom Reflected Ceiling Plans
|
10/23/2009
|
Architectural
|
A.249
|
Loading Dock, Mechanical. & Penthouse RCP
|
03/05/2010
|
Architectural
|
A.250
|
First Floor Device Plan
|
03/05/2010
|
Architectural
|
A.25l
|
Second Floor Device Plan
|
03/05/2010
|
Architectural
|
A.252
|
Third Floor Device Plan
|
10/23/2009
|
Architectural
|
A.260
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.261
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.262
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.263
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.264
|
Enlarged Partial Plans
|
10/23/2009
|
Architectural
|
A.265
|
Enlarged Partial Plans
|
10/23/2009
|
Architectural
|
A.266
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.267
|
Enlarged Partial Plans
|
03/05/2010
|
Architectural
|
A.270
|
Plan Details
|
03/05/2010
|
Architectural
|
A.271
|
Plan Details
|
10/23/2009
|
Architectural
|
A.272
|
Plan Details
|
03/05/2010
|
Architectural
|
A.273
|
Plan Details
|
03/05/2010
|
Architectural
|
A.274
|
Plan Details
|
03/05/2010
|
Architectural
|
A.275
|
Plan Details
|
10/23/2009
|
Architectural
|
A.277
|
Plan Details
|
03/05/2010
|
Architectural
|
A.301
|
East Elevation
|
03/05/2010
|
Architectural
|
A.302
|
South Elevation
|
03/05/2010
|
Architectural
|
A.303
|
North Elevation
|
03/05/2010
|
Architectural
|
A.304
|
West Elevation
|
10/23/2009
|
Architectural
|
A.305
|
Courtyard Elevation
|
10/23/2009
|
Architectural
|
A.320
|
Enlarged Elevation
|
10/23/2009
|
Architectural
|
A.321
|
Enlarged Elevation
|
03/05/2010
|
Architectural
|
A.322
|
Enlarged Elevation
|
10/23/2009
|
Architectural
|
A.323
|
Enlarged Elevation
|
10/23/2009
|
Architectural
|
A.324
|
Enlarged Partial Elevations
|
03/05/2010
|
Architectural
|
A.325
|
Enlarged Partial Elevation
|
10/23/2009
|
Architectural
|
A.326
|
Enlarged Partial Elevations
|
03/05/2010
|
Architectural
|
A.327
|
Enlarged Partial Elevations
|
03/05/2010
|
Architectural
|
A.328
|
Enlarged Partial Elevations
|
10/23/2009
|
Architectural
|
A.329
|
Enlarged Partial Elevations
|
03/05/2010
|
Architectural
|
A.330
|
Enlarged Partial Elevations
|
10/23/2009
|
Architectural
|
A.341
|
Loading Dock Elevations
|
03/05/2010
|
Architectural
|
A.351
|
Elevation Details
|
03/05/2010
|
Architectural
|
A.401
|
Building Sections
|
10/23/2009
|
Architectural
|
A410
|
Wall Sections
|
03/05/2010
|
Architectural
|
A.41l
|
Wall Sections
|
03/05/2010
|
Architectural
|
A.412
|
Wall Sections
|
10/23/2009
|
Architectural
|
A.413
|
Wall Sections
|
10/23/2009
|
Architectural
|
A.414
|
Wall Sections
|
10/23/2009
|
Architectural
|
A.415
|
Wall Sections
|
03/05/2010
|
Architectural
|
A.416
|
Wall Sections
|
10/23/2009
|
Architectural
|
A.4l7
|
Atrium Wall Section
|
10/23/2009
|
Architectural
|
A.4l9
|
Wall Sections
|
03/05/2010
|
Architectural
|
A.430
|
Section Details
|
03/05/2010
|
Architectural
|
A.431
|
Section Details
|
03/05/2010
|
Architectural
|
A.432
|
Section Details
|
03/05/2010
|
Architectural
|
A.433
|
Section Details
|
03/05/2010
|
Architectural
|
A.434
|
Section Details
|
03/05/2010
|
Architectural
|
A.435
|
Section Details
|
03/05/2010
|
Architectural
|
A.436
|
Section Details
|
03/05/2010
|
Architectural
|
A.437
|
Section Details
|
03/05/2010
|
Architectural
|
A.438
|
Section Details
|
03/05/2010
|
Architectural
|
A.440
|
Typical Wall Section Details
|
03/05/2010
|
Architectural
|
A.441
|
Typical Wall Section Details
|
03/05/2010
|
Architectural
|
A.444
|
Misc Details
|
03/05/2010
|
Architectural
|
A.445
|
Typical Section Details
|
03/05/2010
|
Architectural
|
A.446
|
3D sections and Axonometrics
|
10/23/2009
|
Architectural
|
A.447
|
Misc. Details
|
03/05/2010
|
Architectural
|
AA50
|
Misc. Details
|
03/05/2010
|
Architectural
|
A.451
|
Roof Details
|
10/23/2009
|
Architectural
|
A.452
|
Roof Details
|
03/05/2010
|
Architectural
|
A.453
|
Typical Details at Dome and Flat Roofs
|
03/05/2010
|
Architectural
|
A.455
|
Misc. Details
|
03/05/2010
|
Architectural
|
A.456
|
Misc. Details
|
10/23/2009
|
Architectural
|
A.46l
|
Windows Details
|
03/05/2010
|
Architectural
|
A.462
|
Windows Details
|
10/23/2009
|
Architectural
|
A.463
|
Window Details
|
03/05/2010
|
Architectural
|
A.501
|
Enlarged Egress Stair Plans
|
03/05/2010
|
Architectural
|
A.502
|
Enlarged Egress Stair Sections
|
03/05/2010
|
Architectural
|
A.503
|
Egress Stair Details
|
03/05/2010
|
Architectural
|
A.504
|
Egress Stair Details
|
03/05/2010
|
Architectural
|
A.505
|
Enlarged Egress Stair Finish Plan
|
10/23/2009
|
Architectural
|
A.510
|
Enlarged Lobby Stair Plans & Stair Sections
|
11/13/2009
|
Architectural
|
A.511
|
Stair Elevations
|
10/23/2009
|
Architectural
|
A.512
|
Stair Details
|
03/05/2010
|
Architectural
|
A.513
|
Stair and Rail Details
|
10/23/2009
|
Architectural
|
A.520
|
Enlarged Atrium Stair Plan
|
10/23/2009
|
Architectural
|
A.521
|
Enlarged Atrium Stair Plans & Sections
|
10/23/2009
|
Architectural
|
A.522
|
Atrium Stair Details
|
03/05/2010
|
Architectural
|
A.530
|
Enlarged Elevator Plans and Sections
|
03/05/2010
|
Architectural
|
A.531
|
Stair Sections
|
03/05/2010
|
Architectural
|
A.540
|
Enlarged Elevator Plans and Sections
|
11/13/2009
|
Architectural
|
A.541
|
Elevator Enclosure Elevations
|
03/05/2010
|
Architectural
|
A.542
|
Enlarged Elevator Plans & Elevations
|
10/23/2009
|
Architectural
|
A.543
|
Enlarged Elevator Details
|
10/23/2009
|
Architectural
|
A.702
|
Interior Corridor Elevations
|
10/23/2009
|
Architectural
|
A.703
|
Interior Atrium Elevations
|
10/23/2009
|
Architectural
|
A.704
|
Interior Atrium Elevations
|
10/23/2009
|
Architectural
|
A.705
|
Interior Atrium Elevations
|
10/23/2009
|
Architectural
|
A.706
|
Interior Atrium Elevations
|
10/23/2009
|
Architectural
|
A.707
|
Atrium Wall Sections
|
10/23/2009
|
Architectural
|
A.708
|
Atrium Details
|
10/23/2009
|
Architectural
|
A.709
|
Atrium Details
|
10/23/2009
|
Architectural
|
A.710
|
Coiling Door Enlarged Plans
|
10/23/2009
|
Architectural
|
A.712
|
Lobby Elevations
|
03/05/2010
|
Architectural
|
A.713
|
Lobby Elevations
|
03/05/2010
|
Architectural
|
A.714
|
Lobby Elevation
|
03/05/2010
|
Architectural
|
A.715
|
Lobby Wall Sections
|
10/23/2009
|
Architectural
|
A.716
|
Lobby Wall Sections
|
10/23/2009
|
Architectural
|
A.717
|
Lobby Details
|
10/23/2009
|
Architectural
|
A.718
|
Lobby Details
|
10/23/2009
|
Architectural
|
A.719
|
Lobby Details
|
10/23/2009
|
Architectural
|
A.730
|
Bathroom Elevations
|
10/23/2009
|
Architectural
|
A.731
|
Bathroom Elevations
|
10/23/2009
|
Architectural
|
A.732
|
Bathroom Elevations
|
10/23/2009
|
Architectural
|
A.733
|
Bathroom Elevations
|
03/05/2010
|
Architectural
|
A.734
|
Elevations
|
10/23/2009
|
Architectural
|
A.735
|
Restroom Details and Sections
|
10/23/2009
|
Architectural
|
A.736
|
Details and Sections
|
10/23/2009
|
Architectural
|
A.737
|
Coffee Bar Sections
|
10/23/2009
|
Architectural
|
A.738
|
Enlarged Lobby Details
|
03/05/2010
|
Architectural
|
A.801
|
Bridge Architectural Site Plan and Vicinity
|
11/13/2009
|
Architectural
|
A.821
|
Bridge Plans
|
11/13/2009
|
Architectural
|
A.831
|
Bridge Elevations
|
11/13/2009
|
Architectural
|
A.841
|
Bridge Details
|
11/13/2009
|
Architectural
|
A.842
|
Bridge Details
|
11/13/2009
|
Architectural
|
VT.01
|
Elevator Diagrams
|
10/23/2009
|
Elevator
|
VT.02
|
Elevator Diagrams
|
10/23/2009
|
Elevator
|
IA0.01
|
General Notes & Symbols
|
03/05/2010
|
Interior Architectural
|
IA1.00
|
Partition Plan Cover Sheet
|
03/05/2010
|
Interior Architectural
|
IA1.00A
|
Door Schedules
|
03/05/2010
|
Interior Architectural
|
IA1.00B
|
Hardware Schedule
|
03/05/2010
|
Interior Architectural
|
IA1.01
|
1st Floor Partition Plan
|
03/05/2010
|
Interior Architectural
|
IA1.02
|
2nd Floor Partition Plan
|
03/05/2010
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Partition Plan
|
03/05/2010
|
Interior Architectural
|
IA2.00
|
Reflected Ceiling Plan Cover Sheet
|
03/05/2010
|
Interior Architectural
|
IA2.01
|
1st Floor Reflected Ceiling Plan
|
03/05/2010
|
Interior Architectural
|
IA2.02
|
2nd Floor Reflected Ceiling Plan
|
03/05/2010
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Reflected Ceiling Plan
|
03/05/2010
|
Interior Architectural
|
IA3.00
|
Telephone/Data/Electric Cover Sheet
|
03/05/2010
|
Interior Architectural
|
IA3.01
|
1st Floor Telephone/Data/Elec Plan
|
03/05/2010
|
Interior Architectural
|
IA3.02
|
2nd Floor Telephone/Data/Elec Plan
|
03/05/2010
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Telephone/Data/Elec Plan
|
03/05/2010
|
Interior Architectural
|
IA4.00
|
Finish Plan General Notes
|
03/05/2010
|
Interior Architectural
|
IA4.01
|
1st Floor Finish Plan
|
03/05/2010
|
Interior Architectural
|
IA4.02
|
2nd Floor Finish Plan
|
11/13/2009
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Finish Plan
|
03/05/2010
|
Interior Architectural
|
IA5.01
|
1st Floor Wall Finish Plan
|
03/05/2010
|
Interior Architectural
|
IA5.02
|
2nd Floor Wall Finish Plan
|
03/05/2010
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Wall Finish Plan
|
03/05/2010
|
Interior Architectural
|
IA6.01
|
1st Floor Furniture Plan
|
10/23/2009
|
Interior Architectural
|
IA6.02
|
2nd Floor Furniture Plan
|
10/23/2009
|
Interior Xxxxxxxxxxxxx
|
XX0.00
|
0xx Xxxxx Furniture Plan
|
10/23/2009
|
Interior Architectural
|
IA7.01
|
Enlarged Floor Plan Conference Center
|
03/05/2010
|
Interior Architectural
|
IA7.02
|
Interior Elevation Conference Center
|
11/13/2009
|
Interior Architectural
|
IA7.03
|
Interior Elevation Conference Center
|
10/23/2009
|
Interior Architectural
|
IA7.04
|
Enlarged Floor Plan -Large Conference Center
|
03/05/2010
|
Interior Architectural
|
IA7.05
|
Interior Elevation Large Conference Center
|
10/23/2009
|
Interior Architectural
|
IA7.06
|
Enlarged Floor Plan Cafe
|
11/13/2009
|
Interior Architectural
|
IA7.07
|
Enlarged Floor Plan -Cafe Display Wall
|
03/05/2010
|
Interior Architectural
|
IA7.08
|
Enlarged Floor Plan Business Center
|
03/05/2010
|
Interior Architectural
|
IA7.09
|
Enlarged Floor Plan Lounge
|
03/05/2010
|
Interior Architectural
|
IA7.10
|
Enlarged Floor Plan Locker Room
|
11/13/2009
|
Interior Architectural
|
IA7.11
|
Enlarged Floor Plan Governor's Suite
|
11/13/2009
|
Interior Architectural
|
IA7.l2
|
Enlarged Floor Plan Governor's Conference Room
|
03/05/2010
|
Interior Architectural
|
IA7.13
|
Enlarged Floor Plan Typical SVP Suite
|
10/23/2009
|
Interior Architectural
|
IA7.14
|
Enlarged Floor Plan Copy Area
|
03/05/2010
|
Interior Architectural
|
IA.715
|
Interior Elevations
|
03/05/2010
|
Interior Architectural
|
IA7.16
|
Interior Elevations
|
03/05/2010
|
Interior Architectural
|
IA7.17
|
Interior Elevations
|
10/23/2009
|
Interior Architectural
|
IA8.01
|
Sections and Elevations
|
11/13/2009
|
Interior Architectural
|
IA8.02
|
Sections and Elevations
|
03/05/2010
|
Interior Architectural
|
IA8.03
|
Typical Millwork Sections
|
11/13/2009
|
Interior Architectural
|
IA8.04
|
Locker Room Details
|
11/13/2009
|
Interior Architectural
|
IA8.05
|
Enlarged Plan Details
|
10/23/2009
|
Interior Architectural
|
IA8.06
|
Modernfold Wall Details
|
10/23/2009
|
Interior Architectural
|
IA8.07
|
Millwork Sections
|
11/13/2009
|
Interior Architectural
|
IA9.01
|
Ceiling Details
|
03/05/2010
|
Interior Architectural
|
IA9.02
|
Ceiling Details
|
10/23/2009
|
Interior Architectural
|
S.100
|
Structural Notes
|
10/23/2009
|
Structural
|
S.101
|
Typical Details
|
10/23/2009
|
Structural
|
S.102
|
Typical Details
|
11/13/2009
|
Structural
|
S.200
|
Foundation/First Floor Plan
|
03/05/2010
|
Structural
|
S.201
|
Second Floor Framing Plan
|
10/23/2009
|
Structural
|
S.202
|
Third Floor Framing Plan
|
03/05/2010
|
Structural
|
S.203
|
Main Roof Framing Plan
|
03/05/2010
|
Structural
|
S.204
|
Penthouse Roof Framing Plan
|
10/23/2009
|
Structural
|
S.300
|
Column Schedule
|
11/13/2009
|
Structural
|
S.400
|
Dome Framing Plan and Sections
|
03/05/2010
|
Structural
|
S.401
|
Loading Dock Plan and Sections
|
11/13/2009
|
Structural
|
S.402
|
Stair Sections
|
10/23/2009
|
Structural
|
S.403
|
Generator Enclosure Plans and Details
|
03/05/2010
|
Structural
|
5.500
|
Foundation Sections
|
03/05/2010
|
Structural
|
S.501
|
Sections
|
10/23/2009
|
Structural
|
S.502
|
Sections
|
03/05/2010
|
Structural
|
S.503
|
Sections
|
03/05/2010
|
Structural
|
S.504
|
Sections
|
03/05/2010
|
Structural
|
Kl.00
|
Food Service Equipment Plan and Legend
|
10/23/2009
|
Kitchen
|
Kl.01
|
Food Service Special Conditions & Mech Rough-Ins
|
10/23/2009
|
Kitchen
|
Kl.02
|
Food Service Plumbing & Gas Rough-Ins & Legend
|
10/23/2009
|
Kitchen
|
Kl.03
|
Electric Rough-Ins & Legend
|
10/23/2009
|
Kitchen
|
K2.00
|
Food Service Fabrication & Installation Details
|
10/23/2009
|
Kitchen
|
K3.00
|
Food Service Hood & Fire System Details
|
10/23/2009
|
Kitchen
|
AVl.0l
|
Audio/Visual First Floor Plan
|
03/05/2010
|
Audio/Visual
|
AVl.02
|
Audio/Visual Second Floor Plan
|
03/05/2010
|
Audio/Visual
|
AVl.03
|
Audio/Visual Third Floor Plan
|
03/05/2010
|
Audio/Visual
|
AV2.01
|
Audio/Visual First Floor RCP
|
03/05/2010
|
Audio/Visual
|
AV2.02
|
Audio/Visual Second Floor RCP
|
03/05/2010
|
Audio/Visual
|
AV2.03
|
Audio/Visual Third Floor RCP
|
03/05/2010
|
Audio/Visual
|
M.001
|
Mechanical Drawing List
|
03/05/2010
|
Mechanical
|
M.002
|
Mechanical Symbols and Legend List
|
03/05/2010
|
Mechanical
|
M.003
|
Mechanical Scope of Work
|
03/05/2010
|
Mechanical
|
M.101
|
Mechanical Site Plan
|
03/05/2010
|
Mechanical
|
M.102
|
Mechanical Ground Source Heat Exchanger Plan
|
03/05/2010
|
Mechanical
|
M.301
|
Mechanical First Floor Ductwork Plan
|
03/05/2010
|
Mechanical
|
M.301P
|
Mechanical First Floor Piping Plan
|
03/05/2010
|
Mechanical
|
M.302
|
Mechanical Second Floor Ductwork Plan
|
03/05/2010
|
Mechanical
|
M.302P
|
Mechanical Second Floor Piping Plan
|
03/05/2010
|
Mechanical
|
M.303
|
Mechanical Third Floor Ductwork Plan
|
03/05/2010
|
Mechanical
|
M.303P
|
Mechanical Third Floor Piping Plan
|
03/05/2010
|
Mechanical
|
M.304
|
Mechanical Roof Ductwork Plan
|
03/05/2010
|
Mechanical
|
M.304P
|
Mechanical Roof Pipinl1; Plan
|
03/05/2010
|
Mechanical
|
M.401
|
Mechanical Part Plans Sheet I
|
03/05/2010
|
Mechanical
|
M.402
|
Mechanical Part Plans Sheet 2
|
03/05/2010
|
Mechanical
|
M.403
|
Mechanical Part Plans Sheet 3
|
03/05/2010
|
Mechanical
|
M.404
|
Mechanical Part Plans Sheet 4
|
03/05/2010
|
Mechanical
|
M.405
|
Mechanical Part Plans Sheet 5
|
03/05/2010
|
Mechanical
|
M.406
|
Mechanical Part Plans Sheet 6
|
03/05/2010
|
Mechanical
|
M.407
|
Mechanical Part Plans Sheet 7
|
03/05/2010
|
Mechanical
|
M.408
|
Mechanical Part Plans Sheet 8
|
03/05/2010
|
Mechanical
|
M.501
|
Mechanical Air Riser Diagram
|
03/05/2010
|
Mechanical
|
M.502
|
Mechanical Water Rise Dial1;ram
|
03/05/2010
|
Mechanical
|
M.503
|
Mechanical Closed Condenser Riser Dial1;ram
|
03/05/2010
|
Mechanical
|
M.504
|
Mechanical Glycol System Riser Diagram
|
03/05/2010
|
Mechanical
|
M.505
|
Mechanical Condenser Water Riser Diagram
|
03/05/2010
|
Mechanical
|
M.506
|
Mechanical Hot Water Riser Diagram
|
03/05/2010
|
Mechanical
|
M.507
|
Mechanical Chilled Water Riser Dial1;ram
|
03/05/2010
|
Mechanical
|
M.508
|
Mechanical Snowmelt Riser Diagram
|
03/05/2010
|
Mechanical
|
M.509
|
Mechanical Radiant Floor/Geothermal Flow Diagram
|
03/05/2010
|
Mechanical
|
M.601
|
Mechanical Schedules Sheet I
|
03/05/2010
|
Mechanical
|
M.602
|
Mechanical Schedules Sheet 2
|
03/05/2010
|
Mechanical
|
M.603
|
Mechanical Schedules Sheet 3
|
03/05/2010
|
Mechanical
|
M.604
|
Mechanical Schedules Sheet 4
|
03/05/2010
|
Mechanical
|
M.605
|
Mechanical Schedules Sheet 5
|
03/05/2010
|
Mechanical
|
M.606
|
Mechanical Schedules Sheet 6
|
03/05/2010
|
Mechanical
|
M.70l
|
Mechanical Details Sheet I
|
03/05/2010
|
Mechanical
|
M.702
|
Mechanical Details Sheet 2
|
03/05/2010
|
Mechanical
|
M.703
|
Mechanical Details Sheet 3
|
03/05/2010
|
Mechanical
|
M.704
|
Mechanical Details Sheet 4
|
03/05/2010
|
Mechanical
|
M.705
|
Mechanical Details Sheet 5
|
03/05/2010
|
Mechanical
|
M.706
|
Mechanical Details Sheet 6
|
03/05/2010
|
Mechanical
|
M.707
|
Mechanical Details Sheet 7
|
03/05/2010
|
Mechanical
|
M.801
|
Mechanical Controls Sheet I
|
03/05/2010
|
Mechanical
|
M.802
|
Mechanical Controls Sheet 2
|
03/05/2010
|
Mechanical
|
M.803
|
Mechanical Controls Sheet 3
|
03/05/2010
|
Mechanical
|
E.001
|
Electrical Drawinl1; List
|
03/05/2010
|
Electrical
|
E.100
|
Electrical Site Key Plan
|
03/05/2010
|
Electrical
|
E.101
|
Electrical Site Plan Sheet I
|
03/05/2010
|
Electrical
|
E.I02
|
Electrical Site Plan Sheet 2
|
03/05/2010
|
Electrical
|
E.103
|
Electrical Site Plan Sheet 3
|
03/05/2010
|
Electrical
|
E.I04
|
Electrical Site Plan Sheet 3
|
03/05/2010
|
Electrical
|
E.105
|
Electrical Site Plan Sheet 3
|
03/05/2010
|
Electrical
|
E.301
|
First Floor Underground Conduit Routing
|
03/05/2010
|
Electrical
|
E.301AV
|
First Floor AV Empty Conduit System Plan
|
03/05/2010
|
Electrical
|
E.301L
|
First Floor Lighting Plan
|
03/05/2010
|
Electrical
|
E.301P
|
First Floor Power Plan
|
03/05/2010
|
Electrical
|
E.302AV
|
Second Floor AV Empty Conduit System Plan
|
03/05/2010
|
Electrical
|
E.302L
|
Second Floor Lighting Plan
|
03/05/2010
|
Electrical
|
E.302P
|
Second Floor Power Plan
|
03/05/2010
|
Electrical
|
E.303AV
|
Third Floor AV Empty Conduit System Plan
|
03/05/2010
|
Electrical
|
E.303L
|
Third Floor Lighting Plan
|
03/05/2010
|
Electrical
|
E.303P
|
Third Floor Power Plan
|
03/05/2010
|
Electrical
|
E.304P
|
Roof Lighting and Power Plan
|
03/05/2010
|
Electrical
|
E.400
|
Electrical Part Plans
|
03/05/2010
|
Electrical
|
E.401
|
Kitchen & Cafe & Loading Dock Details
|
03/05/2010
|
Electrical
|
E402
|
Elec Data Center Details and Elevations
|
03/05/2010
|
Electrical
|
E.500
|
Electrical Power Riser Diagram
|
03/05/2010
|
Electrical
|
E.501
|
Fire Alarm Riser Diagram
|
03/05/2010
|
Electrical
|
E.601
|
Electrical Schedules Sheet I
|
03/05/2010
|
Electrical
|
E.602
|
Electrical Schedules Sheet 2
|
03/05/2010
|
Electrical
|
E.603
|
Electrical Schedules Sheet 3
|
03/05/2010
|
Electrical
|
E.604
|
Light Fixture Schedule
|
03/05/2010
|
Electrical
|
E.700
|
Lighting Protection Details
|
03/05/2010
|
Electrical
|
E.700A
|
Lightning Protection Details
|
03/05/2010
|
Electrical
|
E.701
|
Electrical Details Sheet I
|
03/05/2010
|
Electrical
|
E.702
|
Electrical Details Sheet 2
|
03/05/2010
|
Electrical
|
E.703
|
Electrical Details Sheet 3
|
03/05/2010
|
Electrical
|
E.704
|
Electrical Details Sheet 4
|
03/05/2010
|
Electrical
|
E.705
|
Electrical Details Sheet 5
|
05/05/2010
|
Electrical
|
P.300
|
Plumbing Drawing List, Svmbols, Legend & Schedule
|
03/05/2010
|
Plumbing
|
P.301
|
Plumbing; First Floor Plan
|
03/05/2010
|
Plumbing
|
P.302
|
Plumbing Second Floor Plan
|
03/05/2010
|
Plumbing
|
P.303
|
Plumbing Third Floor Plan
|
03/05/2010
|
Plumbing
|
P.304
|
Plumbing; Roof Plan
|
03/05/2010
|
Plumbing
|
P.400
|
Plumbing Enlarged Toilet Room Part Plans
|
03/05/2010
|
Plumbing
|
P.401
|
Plumbing Enlarged Kitchen. Equipment and Riser
|
03/05/2010
|
Plumbing
|
P.402
|
Plumbing; Part Plans
|
03/05/2010
|
Plumbing
|
P.403
|
Plumbing Part Plans and Storage Tank Details
|
03/05/2010
|
Plumbing
|
P.500
|
Plumbing Domestic Water Riser Diagram
|
03/05/2010
|
Plumbing
|
P.501
|
Plumbing Non Potable Water Riser Diagram
|
03/05/2010
|
Plumbing
|
P.502
|
Plumbing Storm Water Riser Diagram
|
03/05/2010
|
Plumbing
|
P.503
|
Plumbing Sanitary Riser Diagram
|
03/05/2010
|
Plumbing
|
P.504
|
Plumbing Sanitary Riser & Water Diagram
|
03/05/2010
|
Plumbing
|
P.505
|
Plumbing Gas Riser Diagram
|
03/05/2010
|
Plumbing
|
P.600
|
Plumbing Details
|
03/05/2010
|
Plumbing
|
FP.300
|
Symbols. Drawing; List Fire Protection
|
03/05/2010
|
Fire Protection
|
FP.301
|
First Floor Fire Protection Plan
|
03/05/2010
|
Fire Protection
|
FP.302
|
Second Floor Fire Protection Plan
|
03/05/2010
|
Fire Protection
|
FP.303
|
Third Floor Fire Protection Plan
|
03/05/2010
|
Fire Protection
|
FP.304
|
Roof Fire Protection Plan
|
03/05/2010
|
Fire Protection
|
FP.500
|
Fire Protection Riser Diagram
|
03/05/2010
|
Fire Protection
|
FP.700
|
Fire Protection Details
|
03/05/2010
|
Fire Protection
|
T.001
|
Telecom Drawing List, Symbols, and Abbreviations
|
03/05/2010
|
Tele/Data
|
T.101
|
Telecom Site Plan Sheet 1
|
03/05/2010
|
Tele/Data
|
T.301
|
First Floor Telecom Plan
|
03/05/2010
|
Tele/Data
|
T.30lU
|
First Floor Underground Telecom Plan
|
10/23/2010
|
Tele/Data
|
T.302
|
Second Floor Telecom Plan
|
03/05/2010
|
Tele/Data
|
T.303
|
Third Floor Telecom Plan
|
03/05/2010
|
Tele/Data
|
T.304
|
Roof Telecom Plan
|
03/05/2010
|
Tele/Data
|
T.400
|
Tele Data Center Details and Elevation
|
03/05/2010
|
Tele/Data
|
T.401
|
Tele Room Details and Elevations Sheet I
|
03/05/2010
|
Tele/Data
|
T.402
|
Tele Room Details and Elevations Sheet II
|
03/05/2010
|
Tele/Data
|
T.403
|
Tele Room Details and Elevations Sheet ill
|
03/05/2010
|
Tele/Data
|
T.501
|
Tele Pathways Riser Diagram
|
03!tl5/2010
|
Tele/Data
|
T.502
|
Tele Copper Riser Diagram
|
03/05/2010
|
Tele/Data
|
T.503
|
Tele Fiber Riser Diagram
|
03/05/2010
|
Tele/Data
|
T.504
|
Tele Grounding and Bonding Riser Diagram
|
03/05/2010
|
Tele/Data
|
T.600
|
Tele Details
|
03/05/2010
|
Tele/Data
|
SC-0l
|
Security Floor Plan 01
|
03/05/2010
|
Security
|
SC-02
|
Security Floor Plan 02
|
03/05/2010
|
Security
|
SC·03
|
Security Floor Plan 03
|
03/05/2010
|
Security
|
SC-04
|
Security Conduit Roof Plan
|
03/05/2010
|
Security
|
SC-05
|
Security Conduit Upper Roof Plan
|
03/05/2010
|
Security
|
SC-020
|
Security Conduit Legend
|
03/05/2010
|
Security
|
SC-600-A
|
Security Conduit Details
|
03/05/2010
|
Security
|
SC-600-B
|
Security Conduit Details
|
03/05/2010
|
Security
|
SD-01
|
Security Device Floor Plan 01
|
03/05/2010
|
Security
|
SD-02
|
Security Device Floor Plan 02
|
03/05/2010
|
Security
|
SD-03
|
Security Device Floor Plan 03
|
03/05/2010
|
Security
|
SD-04
|
Security Device Roof Plan
|
03/05/2010
|
Security
|
SD-05
|
Security Device Upper Roof Plan
|
03/05/2010
|
Security
|
SD-010
|
Security Device Legend
|
03/05/2010
|
Security
|
SD-300-A
|
Security Device Riser Diagram
|
03/05/2010
|
Security
|
SD-300-B
|
Fiber Optic Riser Diagram
|
03/05/2010
|
Security
|
SD-300-C
|
Security System Functional Diagram
|
03/05/2010
|
Security
|
SD-300-D
|
Security Device Details
|
03/05/2010
|
Security
|
SD-300-E
|
Security Device Details
|
03/05/2010
|
Security
|
SD-300-F
|
Security Device Details
|
03/05/2010
|
Security
|
SITE-SC-A
|
Security Conduit Plan A
|
03/05/2010
|
Security
|
SITE-SC-B
|
Site Security Conduit Plan B
|
03/05/2010
|
Security
|
SITE-SD-A
|
Site Security Device Plan A
|
03/05/2010
|
Security
|
SITE-SD-B | Site Security Device Plan B | 03/05/2010 | Security |
Contract Specification List:
Specifications issued by Xxxxxxxxx Xxxxxx and Xxxxxx PC (KGD) Architecture.
Prepared by KGD, Fox, Xxxxx+Xxxxx, SK&A, and Others
Section
|
Title
|
Date
|
Division
|
00320
|
Geotechnical Report
|
10/23/2009
|
Bidding & Contract
|
01100
|
Summary of Work
|
10/23/2009
|
General Requirements
|
01120
|
Indoor Air Quality Requirements
|
10/23/2009
|
General Requirements
|
01150
|
Sustainable Design Requirements
|
10/23/2009
|
General Requirements
|
01190
|
Definitions and Explanations
|
10/23/2009
|
General Requirements
|
01210
|
Allowances
|
10/23/2009
|
General Requirements
|
01230
|
Alternates
|
03/05/2010
|
General Requirements
|
01250
|
Contract Modifications
|
10/23/2009
|
General Requirements
|
01270
|
Unit Prices
|
10/23/2009
|
General Requirements
|
01290
|
Applications for Payment
|
10/23/2009
|
General Requirements
|
01310
|
Project Meetings
|
03/05/2010
|
General Requirements
|
01320
|
Construction Photographs
|
10/23/2009
|
General Requirements
|
01325
|
Project Schedules
|
10/23/2009
|
General Requirements
|
01330
|
Submittal Procedures
|
03/05/2010
|
General Requirements
|
01349
|
Coordination Drawings
|
10/23/2009
|
General Requirement
|
01420
|
Cades and Reference Standards
|
10/23/2009
|
General Requirements
|
01450
|
Testing and Inspection Services
|
10/23/2009
|
General Requirements
|
01510
|
Temporary Utilities
|
10/23/2009
|
General Requirements
|
01520
|
Construction Facilities
|
03/05/2010
|
General Requirements
|
01550
|
Vehicular Access and Parking
|
10/23/2009
|
General Requirements
|
01560
|
Temporary Barriers and Enclosures
|
10/23/2009
|
General Requirements
|
01570
|
Temporary Controls
|
10/23/2009
|
General Requirements
|
01572
|
Construction Waste Management and Disposal
|
10/23/2009
|
General Requirements
|
01630
|
Product Substitution Procedures
|
10/23/2009
|
General Requirements
|
01650
|
Product Delivery. Storage and Handling
|
10/23/2009
|
General Requirements
|
01720
|
Field Engineering
|
10/23/2009
|
General Requirements
|
01730
|
Product Installation and Protection
|
10/23/2009
|
General Requirements
|
01740
|
Final C1eaning
|
03/05/2010
|
General Requirements
|
01770
|
Closeout Procedures
|
03/05/2010
|
General Requirements
|
01780
|
Project Record Documents
|
10/23/2009
|
General Requirements
|
01782
|
Operation and Maintenance Data
|
03/05/2010
|
General Requirements
|
01820
|
Demonstration and Training.
|
03/05/2010
|
General Requirements
|
02010
|
General Site Work Conditions
|
10/23/2009
|
Site Concrete
|
02215
|
Subgrade Preparation
|
10/23/2009
|
Site Concrete
|
02230
|
Site Clearing
|
10/23/2009
|
Site Concrete
|
02231
|
Tree Protection
|
10/23/2009
|
Site Concrete
|
02236
|
Aggregate Base Course
|
10/23/2009
|
Site Concrete
|
02239
|
Erosion and Sediment Control
|
10/23/2009
|
Site Concrete
|
02240
|
Dewatering
|
10/23/2009
|
Site Concrete
|
02300
|
Earthwork
|
10/23/2009
|
Site Concrete
|
02340
|
Structural Soil
|
11/13/2009
|
Site Concrete
|
02360
|
Termite Control
|
10/23/2009
|
Site Concrete
|
02512
|
Decomposed Granite Paving
|
11/13/2009
|
Site Concrete
|
02514
|
Portland Cement Concrete Site Work
|
10/23/2009
|
Site Concrete
|
02521
|
Concrete Curbs and Sidewalks
|
10/23/2009
|
Site Concrete
|
02555
|
Asphalt Concrete Pavement
|
10/23/2009
|
Site Concrete
|
02700
|
Storm Sewer
|
10/23/2009
|
Site Concrete
|
02721
|
Catch Basins and Inlets
|
10/23/2009
|
Site Concrete
|
02726
|
Precast Concrete Manhole
|
10/23/2009
|
Site Concrete
|
02730
|
Sanitary Sewer
|
10/23/2009
|
Site Concrete
|
02750
|
Water Distribution Systems
|
10/23/2009
|
Site Concrete
|
02780
|
Unit Pavers
|
03/05/2010
|
Site Concrete
|
02795
|
Grass Paving System
|
10/23/2010
|
Site Concrete
|
02810
|
Irrigation Systems
|
11/13/2009
|
Site Concrete
|
02870
|
Site and Street Furnishings
|
11/13/2009 '
|
Site Concrete
|
02920
|
Lawns and Grasses
|
11/13/2009
|
Site Concrete
|
02930
|
Exterior Plants
|
10/23/2009
|
Site Concrete
|
00000
|
Xxxx-Xx-Xxxxx Concrete
|
10/23/2009
|
Concrete
|
04060
|
Unit Masonry Mortar and Grout
|
10/23/2009
|
Masonry
|
04065
|
Stone Mortar and Grout
|
10/23/2009
|
Masonry
|
04210
|
Unit Masonry
|
10/23/2009
|
Masonry
|
04400
|
Stonework
|
10/23/2009
|
Masonry
|
04405
|
Exterior Stone Cladding
|
10/23/2009
|
Masonry
|
04720
|
Cast Stone
|
10/23/2009
|
Xxxxxxx
|
00000
|
Xxxxxxxxxxxxx Finish
|
03/05/2010
|
Metals
|
05120
|
Structural Steel
|
10/23/2009
|
Metals
|
05310
|
Steel Deck
|
10/23/2009
|
Metals
|
05400
|
Cold-Formed Metal Framing
|
10/23/2009
|
Metals
|
05500
|
Metal Fabrications
|
10/23/2009
|
Metals
|
05700
|
Ornamental Metal
|
10/23/2009
|
Metals
|
06070
|
Wood Treatment
|
10/23/2009
|
Wood & Plastic
|
06100
|
Rough Carpentry
|
03/05/2010
|
Wood & Plastic
|
06160
|
Sheathing
|
10/23/2009
|
Wood & Plastic
|
06400
|
Architectural Woodwork
|
10/23/2009
|
Wood. & Plastic
|
07110
|
Bituminous Damnproofing
|
10/23/2009
|
Thermal Protection
|
07130
|
Sheet Membrane Waterproofing
|
10/23/2009
|
Thermal Protection
|
07166
|
Crvstalline Waterproofing
|
10/23/2009
|
Thermal Protection
|
07170
|
Bentonite Waterproofing
|
10/23/2009
|
Thermal Protection
|
07210
|
Building Insulation
|
10/23/2009
|
Thermal Protection
|
07270
|
Air Barrier Systems
|
10/23/2009
|
Thermal Protection
|
07410
|
Metal Roof Panels
|
10/23/2009
|
Thermal Protection
|
07430
|
Aluminum Composite Panel System
|
10/23/2009
|
Thermal Protection
|
07540
|
Membrane Roofing
|
03/05/2010
|
Thermal Protection
|
07620
|
Sheet Metal Flashing and Trim
|
10/23/2009
|
Thermal Protection
|
07810
|
Applied Fireproofing
|
10/23/2009
|
Thermal Protection
|
07840
|
Firestopping
|
10/23/2009
|
Thermal Protection
|
07900
|
Joint Sealants
|
10/23/2009
|
Thermal Protection
|
08110
|
Steel Doors and Frames
|
03/05/2010
|
Openings
|
08120
|
Aluminum Frames
|
10/23/2009
|
Openings
|
08210
|
Flush Wood Doors
|
10/23/2009
|
Openings
|
08310
|
Access Doors and Panels
|
10/23/2009
|
Openings
|
08330
|
Coiling Doors
|
10/23/2009
|
Openings
|
08400
|
Exterior Wall Performance Requirements
|
10/23/2009
|
Openings
|
08405
|
Window Wall Mock-UD and Testing
|
03/05/2010
|
Openings
|
08410
|
Aluminum Entrances and Window Wall
|
10/23/2009
|
Openings
|
08520
|
Aluminum Windows
|
10/23/2009
|
Openings
|
08630
|
Skylights
|
10/23/2009
|
Openings
|
08710
|
Door Hardware
|
03/05/2010
|
Openings
|
08800
|
Glass and Glazing
|
03/05/2010
|
Openings
|
09100
|
Metal Support Assemblies
|
10/23/2009
|
Finishes
|
09230
|
Plaster Fabrications (GRG)
|
10/23/2009
|
Finishes
|
09250
|
Gypsum Board
|
10/23/2009
|
Finishes
|
09310
|
Tile
|
03/05/2010
|
Finishes
|
09510
|
Acoustical Ceilings
|
11/13/2009
|
Finishes
|
09570
|
Linear Wood Ceilings
|
10/23/2009
|
Finishes
|
09640
|
Wood Strip Flooring
|
03/05/2010
|
Finishes
|
09650
|
Resilient Flooring
|
10/23/2009
|
Finishes
|
09680
|
Carpet
|
03/05/2010
|
Finishes
|
09720
|
Wall Coverings
|
10/23/2009
|
Finishes
|
09810
|
Acoustical Panels
|
11/13/2009
|
Finishes
|
09900
|
Painting and Finishing
|
10/23/2009
|
Finishes
|
10200
|
Louvers and Vents
|
10/23/2009
|
Specialties
|
10260
|
Wall and Corner Guards
|
03/05/2010
|
Specialties
|
10270
|
Access Flooring
|
10/23/2009
|
Specialties
|
10305
|
Manufactured Fireplaces
|
10/23/2009
|
Specialties
|
10350
|
Flagpoles
|
11/13/2009
|
Specialties
|
10510
|
Plastic Laminate Lockers
|
10/23/2009
|
Specialties
|
10520
|
Fire Protection Specialties
|
10/23/2009
|
Specialties
|
10605
|
Wire Mesh Partitions
|
03/05/2010
|
Specialties
|
10650
|
Folding Panel Partitions
|
10/23/2009
|
Specialties
|
10670
|
Mobile Storage System
|
03/05/2010
|
Specialties
|
10800
|
Toilet Accessories
|
10/23/2009
|
Specialties
|
11130
|
Projection Screens
|
10/23/2009
|
Equipment
|
11160
|
Loading Dock Equipment
|
10/23/2009
|
Equipment
|
11400
|
Food Service Equipment
|
10/23/2009
|
Equipment
|
00000
|
Xxxxxxxxxxx Appliances
|
10/23/2009
|
Equipment
|
12492
|
Shades
|
10/23/2009
|
Furnishings
|
13700
|
Security Management System
|
11/13/2009
|
Special Construction
|
13750
|
Automatic Door/Security System Interface
|
11/13/2009
|
Special Construction
|
13760
|
Access Control Hardware
|
11/13/2009
|
Special Construction
|
13770
|
Electrical Equipment Interfaces to Electronic Security Systems
|
11/13/2009
|
Special Construction
|
13780
|
Elevator/Security System Interface
|
11/13/2009
|
Special Construction
|
13790
|
Fire Alarm/Security System Interface
|
11/13/2009
|
Special Construction
|
13800
|
Overhead Door/Security System Interface
|
11/13/2009
|
Special Construction
|
13810
|
Vehicle Gate/Security System Interface
|
11/13/2009
|
Special Construction
|
14215
|
Elevator Traction Elevators
|
10/23/2009
|
Conveying Equipment
|
15301
|
Fire Protection Special Conditions
|
10/23/2009
|
Mechanical
|
15302
|
Scope of Work
|
10/23/2009
|
Mechanical
|
15304
|
Access Doors in General Construction
|
10/23/2009
|
Mechanical
|
15306
|
Fire Protection Firestopping
|
10/23/2009
|
Mechanical
|
15308
|
Fire Protection Basic Materials and Methods
|
10/23/2009
|
Mechanical
|
15310
|
Piping and Fitting Materials
|
10/23/2009
|
Mechanical
|
15311
|
Hangers. Supports. Anchors. and Guides
|
10/23/2009
|
Mechanical
|
00000
|
Xxxxxx
|
10/23/2009
|
Mechanical
|
15316
|
Wet Pipe Sprinkler Systems
|
10/23/2009
|
Mechanical
|
15317
|
Dry Pipe Sprinkler Systems
|
10/23/2009
|
Mechanical
|
15318
|
Pre-Action Sprinkler Systems
|
03/05/2010
|
Mechanical
|
00000
|
XX-000 Xxxxxxxxxxxxx System
|
10/23/2009
|
Mechanical
|
15320
|
Standpipe and Hose Systems
|
10/23/2009
|
Mechanical
|
15340
|
Pumps
|
10/23/2009
|
Mechanical
|
15395
|
Commissioning of Fire Protection Systems
|
10/23/2009
|
Mechanical
|
15401
|
Plumbing Special Conditions
|
10/23/2009
|
Mechanical
|
15402
|
Scope of Work
|
10/23/2009
|
Mechanical
|
15404
|
Access Doors in General Construction
|
10/23/2009
|
Mechanical
|
15405
|
Plumbing Firestopping
|
10/23/2009
|
Mechanical
|
15406
|
Testing
|
10/23/2009
|
Mechanical
|
15407
|
Identification for Plumbing Piping Equipment
|
10/23/2009
|
Mechanical
|
15408
|
Plumbing Basic Materials and Methods
|
10/23/2009
|
Mechanical
|
15409
|
Heat Tracing for Plumbing Pipe
|
10/23/2009
|
Mechanical
|
15410
|
Piping and Filling Materials
|
10/23/2009
|
Mechanical
|
15411
|
Hangers, Supports, Anchors, and Guides
|
10/23/2009
|
Mechanical
|
00000
|
Xxxxxx
|
10/23/2009
|
Mechanical
|
15413
|
Disinfecting of Water Supply System
|
10/23/2009
|
Mechanical
|
15414
|
Backflow Prevention
|
10/23/2009
|
Mechanical
|
15415
|
Plumbing Fixtures and Trim
|
03/05/2010
|
Mechanical
|
15416
|
Domestic Water Heaters
|
10/23/2009
|
Mechanical
|
15417
|
Domestic Water System
|
10/23/2009
|
Mechanical
|
15419
|
Sanitary and Storm Drainage Systems
|
10/23/2009
|
Mechanical
|
15420
|
Siphonic Roof Drainage
|
10/23/2009
|
Mechanical
|
15424
|
Water Meters
|
10/23/2009
|
Mechanical
|
15425
|
Vibration Isolation
|
10/23/2009
|
Mechanical
|
15428
|
Insulation
|
10/23/2009
|
Mechanical
|
15429
|
Natural Gas System
|
10/23/2009
|
Mechanical
|
15440
|
Pumps
|
03/05/2010
|
Mechanical
|
15450
|
Potable-Water Storage Tanks
|
10/23/2009
|
Mechanical
|
15495
|
Commissioning of Plumbing Systems
|
10/23/2009
|
Mechanical
|
15500
|
Separation of Work Between Trades
|
10/23/2009
|
Mechanical
|
15501
|
HVAC Special Conditions ,
|
10/23/2009
|
Mechanical
|
15504
|
Access Doors in General Construction
|
10/23/2009
|
Mechanical
|
15505
|
System Identification
|
10/23/2009
|
Mechanical
|
15506
|
Firestopping
|
10/23/2009
|
Mechanical
|
15507
|
Instruments
|
03/05/2010
|
Mechanical
|
15509
|
Piping and Accessories
|
10/23/2009
|
Mechanical
|
15512
|
Hangers, Anchors, and Supports
|
10/23/2009
|
Mechanical
|
00000
|
Xxxxxx
|
03/05/2010
|
Mechanical
|
15514
|
Expansion Compensators
|
10/23/2009
|
Mechanical
|
15515
|
Pipe Cleaning and Chemical Water Treatment
|
03/05/2010
|
Mechanical
|
15516
|
Testing, Adjusting. and Balancing
|
10/23/2009
|
Mechanical
|
15526
|
Water Specialties
|
10/23/2009
|
Mechanical
|
15530
|
Sheetmetal
|
03/05/2010
|
Mechanical
|
15531
|
Dampers
|
10/23/2009
|
Mechanical
|
15533
|
Vents. Stacks. and Breeching
|
10/23/2009
|
Mechanical
|
15540
|
Pumps
|
03/05/2010
|
Mechanical
|
15550
|
Hydronic Radiant Floor Heating and Cooling System
|
10/23/2009
|
Mechanical
|
15551
|
Snow and Ice Melting Specifications
|
10/23/2009
|
Mechanical
|
15554
|
Packaged Fire Tube Boilers
|
10/23/2009
|
Mechanical
|
15680
|
Refrigeration Machines (Water Cooled)
|
03/05/2010
|
Mechanical
|
15710
|
Cooling Towers
|
10/23/2009
|
Mechanical
|
15711
|
Water Filters and Cleaners
|
10/23/2009
|
Mechanical
|
15755
|
Heat Exchanger
|
10/23/2009
|
Mechanical
|
15760
|
Thermal Energy Storage
|
10/23/2009
|
Mechanical
|
15766
|
Closed Loop Geothermal System
|
10/23/2009
|
Mechanical
|
15770
|
Heat Pumps
|
03/05/2010
|
Mechanical
|
15783
|
Computer Room Air Conditioning Units
|
10/23/2009
|
Mechanical
|
15790
|
Coils
|
10/23/2009
|
Mechanical
|
15830
|
Space Heating Units
|
10/23/2009
|
Mechanical
|
15831
|
Fan Coil Units
|
03/05/2010
|
Mechanical
|
15855
|
Factory Assembled Air-Handling Units
|
03/05/2010
|
Mechanical
|
15860
|
Fans
|
10/23/2009
|
Mechanical
|
15885
|
Air Filters and Cleaners
|
10/23/2009
|
Mechanical
|
15920
|
Acoustics
|
03/05/2010
|
Mechanical
|
15925
|
Vibration Isolation
|
10/23/2009
|
Mechanical
|
15928
|
Insulation
|
03/05/2010
|
Mechanical
|
15930
|
Air Terminal Units
|
11/13/2009
|
Mechanical
|
15940
|
Air Outlets and Inlets
|
10/23/2009
|
Mechanical
|
15945
|
Electric Motors
|
10/23/2009
|
Mechanical
|
15946
|
Electric Motor Controllers
|
10/23/2009
|
Mechanical
|
15947
|
Variable Frequency Controllers
|
10/23/2009
|
Mechanical
|
15950
|
Electric Heat Tracing
|
03/05/2010
|
Mechanical
|
15975
|
Building Management and Control System (BMCS)
|
03/05/2010
|
Mechanical
|
15995
|
Commissioning of HVAC Systems
|
03/05/2010
|
Mechanical
|
16000
|
Separation of Work Between Trades
|
10/23/2009
|
Electrical
|
16001
|
Electrical Special Conditions
|
10/23/2009
|
Electrical
|
16002
|
Scope of Work
|
03/05/2010
|
Electrical
|
16005
|
Systems Identification
|
10/23/2009
|
Electrical
|
16006
|
Testing, Adjusting and Balancing
|
10/23/2009
|
Electrical
|
16007
|
Temporary Lighting and Power
|
10/23/2009
|
Electrical
|
16010
|
Equipment Connections and Coordination
|
10/23/2009
|
Electrical
|
16030
|
Vibration Isolation and Seismic Restraint~
|
10/23/2009
|
Electrical
|
16050
|
Electrical Materials and Methods
|
11/13/2009
|
Electrical
|
16110
|
Raceways and Boxes
|
11/13/2009
|
Electrical
|
16120
|
600 Volt Wire and Cable
|
10/23/2009
|
Electrical
|
16130
|
Wiring Devices
|
10/23/2009
|
Electrical
|
16140
|
Installation of Individual Motor Controllers
|
10/23/2009
|
Electrical
|
16150
|
Disconnect Switches
|
10/23/2009
|
Electrical
|
16160
|
Fuses (600 V and Less)
|
10/23/2009
|
Electrical
|
16170
|
Panelboards
|
10/23/2009
|
Electrical
|
16190
|
Ceiling, Floor and Wall Electrical Penetration Fire Seals
|
10/23/2009
|
Electrical
|
16211
|
Electric Sub-Metering System
|
03/05/2010
|
Electrical
|
16225
|
Bifuel Emergency Generator(s) and Accessories
|
03/05/2010
|
Electrical
|
16231
|
Micro Turbine Generator
|
10/23/2009
|
Electrical
|
16289
|
Transient Voltage Suppression
|
10/23/2009
|
Electrical
|
16415
|
Transfer Switches
|
03/05/2010
|
Electrical
|
16420
|
Switchboards
|
10/23/2009
|
Electrical
|
16430
|
Dry Type Transformers
|
10/23/2009
|
Electrical
|
16450
|
Grounding System
|
10/23/2009
|
Electrical
|
16460
|
Lightning Protection
|
03/05/2010
|
Electrical
|
16470
|
Motor Control Centers
|
10/23/2009
|
Electrical
|
16500
|
Luminaires & Accessories
|
10/23/2009
|
Electrical
|
16520
|
Modular Wiring System
|
10/23/2009
|
Electrical
|
16530
|
Individual Dimmer Switches
|
10/23/2009
|
Electrical
|
16561
|
Occupancy Sensor Lighting Control
|
10/23/2009
|
Electrical
|
16570
|
Conference Center Dimming System
|
10/23/2009
|
Electrical
|
16580
|
Electronic Dimming Bollards
|
10/23/2009
|
Electrical
|
16631
|
Uninterruptible Power System (Workstation)
|
03/05/2010
|
Electrical
|
16632
|
Uninterruptible Power System (Data Center)
|
03/05/2010
|
Electrical
|
16721
|
Fire Alarm and Detection Supply
|
03/05/2010
|
Electrical
|
16750
|
Telecommunications Cabling System
|
03/05/2010
|
Electrical
|
16751
|
Telecommunications Pathways and Spaces
|
03/05/2010
|
Electrical
|
16790
|
Lighting Control System
|
03/05/2010
|
Electrical
|
16900
|
Photovoltaic System
|
03/05/2010
|
Electrical
|
16995
|
Commissioning of Electrical Systems
|
03/05/2010
|
Electrical
|
End Specification List
EXHIBIT B
ASSUMPTIONS & CLARIFICANONS TO AMENDMENT No.1
May 17, 2010
General Clarifications:
1. The overall Schedule of Values total represents the GMP; each individual line item within the GMP is not guaranteed.
2.
|
The Payment & Performance Bond on Xxxxxxx-Xxxxxx has been waived. Trade Contractors will be bonded only on a case-by-case basis, following mutual discussions between the Xxxxxxx-Xxxxxx and the Owner. Generally. Trade Contractors with contracts under $500,000 will not be bonded.
|
3. The following costs are not included in Amendment NO.1 and are assumed to be provided by or, paid by. the Owner.
a.
|
Building Permits & Site Development Permits (including Grading Permits, Retaining Wall Permits, LCSA
|
Permits" and Sign Permits). Trade Permits are included in Amendment No. I
|
|
b.
|
Permit Expediting Services for Owner-supplied Permits.
|
c.
|
Site Bonds and Deposits. Proffer conditions not shown on design drawings.
|
d.
|
Public Space Permits or Easement costs for use of Public Right-of-Ways or neighboring properties for tie
|
ins, lay-down, staging, or pedestrian safety.
|
|
e.
|
Identification and monitoring of (1HP, Asbestos or other) contaminated soils and groundwater by an
|
Independent Environmental Testing Firm.
|
|
f.
|
Relocation of existing utilities by the Utility Companies including power, telephone/data, fiber optics, gas,
|
water and cable TV other than Owner Allowances indicated.
|
|
g.
|
Water & Sewer connection, use & service fees (permanent).
|
h.
|
Power & Telephone connection, use & service fees (permanent).
|
i.
|
Builders Risk Insurance.
|
j.
|
Builders Risk Deductibles.
|
k.
|
Permanent Power Primary Ductbank & Feeders.
|
l.
|
Permanent Power Secondary Feeders.
|
4.
|
The following engineering, subcontractor or material vendor packages are not included in Amendment No.1 and are assumed to be contracted for or procured directly by the Owner:
|
a.
|
Independent Testing & Inspection Firm.
|
b. |
Geotechnical Testing & Engineering Firm.
|
c.
|
Archeologist.
|
d.
|
Arborist.
|
e.
|
Geotechnical Investigation, Soil Borings or Rock Cores to evaluate competency of Rock.
|
f. |
Utility Consultant to interface with Public Utility Companies and Service Providers.
|
g.
|
LEED Third Party Reviewer including LEED Certification and submission costs.
|
h. |
Commissioning Agent.
|
i.
|
Waterproofing and Curtainwall Consultant.
|
j. |
Audio-Visual Equipment and Cabling.
|
k.
|
Security System Equipment and Cabling.
|
l.
|
Tele/Data/Cable TV Cabling & Equipment.
|
m.
|
Site Signage, Building Signage (Including Code Compliant Signage) and Graphics.
|
n.
|
FF& E. |
5.
|
As-built drawings win be provided as 'red-lined' drawings, not CAD drawings or CAD modifications of the Contract Drawings. Xxxxxxx-Xxxxxx will provide CAD files of the MEP coordination drawings.
|
6.
|
Current CAD drawings will be provided in electronic form to the Construction Manager by the design team at no cost for use in coordination and development of shop drawings. All CAD file recipients will sign KOD CAD Liability Waiver Agreement prior to issuance of CAD Files.
|
7.
|
Phase I photographs will serve as preconstruction photographs for the Phase II work.
|
8.
|
Slab edge drawings have been provided by the Design Team "For Information Only". Slab edge shop drawings by Xxxxxxx-Xxxxxx are not included.
|
9.
|
Preliminary layout will be completed for construction purposes. Partition layout will be provided. Field painting of the balance of the items as noted in 01720-3.I-D is not included. Design team will be made aware of all layout scheduling and may review if desired.
|
10.
|
Submittal review meetings with the design team may be required to expedite certain critical submittals due to the delayed release of these trade packages following design revisions. These review meetings. if required, will be provided at no cost to the Construction Manager.
|
11.
|
Submittal packages for building systems may be submitted as multiple, phased submittals. Submittal packages will be submitted on an individual trade basis; composite submittals involving multiple trades will not be provided.
|
12.
|
Xxxxxxx-Xxxxxx will make every effort to adequately interpret or clarify the Contract Documents prior to issuing a RFI. However, Xxxxxxx-Xxxxx shall not be responsible to Owner for costs charges by the Architect for the additional Architect services required to provide such information, even if such information is stated to be available in the Contract Documents.
|
13.
|
RFI, Submittal and Change Order Logs will be submitted with bi-weekly Owner-Architect-Contractor meeting minutes. Current logs can be requested at any time.
|
14.
|
Preinstallation Conferences will be held for all major construction activities that require coordination with other trades. Trades requiring preinstallation conferences will be agreed upon by project team.
|
15.
|
Elevator system will not be provided with battery backup. Backup power will be provided by the backup generators.
|
16.
|
Elevator procurement is based on the following payment schedule from the Elevator vendor (10% Retention will be withheld per Contract):
|
• Submission of Shop Drawings | 10% of Contract Value | |
• Release of Materials | 20% of Contract Value | |
• Material Ship to Jobsite | 50% of Contract Value | |
• Installation & Turnover | 20% of Contract Value |
17.
|
Several of the specified Material Suppliers require an early deposit on materials. Xxxxxxx-Xxxxxx will be allowed to invoice for required early deposits on materials. Proper documentation will be provided with invoices.
|
18.
|
Testing and inspection of concrete, reinforcing steel, masonry mortar, structural steel, fireproofing, waterproofing and roofing is by the Owner's Independent Testing & Inspection Firm.
|
19.
|
Temporary site perimeter fencing is not provided. Construction gates will be provided at road entrance.
|
20.
|
Tree protection and tree care measures for existing trees will be provided until substantial completion. After substantial completion, owner will assume tree care measures for existing trees.
|
21.
|
Batt insulation is fiberglass 3-1/2" batt insulation in lieu of 3-1/2" Ultratouch Insulation per approved Value Engineering for interior walls.
|
22.
|
For Sheet Membrane, manufacturers offer a 5-year material warranty only. Manufacturers do not offer material and labor warranties on sheet membranes. Waterproofing Contractor will provide a 5-year Watertight Warranty for Sheet Membrane Waterproofing.
|
23.
|
Specification 07540-1.3-0-1 requires the roofing contractor to show proof of deposit for warranty. This is not a
|
|
|
|
requirement of the manufacturer and is excluded.
|
24.
|
There is no finish warranty for the ATAS Ecoscreen panels at the Generator enclosure. This is excluded.
|
25.
|
At the loading dock canopy, a tapered Samafil Poly-iso insulation system with a minimum 1/2" thickness is provided. As this canopy is over unconditioned space, R-Values are not relevant.
|
26.
|
Snow guards detail at Samafil dome roof as shown will not be provided. Individual snow guards at gutter will be provided in lieu of continuous radiused snow guard.
|
27.
|
Curved Stud infill of the dome has been removed from the project. The true "dome" shape will be achieved with shimmed/sloped insulation.
|
Glazing System Clarifications:
28.
|
The exterior glazing aluminum framing system is based on a system manufactured by Accura Systems, Inc. This is system can be reglazed from the exterior in a repair situation by the way of an adaptor. The system is not a pressure glazed system at the punched openings. The system will be unitized with the exception of the stairwells. The curtainwalls at stairs A and B will be pressure glazed. (Re: 0841 0-5-2.I-A.2). The system will have dimensions of 2 1/2" x 6" at typical punched opening locations and 2 1/2" x 7 1/2 at the stairwells as shown on the documents.
|
29.
|
The ACCQ-WALL system by Accura at the stairwell is a classic "pressure equalized" system with the primary seal to the inside face of glass. The ACCUNIT system by Accura at all other locations is not classified as a "classic" pressure equalized system since the primary line of seal is the exterior face of glass. Both of the systems incorporate basic "rain screen" principles, but the primary vapor/air seal is not the interior face of system. Both of the proposed systems have been tested in accordance with AAMA guidelines by independent laboratories and will meet or exceed the air and water performance specified. The systems will offer the 5 year warranty specified. (Re: 08400-7-1.6-G)
|
30.
|
The exterior glazing aluminum framing system is designed to accommodate +/-3/8" live load deflection in either direction for a total deflection of 3/4" as specified (Re: 08400-5-1.6-C.7b and 08410-5-1.6-C.I). The system requires a 3/4" caulk joint. If a 3/4" deflection in either direction is required for both floors, the framing system would require modification and a 1-1/2" caulk joint at the head, the cost for which is not included in Amendment No.1.
|
31.
|
The glazing aluminum framing system specifications contain conflicting information on warranties. Specification Section 08400: 1.13.B & 08520: 1.13.A.1(a) calls for a 5 yr. performance warranty and Section 08410: 1.4.A.1(a) indicates a 10 yr. performance warranty (note: 08410: l.4.B also calls for a 5 yr. performance warranty). Specification Section 05080: 1.5.A calls for a 20 yr. finish warranty, but Section 08520: 1.1 3.1 (c) calls for a 10 yr. finish warranty. A 5-year material warranty and a 20-year finish warranty are included. Warranty on workmanship is for a period of two (2) years from the date of substantial completion.
|
32.
|
Warranties from the manufacturer (ACCURA) and Glass Contractor/Installer will be issued separately and will not be jointly signed (Re: 08400-9-1.13-B).
|
33.
|
An insulated glass manufacturer warranty against glass breakage is not available. Glass Contractor/lnstaller and ACCVRA will replace glass damaged by their workmanship (Re: Section 08400-9-1.13-B & Section 08520).
|
34.
|
The specified U-Factor of .08 is not attainable. The aluminum framing system being provided is tested to meet a U-Value of .50 at all frames except the stair towers, and a .59 U-Factor at the stair tower curtainwalls (Re: 08400-6-1.6-E.2).
|
35.
|
All field testing shall be done in accordance with AAMA and ASTM. In accordance with these entities, a field tested product is not required to meet the same performances as the laboratory tested frame. (Re: 08400-11-3.3-C). An informal non certified laboratory test will be completed at Service Glass' shop in Frederick, MD, including the stainless steel cavity closure. Test will be conducted using AAMA guidelines. Onsite field testing will be by Service Glass Personnel using AAMA 501.2 and ASTM standards. No other field testing is to be done other than the 501.2 hose test. Glass Contractor workmanship warranty duration is for a duration of two (2) years. ACCURA will warrant materials for a 5-year duration but this does not include labor; it is a parts only warranty. (Re: 08410-4-1.4-A).
|
36.
|
Glass Contractor workmanship warranty duration is for a duration of two (2) years. ACCURA will warrant
|
materials for a 5-year duration but this does not include labor; it is a parts only warranty. (Re: 08410-4-1.4-A).
37.
|
Specification Section 08410 paragraph A specifies a ten-year material warranty and paragraph B specifies a 5-year warranty for aluminum entrances. A 5-year warranty is provided.
|
38.
|
Condensation Window System Warranties will be provided using AAMA 1503 criteria with regards to system thermal performance and will be limited to laboratory testing comparisons excluding job specific construction details. Limited Thermal Computer Modeling shall be provided by Accura to better assist in the understanding of how their products may perform in job specific applications.
|
39.
|
Specification Section 08410-7-2.3-A.8 is excluded. The aluminum curtainwall system specified or proposed does not utilize flashing.
|
40.
|
Specification Section 08410-8-2.4-I is excluded. The aluminum curtainwall system specified or proposed does not utilize Concealed Flashing.
|
41.
|
Specification Section 08410-7-2.3-A.6.b is excluded. Mechanical fastening of standard 3/4" deep face covers is not an industry standard practice, and is not required.
|
42.
|
The aluminum framing system has a 20-year finish warranty per the Fluoropolymer Finish Section (Re: 05080-1-1.5) in lieu of the ten-year duration mentioned in the Aluminum windows Section (Re: 00000-0-0.00-X.xx).
|
43.
|
Aluminum framing system Specification Section 08520 calls for a 5-year material duration which is in agreement with paragraph B of the Aluminum Entrances and Window Walls specification (Re: 08410-4-1.4-B)
|
44.
|
The glass warranty from the specified manufacturer for fritted and silkscreened glass is a of 5-year warranty, not a ten-year warranty as specified (Re: 08800-6-1.14-A).
|
45.
|
Certifications and manufacturers or subcontractors special statements indicated in Specification Section 08800-2-1.5-B are may not be available from the manufacturers. These will be available when available.
|
46.
|
Note the following manufacturer notes regarding warranties as they apply to edge flaws (Re: 08800-6-1.14-A.2 and 3):
|
•
|
The following conditions will be considered unacceptable for annealed glass. These conditions are allowable in heat-treated glass provided dimensional tolerances are met:
|
• Vee chips.
• Shark teeth that exceed one half of the glass thickness.
• Serration hackle which exceeds one quarter of the glass thickness or if spalling is present.
• A flare that exceeds one eighth of the glass thickness.
• A bevel that exceeds one quarter of the glass thickness.
• Plier-nipped edges.
• The following is allowable for heat treated glass.
• Shell Chips which exceed the following dimensions:
a. Covered Edge: 1/4" (6mm) L X 1/4" (6mm) W Max.
b. Exposed Edge: 1/4" (6mm) L X 1/8" (3mm) W Max.
•
|
These edge conditions will not affect glass strength in heat-treated glass when they exist prior to heat-treating. This process is severe and will break glass with weakening edge conditions.
|
47.
|
Except for the Visual Mock-up, samples are based on providing manufacturers' standard size samples. Special size samples are not included (Re: 08400-2-1.3-F, 08410-3-1.3-F, 08520-3-1.3-H, and 08800-2-1.3-B).
|
48.
|
Calculations for the exterior curtainwall and window performance will be submitted after the Architect has completed their review of the shop drawings so that changes may be included in the calculations. (Re: 08400-3-1.4-B,08410-3-I.3-C,and 08520-3-1.4). Calculationswillbeprovidedinbookletformincorporatingdetailsfromthe shop drawings. The shop drawings themselves are not stamped since they incorporate materials from other trades (e.g. concrete, metal studs, precast. etc.).
|
49.
|
The glazing aluminum framing system will have a I-coat 30% Kynar interior finish on the interior side per accepted Value Engineering.
|
50.
|
The vertical connection detail of the exterior sunshades will differ from that indicated on design drawings. A 2-1/2" deep face cover is not included. A 3/4" thick blade located on-center of the mullions with the sunshades attached to blade and meeting in the center of the mullion is being provided (Re: I I and 12/A.461).
|
51.
|
Breakmetal comers will be provided for the glazing aluminum framing system in lieu of larger custom extrusions shown on detail Ion A.462,subject to architect and Curtainwall consultant's review and approval.
|
52.
|
Glass & Glazing Warranties on materials will be per each manufacturer's standard available warranties. Warranties will be supplied on the manufacturer's letterhead, inclusive of their standard language and limitations, which may be in conflict with the specifications. (Re: 07900-8-1.16, 00000-0-0.l3, 08410-4-1.4, 00000-0-0.l3, 08710-I-1.6, and 00000-0-0.l4).
|
53.
|
The curtainwall system has been tested in accordance with AAMA 1503 with regards to thermal performance (Re: 08520-6-1.6-D). Any special indoor/outdoor temperatures or relative humidity has not been tested (Re: 08400 -6-1.6-G). Laboratory testing is not included, however, up to three computer-generated thermal models can be provided.
|
54.
|
Performance mock-up and independent testing of curtainwall or exterior envelope systems are not included. A production run window unit will be air & water tested at Glazing Contractor's local facility. On site testing is limited to hose test.
|
55.
|
No Shadowboxes have been included at glazing systems.
|
56.
|
The glazing aluminum framing system is designed in accordance with IBC 2006 and per exposure category B as listed in the Exterior Wall Performance Requirements Section (Re: 08400-5-1.6-C.2.b2) and the Structural Notes (Re: S.100), and not exposure category C as listed in the Aluminum Entrances and Window Wall Section (Re: 08410-5-1.5-B.a).
|
Mechanical System Clarifications:
57.
|
Heat Exchanger Thermal Capacity Calculations as noted in Specification Section 15766 are assumed to be by the Design Team and are therefore excluded.
|
58.
|
Geothermal Heat Exchanger Design Parameters as noted in Specification Section 15766-3.1 are assumed to be by the Design Team.
|
59.
|
As the layout and routing of the Geothermal Xxxxx will be located by survey to match the layout locations shown on drawing M-102, geothermal well shop drawings are excluded.
|
60.
|
Seismic Requirements for MEP work are not included. WT to provide vibration isolation as specified in mechanical specification section 15925.
|
61.
|
Rooftop Air Handling Units are custom units manufactured by York.
|
62.
|
Ice-making Chiller is based on York. Non-ice-making Chiller is based on XxXxxx.
|
63.
|
GMP is based on providing a code compliant sprinkler system. PRVs at individual valves will not be provided.
|
64.
|
Zinc Chromate Primer for all pipe hangers, anchors and supports is excluded. Galvanized Pipe supports and hangers will be provided.
|
Electrical System Clarifications:
65.
|
Wiring in concrete ductbanks shall be installed in schedule 40 PVC conduit. Wiring on site or under the building slab shall be installed in schedule 40 PVC conduit.
|
66.
|
Electrical branch circuit wiring shall be MC or AC cable as allowed by NEC, except in the Mechanical Room where branch circuit wiring will be installed in EMT conduit.
|
67.
|
Empty conduit for Audio-Visual system wiring is provided per the Audio-Visual drawings. Empty conduit noted for the AV system on the electrical drawings shall be included as well.
|
68.
|
Telecommunications outlet drops are provided as a 1"conduit stub to accessible (lay-in tile) ceilings. Conduit home runs back to the closets or cable tray as indicated on some drawings is not included per accepted Value Engineering.
|
69.
|
Empty conduit and boxes for the Security System is provided per the Security drawings.
|
70. Electrical conduit fittings shall be steel set screw per accepted Value Engineering.
71.
|
Specification Section 16420 2.1.D indicates that if the equipment does not fit in the rooms as designed, the contractor is to provide customized equipment to ensure all equipment will fit. It is assumed that specified equipment will fit into the designed rooms. Customized equipment is not provided.
|
72.
|
Specification Section 16225 3.2.A.9.b has a requirement for hydrostatic testing of the emergency generator fuel tank. The manufacturer will not allow water to be installed in the fuel tank; hence pneumatic testing of the tank is provided.
|
73.
|
The acoustical enclosure for each emergency generator will be a Generac ultra quite low profile unit rated 75dba @ 23 feet (7 meters).
|
74.
|
Functional performance testing and acceptance testing as noted in Specification Section 16995 is included. This testing is based on what is indicated on the drawings and in specifications; design intent is not included.
|
75.
|
Specification Section 16995 2.2A calls for proprietary test equipment and software to become the property of the user after testing. This may not be available from certain manufacturers/vendors.
|
76.
|
The electrical short circuit coordination study per Specification Section 16420 is included. The anticipated costs to modify the design based on the initial short circuit study have been included in this proposal. Upon review of the study, the design team will review and confirm report recommendations. Final design must be provided by the design team.
|
77.
|
Specification Section 16450 for Grounding requires the system to achieve a value of no higher than 5 ohms. Testing is included; however, modifications to the system to achieve the 5 ohm requirement (if the test results in higher than 5 ohms) are not included.
|
78.
|
Many of the wall box dimmers for various rooms are not shown correctly. (Two circuits can not be controlled by one dimmer). Re-circuiting the fixtures to be controlled by one dimmer is included.
|
79.
|
A P.E. Stamp for the Fire Alarm drawing submission is not provided. Loudoun County requires the Engineer of Record (WSP/F+K) to PE Stamp the drawings and submittals for the Fire Alarm Permit. These stamped documents will be provided at no cost to the Construction Manager.
|
80.
|
Specification Section 16225 -2.18 -G (last sentence) states "For applications in which load shedding with the transfer switch is not feasible, load shedding requirements will be evaluated and accommodated as necessary." Additional work associated with this accommodation is excluded.
|
81. Clarifications to the Quad Logic Electronic Sub-Metering System Specification are as follows:
a.
|
1.4A -The system will be pre-installed in the appropriate panels by the panel vendor and will be installed at their factory. No manufacturer supervision will be required.
|
b.
|
2.1.B.5 -As the system will tie into the BMS system, no separate printer will be provided for the Sub-metering system.
|
c.
|
3.1.C is excluded. Sub-metering billing is not applicable to this project.
|
82.
|
Furniture whips will be provided by others. Connections from whip to the junction boxes shown on the Contract Documents are included.
|
83.
|
Electrical Systems Identification will be similar to Specification Section 16005. A comprehensive labeling system and samples will be provided for Owner input and approval.
|
84.
|
Drawing E-500 indicates fused switch distribution equipment. Circuit breaker configurations are required to allow the equipment to fit in the indentified space. These circuit breakers are included.
|
85.
|
Clarifications to the Lighting Control System are as follows:
|
a.
|
The Ecosystem will be deployed around the perimeter of the building and control the fixtures that are
|
typically installed within 15' -20' of the window line. Ecosystems shall be deployed as detailed on
|
|
drawings and specifications.
|
|
b.
|
Standard 14KAIC breakers are included for dimming panels.
|
c.
|
Two-year standard warranty is provided.
|
d.
|
Eight-year prorated parts warranty is provided.
|
86.
|
Cable Tray outside of tele/data rooms is provided. Cable Tray inside of tele/data rooms is to be provided by the Owner's Tele/Data Vendor.
|
END
EXHIBIT C
ALLOWANCE ITEMS
May 17, 2010
The Amendment No. I GMP contains several Allowances for items of work whose quantity or quality cannot be positively identified on the Contract Documents or on site inspection. These allowance items are so identified as 'Allowance' or 'AL' in the 'unit' column of the GMP Schedule of Values. The allowances establish a level of quality or quantity for these items based upon assumption. Should the eventual cost of these allowances vary up or down, then the GMP will be adjusted accordingly.
The following Allowances are included in the GMP:
|
|
Dewatering & French Drains
|
$ 15,000
|
Asphalt Pavement Material Cost Modifier
|
$ 15,000
|
Foot Bridges at Walking Trails
|
$ 25,000
|
Site Sleeving for Irrigation, Security, Site Lighting, Etc...
|
$ 85,000
|
Site Conduit for Telephone Service and Building Floor Boxes
|
$200,000
|
Reception Desk
|
$ 68,000
|
Electronic/Security Door Hardware Premium
|
$ 15,000
|
Exterior Visual Mock-up
|
$ 42,000
|
Graphics Allowance for Skyfold Doors
|
$ 16,000
|
Entrance Gates & Operators
|
$ 50,000
|
Trench Rock Allowance
|
$ 18,000
|
PV Panels and Electric work at the Storage Facility
|
$ 60,000
|
Revised Guardrail Detail
|
$ 10,000
|
York Chiller -Supply Differential Pressure Switch in Lieu of Flow Switch
|
$ 1,200
|
York Chiller -Fully enclose each compressor with acoustic sound blankets
|
$ 5,600
|
XxXxxx Chiller -Add Double Insulation (1.5" in lieu of 3/4")
|
$ 2,200
|
XxXxxx Chiller -Add 2 year parts & Labor Warranty
|
$ 5,200
|
XxXxxx Chiller -Marine Water Boxes for both the evaporator and condenser
|
$ 1,900
|
Additional electronic metering
|
$ 21,000
|
Potential Changes to Generator and Enclosure
|
$ 95,000
|
Potential Changes to Dimming System per Design Coordination Meeting
|
$ 25,000
|
Project Name:
|
NRUCFC Headquarters
|
WT VP/Group:
|
Xxxxx
|
Type of Project:
|
|||||
WT |
HQ Office Building with Fit-up
|
Architect:
|
Kishimoto.Xxxxxx.Xxxxxx
|
3-Story 121,041 SF Office Building with Full Fit-up, 277 Space Parking Lot & Site Work
|
|||||
100 |
Document Set:
|
100% Construction Documents
|
|||||||
Years |
dated October 23, 2009
|
LEED: GOLD
|
|||||||
Type of Bid:
|
GMP 100% CD's
|
Addendums #1 & #2
|
|||||||
Project Location:
|
Loudoun County, VA
|
Site Area: 19 Acres
|
|||||||
Owner:
|
NRUCFC
|
Office Building:
|
121,041
|
GSF
|
Start Date: March 2010
|
||||
Date:
|
May 17, 2010
|
Total:
|
121,041
|
GSF
|
Schedule: 16 months
|
||||
5/21/2010
EXHIBIT D – SCHEDULE OF VALUES
|
100% CD TOTAL PROJECT
|
||||||
121,041
|
GSF
|
||||||
Division
|
COST
|
$/GSF
|
Comments
|
||||
1
|
General Conditions/ Requirements
|
$
|
1,532,000
|
$
|
12.66
|
||
2
|
Site Work
|
$
|
2,250,651
|
$
|
18.59
|
||
3
|
Concrete
|
$
|
1,748,315
|
$
|
14.44
|
||
4
|
Masonry
|
$
|
2,358,200
|
$
|
19.48
|
||
5
|
Metals
|
$
|
2,701,137
|
$
|
22.32
|
||
6
|
Wood & Plastics
|
$
|
1,426,140
|
$
|
11.78
|
||
7
|
Thermal & Moisture Protection
|
$
|
1,496,025
|
$
|
12.36
|
||
8
|
Doors & Windows
|
$
|
4,064,900
|
$
|
33.58
|
||
9
|
Finishes
|
$
|
3,780,600
|
$
|
31.23
|
||
10
|
Specialties
|
$
|
607,852
|
$
|
5.02
|
||
11
|
Equipment
|
$
|
192,900
|
$
|
1.59
|
||
12
|
Furnishings
|
$
|
204,190
|
$
|
1.69
|
||
13
|
Special Conditions
|
$
|
-
|
$
|
-
|
||
14
|
Conveying Systems
|
$
|
366,000
|
$
|
3.02
|
||
15
|
Mechanical Systems
|
$
|
9,019,600
|
$
|
74.52
|
||
16
|
Electrical Systems
|
$
|
5,397,150
|
$
|
44.59
|
||
Subtotal
|
$
|
37,145,660
|
$
|
306.88
|
|||
Construction Company
|
LS
|
$
|
800,000
|
$
|
6.61
|
||
Design Contingency
|
0.00%
|
$
|
-
|
$
|
-
|
Not Carried.
|
|
XX Xxxx
|
0.00%
|
$
|
-
|
$
|
-
|
Waived.
|
|
Builder’s Risk Insurance
|
0.00%
|
$
|
-
|
$
|
-
|
By Owner.
|
|
GC Liability Insurance & GR Tax
|
0.90%
|
$
|
341,511
|
$
|
2.82
|
||
Escalation
|
0.00%
|
$
|
-
|
$
|
-
|
||
Lumped Sum GC Fee
|
LS
|
$
|
1,200,000
|
$
|
9.91
|
||
PHASE II CONSTRUCTION ESTIMATE
|
$
|
39,487,171
|
$
|
326.23
|
|||
Notes:
|
|||||||
1
|
Refer to Contractor Clarifications for further definition of scope.
|
||||||
2
|
Includes Modifications #1 & 2.
|
NRUCFC Headquarters Total Project Summary
5/21/2010
1
|
GENERAL CONDITIONS/ REQUIREMENTS
|
||||||
GENERAL CONDITIONS / REQUIREMENTS
|
$ 1,532,000
|
||||||
General Conditions/ General Requirements
|
1
|
LS
|
$ 1,532,000
|
$ 1,532,000
|
Phase II
|
||
Total General Conditions/ Requirements
|
$ 1,532,000
|
||||||
2
|
SITE WORK
|
||||||
GENERAL MOBILIZATION & DEMOBILIZATION
|
$ 277,000
|
||||||
Layout & Control
|
1
|
LS
|
$ 43,200
|
$ 43,200
|
Building Survey
|
||
Perimeter Fencing & Barricades
|
1
|
LS
|
$ 33,000
|
$ 33,000
|
|||
Temporary Access Roads
|
1
|
LS
|
$ 49,000
|
$ 49,000
|
|||
Soil Treatment/Pest Control
|
1
|
LS
|
$ 2,900
|
$ 2,900
|
|||
Temporary Site Signage
|
1
|
LS
|
$ 7,000
|
$ 7,000
|
|||
Construction Waste Removal & Recycling
|
1
|
LS
|
$ 65,000
|
$ 65,000
|
75% LEED Requirement.
|
||
Trash Chute
|
1
|
LS
|
$ 8,900
|
$ 8,900
|
|||
Final Cleaning
|
1
|
LS
|
$ 68,000
|
$ 68,000
|
Cleaning Contractor.
|
||
TREE PRESERVATION
|
$ 47,000
|
||||||
Tree Care Maintenance for Trenching
|
1
|
LS
|
$ 23,000
|
$ 23,000
|
Trenching Through Xxxxx.
|
||
Tree Care Maintenance Post Construction
|
1
|
LS
|
$ 24,000
|
$ 24,000
|
During-Construction.
|
||
EARTHWORK
|
$ 172,450
|
||||||
Sediment Control Maintain & Remove
|
1
|
LS
|
$ 48,000
|
$ 48,000
|
|||
Sediment Control for Drilling Operation
|
1
|
LS
|
$ 6,700
|
$ 6,700
|
|||
Temporary Seeding
|
1
|
LS
|
$ 11,100
|
$ 11,100
|
|||
Temporary Water Service
|
1
|
LS
|
$ 5,600
|
$ 5,600
|
|||
Temporary Water for Geothermal Well Drilling Operation
|
1
|
LS
|
$ 4,450
|
$ 4,450
|
|||
Spoil Management for Post Geothermal Well Drilling Operation
|
1
|
LS
|
$ 4,300
|
$ 4,300
|
|||
Backfill Site Walls
|
1
|
LS
|
$ 31,200
|
$ 31,200
|
From Onsite Borrow
|
||
Fine grade Site
|
1
|
LS
|
$ 27,100
|
$ 27,100
|
Post Construction.
|
||
Final Grade Building Pad
|
1
|
LS
|
$ 19,000
|
$ 19,000
|
|||
Dewatering & French Drains
|
1
|
AL
|
$ 15,000
|
$ 15,000
|
Uncertain Scope.
|
||
SITE UTILITIES & PAVING / CURB & GUTTER
|
$ 84,201
|
||||||
Install Building Utility Laterals
|
1
|
LS
|
$ 14,100
|
$ 14,100
|
|||
Revised Drawings for Tree Well Drains
|
1
|
LS
|
$ 50,501
|
$ 50,501
|
Xxxxx CO.
|
||
Asphalt Pavement Material Cost Modifier
|
1
|
AL
|
$ 15,000
|
$ 15,000
|
For Delayed Paving Activity.
|
||
Misc. Minor Permits and Inspections
|
1
|
LS
|
$ 4,600
|
$ 4,600
|
|||
SITE CONCRETE
|
$ 296,000
|
||||||
Site Concrete Walls, Stairs, Walks & Pads
|
1
|
LS
|
$ 296,000
|
$ 296,000
|
|||
UNIT PAVING
|
$ 20,200
|
||||||
Site Unit Paving
|
1
|
LS
|
$ 20,200
|
$ 20,200
|
|||
Site Stone Pavers
|
1
|
LS
|
$ -
|
$ -
|
See Division 4 Stone.
|
||
SITE STONE WALLS
|
$ 63,200
|
||||||
Stone Walls (Type A)
|
1
|
LS
|
$ -
|
$ -
|
In Site Concrete & Masonry.
|
||
Stone Gravity Walls (Type B)
|
1
|
LS
|
$ 63,200
|
$ 63,200
|
|||
LANDSCAPING
|
$ 879,000
|
||||||
Landscaping & Planting Materials
|
1
|
LS
|
$ 850,000
|
$ 850,000
|
|||
Irrigation Tap West of Bridge
|
1
|
LS
|
$ 3,000
|
$ 3,000
|
|||
Irrigation Backflow Preventer West of Bridge
|
1
|
LS
|
$ 5,000
|
$ 5,000
|
Meter by CFC.
|
||
Landscape Maintenance
|
1
|
LS
|
$ 21,000
|
$ 21,000
|
During Construction.
|
||
HARDSCAPE
|
$ 126,600
|
||||||
Site Furnishings
|
1
|
LS
|
$ 91,300
|
$ 91,300
|
|||
Flagpoles & Base
|
1
|
LS
|
$ 10,300
|
$ 10,300
|
|||
Foot Bridges at Walking Trails
|
1
|
AL
|
$ 25,000
|
$ 25,000
|
|||
STORAGE FACILITY
|
$ -
|
||||||
Provide the Exterior Storage Building. Reduced Scope
|
1
|
LS
|
$ -
|
$ -
|
In Subcontractor Quotes
|
||
SLEEVING
|
$ 285,000
|
||||||
Sleeving for Irrigation, Security, Site Lighting, Etc…
|
1
|
AL
|
$ 85,000
|
$ 85,000
|
Uncertain Scope.
|
||
Conduit for Telephone Service
|
1
|
AL
|
$ 200,000
|
$ 200,000
|
|||
Total Site Work
|
$ 2,250,651
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
3
|
CONCRETE
|
||||||
STRUCTURAL CONCRETE
|
$ 1,379,560
|
||||||
Structural Concrete
|
1
|
LS
|
$ 1,195,000
|
$ 1,195,000
|
|||
Rock Over-excavation and Lean Fill
|
1
|
LS
|
$ 25,000
|
$ 25,000
|
|||
Supplemental Concrete Work
|
1
|
LS
|
$ 32,000
|
$ 32,000
|
|||
Winter Protection / Admixtures / Heat
|
1
|
LS
|
$ 30,000
|
$ 30,000
|
Tenting, Heaters & Fuel.
|
||
Concrete Pads for Potable Water & Ice Storage Tanks
|
1
|
LS
|
$ 19,000
|
$ 19,000
|
|||
100% Construction Document Changes
|
1
|
LS
|
$ 57,906
|
$ 57,906
|
XX Xxxxxx CO.
|
||
XX Xxxxxx Addendum #2
|
1
|
LS
|
$ 20,654
|
$ 20,654
|
XX Xxxxxx CO.
|
||
ARCHITECTURAL CAST STONE
|
$ 368,755
|
||||||
Architectural Cast Stone
|
1
|
LS
|
$ 368,755
|
$ 368,755
|
Xxxxx Set, in Division 4.
|
||
Total Concrete
|
$ 1,748,315
|
||||||
4
|
MASONRY
|
||||||
UNIT MASONRY
|
$ 1,278,200
|
||||||
Brick Masonry and Stone Veneer (ST-1)
|
1
|
LS
|
$ 1,278,200
|
$ 1,278,200
|
Includes Setting Cast Stone.
|
||
NATURAL CUT STONE
|
$ 1,080,000
|
||||||
Interior & Exterior Cut Stone & Paving
|
1
|
LS
|
$ 1,090,000
|
$ 1,090,000
|
|||
Per Alternate 4.1 - Provide 3.5" Stone Pavers at Vehicular locations in lieu of 4.5" at Rear Courtyard
|
1
|
LS
|
$ (10,000)
|
$ (10,000)
|
|||
Stone Graphics Allowance
|
1
|
AL
|
$ -
|
$ -
|
By Owner
|
||
Total Masonry
|
$ 2,358,200
|
||||||
5
|
METALS
|
||||||
STRUCTURAL STEEL
|
$ 1,986,599
|
||||||
Structural Steel Framing
|
1
|
LS
|
$ 1,694,286
|
$ 1,694,286
|
|||
Supplemental Steel Framing
|
1
|
LS
|
$ 40,000
|
$ 40,000
|
|||
100% Construction Document Changes
|
1
|
LS
|
$ 46,172
|
$ 46,172
|
SteelFab CO.
|
||
Addendum 1 Drawing Revisions
|
1
|
LS
|
1,241
|
$ 1,241
|
|||
Addendum 2 and Window Washing Changes
|
1
|
LS
|
58,980
|
$ 58,980
|
|||
Curved Railing Structural Steel Support at Atrium RFI P2-054
|
1
|
LS
|
25,978
|
$ 25,978
|
|||
Approval Comments and Design Changes
|
1
|
LS
|
90,000
|
$ 90,000
|
|||
Precast at Front Entry Angle (RFI P2-119)
|
1
|
LS
|
10,388
|
$ 10,388
|
|||
RFI P2-089, 090 - Front Entry (Triangle Framing)
|
1
|
LS
|
19,553
|
$ 19,553
|
|||
MISCELLANEOUS METALS
|
$ 553,438
|
||||||
Miscellaneous Metals & Greenscreen
|
1
|
LS
|
$ 495,000
|
$ 495,000
|
|||
Increase C-Channel of Stair Stringers to Match Structural Members
|
1
|
LS
|
$ 3,138
|
$ 3,138
|
|||
Upgrade Exterior Guardrails
|
1
|
AL
|
$ 10,000
|
$ 10,000
|
|||
Misc. Supports and Angles
|
1
|
LS
|
$ 22,300
|
$ 22,300
|
|||
Roof Doghouses
|
1
|
LS
|
$ 15,000
|
$ 15,000
|
|||
Cooling Tower Dunnage
|
1
|
LS
|
$ 8,000
|
$ 8,000
|
|||
ORNAMENTAL METALS
|
$ 161,100
|
||||||
Ornamental Metals & Glass Rails
|
1
|
LS
|
$ 161,100
|
$ 161,100
|
|||
Total Metals
|
$ 2,701,137
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
6
|
WOOD & PLASTICS
|
||||||
ROUGH CARPENTRY
|
$ 179,140
|
||||||
Wood Blocking & Sheathing
|
1
|
LS
|
$ 73,200
|
$ 73,200
|
|||
Install Doors, Frames & Hardware
|
1
|
LS
|
$ 86,140
|
$ 86,140
|
Furnished Division 8.
|
||
Install Specialties
|
1
|
LS
|
$ 19,800
|
$ 19,800
|
Furnished Division 10.
|
||
MILLWORK
|
$ 1,179,000
|
||||||
Millwork
|
1
|
LS
|
$ 1,143,000
|
$ 1,143,000
|
|||
Panels for Modernfold Door
|
1
|
LS
|
$ 36,000
|
$ 36,000
|
|||
RECEPTION DESK
|
$ 68,000
|
||||||
Reception Desk
|
1
|
AL
|
$ 68,000
|
$ 68,000
|
Per Fox Direction.
|
||
Total Wood & Plastics
|
$ 1,426,140
|
||||||
7
|
THERMAL & MOISTURE PROTECTION
|
||||||
WATERPROOFING
|
$ 252,390
|
||||||
Waterproofing
|
1
|
LS
|
$ 38,900
|
$ 38,900
|
|||
Foundation Drainage
|
1
|
LS
|
$ 24,090
|
$ 24,090
|
|||
Air Barriers
|
1
|
LS
|
$ 186,400
|
$ 186,400
|
At Cavity Walls.
|
||
Traffic Topping at Plumbing and Fire Pump Room
|
1
|
LS
|
$ 3,000
|
$ 3,000
|
|||
ROOFING
|
$ 860,755
|
||||||
Membrane Roofing
|
1
|
LS
|
$ 681,300
|
$ 681,300
|
At Dome & Main Roof.
|
||
Metal Roofing
|
1
|
LS
|
$ 179,455
|
$ 179,455
|
Zinc Roofing.
|
||
METAL PANEL SCREEN WALLS
|
$ 153,450
|
||||||
Metal Panel Screen Walls
|
1
|
LS
|
$ 153,450
|
$ 153,450
|
Roof Screen and Generator.
|
||
CAULKING & SEALANTS
|
$ 73,130
|
||||||
Interior & Exterior Caulking
|
1
|
LS
|
$ 52,130
|
$ 52,130
|
|||
Fire Sealants
|
1
|
LS
|
$ 21,000
|
$ 21,000
|
|||
FIREPROOFING
|
$ 156,300
|
||||||
Spray Fireproofing
|
1
|
LS
|
$ 156,300
|
$ 156,300
|
|||
Intumescent Fireproofing
|
1
|
LS
|
$ -
|
$ -
|
None Required.
|
||
Total Thermal & Moisture Protection
|
$ 1,496,025
|
||||||
8
|
DOORS & WINDOWS
|
||||||
DOORS & HARDWARE
|
$ 276,500
|
||||||
Doors, Frames & Hardware
|
1
|
LS
|
$ 261,500
|
$ 261,500
|
|||
Electronic/Security Door Hardware Premium
|
1
|
AL
|
$ 15,000
|
$ 15,000
|
|||
COILING DOORS
|
$ 183,000
|
||||||
Overhead Coiling Doors
|
1
|
LS
|
$ 19,000
|
$ 19,000
|
|||
Side Coiling Firedoors
|
1
|
LS
|
$ 164,000
|
$ 164,000
|
|||
GLAZING & CURTAINWALLS
|
$ 3,484,000
|
||||||
Glazing & Curtainwalls
|
1
|
LS
|
$ 3,450,000
|
$ 3,450,000
|
Base GMP Based on Accepted VE Glass - Bendheim #CNRS-586
|
||
Per Alternate 8.1 - Provide Oldcastle SunGlass w/Argon
|
1
|
LS
|
$ (18,000)
|
$ (18,000)
|
|||
Per Alternate 8.2 - Provide frit at colonnade glass glass per ASK-032
|
1
|
LS
|
$ 9,000
|
$ 9,000
|
|||
Add Intermediate Caulk Bead to Glazing Sytem
|
1
|
LS
|
$ 43,000
|
$ 43,000
|
|||
SKYLIGHTS
|
$ 64,400
|
||||||
Oculus Glass Skylight
|
1
|
LS
|
$ 64,400
|
$ 64,400
|
|||
VISUAL MOCK-UP
|
$ 57,000
|
||||||
Exterior Visual Mock-up
|
1
|
AL
|
$ 42,000
|
$ 42,000
|
|||
Travel for Mock-up & Material Verification
|
1
|
LS
|
$ 15,000
|
$ 15,000
|
|||
Total Doors & Windows
|
$ 4,064,900
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
9
|
FINISHES
|
||||||
DRYWALL & ACOUSTICAL CEILINGS
|
$ 2,341,600
|
||||||
Drywall, Light Gauge Framing & Acoustical Ceilings
|
1
|
LS
|
$ 2,309,000
|
$ 2,309,000
|
|||
Drywall Patching & Point-up
|
1
|
LS
|
$ 12,000
|
$ 12,000
|
|||
Duct Shaft Enclosures
|
1
|
LS
|
$ 16,400
|
$ 16,400
|
|||
Access Doors
|
1
|
LS
|
$ 4,200
|
$ 4,200
|
|||
ACOUSTICAL ASSEMBLIES
|
$ 74,080
|
||||||
Acoustical Wall Panels
|
1
|
LS
|
$ 74,080
|
$ 74,080
|
|||
FLOORING
|
$ 745,720
|
||||||
Carpet, Resilient, Wood & Cork Flooring
|
1
|
LS
|
$ 695,000
|
$ 695,000
|
|||
Per Alternate 9.3 - Provide Junkers, Merbau species solid wood flooring (WD-3 and WD-4) in lieu of Hickory Wood Flooring (WD-1 and WD-2).
|
1
|
LS
|
$ (16,500)
|
$ (16,500)
|
|||
Raised Access Floor
|
1
|
LS
|
$ 39,120
|
$ 39,120
|
Based on Xxxxxxxx Tec-Crete
|
||
Floor Preparation
|
1
|
LS
|
$ 20,000
|
$ 20,000
|
|||
Floor Protection
|
1
|
LS
|
$ 8,100
|
$ 8,100
|
|||
PAINTING & FINISHES
|
$ 309,200
|
||||||
Painted Finishes & Wallcovering
|
1
|
LS
|
$ 302,200
|
$ 302,200
|
|||
Punchlist Touch-up
|
1
|
LS
|
$ 7,000
|
$ 7,000
|
|||
CERAMIC TILE
|
$ 285,000
|
||||||
Ceramic & Porcelain Tile
|
1
|
LS
|
$ 285,000
|
$ 285,000
|
|||
SCAFFOLDING
|
$ 25,000
|
||||||
Scaffold for High Work
|
1
|
LS
|
$ 25,000
|
$ 25,000
|
|||
Total Finishes
|
$ 3,780,600
|
||||||
10
|
SPECIALTIES
|
||||||
BATHROOM ACCESSORIES
|
$ 49,300
|
||||||
Toilet & Shower Accessories
|
1
|
LS
|
$ 37,210
|
$ 37,210
|
|||
Lockers & Benches
|
1
|
LS
|
$ 12,090
|
$ 12,090
|
|||
OPERABLE DOORS
|
$ 454,732
|
||||||
Skyfold & Sliding Wall Operable Partitions
|
1
|
LS
|
$ 438,732
|
$ 438,732
|
At First Floor Conference.
|
||
Graphics Allowance for Skyfold Doors
|
1
|
AL
|
$ 16,000
|
$ 16,000
|
|||
SPECIALTIES
|
$ 53,820
|
||||||
Architectural Wall Louvers
|
1
|
LS
|
$ 8,120
|
$ 8,120
|
|||
Gas Fireplace
|
1
|
LS
|
$ 23,800
|
$ 23,800
|
|||
Fire Extinguisher Cabinets
|
1
|
LS
|
$ 5,400
|
$ 5,400
|
|||
Wall & Corner Protection
|
1
|
LS
|
$ 13,900
|
$ 13,900
|
|||
Xxxx Box
|
1
|
LS
|
$ 600
|
$ 600
|
|||
Bird Spikes
|
1
|
LS
|
$ 2,000
|
$ 2,000
|
|||
Mobile Storage Systems
|
1
|
LS
|
$ -
|
$ -
|
Add Alternate.
|
||
SIGNAGE
|
$ -
|
||||||
Building Life Safety Signage
|
1
|
AL
|
$ -
|
$ -
|
Code Compliant (By Owner)
|
||
Building Signage & Directory
|
1
|
AL
|
$ -
|
$ -
|
By Owner
|
||
Site, Directional & Trail Signage
|
1
|
AL
|
$ -
|
$ -
|
By Owner
|
||
Monumental Entrance Sign
|
1
|
LS
|
$ -
|
$ -
|
In Divisions.
|
||
Interior Graphics Allowance
|
1
|
AL
|
$ -
|
$ -
|
By Owner
|
||
FENCING
|
$ 50,000
|
||||||
Entrance Gates & Operators
|
1
|
AL
|
$ 50,000
|
$ 50,000
|
|||
Total Specialties
|
$ 607,852
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
11
|
EQUIPMENT
|
||||||
EQUIPMENT
|
$ 41,400
|
||||||
Dock Bumpers
|
1
|
LS
|
$ 1,400
|
$ 1,400
|
|||
Window Washing Anchors
|
1
|
LS
|
$ 40,000
|
$ 40,000
|
|||
PANTRY RESIDENTIAL APPLIANCES
|
$ 38,100
|
||||||
Residential Appliances
|
1
|
LS
|
$ 38,100
|
$ 38,100
|
Café Prep & Exec. Lounge.
|
||
KITCHEN EQUIPMENT
|
$ 91,100
|
||||||
Commercial Kitchen Equipment
|
1
|
LS
|
$ 91,100
|
$ 91,100
|
|||
AUDIO VISUAL EQUIPMENT
|
$ 22,300
|
||||||
Motorized Projection Screens
|
1
|
LS
|
$ 22,300
|
$ 22,300
|
|||
Audio-Visual Equipment
|
1
|
N/A
|
$ -
|
$ -
|
By Owner
|
||
PAGING SYSTEM
|
$ -
|
||||||
Paging System
|
1
|
N/A
|
$ -
|
$ -
|
None Required
|
||
SECURITY SYSTEM
|
$ -
|
||||||
Security System
|
1
|
N/A
|
$ -
|
$ -
|
By Owner
|
||
Total Equipment
|
$ 192,900
|
||||||
12
|
FURNISHINGS
|
||||||
ENTRANCE MATS
|
$ 8,990
|
||||||
Walk-Off Mat
|
1
|
LS
|
$ 8,990
|
$ 8,990
|
|||
WINDOW TREATMENT
|
$ 195,200
|
||||||
Electronic & Manual Roller Shades
|
1
|
LS
|
$ 195,200
|
$ 195,200
|
|||
Total Furnishings
|
$ 204,190
|
||||||
13
|
SPECIAL CONSTRUCTION
|
||||||
PHOTOVOLTAICS
|
$ -
|
||||||
PV Panels
|
1
|
LS
|
$ -
|
$ -
|
See Pavilion Alternate.
|
||
Total Special Construction
|
$ -
|
||||||
14
|
CONVEYING SYSTEMS
|
||||||
ELEVATORS
|
$ 366,000
|
||||||
MRL Passenger Elevators
|
1
|
LS
|
$ 360,000
|
$ 360,000
|
Based on Xxxx Elevator
|
||
Temporary Cab Protection and Use
|
1
|
LS
|
$ 6,000
|
$ 6,000
|
|||
Total Conveying Systems
|
$ 366,000
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
15
|
MECHANICAL SYSTEMS
|
||||||
MECHANICAL SYSTEMS
|
$ 8,296,900
|
||||||
HVAC and Plumbing Systems
|
1
|
LS
|
$ 8,070,000
|
$ 8,070,000
|
|||
Provide Tower Tech Cooling Tower in Lieu of EVAPCO
|
1
|
LS
|
$ 42,000
|
$ 42,000
|
|||
Per VE OB-5, Reduce extra features on Custom Air Handling Units. (Eliminate Factory Leak Test - maintain Field Leak Test, Utilize 0.100" Aluminum Plate Flooring with spray foam insulation in lieu of 0.125", Remove subfloor as not needed with spray foam insulation.)
|
1
|
LS
|
$ (40,000)
|
$ (40,000)
|
|||
Per VE OB-6A, Change non-ice making chiller to XxXxxx for regular service
|
1
|
LS
|
$ (20,000)
|
$ (20,000)
|
|||
Addendum #2 Mechanical Changes
|
1
|
LS
|
$ 132,600
|
$ 132,600
|
|||
York Chiller - Supply Differential Pressue Switch in Lieu of Flow Switch
|
1
|
AL
|
$ 1,200
|
$ 1,200
|
|||
York Chiller - Fully enclose each compressor with acoustic sound blankets
|
1
|
AL
|
$ 5,600
|
$ 5,600
|
|||
XxXxxx Chiller - Add Double Insulation (1.5" in lieu of 3/4")
|
1
|
AL
|
$ 2,200
|
$ 2,200
|
|||
XxXxxx Chiller - Add 2 year parts & Labor Warraty for Entire Unit in lieu of five years on Compressor
|
1
|
AL
|
$ 5,200
|
$ 5,200
|
|||
XxXxxx Chiller - Add Marine Water Boxes for both the evaporator and condenser in lieu of epoxy coating the inside surfaces of water boxes and tube sheets
|
1
|
AL
|
$ 1,900
|
$ 1,900
|
|||
Underslab Coordination Drawings and Sleeving
|
1
|
LS
|
$ 30,000
|
$ 30,000
|
No Pipe installation included.
|
||
Start Up & Commissioning Support
|
1
|
LS
|
$ 20,000
|
$ 20,000
|
|||
Seismic Requirements
|
1
|
LS
|
NIC
|
$ -
|
Assumed Not Required.
|
||
Temporary Mechanical & Filter Maintenance
|
1
|
LS
|
$ 21,200
|
$ 21,200
|
LEED IEQ.
|
||
Mechanical Coordination Issues
|
1
|
LS
|
$ 25,000
|
$ 25,000
|
|||
FIRE PROTECTION
|
$ 396,400
|
||||||
Sprinkler Systems
|
1
|
LS
|
$ 421,400
|
$ 421,400
|
Includes FM-200 System.
|
||
Delete PRVs for sprinkler system as they are not required for code compliant sprinkler system.
|
1
|
LS
|
$ (25,000)
|
$ (25,000)
|
|||
GEOTHERMAL XXXXX
|
$ 326,300
|
||||||
Geothermal Xxxxx
|
1
|
LS
|
$ 305,000
|
$ 305,000
|
|||
Trench Rock Allowance
|
1
|
AL
|
$ 18,000
|
$ 18,000
|
|||
Mechanical Coordination Issues
|
1
|
LS
|
$ 3,300
|
$ 3,300
|
|||
Total Mechanical Systems
|
$ 9,019,600
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
5/21/2010
16
|
ELECTRICAL SYSTEMS
|
||||||
ELECTRICAL SYSTEMS
|
$ 5,113,150
|
||||||
Electrical Systems
|
1
|
LS
|
$ 4,840,000
|
$ 4,840,000
|
|||
Per VE OB-19, Defer 12 month Service Maintenance Contract with Load Bank Test to Owner O&M budget.
|
1
|
LS
|
$ (8,450)
|
$ (8,450)
|
|||
Underslab Coordination Drawings and Sleeving
|
1
|
LS
|
$ 18,000
|
$ 18,000
|
No Pipe installation included.
|
||
Addendum #2 Electrical Changes
|
1
|
LS
|
$ 69,800
|
$ 69,800
|
|||
Provide additional electronic metering of each overcurrent device for panels EDP1B and EDP1C. Added Note 15 on E-500. This is metering each subpannel
|
1
|
AL
|
$ 21,000
|
$ 21,000
|
|||
Upsize Generator Fuel Tank
|
1
|
AL
|
$ 95,000
|
$ 95,000
|
|||
Potential Changes to Dimming System per Design Coordination Meeting
|
1
|
AL
|
$ 25,000
|
$ 25,000
|
|||
Miscellaneous Equipment Connections
|
1
|
LS
|
$ 7,800
|
$ 7,800
|
Un-circuited Equipment.
|
||
Feeder & Xxxx Coordination
|
1
|
LS
|
$ -
|
$ -
|
Feeder Issues.
|
||
Microturbine Coordination
|
1
|
LS
|
$ -
|
$ -
|
Microturbine Components.
|
||
Lighting, Dimming & Daylighting Coordination
|
1
|
LS
|
$ 10,000
|
$ 10,000
|
Architecture vs. Electrical Documents, Dimming Issues.
|
||
Additional Site Security Conduit Requirements
|
1
|
LS
|
$ 15,000
|
$ 15,000
|
Security vs. Electrical Documents.
|
||
Additional Raceway Requirements
|
1
|
LS
|
$ 10,000
|
$ 10,000
|
Interior A/V, Tele/Data, Security Drawings vs. Electrical Documents.
|
||
Fire Alarm Coordination / Added Devices
|
1
|
LS
|
$ 10,000
|
$ 10,000
|
Missing FA Devices.
|
||
Seismic Requirements
|
1
|
LS
|
NIC
|
Assumed Not Required.
|
|||
Primary Ductbank & Feeders
|
1
|
LS
|
$ -
|
$ -
|
By Dominion Power.
|
||
Secondary Feeders
|
1
|
LS
|
$ -
|
$ -
|
By Dominion Power.
|
||
Pad-mounted Transformer
|
1
|
LS
|
$ -
|
$ -
|
By Dominion Power.
|
||
STORAGE FACILITY
|
$ 60,000
|
||||||
Provide PV Panels and Electric at the Storage Facility
|
1
|
AL
|
$ 60,000
|
$ 60,000
|
|||
TELE/DATA & CATV CABLING
|
$ -
|
||||||
Tele/Data/Cable TV Cabling & Equipment
|
1
|
N/A
|
$ -
|
$ -
|
By Owner
|
||
TEMPORARY SERVICE
|
$ 224,000
|
||||||
Temporary Power Service
|
1
|
LS
|
$ 92,000
|
$ 92,000
|
Dominion Power Service
|
||
Temporary Power Charges
|
1
|
LS
|
$ 95,000
|
$ 95,000
|
Power Xxxx.
|
||
Temporary Power & Lighting
|
1
|
LS
|
$ 37,000
|
$ 37,000
|
|||
Total Electrical Systems
|
$ 5,397,150
|
||||||
NRUCFC Xxxxxxxxxxxx Xxxxx 0 Building Detail
EXHIBIT E
SCOPE OF WORK
May 17, 2010
Provide general conditions, labor and materials associated with the construction of the new NRUCFC Corporate Headquarters Facility in accordance with the Contract Documents. The scope of work includes the following.
1.
|
Provide general construction of a three (3) story, 120,000 SF Corporate Office Building including full tenant fit-up.
|
2.
|
Provide site improvements including landscaping and hardscape not previously provided under the Phase I Site Development Contract.
|
3.
|
Provide site Storage Building and site Pavilion.
|
4.
|
Provide site lighting and site conduit.
|
5.
|
Provide coordination support for the Owner's Signage, Security, Audio-Visual, TelelData and Computer Room Equipment.
|
6.
|
Provide documentation for Contractor-controlled LEED credits and assist the Owner in pursuing LEED Certification.
|
7.
|
Provide pre-functional testing and start-up of building systems. Provide support to Owner's Commissioning Agent for final Building Commissioning. Provide training and turnover of building systems to Owner personnel.
|
8.
|
See Exhibit B "Assumptions and Clarifications to Amendment No. 1" for additional clarifications to the scope of work.
|
EXHIBIT F
SCHEDULE
See Attached Project Schedule Dated May 17, 2010