JUPITER GAS GATHERING AGREEMENT
Exhibit 10.24(b)
AMENDMENT NO. 1
TO
This Amendment No. 1 to the Jupiter Gas Gathering Agreement (this “Amendment”) is made and entered into as of December 17, 2014, by and between EQT Production Company (“Producer”) and EQT Energy, LLC (collectively with Producer, “Shipper”), on the one hand, and EQM Gathering OPCO, LLC (“Gatherer”), on the other hand. Producer, Shipper and Gatherer are each referred to herein as a “Party” and collectively as the “Parties”.
WHEREAS, the Parties made and entered into that certain Jupiter Gas Gathering Agreement dated May 1, 2014 (the “Agreement”) pursuant to which, among other provisions, Shipper requested that Gatherer provide the gathering of natural gas on behalf of Shipper by receiving quantities of natural gas and redelivering it to or for Shipper's account; and
WHEREAS, the Parties intend to amend the Agreement, upon the terms and subject to the conditions set forth herein.
NOW, THEREFORE, for good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, and intending to be legally bound, the Parties hereby agree as follows:
1. Definitions. All capitalized terms used but not otherwise defined or amended herein shall have the meanings ascribed to them in the Agreement.
2. Amendments.
a. Exhibit A attached to the Agreement is hereby amended to add the following
Receipt Point:
Receipt Point(s) | Receipt Point MDQ MMcf/Day | Zone | Zone MDQ MMcf/Day |
Alpha | 80 | Zone3 | 370 |
[REMAINDER OF PAGE INTENTIONALLY BLANK]
b. Section III(A)(l) of Exhibit F attached to the Agreement is hereby amended to add or make a revision to the following meters to the table included therein:
Meter ID | Meter Name | GPS Coordinates | MA OP | MinDQ * (Mcf / Day) | MaxDQ (Mcf / Day) |
17042 | Xxxxx | 39.969918, -80.110996 | 1440 | 1,670 | 78,500 |
00000 | Xxxxxxxx0 | 39.948602, -80.096748 | 720 | 680 | 45,900 |
M5220213 | Xxxxxx 1 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220220 | Xxxxxx 2 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220221 | Xxxxxx 3 | 39.94523, -80.23994 | 720 | 726 | 26,240 |
M5224083 | Xxxxxxxx | 39.954037, -80.065039 | 1440 | 1,227 | 44,838 |
M5224627 | Alpha 1 | 39.960097, -80.130604 | 1440 | 1,227 | 44,838 |
M5224714 | Alpha 2 | 39.960097, -80.130604 | 1440 | 1,227 | 44,838 |
* Calculated @ minimum NOP with minimum Beta plate when applicable
c. | Section III(A)(2) of Exhibit F attached to the Agreement is hereby amended to add a responsibilities table for each of the meters added pursuant to Section 2(b) of this Amendment, which establishes the design, construction, operation, maintenance and cost responsibility for each meter. Copies of such responsibilities table for each of the meters are attached hereto and incorporated herein by reference. |
3. Effect of Amendment. The Agreement, as amended hereby, shall remain in full force and effect, and all terms hereof are hereby ratified and confirmed by the Parties.
4. Further Actions. The Parties agree to execute such other documents and take such further actions necessary to effectuate this Amendment.
5. Counterparts. This Amendment may be executed in any number of counterparts, each of which shall be deemed an original and all of which together shall constitute one and the same agreement. It is agreed by the Parties that facsimile signature pages signed by the Parties shall be binding to the same extent as original signature pages.
6. Entire Agreement. This Amendment is the entire agreement between the Parties concerning the subject matter hereof and neither Party shall be bound by representations except as set forth in this Amendment.
7. Amendments. This Amendment may not be modified or amended except by a written agreement signed by the Parties.
2
IN WITNESS WHEREOF, the Parties have executed this Amendment as of the date first written above.
EQT PRODUCTION COMPANY EQM GATHERING OPCO, LLC
By: /s/ Xxxxx Xxxxxxxxx By: /s/ Xxxxxx X. Xxxxxx
Name: Xxxxx Xxxxxxxxx Name: Xxxxxx X. Xxxxxx
Title: EVP Title: Vice President
EQT ENERGY, LLC
By: /s/ Xxxxxx X. Xxxxxxx
Name: Xxxxxx X. Xxxxxxx
Title: EVP, Commercial
3
Attachment to Amendment No. 1 to Jupiter Gas Gathering Agreement dated December 17, 2014
Xxxxx, 17042 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap Value | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 6 Inch Tee & Valve ANSI 600 |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | 6” Coated |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Test Station – inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station – outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filler Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | EQT-Approved Peco Cyclotube |
Liquid Level Shutoff | No | Auto Shutoff | |||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 8 Inch Orifice Metter ANSI 600 |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 8 Inch ANSI 600 |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Xxxxxx 107 |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Radio |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar & Battery |
Building – Gas Chromatograph | No | ||||||
Building – Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
4
Attachment to Amendment No. 1 to Jupiter Gas Gathering Agreement dated December 17, 2014
Xxxxxxxx 1, 17043 Xxxxxxxx 2, 17115 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap Value | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | One 6-inch tee & valve ANSI 300; one 8-inch tee & valve ANSI 300 |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | 6” coated |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Two 6” lines, one to existing 6” tee and other to 8” tee |
Test Station – inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station – outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filler Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | |
Liquid Level Shutoff | No | Auto Shutoff | |||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Two 6-inch orifice meters ANSI 300 (existing) |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 6 Inch ANSI 300 (existing) |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Xxxxxx 107 (existing) |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 4” V-200 with 4195 Wizard Controller (existing) |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 4” V-200 with 4195 Wizard Controller (existing) |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | 4” ANSI 300 |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Radio |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar & Battery |
Building – Gas Chromatograph | No | ||||||
Building – Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
5
Attachment to Amendment No. 1 to Jupiter Gas Gathering Agreement dated December 17, 0000
Xxxxxx 1, M5220213 Xxxxxx 2, M5220220 Xxxxxx 3, M5220221 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | One 8” Tap, Two 12” Taps and Valves ANSI 300 |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | 16” Coated Pipe; 20” buried header |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 16” Coated Pipe; 20” buried header |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | EQT Approved |
Liquid Level Shutoff | No | ||||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Two 8-inch, One 6-inch Orifice Meter Runs |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 8-inch and 6-inch for above |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 3 Eagle /1 RTU w/ Radio |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | None if using buckling pin, else Xxxxxx V-200s and 4195 Wizard Controllers |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Slam-shut buckling pin preferred, or Xxxxxx V-200s and 4195 Wizard Controllers |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Manual Valve |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | In lieu of flow control valve, OPP is acceptable |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | Two 8-inch, one 6-inch |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Radio |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar w/Batteries |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
6
Attachment to Amendment No. 1 to Jupiter Gas Gathering Agreement dated December 17, 2014
Xxxxxxxx 1, 5100057 Xxxxxxxx 2, M5224083 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 8” Tap |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | Existing |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Existing |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | Xxxxxxxx Filter plus EQT Approved Peco Cyclotube |
Liquid Level Shutoff | No | 16” Barrel | |||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Existing 6” orifice plus 8” orifice |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Existing 6” valves plus 8” valves |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Eagle/1 RTU (for each meter) |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Primary and Monitor control valves are req'd UNLESS a Rupture Pin Valve is installed. Existing 4” CV/OPP |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Rupture Pin Valve or Primary and Monitor Control Valve, Existing 4” OPP |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Manual valve at header |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | 6” and 8” |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Radio or Cell |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar & Battery |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
7
Attachment to Amendment No. 1 to Jupiter Gas Gathering Agreement dated December 17, 2014
Alpha 1, M5224627 Alpha 2, M5224714 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 10” hot tap |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | 10” minimum |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 10” minimum |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | EQT Approved Peco Cyclotube |
Liquid Level Shutoff | No | ||||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Two 8” orifice |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Valves for 8” meter skid |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Eagle/1 RTU (for each meter) |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Primary and Monitor control valves are req'd UNLESS a Rupture Pin Valve is installed |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Rupture Pin Valve or Primary and Monitor Control Valve |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Manual valve at header |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | In lieu of flow control valve, OPP is acceptable |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | For each 8” meter skid |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Cell Modem |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar & Battery |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
8