AMENDMENT NO. 5 TO JUPITER GAS GATHERING AGREEMENT
Exhibit 10.20(f)
Portions of this Exhibit have been redacted pursuant to a request for confidential treatment under Rule 24b-2 of the General Rules and Regulations under the Securities Exchange Act. Omitted information marked “[***]” in this Exhibit has been filed with the Securities and Exchange Commission together with such request for confidential treatment.
Execution Version
This Amendment No. 5 to the Jupiter Gas Gathering Agreement (this “Amendment”) is made and entered into as of October 1, 2017, by and between EQT Production Company (“Producer”) and EQT Energy, LLC (collectively with Producer, “Shipper”), on the one hand, and EQM Gathering OPCO, LLC (“Gatherer”), on the other hand. Producer, Shipper and Gatherer are each referred to herein as a “Party” and collectively as the “Parties”.
WHEREAS, the Parties made and entered into that certain Jupiter Gas Gathering Agreement, the “Agreement”, dated May 1, 2014 (as amended by that certain Amendment No. 1 to Jupiter Gas Gathering Agreement, dated December 17, 2014, that certain Amendment No. 2 to Jupiter Gas Gathering Agreement, dated October 26, 2015, that certain Amendment No. 3 to Jupiter Gas Gathering Agreement, dated August 1, 2016,and that certain Amendment No. 4 to Jupiter Gas Gathering Agreement, dated June 1, 2017), pursuant to which, among other provisions, Shipper requested that Gatherer provide gathering services to Shipper by receiving quantities of Gas from Shipper at the Receipt Points and redelivering such Gas to or for Shipper’s account at the Delivery Points; and
WHEREAS, the Parties intend to amend Exhibit A and Section II (Table of Incremental Capital Fees) of Exhibit B-2 of the Agreement upon the terms and subject to the conditions set forth herein.
NOW, THEREFORE, for good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, and intending to be legally bound, the Parties hereby agree as follows:
1.Definitions. All capitalized terms used but not otherwise defined or amended herein shall have the meanings ascribed to them in the Agreement.
2.Amendments.
a. | Exhibit A attached to the Agreement is hereby deleted in its entirety and replaced with the revised Exhibit A attached hereto as Attachment 1. |
b. | Section II (Table of Incremental Capital Fees) of Exhibit B-2 attached to the Agreement is hereby deleted in its entirety and replaced with the revised Section II (Table of Incremental Capital Fees) attached hereto as Attachment 2. In accordance with Section 4.2(b) of the Agreement, the Parties have agreed to an Incremental Capital Project in respect of the new Receipt Point identified in Section II of Exhibit B-2 (the “West Run – Hopewell Ridge Receipt Point”), which is separate from the |
Amendment No. 5
West Run Receipt Point in Zone 1 identified on the revised Exhibit A attached hereto as Attachment 1. The Parties further agree that:
i. | this Incremental Capital Project shall not trigger an increase in the Compression MDQ or the Contract MDQ or an extension of any Term under the Agreement; |
ii. the Incremental Capital Fee shall be a negotiated volumetric rate of [***] (in lieu of a Monthly reservation rate) for all Gas delivered by Shipper and received by Gatherer at West Run – Hopewell Ridge Receipt Point, which Receipt Point will not be subject to the Target Receipt Point Pressure, and any Gas delivered to such Receipt Point shall not be considered in calculating the Compression MDQ, the Contract MDQ or the Overrun Fees under the Agreement;
iii. the Incremental Capital Fee shall apply to Gas delivered to the West Run – Hopewell Ridge Receipt Point beginning [***] and until [***], and thereafter shall apply to such Gas until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination.
iv. Shipper shall not install wellhead or other compression upstream of the West Run – Hopewell Ridge Receipt point without prior written consent from Gatherer.
c. | In Section III (Site Specific Data and Facility Responsibility Matrix) of Exhibit F attached to the Agreement: |
i. | the pages including Section III.A.1 (Receipt Point Interconnect Data) is hereby deleted in their entirety and replaced with the revised pages including Section III.A.1 (Receipt Point Interconnect Data) attached hereto as Attachment 3; and |
ii. Section III.A.2 (Responsibility for Interconnect Facility Equipment) is hereby amended to include the additional Interconnect Facilities responsibilities tables for the meters identified as set forth below, which tables (1) establish the design, construction, operation, maintenance and cost responsibility for each such meter and (2) are attached hereto as Attachment 3.
2
Amendment No. 5
M5277181 M5274373 M5258883
M5274165 M5274166 M5274167
M5256116 M5256117 M5256118
M5272524 M5291357
3.Effect of Amendment. The Agreement, as amended hereby, shall remain in full force and effect, and all terms hereof are hereby ratified and confirmed by the Parties.
4.Further Actions. The Parties agree to execute such other documents and take such further actions necessary to effectuate this Amendment.
5.Counterparts. This Amendment may be executed in any number of counterparts, each of which shall be deemed an original and all of which together shall constitute one and the same agreement. It is agreed by the Parties that facsimile signature pages signed by the Parties shall be binding to the same extent as original signature pages.
6.Entire Agreement. This Amendment is the entire agreement between the Parties concerning the subject matter hereof and neither Party shall be bound by representations except as set forth in this Amendment.
7.Amendments. This Amendment may not be modified or amended except by a written agreement signed by the Parties.
[The remainder of this page intentionally left blank.]
3
Amendment No. 5
IN WITNESS WHEREOF, the Parties have executed this Amendment as of the date first written above.
EQT PRODUCTION COMPANY | EQM GATHERING OPCO, LLC |
By: /s/ Xxxxx Schlosser__________ | By: /s/ Xxxxxxxx X. Ashcroft_______ |
Name: Xxxxx Schlosser____________ | Name: Xxxxxxxx X. Ashcroft__________ |
Title: President__________________ | Title: President___________________ |
EQT ENERGY, LLC | |
By: /s/ Xxxxxx X. Jenkins_________ | |
Name: Xxxxxx X. Jenkins____________ | |
Title: President____________________ |
4
Amendment Xx. 0
XXXXXXXXXX 0
Xxxxxxxxx Xx. 0
EXHIBIT A
RECEIPT POINTS, DELIVERY POINTS,
CONTRACT MDQ AND COMPRESSION MDQ
CONTRACT MDQ AND COMPRESSION MDQ
Receipt Point(s) | Receipt Point MDQ MMcf/Day | Zone | Zone MDQ MMcf/Day |
West Run | 80 | Xxxx 0 | 000 |
Xxxxxxx | 00 | Xxxx 0 | 000 |
Xxxxx Xxxx | 00 | Xxxx 1 | 300 |
Xxxxxx | 100 | Xxxx 0 | 000 |
Xxxxxx X | 00 | Xxxx 1 | 300 |
Xxxxx | 40 | Xxxx 0 | 000 |
Xxxxxxxx | 00 | Xxxx 1 | 000 |
Xxxxxx Xxx | 30 | Xxxx 0 | 000 |
Xxxxxxxxx Xxxxx | 00 | Xxxx 1 | 300 |
Xxxxxxxxx | 120 | Xxxx 0 | 000 |
Xxxxxxxx | 000 | Xxxx 2 | 370 |
Xxxxxx | 140 | Xxxx 0 | 000 |
Xxx Xxx | 00 | Xxxx 2 | 370 |
Xxxxxx | 45 | Zone 2 | 370 |
Amity | 15 | Xxxx 0 | 000 |
Xxxxxx Xxxx | 000 | Xxxx 2 | 370 |
Xxxxxxx | 65 | Xxxx 0 | 000 |
Xxxxxx | 00 | Xxxx 2 | 370 |
Xxxxxx | 55 | Zone 2 | 370 |
Xxxxxxx | 9 | Xxxx 0 | 000 |
Xxxxxx | 00 | Xxxx 2 | 370 |
Xxxxxxx | 37.5 | Xxxx 0 | 000 |
X&X | 37.5 | Xxxx 0 | 000 |
Xxxxx | 000 | Xxxx 3 | 370 |
Xxxxxxxxxx | 35 | Xxxx 0 | 000 |
Xxxxx | 00 | Xxxx 3 | 370 |
Beazer | 50 | Zone 3 | 370 |
Xxxxxxxxx | 00 | Xxxx 3 | 370 |
Minor | 60 | Xxxx 0 | 000 |
Xxxxxxxx | 00 | Xxxx 3 | 370 |
XxXxxxxx | 20 | Xxxx 0 | 000 |
Xxxxxxxx | 00 | Xxxx 3 | 370 |
Xxxxxxxx | 25 | Xxxx 0 | 000 |
Xxxxxxxxxxxx | 2 | Xxxx 0 | 000 |
Xxxxx | 00 | Xxxx 3 | 370 |
Xxxxxx | 000 | Xxxx 3 | 000 |
Xxxx Xxx - Xxxxxxxx Xxxxx | X/X | X/X | X/X |
Exhibit A
Page 1
Page 1
Amendment No. 5
EXHIBIT A (Continued)
RECEIPT POINTS, DELIVERY POINTS,
CONTRACT MDQ AND COMPRESSION MDQ
CONTRACT MDQ AND COMPRESSION MDQ
Delivery Point(s) | Location |
Xxxxxx | Equitrans X-000 |
Xxxxx | Xxxxxxxxx X-000 |
Jupiter | Equitrans H-148 |
Callisto | Equitrans X-000 |
Xxxxxxxx Xxxxx | Xxxxxxxxx X-000 |
Pipers Ridge | Equitrans X-00 |
Xxxxxx | Xxxxxxxxx X-000 |
Io | Equitrans H-148 and M-78 |
Drip Liquids Delivery Point(s) | Location |
Not applicable |
Contract MDQ: | 792,000 Dth / Day |
Compression MDQ: | 792,000 Dth / Day |
Exhibit A
Page 2
Amendment Xx. 0
XXXXXXXXXX 0
Xxxxxxxxx Xx. 0
XX. Table of Incremental Capital Fees
Incremental Capital Project | Contract MDQ | Incremental Capital Fee | In-Service Date | Applicable Expansion Term |
West Run – Hopewell Ridge Receipt Point (5100053) | [***] | Volumetric fee of [***] | [***] | Until [***], and thereafter until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
Exhibit B-2
Page 2
Amendment Xx. 0
XXXXXXXXXX 0
Xxxxxxxxx Xx. 0
XXX. SITE SPECIFIC DATA AND FACILITY RESPONSIBILITY MATRIX
A. | In addition to the minimum design specification and operating parameters set forth in the Engineering and Technical Design Standards, the following specifications shall be followed: |
1. | Receipt Point Interconnect Data: The table below provides for the list of meters covered under this Agreement which may be updated from time to time in accordance with the terms and conditions of this Agreement. Each meter in the Receipt Point Interconnect table shall conform to the specifications listed in the table applicable to such meter under Section III(A)(2). |
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
17019 | Xxxxxx B | 39.95597, -80.26908 | 720 | 1,220 | 78,500 |
11798 | Xxxxxxx 1 | 39.94097, -80.326422 | 720 | 320 | 19,600 |
17018 | Xxxxxxx 2 | 39.94097, -80.25422 | 720 | 320 | 19,600 |
11796 | XxXxxxxx | 39.9836, -80.1209 | 720 | 710 | 45,900 |
M5256116 | XxXxxxxx 2 MM - 1 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
M5256117 | XxXxxxxx 2 MM - 2 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
M5256118 | XxXxxxxx 2 MM - 3 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
17042 | Xxxxx 1 | 39.969918, -80.110996 | 1,440 | 1,670 | 78,500 |
M5224755 | Xxxxx 2 | 39.96643, -80.1116 | 1440 | 1,227 | 64,353 |
17035 | Xxxxxxxxxx | 39.974133, -80.096991 | 720 | 650 | 45,900 |
17022 | Xxxxxxx 1 | 39.979817, -80.072114 | 720 | 680 | 45,900 |
18156 | Xxxxxxx 2 | 39.97799, -80.07021 | 720 | 720 | 45,900 |
17043 | Xxxxxxxx 1 | 39.948602, -80.096748 | 720 | 680 | 45,900 |
17115 | Xxxxxxxx 2 | 39.948602, -80.096748 | 720 | 680 | 45,900 |
00000 | Xxxxxxxxxxxx | 39.96395, -80.100731 | 720 | 320 | 19,600 |
17044 | Xxxxxx 1 | 39.946228, -80.240644 | 720 | 680 | 45,900 |
5100003 | Xxxxxx 2 | 39.946228, -80.240644 | 720 | 680 | 45,900 |
17037 | Xxxxxxxx | 39.933614, -80.293665 | 1,400 | 1,150 | 115,300 |
18155 | Xxxxxx B | 39.934471, -80.318565 | 1,400 | 1,600 | 67,500 |
Exhibit F
Page 4
Amendment No. 5
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
5100014 | Xxxxx’x Run 1 | 39.93239, -80.32793 | 1,400 | 2,700 | 115,300 |
5100015 | Xxxxx’x Run 2 | 39.93239, -80.32793 | 1,400 | 2,700 | 115,300 |
M5225755 | Xxxxx'x Run 3 | 39.93237, -80.32812 | 1,400 | 1,227 | 64,353 |
5100065 | Xxxxx XX B Run | 39.92772, -80.33715 | 1,400 | 2,700 | 115,300 |
M5277181 | Xxxxx XX Run 2 | 39.92763, -80.33740 | 1440 | 1,150 | 28,800 |
0000000 | Xxxx Xxx (NIJUS25) | 39.913752, -80.303533 | 1,400 | 2,700 | 115,300 |
0000000 | Xxxx Xxx – Xxxxxxxx Xxxxx | 39.91312, -80.30316 | 1,400 | 2,511 | 87,994 |
5100055 | Xxxxxxxxx 1 | 39.936506 , -80.310759 | 1,400 | 2,700 | 115,300 |
5100063 | Xxxxxxxxx 2 | 39.936506 , -80.310759 | 1,400 | 2,700 | 115,300 |
5100057 | Xxxxxxxx 1 | 39.954037, -80.065039 | 720 | 720 | 45,900 |
M5224083 | Xxxxxxxx 2 | 39.954037, -80.065039 | 720 | 1,227 | 44,838 |
5100018 | Xxxxxx 1 | 39.90734, -80.28209 | 720 | 2,630 | 78,500 |
5100019 | Xxxxxx 2 | 39.90734, -80.28209 | 720 | 2,630 | 78,500 |
5100064 | Xxxxxx 3 | 39.90734, -80.28209 | 720 | 2,630 | 45,900 |
M5213961 | Big Sky 1 | 39.99805556,-80.20277 | 720 | 1,750 | 78,500 |
M5213962 | Big Sky 2 | 39.99805556, -80.20277 | 720 | 1,750 | 78,500 |
M5213963 | Big Sky 3 | 39.99805556, -80.20277 | 720 | 1,030 | 45,900 |
M5220213 | Petit 1 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220220 | Petit 2 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220221 | Petit 3 | 39.94523, -80.23994 | 720 | 726 | 26,240 |
M5248813 | Petit 4 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5248814 | Petit 5 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5248816 | Petit 6 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5254623 | Petit 7 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5224627 | Alpha 1 | 39.960097, -80.130604 | 720 | 1,227 | 44,838 |
M5224714 | Alpha 2 | 39.960097, -80.130604 | 720 | 1,227 | 44,838 |
M5274373 | Alpha 3 | 39.960097, -80.130604 | 720 | 1,950 | 35,500 |
M5234610 | Xxxxxxxx Run 1 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
Exhibit F
Page 5
Amendment No. 5
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
M5234612 | Xxxxxxxx Run 2 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5234613 | Xxxxxxxx Run 3 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5235813 | Xxxxxxxx Run 4 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5234486 | Xxxxxxx Run 1 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
M5234487 | Xxxxxxx Run 2 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
M5234488 | Xxxxxxx Run 3 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
00000 | Xxxxx | 40.0308, -80.15266 | 720 | 726 | 37,660 |
M5219031 | Xxxxxxx 1 | 39.991551, -80.194235 | 720 | 726 | 37,660 |
M5219033 | Xxxxxxx 2 | 39.991551, -80.194235 | 720 | 1,227 | 64,353 |
M5258883 | Xxxxxxx Gathering MM - Run 3 | 39.991551, -80.194235 | 720 | 1,950 | 35,500 |
00000 | Xxxxxx 590004 | 39.93929, -80.26466 | 720 | 356 | 16,118 |
33341 | ROG46H1 | 39.94097, -80.26422 | 720 | 356 | 16,118 |
M5210064 | Xxxxx 1 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5210065 | Xxxxx 2 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5210066 | Xxxxx 3 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5234259 | Xxxxxxxxx 1 | 39.99347, -80.06271 | 1440 | 1,227 | 64,353 |
M5234260 | Xxxxxxxxx 2 | 39.99347, -80.06271 | 1440 | 1,227 | 64,353 |
M5226733 | Beazer 1 | 39.92417, -80.10866 | 1440 | 1,227 | 64,353 |
M5226735 | Beazer 2 | 39.92417, -80.10866 | 1440 | 1,227 | 64,353 |
M5249530 | Beazer 3 | 39.92417, -80.10866 | 1440 | 1,556 | 57,163 |
M5238116 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5238117 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5248049 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5241305 | Xxxxxx Farm 1 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
M5241307 | Xxxxxx Farm 2 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
M5241308 | Xxxxxx Farm 3 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
Exhibit F
Page 6
Amendment No. 5
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
M5274165 | Green Hill - Meter 1 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5274166 | Green Hill - Meter 2 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5274167 | Green Hill - Meter 3 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5272524 | Xxxxxx | 39.95349, -80.19008 | 720 | 1,800 | 49,000 |
X0000000 | Xxxxxx Xxx X | 39.95349, -80.19008 | 720 | 1,800 | 49,000 |
* Calculated @ minimum NOP with minimum Beta plate when applicable
Responsibility for Interconnect Facility Equipment. Each of the following tables establish, for the meter specified in the cell located in the first row of the first column of such table (or, if no meter is specified in such cell, then for each meter not specified in any of the other tables included below) the design, construction, operation, maintenance and cost responsibility for certain aspects of the Interconnect Facilities. All of the following design responsibilities designated as Producer’s responsibility shall be incorporated into the design and construction of the Interconnect Facilities
Exhibit F
Page 7
Amendment No. 5
EXHIBIT F (Section III.A.2.)
Responsibility for Interconnect Facility Equipment
XxXxxxxx 2 MM – 1, M5256116 McMillen 2 MM – 2, M5256117 McMillen 2 MM – 3, M5256118 STATION EQUIPMENT | REQUIRED | DESIGN SPECIFICATIONS | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
EQT Pipeline-Tap & Valve | Yes | Company | Company | Company | Company | Company |
Inlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Station & Outlet Piping | Yes | Company | Customer | Customer | Company | Customer |
Test Station - inlet piping | No | |||||
Test Station - outlet piping | Yes | Company | Company | Company | Company | Company |
Corrosion coupon | Yes | Company | Company | Company | Company | Company |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Company | Customer | Customer | Customer | Customer |
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Company | Customer | Customer | Company | Customer |
Meter & Flow Control Risers, Valves, etc… | Yes | Company | Customer | Customer | Company | Customer |
Electronic Measurement & Telecomm Hardware | Yes | Company | Customer | Customer | Company | Customer |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Continuous Sampler | No | |||||
H2O Dew Point Analyzer | No | |||||
Oxygen Analyzer | No | |||||
H2S Monitor | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Primary Pressure Control | No | |||||
Overpressure Device | Yes | Company | Customer | Customer | Company | Customer |
Station Isolation Valve | Yes | Company | Customer | Customer | Company | Customer |
Flow Control Valve | No | |||||
Heat | No | |||||
Check Valve | Yes | Company | Customer | Customer | Company | Customer |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication Service(s) | Yes | Company | Customer | Customer | Company | Customer |
Electrical Service | Yes | Company | Customer | Customer | Company | Customer |
Building - Gas Chromatograph | No | |||||
Building - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Company | Customer | Customer | Company | Customer |
Air Permit | No |
Amendment No. 5
Xxxxx XX B Run, 5100065 Moore MM Run 2, M5277181 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 12” Tee |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 12” |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | LLSO - 16" Barrel & Xxxxxxxx Filter |
Liquid Level Shutoff | No | ||||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | (2) 8” Orifice |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Eagle/1 RTU (ea meter) |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” CV/OPP |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” OPP |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 8” |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” CV (same devices as Primary Pressure. Control.) |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | 2 X 8” |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Radio or Cell |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
Amendment No. 5
Alpha 1, M5224627 Alpha 2, M5224714 Alpha 3, M5274373 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 10” hot tap |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | 10” minimum |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 10” minimum |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | EQT Approved Peco Cyclotube |
Liquid Level Shutoff | No | ||||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Two 8” orifice |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Valves for 8” meter skid |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Eagle/1 RTU (for each meter) |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | ||||||
H2S Monitor | No | ||||||
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Primary and Monitor control valves are req'd UNLESS a Rupture Pin Valve is installed |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Rupture Pin Valve or Primary and Monitor Control Valve |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Manual valve at header |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | In lieu of flow control valve, OPP is acceptable |
Heat | No | ||||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | For each 8” meter skid |
ODORIZATION | |||||||
Odorizer & Controls | No | ||||||
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | Cell Modem |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar & Battery |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | ||||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | No |
Amendment No. 5
Xxxxxxx Gathering MM – Run 1, M5219031 Xxxxxxx Gathering MM – Run 2, M5219033 Shipman Gathering MM – Run 3, M5258883 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer |
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Continuous Sampler | No | |||||
H2O Dew Point Analyzer | No | |||||
Oxygen Analyzer | No | |||||
H2S Monitor | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Heat | No | |||||
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Building - Gas Chromatograph | No | |||||
Building - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer |
Air Permit | No |
Amendment Xx. 0
Xxxxx Xxxx- Xxxxx 0, X0000000 Xxxxx Xxxx- Xxxxx 0, X0000000 Xxxxx Xxxx- Meter 3, M5274167 STATION EQUIPMENT | REQUIRED | DESIGN SPECIFICATIONS | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
EQT Pipeline-Tap & Valve | Yes | Company | Company | Company | Company | Company |
Inlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Station & Outlet Piping | Yes | Company | Customer | Customer | Company | Customer |
Test Station - inlet piping | Yes | Customer | Customer | Customer | Customer | Customer |
Test Station - outlet piping | Yes | Company | Company | Company | Company | Company |
Corrosion coupon | Yes | Company | Company | Company | Company | Company |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Company | Customer | Customer | Customer | Customer |
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Company | Customer | Customer | Company | Customer |
Meter & Flow Control Risers, Valves, etc… | Yes | Company | Customer | Customer | Company | Customer |
Electronic Measurement & Telecomm Hardware | Yes | Company | Customer | Customer | Company | Customer |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Continuous Sampler | No | |||||
H2O Dew Point Analyzer | No | |||||
Oxygen Analyzer | No | |||||
H2S Monitor | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Primary Pressure Control | Yes | Company | Customer | Customer | Company | Customer |
Overpressure Device | Yes | Company | Customer | Customer | Company | Customer |
Station Isolation Valve | Yes | Company | Customer | Customer | Company | Customer |
Flow Control Valve | No | |||||
Heat | No | |||||
Check Valve | Yes | Company | Customer | Customer | Company | Customer |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication Service(s) | Yes | Company | Customer | Customer | Company | Customer |
Electrical Service | Yes | Company | Customer | Customer | Company | Customer |
Building - Gas Chromatograph | No | |||||
Building - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Company | Customer | Customer | Company | Customer |
Air Permit | No |
Amendment No. 5
Xxxxxx, M5272524 Harris Run B, M5291357 STATION EQUIPMENT | REQUIRED | DESIGN SPECIFICATIONS | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
EQT Pipeline-Tap & Valve | Yes | Company | Company | Company | Company | Company |
Inlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Station & Outlet Piping | Yes | Company | Customer | Customer | Company | Customer |
Test Station - inlet piping | No | |||||
Test Station - outlet piping | Yes | Company | Company | Company | Company | Company |
Corrosion coupon | Yes | Company | Company | Company | Company | Company |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Company | Customer | Customer | Customer | Customer |
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Company | Customer | Customer | Company | Customer |
Meter & Flow Control Risers, Valves, etc… | Yes | Company | Customer | Customer | Company | Customer |
Electronic Measurement & Telecomm Hardware | Yes | Company | Customer | Customer | Company | Customer |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Continuous Sampler | No | |||||
H2O Dew Point Analyzer | No | |||||
Oxygen Analyzer | No | |||||
H2S Monitor | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Primary Pressure Control | No | |||||
Overpressure Device | Yes | Company | Customer | Customer | Company | Customer |
Station Isolation Valve | Yes | Company | Customer | Customer | Company | Customer |
Flow Control Valve | No | |||||
Heat | No | |||||
Check Valve | Yes | Company | Customer | Customer | Company | Customer |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication Service(s) | Yes | Company | Customer | Customer | Company | Customer |
Electrical Service | Yes | Company | Customer | Customer | Company | Customer |
Building - Gas Chromatograph | No | |||||
Building - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Company | Customer | Customer | Company | Customer |
Air Permit | No |