PACIFIC GAS AND ELECTRIC COMPANY ("PG&E") and WIND DEVELOPERS, INC. entered
into a Standard Offer No. 4 Power Purchase Agreement ("Agreement") executed by
Wind Developers, Inc. on December 31, 1984 and by PG&E on January 17, 1985, for
the 20,000 kW wind project located at the Rooney Ranch, Sections 21 and 28,
Township 2 South, Range 3 East, M.D.B. & M, in the Altamont Pass area of Alameda
County, California. On December 6, 1985, PG&E consented to an assignment of the
Agreement from Wind Developers, Inc. to Zond Systems, Inc. On December 6, 1985,
PG&E consented to an assignment of the Agreement from Zond Systems, Inc. to Zond
Windsystem Partners, Ltd. Series 85-C ("Seller").
The parties wish to complete Section (d) of Article 3 which specifies the
limit on the rate of delivery into the PG&E system and Sections F-2 and F-3 of
Appendix F which specify the point of delivery of Seller's power to PG&E and the
interconnection facilities for which the Seller is responsible.
1
THEREFORE, for the good and valuable consideration, the receipt and
sufficiency of which are hereby acknowledged, the Agreement is hereby amended as
follows:
1. Article 3, Section (d) shall read,
"To avoid exceeding the physical limitations of the interconnection
---------------
facilities, Seller shall limit the Facility's actual rate of delivery into the
---------- ----------
PG&E system to 20,000 kW."
2. Pursuant to Article 11, Exhibits F-2 and F-3 attached hereto and
incorporated herein shall be substituted for pages F-3 and F-4.
All other provisions of the Agreement remain unchanged.
IN WITNESS WHEREOF, the parties hereto have caused this Second Amendment to
be executed by their duly authorized representatives and effective as of the
last date set forth below.
ZOND WINDSYSTEM PARTNERS LTD., SERIES PACIFIC GAS AND ELECTRIC COMPANY
85-C, a California Limited Partnership
By its General Partner, ZOND
WINDSYSTEMS MANAGEMENT CORPORATION V.
By: /s/ Xxxxxxx Xxxxx By:
----------------------------------- -----------------------------
XXXXXXX XXXXX XXXXX X. ROSPUT
Title: President Title: Manager, Qualifying
Facilities Contracts
Date Signed: 9/19/88 Date Signed:
------------------------- --------------------
2
EXHIBIT F-2
[F-2: SKETCH OF POINT OF DELIVERY]
EXHIBIT F-3
INTERCONNECTION FACILITIES FOR WHICH SELLER IS RESPONSIBLE
Pursuant to this Special Facilities Agreement between Seller and PG&E, Seller is
responsible for the following:
1. 6,250 feet of No. 397 Aluminum Conductor
2. Transfer trips equipment
3. Telemetry equipment
4. Revenue metering (60 kV)
5. Herdlyn-Livermore 60 kV upgrade and right-of-way costs
F-4