Exhibit 10.1
PORTIONS OF THIS EXHIBIT HAVE BEEN OMITTED AND FILED SEPARATELY WITH THE
SECURITIES AND EXCHANGE COMMISSION. SUCH PORTIONS ARE DESIGNATED "[***]."
THIS FIXED POINT MICROWAVE SERVICES AGREEMENT is made and entered into
as of the 17th day of October, 1997 (the "EFFECTIVE DATE"), by and between
PathNet, Inc. ("PATHNET"), a Delaware corporation and Northern Border
Pipeline Company ("INCUMBENT"), a Texas partnership (collectively, the
"PARTIES" and each, a "PARTY").
W I T N E S S E T H:
WHEREAS, PathNet is engaged in the business of creating high capacity,
digital, microwave communications systems for purposes of marketing and selling
the excess long distance telecommunications capacity created by such systems;
WHEREAS, Incumbent is the owner and operator of an existing microwave
telecommunications system; and
WHEREAS, Incumbent desires to engage PathNet as, and PathNet desires to act
as, Incumbent's sole representative for the purpose of (i) installing, managing,
and operating a high capacity digital microwave system along Incumbent's
microwave paths and (ii) marketing and selling any Excess Capacity created by
such high capacity digital microwave system.
NOW, THEREFORE, in consideration of the mutual promises contained herein,
the Parties agree as follows:
SECTION 1. DEFINITIONS
1.1 DEFINITIONS: As used in this Agreement, the following terms
shall have the meanings indicated:
1.1.1 1/0 MULTIPLEXER: Any device that multiplexes capacity
between the DS-1 and the DS-0 levels.
1.1.2 1 X 1: A microwave radio configuration consisting of a
primary and a protect radio.
1.1.3 AFFILIATE: With respect to any Person, any other Person
that directly or indirectly controls, is controlled by, or is under common
control with such Person. For the purposes of this definition, "control"
(including the terms "controlled by" and "under common control with"), as
used with respect to any Person, shall mean the possession, directly or
indirectly, the power to direct or cause the direction of the management
and policies of such Person, whether through the ownership of voting
securities, by contract, or otherwise.
1.1.4 AGREEMENT: This Fixed Point Microwave Services Agreement,
including the Schedules and Exhibits attached hereto, as the same may be
amended, supplemented or modified in accordance with the terms hereof.
1.1.5 ALARM AND EVENT REPORT: As defined in SECTION 7.7 of
SCHEDULE A.
1.1.6 ARBITRATION RULES: As defined in SECTION 16.2.3.
1.1.7 AS-BUILT DRAWING: As defined in SECTION 4.1.4 of SCHEDULE
A.
1.1.8 AVAILABLE EXCESS CAPACITY: The total PathNet Excess
Capacity available (and not allocated) for use or sale on the System at any
given time from Commissioning through the Expiration Date.
1.1.9 AVERAGE SOLD EXCESS CAPACITY: The cumulative daily average
of [(PathNet Excess Capacity -- Available Excess Capacity)/PathNet Excess
Capacity], taken as a percentage.
1.1.10 BIT ERROR RATE: The number of received bits in error
compared to the total number of bits received.
1.1.11 BREACHING PARTY: As defined in SECTION 16.1.2.
1.1.12 BUSINESS DAY: Any day other than a Saturday, a Sunday, or a
day on which the banking institutions in either New York, New York, or the
city and state in which the principal executive offices of PathNet within
the United States are located, are not open for business.
1.1.13 CAPACITY EXPANSION: An increase in telecommunication
channels a System is able to transmit, receive and transport above those
created by the installation of the Initial System, achieved by an addition
to or change in equipment.
1.1.14 CAPACITY EXPANSION SCHEDULE: As defined in SECTION 7.1 of
SCHEDULE A.
1.1.15 CENTER: As defined in SECTION 16.2.3.
1.1.16 CERCLA: Comprehensive Environmental Response, Compensation
and Liability Act, 42 U.S.C. SECTION 6901 ET SEQ., as amended.
1.1.17 CHANNEL PLAN: As defined in SECTION 1.1 of SCHEDULE A.
1.1.18 COMMISSIONING: With respect to each path or Segment, the
date on which the circuits of such path or Segment are available for
service after completion of all required site acceptance testing.
1.1.19 CONFIDENTIAL INFORMATION: Any and all technical, business
and financial information, in whatever form, furnished or disclosed by one
Party to the other Party, including but not limited to information on the
System, cost estimates, technical data, information, pricing, and the terms
and conditions of this Agreement.
2
1.1.20 CUSTOMER AGREEMENTS: As defined in SECTION 9.8.1.
1.1.21 CUTOVER PLAN: As defined in SECTION 4.1.1 of SCHEDULE A.
1.1.22 DEFICIENCY LIST: As defined in SECTION 5.7 of SCHEDULE A.
1.1.23 DISPUTE: As defined in SECTION 16.2.1.
1.1.24 DROP AND INSERT: That process wherein a part of the
information carried in a transmission system is demodulated (dropped) at an
intermediate point and different information is entered (inserted) for
subsequent transmission.
1.1.25 DS-0: 64,000 bits per second; The world-wide standard speed
for digitizing one voice conversation using pulse code modulation, which is
approximately equivalent to a single voice or data channel.
1.1.26 DS-1: 24 DS-0's.
1.1.27 DS-3: 672 DS-0's or 28 DS-1's.
1.1.28 EFFECTIVE DATE: As defined in the introductory paragraph of
this Agreement.
1.1.29 ELECTION PAYMENT: As defined in SECTION 4.3.1 for Segment
A.
1.1.30 ELECTION PERIOD: The eighty-four (84) month period
following Commissioning of the Initial System on Segment A during which
Incumbent shall fund the Initial System up to the Incumbent Payment cap.
1.1.31 ENCUMBRANCES: Any security interests, mortgages, liens,
pledges, charges, claims, easements, reservations, restrictions, clouds,
equities, rights of way, options, rights of first refusal and other
encumbrances whether or not relating to the extension of credit or the
borrowing of money. To "Encumber" shall mean to effect any Encumbrance.
1.1.32 EQUIPMENT: Any and all digital microwave radios, radio
components, cards, antennas, waveguides, multiplexers, software and other
equipment or parts required for the operation of the System provided and
installed by PathNet and its subcontractors, as set forth on EXHIBIT A-1 to
SCHEDULE A.
1.1.33 ERROR FREE SECOND: Any one-second interval that does not
contain a measurable bit error.
1.1.34 ERRORED SECONDS: Any one-second interval during which one
or more bit errors occur.
3
1.1.35 EXCESS CAPACITY: The PathNet Excess Capacity and the
Incumbent Excess Capacity.
1.1.36 EXISTING SYSTEM INVENTORY: As defined in SECTION 1.1 of
SCHEDULE A.
1.1.37 EXPIRATION DATE: The date on which this Agreement and the
rights and obligations hereunder are terminated or expire in accordance
with SECTION 3.
1.1.38 FAA: The Federal Aviation Administration, or any other
Federal agency at the time administering tower registration requirements
and regulations.
1.1.39 FACILITIES: Incumbent's towers, shelters, sites and all
equipment owned by Incumbent relating to and used in association with such
towers, shelters and sites for the purpose of operating the System.
1.1.40 FAILED SECOND: Any one-second interval that has 1,544 bit
errors at a DS-1 rate.
1.1.41 FCC: The Federal Communications Commission, or any other
Federal agency at the time administering the Communications Act of 1934, as
amended, the Telecommunications Act of 1996, as amended and the rules and
regulations promulgated thereunder.
1.1.42 FCC CODE: The Communications Act of 1934, as amended, the
Telecommunications Act of 1996, as amended and the rules and regulations
promulgated thereunder and related thereto.
1.1.43 FIRST EXTENSION PERIOD: As defined in SECTION 3.2.2.
1.1.44 FORCE MAJEURE EVENT: As defined in SECTION 15.3.
1.1.45 FORM 415: As defined in SECTION 10.1.1.
1.1.46 FREQUENCY AVAILABILITY MODEL: As defined in SECTION 1.1 of
SCHEDULE A.
1.1.47 FREQUENCY DIVERSITY: A method of protecting a radio signal
by providing a second radio signal on a different frequency, which will
assume the radio signal load when the regular channel fails.
1.1.48 GOVERNMENTAL AUTHORITY: Any nation or government, any state
or other political subdivision thereof and any court, panel, judge, board,
bureau, commission, agency or other entity, body or other person exercising
executive, legislative, judicial, regulatory or administrative functions of
or pertaining to government.
4
1.1.49 HAZARDOUS MATERIAL: Any material amount of any substance,
matter or waste which is or becomes regulated by any Federal, state or
local law, ordinance, order, rule, regulation, code or any government
restrictions or requirement including, but not limited to, asbestos,
petroleum products and "Hazardous Substances" and "Hazardous Wastes" (as
such terms are defined in CERCLA and RCRA.)
1.1.50 INCUMBENT: As defined in the introductory paragraph.
1.1.51 INCUMBENT DESIRED PATH: As defined in SECTION 9.3.
1.1.52 INCUMBENT EXCESS CAPACITY: As defined in SECTION 9.1.2.
1.1.53 INCUMBENT INITIAL ALLOCATION OF CAPACITY: [***]
1.1.54 INCUMBENT ITEMS: As defined in SECTION 4.1.1(A).
1.1.55 INCUMBENT OUT-OF-POCKET PATH FUNDING: [Path Replacement
Costs -- ((i) Path PCS Recovery + (ii) any and all PathNet Funding for a
given Path + (iii) AFUDC + (iv) Overhead)].
1.1.56 INCUMBENT PAYMENT CAP: As defined in SECTION 4.1.1(B).
1.1.57 INCUMBENT REPRESENTATIVE: As defined in SECTION 17.11.
1.1.58 INITIAL PERIOD: As defined in SECTION 3.2.1.
1.1.59 INITIAL SYSTEM: The initial system with a 1 x 1
configuration which is comprised of the first 85 DS-1's (which is
equivalent to 2,040 DS-0's) of the System and the System's 85 DS-1 protect
channels.
1.1.60 INTERCONNECTION: The point at which a private network is
connected to (i) the PSTN, which can include IXC POPs, tandem access
points, the central office, internet service providers, or major industrial
customer points of presence or (ii) another private network.
1.1.61 INTERFERENCE: Any measurable impairment in the performance
of the System or the quality of the signals received or transmitted on the
System.
1.1.62 IXC: An inter-exchange carrier; a telephone company that
provides long-distance telephone service between LATA's but not within any
one LATA.
1.1.63 JUDGMENT: Any order, judgment, writ, decree, award or other
determination, decision or ruling of any court, judge, justice or
magistrate, any other Governmental Authority or any arbitrator.
5
1.1.64 LATA: Local Access and Transport Area; one of 161 local
geographic areas in the United States within which a local telephone
company may offer telecommunications services.
1.1.65 LOSSES: Any and all losses, claims, shortages, damages,
liabilities, expenses (including reasonable attorneys' and accountants'
fees), assessments, tax deficiencies and taxes (including interest and
penalties thereon) sustained, suffered or incurred by any Person, including
the Parties hereto, arising from any matter which is the subject of
indemnification under SECTION 14.
1.1.66 MAINTENANCE SERVICES AGREEMENT: The Maintenance Services
Agreement, by and between PathNet and Incumbent, as the same may be amended
from time to time in accordance with its terms.
1.1.67 MATERIAL ADVERSE EFFECT: Any event, fact, circumstance or
occurrence, which results or would result in a material adverse change in
or a material adverse effect on any of: (i) the condition (financial or
otherwise), business, performance, operations, properties, or prospects of
such Person; (ii) the legality, validity or enforceability of this
Agreement; or (iii) the ability of such Person to perform its material
obligations under this Agreement.
1.1.68 MODIFICATIONS SOW: As defined in SECTION 2.1 of SCHEDULE A.
1.1.69 NETWORK MANAGEMENT SYSTEM: As defined in SECTION 7.6 of
SCHEDULE A.
1.1.70 NETWORK MONITORING CENTER: As defined in SECTION 7.5 of
SCHEDULE A.
1.1.71 NON-BREACHING PARTY: As defined in SECTION 16.1.2.
1.1.72 NOTICE OF ELECTION: As defined in SECTION 14.3.
1.1.73 OC-3 MULTIPLEXER: Any device that multiplexes capacity
between the OC-3 and the DS-1 levels.
1.1.74 OPERATOR: Northern Plains Natural Gas Company, Operator of
Incumbent.
1.1.75 ORDER WIRE: A service channel consisting of a 64,000 bit
per second circuit between sites.
1.1.76 OSHA: The Occupational Safety and Health Act, as amended.
1.1.77 OUTAGE: When the Bit Error Rate in each second is worse
than 10-3 for a period of ten (10) consecutive seconds.
6
1.1.78 PART 101: Part 101 of Title 47 of the Code of Federal
Regulations, as amended.
1.1.79 PARTNER: Shall mean partners of Incumbent and the partners
of any Partner.
1.1.80 PARTY: As defined in the introductory paragraph.
1.1.81 PATH: The spatial separation between two microwave tower
facilities in the System.
1.1.82 PATH PCS RECOVERY: The total amounts actually recovered
from PCS bid winners on every Path comprising Segment A, as such amount may
change from time to time.
1.1.83 PATH REPLACEMENT COSTS: Total costs of the Incumbent Items
as defined in SECTION 4.1.1(A)(I) herein for Segment A, as reasonably
documented by PathNet and Incumbent, including Incumbent's Allowance for
Funds Used During Construction ("AFUDC") + Incumbent's Overhead
("Overhead") deferred in accordance with generally accepted accounting
principles per Path, PROVIDED, HOWEVER, that (i) the incremental costs of
providing back-to-back terminals at every site over the cost of a repeater
terminal for those sites planned by PathNet as repeater sites and (ii) any
costs associated with multiplexing from the DS-1 to DS-0 levels are
excluded from the definition of Path Replacement Costs. (Costs for any
tower, shelter, right-of-way and infrastructure currently existing and
owned by Incumbent are also excluded.)
1.1.84 PATH STUDIES: As defined in SECTION 1.1 of SCHEDULE A.
1.1.85 PATHNET: As defined in the introductory paragraph.
1.1.86 PATHNET ALLOCABLE REVENUE PERCENTAGE: [***]
1.1.87 PATHNET EXCESS CAPACITY: At any given time, the
telecommunications channels or DS-0's on a per mile basis that the System
creates, transports and receives, less the capacity allocated to Incumbent
and the protect channels, pursuant to the Channel Plan, as amended from
time to time.
1.1.88 PATHNET FUNDING: Any payment made by PathNet to Incumbent
for (i) Path Replacement Costs, (ii) any payment made by PathNet pursuant
to SECTION 4.1.1(B), and (iii) or the value of any services provided by
PathNet and included in Incumbent Items for Segment A and not paid for by
Incumbent, provided PathNet Funding shall equal [Path Replacement Costs -
(Incumbent Out-of-Pocket Path Funding + Path PCS Recovery + AFUDC +
Overhead)].
7
1.1.89 PATHNET SOFTWARE: The software (including applications
software and systems software) owned or licensed from a third party by
PathNet used to provide the services covered in this Agreement.
1.1.90 PCN: A Prior Coordination Notice sent pursuant to Part 101.
1.1.91 PERMITS: Any and all authorizations, approvals, consents,
licenses, permits, easements, certificates and other rights and permissions
necessary to conduct such Person's business and to own, lease and operate
such Person's properties as currently conducted, owned, leased or operated.
1.1.92 PERSON: An individual or a corporation, partnership, trust,
incorporated or unincorporated association, joint venture, joint stock
company, or other entity of any kind or any Governmental Authority.
1.193 POP: Point Of Presence - the interconnection between any
two facilities based networks.
1.1.94 PRE-COMMISSIONING TEST EQUIPMENT: All equipment required
for the testing required to be performed on the System pursuant to SECTION
5 of SCHEDULE A, including, but not limited to, all required digital volt
meters, optical power meters, oscilloscopes, RF signal generators, noise
figure meters, noise figure test sets, RF variable attenuators, DADE adjust
cables, receiver card extenders and extension cords.
1.1.95 PRELIMINARY CONSTRUCTION SCHEDULE: As defined in SECTION
1.1 of SCHEDULE A.
1.1.96 PROGRESS REPORT: As defined in SECTION 4.1.2 of SCHEDULE A.
1.1.97 PROJECT DRAWINGS: As defined in SECTION 1.3 of SCHEDULE A.
1.1.98 PROJECT MANAGEMENT PLAN: As defined in SECTION 4.1.1 of
SCHEDULE A.
1.1.99 PROJECT SCHEDULE: As defined in SECTION 4.1.1 of SCHEDULE
A.
1.1.100 PROTECTION CONFIGURATION: An engineering plan under which
channel capacity is protected either on a fully redundant basis or on a 1 x
n protection basis.
1.1.101 PSTN: Publicly Switched Telephone Network.
1.1.102 QUARTERLY REVENUE REPORT: As defined in SECTION 9.10.
1.1.103 RCRA: Resource Conservation and Recovery Act, 42 U.S.C.
SECTION 9601 ET SEQ., as amended.
8
1.1.104 REQUIREMENT OF LAW: With respect to any Person, all
Federal, state and local laws, rules, regulations, Judgments, injunctions,
standards, codes, limitations, restrictions, conditions, prohibitions,
notices, demands or other requirements or determinations of a court or
other Governmental Authority or an arbitrator, applicable to or binding
upon such Person, any of its property or any business conducted by it or to
which such Person, any of its assets or any business conducted by it is
subject.
1.1.105 REVENUE: As defined in SECTION 9.12.3.
1.1.106 SECOND EXTENSION PERIOD: As defined in SECTION 3.2.3.
1.1.107 SEGMENT: The portion of a microwave communications network
existing between two geographic points. For purposes of this Agreement,
SEGMENT A is the portion of Incumbent's microwave communications network
between Port of Xxxxxx, Montana and Ventura, Iowa. For purposes of this
Agreement, SEGMENT B is the portion of Incumbent's microwave communications
network between Ventura, Iowa and the terminus of Incumbent's System in
Illinois.
1.1.108 SERVICES: As defined in SECTION 7.1.
1.1.109 SEVERELY ERRORED SECONDS: Any one second interval where the
Bit Error Rate is greater than or equal to 1 x 10-3 at a DS-1 rate
regardless of the cause of degradation affecting the channel error
performance including, but not limited to, unprotected equipment failures
and any other factors that contribute to poor performance.
1.1.110 SONET: Synchronous Optical Network; a family of fiber-optic
transmission rates from 51.84 Mbps to 13.22 Gbps, created to provide the
flexibility needed to transport many digital signals with different
capacities and to provide a standard to which manufacturers may design.
1.1.111 SPACE DIVERSITY: Protection of a radio signal by providing
a separate antenna on the same tower to assume the radio signal load when
the regular transmission path on the primary antenna fades, thereby
ensuring continuous transmission.
1.1.112 SPARE PARTS: The equipment and parts provided by PathNet to
Incumbent pursuant to the performance of Incumbent's obligations under the
Maintenance Services Agreement.
1.1.113 SPECIFICATIONS: As defined in SECTION 7.2.
1.1.114 STATION LOG BOOK: As defined in SECTION 6.2 of SCHEDULE A.
1.1.115 SUBCONTRACTORS: Any firm, corporation, or person working
directly or indirectly for a company that furnishes or performs a portion
of the work, labor or material.
9
1.1.116 SWITCHED MOD SECTION: A section of network between two
adjacent back-to-back terminals.
1.1.117 SYSTEM: The high-capacity digital SONET microwave radio
equipment, antenna, waveguide, Facilities, Network Management System, all
other equipment and materials related thereto, and FCC licenses and other
licenses and Permits related thereof, operated for the purpose of
transmitting, receiving and transporting telecommunications signals over
Incumbent's Segments set forth on SCHEDULE B.
1.1.118 SYSTEM BUDGET: As defined in SECTION 1.1 of SCHEDULE A.
1.1.119 SYSTEM DESIGN: As defined in SECTION 1.1 of SCHEDULE A.
1.1.120 SYSTEM PAYMENT: As defined in SECTION 4.3.2(A) for Segment
B.
1.1.121 TECHNOLOGY: Inventions, ideas, processes, formulas, and
know-how.
1.1.122 TOWER ANALYSIS: As defined in SECTION 1.1 of SCHEDULE A.
1.1.123 WAYSIDE CHANNELS: The additional DS-1 of telecommunications
capacity within each radio beyond the base OC-3 capacity.
1.2 TERMS GENERALLY. The definitions in SECTION 1.1 and elsewhere in this
Agreement shall apply equally to both the singular and plural forms of the terms
defined. Whenever the context may require, any pronoun shall include the
corresponding masculine, feminine and neuter forms. The words "herein",
"hereof", "hereto" and "hereunder" and words of similar import refer to this
Agreement (including the Schedules and Exhibits) in its entirety and not to any
part hereto unless the context shall otherwise require. All references herein
to Sections, Exhibits and Schedules shall be deemed references to Sections of,
and Exhibits and Schedules to, this Agreement unless the context shall otherwise
require. Unless otherwise expressly provided herein or unless the context shall
otherwise require, any references as of any time to the "Certificate of
Incorporation," "Articles of Incorporation," "charter," "organizational or
constituent documents" or "Bylaws" of any Entity, to any agreement (including
this Agreement) or other contract, instrument or document or to any agreement
statute or regulation are to it as amended and supplemented from time to time
(and, in the case of a statute or regulation to any corresponding provisions of
successor statutes or regulations) up to and including the Effective Date. Any
reference in this Agreement to a "day" or number and "days" (without the
explicit qualification of "Business") shall be interpreted as a reference to a
calendar day or number of calendar days. If any action or notice is to be taken
or given on or by a particular calendar day, and such calendar day is not a
Business Day, then such action or notice shall be deferred until, or may be
taken or given on, the next Business Day.
SECTION 2. RELATIONSHIP OF THE PARTIES
10
2.1 INDEPENDENT CONTRACTOR, REPRESENTATIVE AND NETWORK MANAGER. Incumbent
shall appoint PathNet and PathNet shall serve in the following capacities during
the term of this Agreement:
2.1.1 INDEPENDENT CONTRACTOR. As an independent contractor,
PathNet will serve as Incumbent's representative in performing analytical
pre-design and design services and installing, testing and ensuring the
performance of the System, except that for any Capacity Expansion, PathNet
shall serve as Incumbent's sole and exclusive representative in accordance
with the terms and conditions set forth in SECTION 6 and in SCHEDULE A.
2.1.2 EXCLUSIVE MARKETING REPRESENTATIVE. As the exclusive
representative for the marketing and sale of Excess Capacity for Incumbent,
PathNet will market and sell the Excess Capacity created by System, as
described in SECTION 9.
2.1.3 NETWORK MANAGER. In the role of a network manager, PathNet
will serve as the point of contact for any Outage or trouble on the System
and shall operate the Network Management System and the Network Monitoring
Center as described in SECTION 7.5 and SECTION 7.6 of SCHEDULE A.
2.2 NO JOINT VENTURE, ETC. The Parties expressly disclaim any intention
to create, and nothing herein shall be construed as creating, a partnership,
joint venture, agency or employment relationship between PathNet and Incumbent.
2.3 RESTRICTIONS ON ACTIONS OF INCUMBENT. For the term of this Agreement,
Incumbent shall not operate parallel microwave telecommunications facilities or
systems to those set forth in SCHEDULE B for the purpose of selling or otherwise
providing any capacity on such parallel facilities or systems.
SECTION 3. TERM AND EXPIRATION
3.1 TERM, EXTENSION PERIODS AND RENEWAL.
3.1.1 TERM. This Agreement shall commence on the Effective Date
and shall be in full force and effect until the later of the expiration of
the Initial Period or any Extension Period of either Segment A or B, as set
forth in this SECTION 3, or until terminated by Incumbent as provided in
SECTION 3.3.
3.2 INITIAL AND EXTENSION PERIODS
3.2.1 INITIAL PERIOD. The initial term (the "INITIAL PERIOD")
shall commence upon the receipt of the FCC common carrier license for
Segment A and shall expire on the fourth (4th) anniversary of the
Commissioning of Segment B.
11
3.2.2 FIRST EXTENSION PERIOD. In the event the Average Sold
Excess Capacity is at least ten percent (10%) during the Initial Period,
the term of the Agreement shall be automatically extended for an extension
period (the "FIRST EXTENSION PERIOD") commencing on the day after the
expiration of the Initial Period and expiring on the tenth (10th)
anniversary thereafter; provided PathNet shall notify Incumbent of its
intent to exercise its option to extend the term of the Agreement at least
one hundred and eighty (180) days prior to the end of the preceding term.
3.2.3 SECOND EXTENSION PERIOD. In the event the Average Sold
Excess Capacity is at least twenty percent (20%) during the Initial Period
and the First Extension Period, the term of the Agreement shall be
automatically extended for a second extension period (the "SECOND EXTENSION
PERIOD") commencing on the day after the expiration of the First Extension
Period and expiring on the tenth (10th) anniversary thereafter; provided
PathNet shall notify Incumbent of its intent to exercise its option to
extend the term of the Agreement at least one hundred and eighty (180) days
prior to the end of the preceding term.
3.2.4 SUBSEQUENT EXTENSIONS. Upon expiration of the Second
Extension Period thereof this Agreement shall be automatically renewed for
a one-year term, and at the end of such one-year term for additional
one-year terms for each year thereafter, unless terminated by either Party
upon written notice to the other Party to that effect delivered at least
ninety (90) days before the end of the second extension period or any such
one-year term.
3.3 TERMINATION. To the extent PathNet (a) fails to make payment on the
undisputed portion of any of the following payments: (i) Election Payment
pursuant to the terms of SECTION 4.3.1(A), (ii) Any payment exceeding the amount
of the Incumbent Payment Cap pursuant to SECTION 4.1.1(B), (iii) System Payment
pursuant to SECTION 4.3.2(A), (iv) Payment of Revenue pursuant to SECTION
9.12.4; or (b) fails to meet the Average Sold Excess Capacity threshold as set
forth in SECTION 3.2.2 and SECTION 3.2.3, Incumbent shall have the right to
terminate this Agreement upon written notice to PathNet; provided that PathNet
shall have the right to cure its default caused by the failure to make any
payment pursuant to this SECTION 3.3(A), for a period of fifteen (15) days
following receipt of the written notice of default from Incumbent.
SECTION 4. COSTS
4.1 INCUMBENT COSTS.
4.1.1 INCUMBENT ITEMS AND INCUMBENT PAYMENT CAP
(a) INCUMBENT ITEMS. Incumbent shall pay for the services,
functions, materials and other items listed in (i)
SECTION 1.A and (ii) SECTION 1.B of SCHEDULE C
(collectively, the "INCUMBENT ITEMS") in the manner set
forth in SECTION 4.1.2.
12
(b) INCUMBENT PAYMENT CAP. Incumbent shall pay an amount
not to exceed [***] (the "INCUMBENT PAYMENT CAP") in
the aggregate for the performance and completion of the
Incumbent Items for Segment A. PathNet shall pay for
all amounts incurred over the Incumbent Payment Cap in
the completion and performance of the Incumbent Items
for Segment A provided that such costs will be included
as part of the PathNet Funding. As soon as Incumbent
is aware that the actual costs of Incumbent Items for
Segment A will exceed the Incumbent Payment Cap,
Incumbent shall notify PathNet to that effect.
4.1.2 PAYMENT FOR INCUMBENT ITEMS. Incumbent shall within thirty
(30) days pay for any Incumbent Items upon receipt of an invoice or other
xxxx from PathNet or from an equipment vendor or service provider (pursuant
to any PathNet requested retention), provided PathNet has approved such
purchase order, invoice or xxxx before any payment is made by Incumbent.
4.2 INCUMBENT OPERATING AND ADMINISTRATION COSTS. Incumbent shall pay the
operating and administration costs for Segments A and B, as set forth in SECTION
2 of SCHEDULE C as such costs are actually incurred and become due and payable
in the course of the Incumbent's performance of its obligations under this
Agreement.
4.3 PATHNET COSTS.
4.3.1 SEGMENT A.
(a) ELECTION PAYMENT. At any time during the Election
Period and from time to time, PathNet, in its sole
discretion, shall have the right to pay Incumbent any
amount of the Incumbent Out-of-Pocket Path Funding for
the right to additional future Revenue from the sale of
Excess Capacity on the System, provided any such
payment shall be included as part of PathNet Funding
(and the Incumbent Out-of-Pocket Funding shall be
recalculated) and the percentage Revenue paid to
Incumbent shall be adjusted pursuant to SECTION 5.1.1
to reflect an increase in PathNet Allocable Revenue
Percentage. As of the date of completion of the
Election Period or at any time during the Election
Period, PathNet, in its sole discretion, shall pay
Incumbent an amount equal to the current Incumbent
Out-of-Pocket Path Funding for the applicable paths (as
such Funding may be adjusted pursuant to any and all
additional PathNet Funding) on at least ninety (90%)
percent of Incumbent's Paths comprising Segment A of
the System ("Election Payment"), provided the
percentage Revenue paid to Incumbent shall be adjusted
pursuant to SECTION 5.1.1. If PathNet fails to pay the
13
Election Payment upon completion of the Election
Period, Incumbent shall have the right to terminate
this Agreement.
4.3.2 SEGMENT B.
(a) SYSTEM PAYMENT. Upon Commissioning of the Initial
System on Segment B, PathNet shall pay Incumbent the
quarterly payments as set forth in EXHIBIT C-2 to
SCHEDULE C ("System Payment").
4.4 PATHNET OPERATING AND ADMINISTRATION COSTS. PathNet shall pay for the
operating and administration costs on Segments A and B, as set forth in SECTION
3 of SCHEDULE C as such costs are actually incurred and become due and payable
in the course of PathNet's performance of its obligations under this Agreement.
4.5 CHANGE ORDERS. This Agreement anticipates (i) future issuance of
change orders for equipment and services beyond the scope of this SECTION 4, and
(ii) PathNet's provision of related equipment and services in accordance with
such orders. To the extent mutually agreed upon by the Parties, all such orders
shall be deemed to be supplements to and governed by the terms of this
Agreement; provided PathNet and Incumbent's Estimated Costs may be modified to
reflect any agreed upon change orders.
SECTION 5. REVENUE SHARING
5.1 SEGMENTS A AND B.
5.1.1 ALLOCATION OF CAPACITY AND REVENUE SHARING - SEGMENT A.
PathNet shall provide Incumbent Initial Allocation of Capacity and pay to
the Incumbent Revenue pursuant to the formulas set forth below: (i) upon
Commissioning of the Initial System, a percentage of Revenue, if any, from
the sale of PathNet Excess Capacity on Segment A of the Initial System
equal to [***]
14
5.1.2 REVENUE SHARING - SEGMENT B. PathNet shall pay to Incumbent
the following Revenue pursuant to the formulas set forth below: [***]
5.2 USE OF FACILITIES.
5.2.1 RIGHT TO OPERATE. Incumbent shall provide to PathNet the
exclusive right and PathNet shall have the right to install and operate the
System (including, without limitation, full access to such System) at each
of Incumbent's sites and Facilities, as set forth in SCHEDULE B, as is
required and necessary for the performance of PathNet's rights and
obligations under this Agreement.
5.2.2 PEACEFUL ENJOYMENT, USE AND ACCESS. Incumbent shall grant
to PathNet the right to the peaceful use, enjoyment and possession of the
Facilities during the term of this Agreement as required for the
performance of PathNet's rights and obligations under this Agreement, which
rights shall include, but not be limited to (i) the right to use
Incumbent's Facilities and (ii) upon the reasonable request by PathNet, the
right to full and free access to Incumbent's Facilities and related
equipment; PROVIDED, HOWEVER, any such access granted by Incumbent to
PathNet shall be subject to the security, health and safety and other
regulatory, procedural and policy requirements of Incumbent, as set forth
in SECTION 5.4. PathNet's continuous and uninterrupted non-use of the
Facilities for purposes described in this Agreement for one (1) year shall
be sufficient to demonstrate abandonment unless PathNet shall have notified
Incumbent in writing of its reasons for non-use.
5.2.3 INTERFERENCE. During the term of this Agreement, Incumbent
shall not license or otherwise permit any Person to use its Facilities
(including the transfer of any rights to the Facilities) if the use of such
Facilities by such Person would cause any Interference on the System. In
the event another tenant of Incumbent causes any Interference on the
System, Incumbent shall compel such tenant to immediately take all steps
necessary to correct and eliminate such Interference, including, without
limitation, enforcing provisions in any license or other agreement between
Incumbent and such tenant and compelling such tenant to cease operation of
such tenant's system, to remove such tenant's equipment or materials or to
modify such tenant's equipment or materials. Incumbent acknowledges that
any Interference shall cause irreparable harm to PathNet and the prompt
cessation of Interference is material to PathNet's interest in the
Facilities and PathNet's performance under this Agreement and, as such,
PathNet shall be entitled to injunctive relief in the enforcement of this
section.
15
5.3 VISITING AND EXITING FACILITIES. Upon exiting any Facility, PathNet,
on behalf of itself and its employees, agents and Subcontractors, shall ensure
that such Facility is returned to a condition, which existed immediately prior
to such visit.
5.4 INCUMBENT SECURITY PROCEDURES, POLICY ON DRUGS AND ALCOHOL AND SAFETY
REQUIREMENTS.
5.4.1 INCUMBENT SECURITY PROCEDURES. At the request of Incumbent,
PathNet shall require its employees, agents and Subcontractors upon any
site visit to comply with Incumbent's reasonable security procedures in
effect as of the Effective Date, which procedures are attached hereto as
SCHEDULE E. If and to the extent Incumbent requires PathNet employees,
agents or Subcontractors to be escorted to Incumbent facilities, such
requirements shall be explicitly set forth in SCHEDULE E. Notwithstanding
the foregoing, Incumbent shall allow PathNet employees, agents or
Subcontractors to bring any testing equipment, photographic equipment or
both video and audio recording equipment necessary for the performance of
PathNet's obligations under this Agreement.
5.4.2 INCUMBENT POLICY ON DRUGS AND ALCOHOL IN THE WORKPLACE. At
the request of Incumbent, PathNet shall require its employees, agents or
Subcontractors to comply with Incumbent's reasonable substance abuse
policies and procedures in effect as of the Effective Date, which policies
and procedures are attached hereto as SCHEDULE G.
5.4.3 INCUMBENT SAFETY PROCEDURES. At the request of Incumbent,
PathNet shall require its employees, agents and Subcontractors to comply
with Incumbent's reasonable rules and regulations governing the health and
safety of its employees in effect on the Effective Date, which rules and
regulations are attached hereto as SCHEDULE H.
5.4.4 CLEARANCES AND OTHER REQUIREMENTS. At the request of
Incumbent, PathNet shall require its employees, agents or Subcontractors to
(i) apply to Incumbent for any necessary reasonable clearances and (ii)
comply with all other reasonable and applicable requirements, rules,
regulations or ordinances regarding any Person's ability to have access to
Incumbent's sites and Facilities.
5.5 CO-LOCATION. Incumbent shall allow PathNet, at no additional charge,
to co-locate at Incumbent's Facilities all equipment necessary to support the
Interconnections set forth on EXHIBIT A-7 to SCHEDULE A and any additional
interconnections equipment that may be added by PathNet from time to time and at
any time during the term of this Agreement, subject to the limitations set forth
in SECTION 3 of SCHEDULE A.
5.6 REMOVAL OF EQUIPMENT. PathNet shall, at Incumbent's request,
remove any or all Equipment from any Capacity Expansion from Incumbent's
Facilities within sixty (60) days after the Expiration Date. In the event
PathNet fails to perform such requested removal within such sixty (60) day
period, as determined by Incumbent in its sole discretion, Incumbent may restore
each site to its condition as of Commissioning, (reasonable wear and tear and
damage
16
from the elements excepted), and PathNet shall promptly pay Incumbent all costs
reasonably incurred by Incumbent for such removal and restoration.
5.7 REMOVAL OF HAZARDOUS MATERIALS. Within ninety (90) days after
the Expiration Date, PathNet shall remove from Incumbent's sites any and all
Hazardous Materials, which were brought to Incumbent's sites by PathNet during
the term of this Agreement.
SECTION 6. PROGRAM MANAGEMENT; PROJECT MANAGEMENT; PROJECT SCHEDULE
6.1 PROGRAM MANAGER. In connection with the Services and other services
performed by PathNet under this Agreement, PathNet shall provide a program
manager whose duties shall include (i) supervising the project through design,
installation and operation, (ii) supervising the project manager, (iii)
overseeing the field manager and the other PathNet personnel, (iv) coordinating
the business operations of the System including the sale of Excess Capacity as
set forth in SECTION 9 and (v) ensuring the performance of PathNet's rights and
obligations under this Agreement.
6.2 PROJECT MANAGEMENT. In connection with the modifications and
installation of the Facilities set forth in SECTION 2 and SECTION 4 of SCHEDULE
A, PathNet shall provide a project manager, a field manager, an applications
engineer and a project engineer, each of whom shall have the duties as set forth
below:
6.2.1 PROJECT MANAGER. PathNet shall provide a project manager
whose duties shall include ensuring the overall functional integrity of the
delivered System, the preparation, amendment and adherence to a
construction schedule, and compliance with PathNet's other obligations
under SCHEDULE A.
6.2.2 FIELD MANAGER. PathNet shall provide a field manager whose
duties shall include the oversight and direction of all on-site activities,
the coordination of all Subcontractors and all required communication with
the project manager.
6.2.3 APPLICATIONS ENGINEER. PathNet shall provide an
applications engineer, whose duties shall include the review and
translation of the System configuration into specific hardware
requirements, precise interface levels, intra and inter-rack cabling and
all other necessary peripheral equipment, rack profiles and required
Interconnection data.
6.2.4 PROJECT ENGINEER. PathNet shall provide a project engineer
whose duties shall include the performance of all planning and support
activities and a detailed site survey to gather data for development of the
installation plan and testing plan.
6.3 PROJECT SCHEDULE. PathNet shall provide all reasonable efforts to
construct Segments A and B within seven (7) months from the time all permits and
approvals have been received; PROVIDED, HOWEVER, PathNet shall complete the
installation and construction of
17
Segment A by no later than December 31, 1997 and Segment B by no later than the
date of commencement of pipeline commercial operations.
SECTION 7. SERVICES AND SYSTEMS SPECIFICATIONS
7.1 SERVICES.
7.1.1 SYSTEM DESIGN, MODIFICATION, INSTALLATION, OPERATION AND
PERFORMANCE. PathNet and Incumbent shall perform their respective
functions with respect to the design, modification, installation, operation
and performance of the System as set forth on SCHEDULE A and in this
SECTION 7 (the "SERVICES").
7.1.2 UPGRADE OF SYSTEM. In the event PathNet sells at least
fifty (50%) percent of the Average Sold Excess Capacity of the System
configured at any time or can demonstrate commitments for the sale of such
Average Sold Excess Capacity, PathNet may, at its own expense, upgrade the
System and Equipment, and the System and Equipment operation policies and
procedures, including, but not limited to, (i) replacing Equipment, (ii)
adding newly available improved Equipment, and (iii) modifying policies,
procedures and specifications relating to the System, to conform such
policies, procedures and specifications with new Technology or industry
standards.
7.1.3 INCUMBENT TRAINING. PathNet shall provide to Incumbent the
training as set forth on SCHEDULE J.
7.1.4 PERFORMANCE OF THE SERVICES. PathNet shall have the right,
subject to Incumbent's approval, such approval shall not be unreasonably
withheld, to engage Subcontractors to perform any of the Services.
7.2 SPECIFICATIONS.
7.2.1 GENERAL. PathNet and Incumbent shall perform the Services
in accordance with any and all technical and operational specifications set
forth in SCHEDULE A (the "SPECIFICATIONS").
7.2.2 CHANNEL PLAN.
(a) ORIGINAL CHANNEL PLAN. On the Effective Date, Incumbent shall
deliver to PathNet a proposed T-1 channelization plan, as
detailed in EXHIBIT A-4, setting forth its proposed capacity
needs at each site listed on SCHEDULE B. Such capacity shall in
no event exceed Incumbent Initial Allocation of Capacity and
shall be subject to Drop and Insert capacity at each Switched Mod
Section. PathNet shall incorporate Incumbent's proposed
channelization plan into the Channel Plan subject to the
limitations set forth above.
18
(b) AMENDED CHANNEL PLAN. Incumbent shall have the right to modify,
its allocated capacity (as described in the Channel Plan) along
the network any time after Commissioning, provided that
sufficient Drop and Insert capacity exists between each Switched
Mod Section using available Wayside Channels to effect such
modification, by providing written notice to PathNet to such
effect. Within ninety (90) days after receipt of any such
written notice from Incumbent, PathNet shall make such
modification to the configuration of the Channel Plan at no
charge to Incumbent. Incumbent shall not reconfigure the Channel
Plan in any manner other than as set forth in this section.
7.2.3 SPECIFICATIONS, STANDARDS AND INSPECTIONS. In connection with
the Services set forth in SECTION 2 and SECTION 4 of SCHEDULE A, PathNet
shall comply with the following requirements:
(a) REASONABLE EFFORTS. PathNet shall use commercially reasonable
efforts to ensure that the modification of the System set forth
in SECTION 2 of SCHEDULE A and the installation of the System set
forth in SECTION 4 of SCHEDULE A occur as expeditiously as
possible.
(b) INDUSTRY STANDARDS. All Services and materials supplied pursuant
to SCHEDULE A must meet or exceed all applicable Specifications.
Where Specifications are not stated, such work performed and
materials supplied will meet all applicable provisions of the
following standards: (i) EIA RS-195 (latest edition), (ii)
EIA/TIA-222 (latest edition), (iii) American Society of Testing
Materials A 325 and A 572, (iv) the applicable sections of the
National Electric Code, (v) the American National Standards
Institute, (vi) XXX 000-00, (xxx) XXX-000, (xxxx) XXX-000, (xx)
OSHA 29 CFR 1910 and (x) all other applicable Federal, state and
local regulations of all Governmental Authorities with
jurisdiction; PROVIDED, HOWEVER, in the case of a conflicting
requirement of standards, the more stringent standard shall
apply.
(c) SITE INSPECTIONS. During the performance of the Services,
Incumbent shall allow PathNet to perform site inspections at any
hour, on any day subject to the access limitations set forth in
SECTION 5.4.1.
SECTION 8. OWNERSHIP, DEPRECIATION AND ENCUMBRANCE OF SYSTEM
8.1 OWNERSHIP OF EQUIPMENT AND ASSETS.
19
8.1.1 EQUIPMENT AND ASSETS OWNED BY INCUMBENT. Incumbent shall
own the equipment and assets relating to Segments A and B of the System as
set forth in SCHEDULE K.
8.1.2 EQUIPMENT AND ASSETS OWNED BY PATHNET. PathNet shall own
the equipment and assets relating to Segments A and B of the System as set
forth in SCHEDULE K.
8.2 DEPRECIATION OF EQUIPMENT.
8.2.1 DEPRECIATION BY INCUMBENT. Incumbent shall have the right
to fully depreciate for federal and state income tax purposes the equipment
and assets currently owned or to be owned by Incumbent as listed in
SCHEDULE K.
8.2.2 DEPRECIATION BY PATHNET. PathNet shall have the right to
fully depreciate for federal and state income tax purposes the equipment
and assets currently owned or to be owned by PathNet as listed in SCHEDULE
K.
8.3 ENCUMBRANCE.
8.3.1 INITIAL SYSTEM. PathNet shall not Encumber the radios,
radio software, antenna or waveguide used in the Initial System on Segments
A and B or any equipment or assets owned by Incumbent pursuant to SCHEDULE
K, or otherwise owned or leased by Incumbent, or any real estate or
infrastructure owned by Incumbent.
8.3.2 OTHER EQUIPMENT, MATERIALS, AGREEMENTS AND ASSETS. PathNet
shall have the right to Encumber (i) the Equipment used in any Capacity
Expansion on Segment A and B or any other equipment owned by PathNet
pursuant to SCHEDULE K, (ii) PathNet's share of Revenue as determined
under SECTION 5 of this Agreement, (iii) any Customer Agreement relating to
the System provided, however, that PathNet shall not encumber any of
Incumbent's rights under said Customer Agreements, (iv) PathNet's rights in
this Agreement and PathNet's rights in any related documents, instruments
and agreements executed and delivered in connection with this Agreement and
any rights and obligations hereunder or thereunder.
8.4 TAXES. The Parties' respective responsibilities for taxes arising
under or in connection with this Agreement shall be as follows: (i) each Party
shall be responsible for any personal or real property taxes on property it owns
or leases, for franchise and privilege taxes on its business and for taxes based
on its net income or gross revenue and (ii) PathNet shall be responsible for any
sales, use, excise, value-added services, consumption and other taxes and duties
payable by Incumbent on any goods and services used or consumed in providing the
services to be performed by PathNet under this Agreement, where the tax is
imposed on Incumbent's acquisition or use of such goods or services and the
amount of the tax is measured by Incumbent's costs in acquiring such goods or
services; PROVIDED, HOWEVER, that PathNet shall not be responsible for any
Federal, state or local income taxes of Incumbent or any franchise taxes of
Incumbent.
20
8.5 MAINTENANCE FOR SYSTEMS. Incumbent shall be responsible for the
maintenance of the System pursuant to the terms of a separate written agreement
to be entered into by the parties. The separate maintenance agreement shall
provide for ongoing maintenance of PathNet's microwave facilities.
SECTION 9. EXCESS CAPACITY MARKETING AND SALES
9.1 EXCLUSIVE REPRESENTATIVE.
9.1.1 PATHNET EXCESS CAPACITY. PathNet shall have the exclusive
right to market and sell any and all PathNet Excess Capacity.
9.1.2 INCUMBENT EXCESS CAPACITY. At any time and from time to
time, Incumbent shall have the right to request in writing that PathNet
serve as Incumbent's exclusive representative for the marketing and sale of
all or any portion of the capacity allocated to Incumbent in accordance
with the Channel Plan (the "INCUMBENT EXCESS CAPACITY"). In the event
PathNet sells any Incumbent Excess Capacity, PathNet shall receive a
marketing fee [***] of the revenue generated from the sale of such
Incumbent Excess Capacity actually collected, less any applicable
deduction set forth in SECTION 9.12.1 and SECTION 9.12.2 [***]. Incumbent
Excess Capacity shall be marketed on a pro rata basis with PathNet Excess
Capacity.
9.1.3 MARKETING AND SALE BY INCUMBENT. Incumbent or any
Affiliates of Incumbent shall not market or sell any Incumbent Excess
Capacity or any capacity purchased by Incumbent pursuant to SECTION 9.3 to
any third party without the prior written consent of PathNet; PROVIDED,
HOWEVER, Incumbent may market and sell all or any portion of the Incumbent
Excess Capacity or any capacity purchased by Incumbent pursuant to SECTION
9.3, to Affiliates of Incumbent for and only for such Affiliates' internal
communications needs and not for resale to third parties.
9.2 REFERRALS OF CUSTOMERS BY INCUMBENT. Incumbent shall refer any
potential third party customer of Excess Capacity to PathNet; PROVIDED that
if Incumbent is successful at referring a new (and previously unsolicited by
PathNet) Customer to PathNet, Incumbent shall receive a marketing fee not to
exceed [***] (in addition to other Revenue to be received by Incumbent) from
the sale of Excess Capacity on the System.
9.3 PURCHASE OF AVAILABLE EXCESS CAPACITY BY INCUMBENT. Incumbent
shall have the right to purchase Available Excess Capacity on any path or
Segment of the System (each such path or Segment being referred to herein as an
"INCUMBENT DESIRED PATH"), at a price equal to either (i) the lowest price paid
to PathNet for like capacity and for a similar term by any purchaser during the
one hundred eighty (180) days immediately preceding the purchase by Incumbent of
capacity on such Incumbent Desired Path less twenty-five (25%) percent or (ii)
if no PathNet Excess Capacity has been purchased on such Incumbent Desired Path
during such one hundred eighty (180) day period, the last price paid for such
Incumbent Desired Path less
21
twenty-five (25%) percent; PROVIDED, HOWEVER, Incumbent shall in no event
purchase more than twenty percent (20%) of the Available Excess Capacity on any
Segment or path within the System at any given time.
9.4 COMMERCIALLY REASONABLE EFFORTS. PathNet shall use commercially
reasonable efforts to obtain the best available price and terms in the marketing
and sale of any Excess Capacity. PathNet shall not, now or in the future,
guarantee any Revenue disbursements nor does PathNet warrant its ability to sell
the Excess Capacity.
9.5 SELLING PRICES FOR EXCESS CAPACITY. Notwithstanding anything set
forth herein to the contrary, PathNet shall have the right to (i) sell Excess
Capacity at prices determined by PathNet to be appropriate on specific routes,
which prices may be below or above current competitive market pricing, (ii)
package the Excess Capacity in sales increments of DS-1's, DS-3's or OC-3's, or
any other increments and (iii) aggregate the paths sold in various combinations,
each as determined by PathNet in its sole discretion.
9.6 BARTER ARRANGEMENTS. Incumbent shall be permitted to barter Incumbent
Excess Capacity, with PathNet's assistance, for telecommunications capacity of
other incumbents engaged by PathNet; PROVIDED, HOWEVER, PathNet shall have the
right to approve any barter arrangement relating to Incumbent Excess Capacity,
which approval shall not be unreasonably withheld. Neither PathNet nor
Incumbent shall derive any fee from facilitating any such barter arrangements.
9.7 ASSUMED NAME; TRADENAMES AND TRADEMARKS. PathNet shall have the right
to market Excess Capacity under its name or any other assumed name, tradename or
trademark which PathNet is authorized to use for such purpose; PROVIDED,
HOWEVER, PathNet shall not use any trademark or tradename of Incumbent or any
Affiliate of Incumbent in written material for purposes of marketing any Excess
Capacity without the prior written consent of Incumbent.
9.8 CUSTOMER AGREEMENTS.
9.8.1 AUTHORIZATION. PathNet shall negotiate, execute and
deliver, on behalf of itself and Incumbent, all agreements and arrangements
("CUSTOMER AGREEMENTS") for customers of Excess Capacity, which Customer
Agreements shall contain, terms and conditions determined by PathNet.
9.8.2 APPROVAL AND CONSENT BY INCUMBENT. If the terms of any
Customer Agreement require the written approval or consent of Incumbent as
a condition to the execution, delivery or performance, Incumbent shall
promptly provide such written approval or consent.
9.8.3 USE OF INCUMBENT'S NAME IN CUSTOMER AGREEMENTS FORBIDDEN.
In any customer agreements, PathNet shall not use Incumbent's name or name
of Incumbent's Operator or any of its Affiliates or imply in any manner
that Incumbent or its Operator or Affiliates are responsible in any manner
for the services provided in any Customer Agreements. Incumbent shall have
the right to review any Customer Agreements
22
executed between PathNet and its customers to verify that the terms
contained herein have not been violated.
9.8.4 MODIFICATIONS TO SYSTEM. In the event that any Customer
Agreement requires that the System be modified in any way, PathNet shall
ensure that any such modifications (i) shall not compromise the integrity
and performance of the System in accordance with the Specifications and
(ii) shall be made at no additional cost to Incumbent.
9.9 MAINTENANCE OF BOOKS AND RECORDS AND AUDIT PROCEDURES.
9.9.1 BOOKS AND RECORDS. PathNet shall maintain and keep detailed
and accurate books and records with regard to sales of Excess Capacity and
the Revenue generated and collected from such sales.
9.9.2 INCUMBENT REVIEW AND AUDIT PROCEDURES. No more than once
during any consecutive twelve (12) month period, Incumbent shall be
entitled to review and audit PathNet's books and records relating to the
sale of Excess Capacity during business hours upon ten (10) days written
notice to PathNet. Incumbent shall not have the right pursuant to this
SECTION 9.9.2, to review or audit PathNet's corporate income statements,
balance sheets or other forms of general corporate reporting. Incumbent
shall not disclose, at any time before or after the Expiration Date, any
information related to PathNet or PathNet's business obtained by Incumbent
pursuant to a review or audit performed under this SECTION 9.9.2 unless
such information has previously come into the public domain (other than
through unauthorized disclosure) or except as required by law.
9.9.3 EXPENSES OF INCUMBENT REVIEWS AND AUDITS. Incumbent shall
pay the cost of any such review or audit performed pursuant to SECTION
9.9.2.
9.9.4. APPROVAL OF AUTHORIZED REPRESENTATIVE. In the event that
Incumbent hires an authorized representative of Incumbent to perform any
such review or audit pursuant to SECTION 9.9.2, PathNet shall have the
right to approve such authorized representative before any access is
granted to such authorized representative to PathNet's books and records,
which approval shall not be unreasonably withheld.
9.10 QUARTERLY REVENUE REPORTS. PathNet shall issue to Incumbent quarterly
Revenue reports substantially in the form of SCHEDULE L (each a "QUARTERLY
REVENUE REPORT") within thirty (30) days after the end of each calendar quarter.
Each such Quarterly Revenue Report shall be an unaudited statement produced by
PathNet.
9.11 ANNUAL CERTIFIED REVENUE REPORTS. PathNet shall provide to Incumbent
on an annual basis an audited annual revenue report from a national accounting
firm.
9.12 COLLECTION AND PAYMENT OF REVENUE.
23
9.12.1 COSTS OF COLLECTION. PathNet shall deduct any costs
reasonably incurred by PathNet in connection with the collection of any and
all delinquent Revenue, including, but not limited to, the cost of any
legal actions, collection fees, court proceedings, audits, or other
enforcement actions. PathNet shall deduct such costs from gross revenue
collected prior to the disbursement of such revenue to PathNet and
Incumbent pursuant to SECTION 5.1 and SECTION 9.
9.12.2 TAXES ON GROSS REVENUE. The amount of any taxes on gross
revenue paid by PathNet on behalf of Incumbent shall be deducted from any
revenue to be disbursed to Incumbent prior to disbursement of such revenue
as set forth in this SECTION 9.12.
9.12.3 DEFINITION OF REVENUE. For purposes of this Agreement,
"REVENUE" shall mean the gross revenue generated from the sale of Excess
Capacity actually collected less any deductions set forth in SECTION 9.12.1
and SECTION 9.12.2.
9.12.4 PAYMENTS TO INCUMBENT. PathNet shall pay Incumbent its
allocated portion of Revenue actually received from the sale of Excess
Capacity either monthly or within thirty (30) days after the end of each
calendar quarter in accordance with the payment instructions set forth in
SCHEDULE M. If such payments are to be made quarterly, during the quarter,
until payment, PathNet shall place the Revenue due to Incumbent in an
interest bearing escrow account in the name of the Incumbent.
9.12.5 INTEREST EARNED ON UNDISTRIBUTED REVENUE. Incumbent shall
retain any and all interest earned on any Revenue collected but not yet
distributed to Incumbent in accordance with SECTION 5.1 and SECTION 9.
9.12.6 INCUMBENT'S ASSIGNEES OF REVENUE. Incumbent shall have the
right to designate other entities to receive its disbursements by written
notice to PathNet to such effect; PROVIDED, HOWEVER, any such designation
by Incumbent shall not relieve Incumbent of any tax liability resulting
from its receipt of such disbursements pursuant to SECTION 5.1 and SECTION
9.
SECTION 10. FCC LICENSES AND OTHER REGULATORY APPROVALS AND LICENSES
10.1 FCC RULES AND REGULATIONS.
10.1.1 MICROWAVE RADIO STATION LICENSES.
(a) Segments A and B.
i. PREPARATION AND FILING OF FORMS 415. PathNet shall prepare
and timely file all required Form 415, Applications for
Authorization in the Microwave Services (each a "FORM 415"),
or any successor forms,
24
documents or instruments to such Form 415 as the FCC may
prescribe, including but not limited to, the preparation or
ordering of all frequency coordinations required pursuant to
SCHEDULE B and SCHEDULE C of Form 415, in order to own,
operate and sell the Excess Capacity of Segments A and B of
the System in accordance with the terms and conditions of
this Agreement.
ii. IDENTITY OF LICENSEE. All Microwave Radio Station Licenses
issued by the FCC relating to the Initial System of Segments
A and B shall be licensed in the name of Incumbent or a
wholly-owned subsidiary of Incumbent. All Microwave Radio
Station Licenses issued by the FCC relating to any Capacity
Expansion on Segments A and B shall be licensed in the name
of PathNet or a wholly-owned subsidiary of PathNet.
Incumbent shall be permitted to continue to own and be
licensed as a private microwave operator at the stations
licensed to PathNet relating to Segments A and B of the
System, provided that (i) such private licenses are for
different frequency pairs than those assigned to the System
(including, but not limited to, any Capacity Expansion of
the System) and (ii) such private licenses are permitted
under the FCC Code.
iii. MAINTENANCE OF LICENSE. PathNet shall maintain in good
standing each Microwave Radio Station License relating to
the System, including, but not limited to, preparing and
filing any required amendments to the Forms 415 relating to
the System and submitting and filing any supplementary
information as required by the FCC.
10.1.2 COMMON CARRIER REPORTING OBLIGATIONS. Incumbent and PathNet
shall prepare and file all forms, reports, instruments, documents and
agreements required by the FCC and FCC Code relating to Incumbent's status
as a "common carrier" under the FCC Code.
10.1.3 TARIFF FILINGS. PathNet shall prepare and timely file all
tariff applications pursuant to 47 CFR 61, as amended, or any successor
statute, rule or regulation and shall request and file all necessary
waivers of such tariff requirements, as determined by PathNet in its sole
discretion.
10.1.4 FREQUENCY COORDINATION NOTICES. During the term of this
Agreement, PathNet shall prepare and send all required frequency
coordination notices required under 47 CFR 101.103, as amended, or any
successor statute, rule or regulation and shall respond as appropriate to
all PCNs received by PathNet or Incumbent relating to the System.
10.1.5 DELIVERY OF COPIES. PathNet shall provide to Incumbent a
copy of all filings and submissions with the FCC, relating to the System
within thirty (30) days of such filings and submissions.
25
10.1.6 ASSISTANCE IN PREPARATION OF LICENSE APPLICATIONS. Upon
request by PathNet and in a timely manner, Incumbent shall provide to
PathNet all information necessary for the completion of all required
filings and submissions with the FCC including, but not limited to
Incumbent's authorized signature on any filings or other submissions to the
FCC or any documents, instruments or agreements completed in connection
with such filings and submissions.
10.1.7 FUTURE CHANGES IN FCC REQUIREMENTS. If FCC requirements
relating to the Form 415, common carriers, frequency coordination or any
other matters relating to the System change or are modified, PathNet shall
be responsible for compliance with such new requirements including, but not
limited to, the payment of any costs or fees associated therewith and
Incumbent shall cooperate with PathNet with respect to such compliance;
PROVIDED, HOWEVER, if the FCC establishes user fees or other such fees
relating to the frequencies used in and the communications business
conducted over the System, the cost of such additional fees shall be
divided between PathNet and Incumbent, as determined by PathNet and
Incumbent at such time. In the event that fees are required for any FCC
mandated Universal Service Support Mechanism or any universal service fund
obligations are required by any federal or state law or regulation, PathNet
shall be solely responsible for such fees or obligations.
10.1.8 SPECTRAL LOADING REQUIREMENTS. PathNet shall (i) ensure
that the System, as licensed, shall comply with all spectral loading
requirements set forth in 47 CFR 101.141, or any successor statute, rule or
regulation or (ii) obtain a waiver of any or all of such requirements;
PROVIDED, HOWEVER, if the System does not meet such spectral loading
requirements and PathNet is unable to obtain a waiver of such requirements,
PathNet shall have the right to modify the System to a hot-standby
Protection Configuration until such time as the spectral loading
requirements can be met.
10.1.9 DEFAULT IN FCC LICENSE. In the event that the FCC
institutes a penalty against or fine imposed on PathNet, Incumbent, or the
System, due to non-compliance with any FCC requirements, PathNet shall
promptly pay such penalty or fine (in the case such penalty or fine is
instituted as the result of an act or omission on the part of PathNet) or
Incumbent shall promptly pay such penalty or fine (in the event such
penalty or fine is instituted as the result of an act or omission on the
part of Incumbent).
10.2 ZONING REQUIREMENTS. Incumbent shall be responsible for compliance
with all zoning requirements applicable to the System and its Facilities,
including, but not limited to, the Facilities. Incumbent shall advise PathNet
of zoning requirements, which, in the reasonable opinion of Incumbent, differ
from those generally applicable to microwave facilities. PathNet shall provide
to Incumbent all required information and shall cooperate with Incumbent in
connection with Incumbent's compliance with all zoning requirements pursuant to
this SECTION 10.2.
10.3 BUREAU OF LAND MANAGEMENT REQUIREMENTS. Incumbent shall be
responsible for compliance with all United States Department of Interior Bureau
of Land Management
26
requirements applicable to the System and its Facilities, including, but not
limited to, the Facilities. PathNet shall provide Incumbent with all requested
information and shall cooperate with Incumbent in connection with Incumbent's
compliance with such United States Department of Interior Bureau of Land
Management requirements pursuant to this SECTION 10.3.
10.4 TOWER REGISTRATION. Incumbent shall ensure compliance with all FAA
and FCC tower registration requirements including, but not limited to, the
preparation of any filings with or the obtaining of any waivers or extensions
from the FAA or FCC. Incumbent shall promptly notify PathNet of any deficiency
on non-compliance with any such tower registration requirements, filings,
waivers or extensions.
SECTION 11. INSURANCE
11.1 DELIVERY OF CERTIFICATES OF INSURANCE. Upon Incumbent's request and
prior to the commencement of any Services by PathNet, PathNet shall deliver to
Incumbent Certificates of Insurance relating to PathNet's Commercial General
Liability Insurance Policy, Workers Compensation Insurance Policy, Automobile
Liability Insurance and Excess Liability Insurance Policy.
11.2 PATHNET INSURANCE COVERAGE. During the term of this Agreement,
PathNet shall maintain the types of insurance at the coverage limits set forth
below:
11.2.1 WORKERS COMPENSATION AND EMPLOYER'S LIABILITY INSURANCE.
Workers Compensation Insurance with a limit of not less than $500,000;
11.2.2 COMMERCIAL GENERAL LIABILITY INSURANCE. Commercial General
Liability Insurance with a limit of not less than $1,000,000 per occurrence
and $1,000,000 in the aggregate;
11.2.3 AUTOMOBILE LIABILITY INSURANCE. Automobile Liability
Insurance, which includes coverage for non-owned and hired vehicles with a
limit of not less than $1,000,000; and
11.2.4 EXCESS LIABILITY INSURANCE. Excess Liability Insurance with
a limit of not less than $4,000,000.
11.3 INCUMBENT INSURANCE COVERAGE. Incumbent shall maintain insurance
coverage on the System which coverage shall include general liability and other
forms of insurance covering such risks as are usually insured against by prudent
companies engaged in the business and activities in which the Incumbent is
engaged, in amount which are adequate in relation to the business and properties
of Incumbent, and all premiums to date have been paid in full.
11.4 PROOF OF LICENSED SUBCONTRACTORS. Upon reasonable request of
Incumbent, PathNet shall provide to Incumbent proof of licensing and
certification of insurance for coverage
27
in types and amounts as set forth in SECTION 11.2 for any Subcontractors engaged
by PathNet to provide Services, during the term of such engagement.
SECTION 12. SOFTWARE AND PROPRIETARY RIGHTS
12.1 PATHNET SOFTWARE. PathNet retains all right, title and interest in
and to PathNet Software. As of the Effective Date and pursuant to the PathNet
Sublicense Agreement attached hereto as SCHEDULE N, Incumbent is granted a
nonexclusive sublicense to use PathNet Software for the sole purpose of
receiving the services pursuant to this Agreement. PathNet Software will be
made available to Incumbent in such form and on such media as exists on the
Effective Date, together with existing documentation and any other related
materials. Incumbent shall not be permitted to use PathNet Software for the
benefit of any entities other than PathNet without the prior written consent
which may be withheld at PathNet's sole discretion. Except as otherwise
requested or approved by PathNet, Incumbent shall cease all use of PathNet
Software upon expiration of this Agreement.
12.2 PROPRIETARY RIGHTS. Incumbent acknowledges and agrees that all or
portions of the information and materials, including but not limited to the
PathNet Software and related documentation to be supplied by PathNet hereunder
are owned by PathNet and/or others and are proprietary in nature. Incumbent
also acknowledges and agrees that PathNet and/or its suppliers have and will
retain all proprietary rights in such information and materials. Incumbent (i)
shall respect such claim of proprietary right, (ii) shall protect such
information at least to the extent that it protects its own proprietary
information, (iii) shall not use such information except for the purposes for
which its is being made available as set forth in this Agreement and (iv) shall
not reproduce, print, disclose, or otherwise make said information available to
any third party, in whole or in part, in whatever form.
SECTION 13. REPRESENTATIONS AND WARRANTIES
13.1 REPRESENTATIONS AND WARRANTIES OF EACH PARTY. Each Party hereby
represents and warrants the other Party as follows:
13.1.1 DUE INCORPORATION AND FORMATION; AUTHORIZATION OF
AGREEMENTS; BINDING EFFECT. Such Party is a corporation or partnership, as
the case may be, duly formed or organized, and validly existing under the
laws of its state of incorporation or organization, and has the corporate
or partnership authority to own its property and carry on its business as
owned and carried on as of the Effective Date. Such Party is duly licensed
or qualified to do business and is in good standing (if applicable) in each
jurisdiction in which the failure to be so licensed or qualified would have
a Material Adverse Effect on such Party. Such Party has the corporate or
partnership authority to execute and deliver this Agreement, to perform its
obligations hereunder, and to consummate the transactions contemplated
hereby. This Agreement has been duly authorized, executed and delivered by
such Party and this Agreement constitutes a legal, valid and binding
obligation of such Party enforceable in accordance with its terms,
28
subject as to enforceability to limits imposed by bankruptcy, insolvency or
similar laws affecting creditors rights generally and the availability of
equitable remedies.
13.1.2 NO CONFLICT; NO DEFAULT. Neither the execution or delivery
of this Agreement by such Party, nor (except as would not have a Material
Adverse Effect on such Party), the performance of this Agreement by such
Party or the consummation by such Party of the transactions contemplated
hereby in accordance with the terms and conditions hereof: (i) will
conflict with, violate, result in a breach of or constitute a default under
any of the terms, conditions or provisions of the certificate or articles
of incorporation or bylaws (or other governing documents) of such Party or
any material agreement or instrument to which such Party is a party or by
which such Party may be bound, (ii) will conflict with, violate or result
in a breach of, constitute a default under (whether with notice or lapse of
time or both), accelerate or permit the acceleration of the performance
required by, give to others any interests or rights or require any consent,
authorization or approval under any contract to which such Party is a party
or by which such Party is or may be bound or to which any equity interest
held by such Party or any of its material properties or assets is subject
or (iii) will result in the creation or imposition of any Encumbrance upon
any equity interest held by such Party or any of the other material
properties or assets of such Party, other than Permitted Encumbrances.
13.1.3 NO CONSENT. No consent, approval, order or authorization
of, or registration, declaration or filing with any Governmental Authority,
domestic or foreign, is required to be obtained by such Party in connection
with the execution and delivery of this Agreement. If and to the extent
any such consent, approval, order, or communication of registration,
delcaration or filing with any Governmental Authority, domestic or foreign
is required to perform under this Agreement or to consummate the
transaction contemplated hereby, such Party shall use good faith efforts to
obtain such consent, approval, order or authorization of, or registration,
declaration or filing with any Governmental Authority, domestic or foreign.
13.1.4 COMPLIANCE WITH LAWS AND REGULATIONS. That such Party is
not and that the performance of its obligations under this Agreement will
not result in a violation in any respect of (i) any applicable Federal,
state, local or foreign laws, ordinances, regulations, rulings and orders
of government agencies applicable to its business in any respect the
violation of which could have a Material Adverse Effect (including
Requirements of Law relating to pollution, protection of the environment,
emissions, discharges, releases or threatened releases of pollutants,
contaminants, chemicals, or industrial, toxic, hazardous or regulated
substances or wastes into the environment or otherwise relating to the
manufacture, processing, distribution, use, treatment, storage disposal,
transport or handling of pollutants or other such hazardous or regulated
substances or wastes) or (ii) any applicable order, Judgment, injunction,
award or decree in any respect which could have a Material Adverse Effect
on such Party.
13.1.5 PERMITS. Such Party has or will obtain all authorizations,
approvals, consents, licenses, Permits and certificates (including, but not
limited to all required approvals from the FCC) necessary to conduct their
respective businesses and to own, lease and operate its properties as
currently or anticipated to be conducted, owned, leased
29
or operated, as the case may be, for which the failure to possess would
result in a Material Adverse Effect. No violations are outstanding or
uncured with respect to any such Permits and no proceeding is pending to
revoke or limit any Permit.
13.1.6 LABOR MATTERS. Such Party has complied in all material
respects with all applicable Federal, state and local laws and ordinances
relating to the employment of labor, including the provisions thereof
relating to wages, hours, employee benefit plans and the payment of social
security taxes, and is not liable for any arrears of wages or any tax
related thereto (except for currently accrued and unpaid wages and except
for currently accrued withholding, payroll, unemployment and social
security taxes payment of which is not overdue) or penalties for failure to
comply with any of the foregoing, and neither has received a notice to the
contrary from any Governmental Authority. Such Party has not suffered any
strike, slowdown, picketing or work stoppage by any union or other group or
employees affecting the business of such Party, and no such event or action
is threatened.
13.1.7 NO DISCRIMINATION. Such Party currently subscribes and
offers and will continue to subscribe and offer to all customers,
employees, licensees, and invitees the opportunity to obtain all the goods,
services, accommodations, advantages, facilities and privileges of such
Party without discrimination because of race, creed, color, sex, age,
national origin or ancestry, in accordance with all applicable Federal,
state, and local laws relating to equal opportunity and discrimination.
13.1.8 DISCLAIMER. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NEITHER
PATHNET NOR INCUMBENT MAKES ANY OTHER EXPRESS WARRANTY AND THERE ARE NO
IMPLIED WARRANTIES WITH RESPECT TO ANY TECHNOLOGY, GOODS, SERVICES, RIGHTS
OR OTHER SUBJECT MATTER OF THIS AGREEMENT. PATHNET AND INCUMBENT HEREBY
DISCLAIM THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE WITH RESPECT TO ANY AND ALL OF THE FOREGOING.
13.2 REPRESENTATIONS AND WARRANTIES OF PATHNET.
13.2.1 HAZARDOUS MATERIALS. PathNet represents and warrants that
(i) PathNet is and shall remain in compliance with any and all Federal,
state or local laws, regulations or permits in regard to Hazardous
Materials, (ii) PathNet shall report to Incumbent and to applicable
Governmental Authorities any release of reportable quantities of a
hazardous substance as mandated by SECTION 103 (A) of CERCLA and (iii)
PathNet will, within five (5) Business Days of receipt, send to Incumbent a
copy of any notice, order, inspection report or other document issued by
any government authorities relating to PathNet's status with environmental
or health and safety laws.
13.2.2 SERVICES. PathNet warrants (i) that the Services will be
performed in a workmanlike manner and (ii) that it has or will obtain
agreements or arrangements with
30
its employees, agents and Subcontractors sufficient to allow it to provide
Incumbent with the Services;
13.2.3 TITLE TO ASSETS, PROPERTIES AND RIGHTS AND RELATED MATTERS.
Except as set forth herein, PathNet has good and marketable title to all
assets necessary for the conduct of PathNet's business and for the
transactions contemplated by this Agreement free and clear of all
Encumbrances of any kind or character, except (i) liens for current taxes
not yet due and payable, (ii) Encumbrances securing taxes, assessments,
governmental charges or levies or the Encumbrances of material, carriers,
landlords and like persons, all of which are not yet due and payable and
(iii) Encumbrances of a character that do not substantially impair the
ability of PathNet to carry out its obligations under this Agreement.
13.3 REPRESENTATIONS AND WARRANTIES OF INCUMBENT.
13.3.1 INDEPENDENT INVESTIGATION. Incumbent represents and
warrants that it has independently investigated the potential for the
success of PathNet's ability to create, aggregate and sell Excess Capacity
and has not relied upon any inducements or representations of PathNet or
its agents, other than those contained in this Agreement.
13.3.2 TITLE TO ASSETS, PROPERTIES AND RELATED MATTERS. Except as
set forth herein, Incumbent represents and warrants that it has good and
marketable title to all the properties, interests in properties and assets,
real, personal or mixed, (or the right to occupy said property by virtue of
easements, leases, permits, licenses or right-of-way grants) as set forth
on SCHEDULE D for Segment A (including, but not limited to, any
rights-of-way, leasehold interests, easements, and rights necessary to
insure vehicular and pedestrian ingress and egress to and from any such
properties or assets), free and clear of all Encumbrances of any kind or
character, except (i) liens for current taxes not yet due and payable, (ii)
Encumbrances securing taxes, assessments, governmental charges or levies or
the Encumbrances of materialman, landlords and like persons, all of which
are not yet due and payable and (iii) Encumbrances of a character that do
not substantially impair the ability of Incumbent to carry out its
obligations under this Agreement.
Incumbent is in the process of acquiring the property rights necessary
for the transactions contemplated by this Agreement on Segment B, but makes
no representations or warranties as to its ability to acquire such property
rights.
SECTION 14. INDEMNIFICATION
14.1 INDEMNIFICATION BY INCUMBENT. Incumbent agrees to indemnify, defend
and hold harmless PathNet and its Affiliates and their respective officers,
directors, employees, agents, successors and assigns from and against any and
all Losses and threatened Losses arising from, in connection with, or based on
allegations of, any of the following:
31
14.1.1 Any claims of infringement of any patent, trade secret,
copyright or other proprietary rights alleged to have occurred because of
systems or other resources provided to PathNet by Incumbent.
14.1.2 Any claims arising out of the untruth, inaccuracy or breach
of any representation or warranty of Incumbent set forth in this Agreement.
14.1.3 (i) Any personal injury, disease or death of any Person,
(ii) damage to or loss of any property, money damages or specific
performance owed to any Person (by contract or operation of law) or (iii)
any fines, penalties, taxes, claims, demands, charges, actions, causes of
action, assessments, environmental response costs, environmental penalties,
injunctive obligations caused by, arising out of, or in any way incidental
to, or in connection with, actions or omissions of Incumbent, its
employees, Subcontractors or agents.
14.2 INDEMNIFICATION BY PATHNET. PathNet agrees to indemnify, defend and
hold harmless Incumbent, its Partners, Operator, and Affiliates and their
respective officers, directors, employees, agents, successors and assigns from
and against any and all Losses and threatened Losses arising from, in connection
with, or based on allegations of, any of the following:
14.2.1 Any claims of infringement of any patent, trade secret,
copyright or other proprietary rights alleged to have occurred because of
systems or other resources provided to Incumbent by PathNet.
14.2.2 Any claims arising out of the untruth, inaccuracy or breach
of any representation or warranty of PathNet set forth in this Agreement.
14.2.3 (i) Any personal injury, disease or death of any person,
(ii) damage to or loss of any property, money damages or specific
performance owed to any Person (by contract or operation of law) or (iii)
any fines, penalties, taxes, assessments, environmental response costs,
environmental penalties or injunctive obligations caused by, arising out
of, or in any way incidental to, or in connection with, actions or
omissions of PathNet, its employees, Subcontractors or agents.
14.2.4 Any Losses, causes of action or suits arising out of
Customer Agreements.
14.3 INDEMNIFICATION PROCEDURES. With respect to any claims, the following
procedures shall apply:
14.3.1 NOTICE. Promptly after receipt by an entity entitled to
indemnification under SECTION 14.1 or SECTION 14.2 of notice of the
commencement or threatened commencement of any civil, criminal,
administrative or investigative action or proceeding involving a claim in
respect of which the indemnitee will seek indemnification pursuant to any
such Section, the indemnitee shall notify the indemnitor of such claim in
writing. No failure to so notify an indemnitor shall relieve it of its
obligations under this Agreement except to the extent that it can
demonstrate damages
32
attributable to such failure. Within fifteen (15) days following receipt
of written notice from the indemnitee relating to any claim, but no later
than ten (10) days before the date on which any response to a complaint or
summons is due, the indemnitor shall notify the indemnitee in writing if
the indemnitor elects to assume control of the defense and settlement of
that claim (a "NOTICE OF ELECTION").
14.3.2 PROCEDURE FOLLOWING NOTICE OF ELECTION. If the indemnitor
delivers a Notice of Election relating to any claim within the required
notice period, the indemnitor shall be entitled to have sole control over
the defense and settlement of such claim; provided that, (i) the indemnitee
shall be entitled to participate in the defense of such claim and to employ
counsel at its own expense to assist in the handling of such claim, and
(ii) the indemnitor shall obtain the prior written approval of the
indemnitee before entering into any settlement of such claim or ceasing to
defend against such claim. After the indemnitor has delivered a Notice of
Election relating to any claim in accordance with the section (a) above,
the indemnitor shall not be liable to the indemnitee for any legal expenses
incurred by the indemnitee in connection with the defense of that claim.
In addition, the indemnitor shall not be required to indemnify the
indemnitee for any amount paid or payable by the indemnitee in the
settlement of any claim for which the indemnitor has delivered a timely
Notice of Election, if such amount was agreed to without the written
consent of the indemnitor.
14.3.3 PROCEDURE WHERE NO NOTICE OF ELECTION IS DELIVERED. If the
indemnitor does not deliver a Notice of Election relating to any claim
within the required notice period, the indemnitee shall have the right to
defend the claim in such manner as it may deem appropriate, at the cost and
expense of the indemnitor. The indemnitor shall promptly reimburse the
indemnitee for all such costs and expenses.
14.4 SUBROGATION. In the event that an indemnitor shall be obligated to
indemnify an indemnitee pursuant to SECTION 14.1 or SECTION 14.2, the indemnitor
shall, upon payment of such indemnity in full, be subrogated to all rights of
the indemnitee with respect to the claims to which such indemnification relates.
SECTION 15. LIABILITY OF THE PARTIES TO EACH OTHER
15.1 LIABILITY GENERALLY. Subject to the specific provisions of this
SECTION 15, it is the intent of the Parties that each Party shall be liable to
the other Party for any actual damages incurred by the non-breaching Party as a
result of the breaching Party's failure to perform its obligations in the manner
required by this Agreement and failure to cure such nonperformance as set forth
in SECTION 16.1.2.
15.2 LIABILITY RESTRICTIONS.
15.2.1 SUBJECT TO SECTION 15.2.2 BELOW, IN NO EVENT, WHETHER IN
CONTRACT OR IN TORT (INCLUDING BREACH OF WARRANTY, NEGLIGENCE AND STRICT
LIABILITY IN TORT), SHALL A PARTY BE LIABLE
33
TO THE OTHER PARTY FOR INDIRECT, CONSEQUENTIAL, EXEMPLARY, PUNITIVE OR
SPECIAL DAMAGES EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES IN ADVANCE.
15.2.2 The limitations set forth in SECTION 15.2.1 shall not apply
with respect to: (i) damages occasioned by the willful misconduct or gross
negligence of a Party, (ii) damages occasioned by improper or wrongful
termination of this Agreement or (iii) damages occasioned by a violation of
SECTION 12 of this Agreement.
15.2.3 Each Party shall have a duty to mitigate damages for which
the other Party is responsible.
15.2.4 Each Party shall be liable to the other Party for any actual
damages as set forth in SECTION 15.1 only if, and to the extent that the
aggregate of all losses arising from or in connection with any such failure
to perform obligations in the manner required by this Agreement exceeds ten
thousand dollars ($10,000.00).
15.2.5 PathNet agrees that all claims arising from and out of the
terms of this Agreement shall be limited to the assets of Incumbent and
that all rights or remedies at law or in equity against Incumbent's
Partners by PathNet, its successors, assigns and representatives are hereby
expressly waived.
15.3 FORCE MAJEURE. No Party shall be liable for any breach, default or
delay in the performance of its obligations under this Agreement (i) if and to
the extent such default or delay is caused, directly or indirectly, by: fire,
flood, earthquake, elements of nature or acts of God, riots, civil disorders,
rebellions or revolutions in any country, Requirements of Law relating to the
System or to the sale of Excess Capacity, or any other cause beyond the
reasonable control of such Party (a "FORCE MAJEURE EVENT"), (ii) provided the
non-performing Party is without fault in causing such breach, default or delay,
and such breach, default or delay could not have been prevented by reasonable
precautions and cannot reasonably be circumvented by the non-performing Party
through the use of alternate sources, work around plans or other means.
SECTION 16. INFORMAL DISPUTE RESOLUTION; ARBITRATION
16.1 INFORMAL DISPUTE RESOLUTION.
16.1.1 ROLE OF PROGRAM MANAGER. In the event Incumbent has a
dispute, controversy or other complaint relating to PathNet's performance
of PathNet's rights and obligations under this Agreement, Incumbent shall
have the right to first contact the Program Manager to resolve such
dispute, controversy or other complaint. If Incumbent is not satisfied
with the resolution provided by the Program Manager, Incumbent may resort
to the arbitration procedures set forth in this SECTION 16.
16.1.2 NOTICE OF BREACH, CURE AND REMEDIES. In the event of a
material breach by either PathNet or Incumbent (the "BREACHING PARTY"), the
other Party (the "NON-
34
BREACHING PARTY") shall send by certified mail a written notice of such
material breach to the Breaching Party setting forth the specific
allegations of such breach. Upon receipt of the notice of breach, the
Breaching Party shall have thirty (30) days to cure such breach. In the
event the Breaching Party fails to cure such breach, as determined by the
Non-Breaching Party in its sole discretion, or the Breaching Party
determines, in its sole discretion, that it has cured such breach, either
the Breaching Party or the Non-Breaching Party may invoke the arbitration
procedures set forth in SECTION 16.2 to resolve whether such breach has
been cured.
16.1.3 SCOPE OF ARBITRATION AND DISPUTE RESOLUTION. SECTION 16 and
the arbitration and dispute resolution mechanisms provided herein shall not
apply to Incumbent's right to terminate this Agreement as provided in
SECTION 3.3.
16.2 ARBITRATION.
16.2.1 ARBITRATION; RESOLUTION OF DISPUTES. Except as provided in
SECTION 16.1.3, any and all disputes and controversies between Incumbent
and PathNet concerning the negotiation, interpretation, performance,
determination of amounts due either Party, breach or termination of this
Agreement (each a "DISPUTE") shall be subject to resolution as set forth in
this SECTION 16.
16.2.2 SETTLEMENT DISCUSSIONS. Subject to SECTION 16.1, any
Dispute shall be attempted to be resolved first through amicable settlement
discussions and each Party shall bear its own costs of such settlement
discussions. Each Party hereby agrees to use good faith efforts to reach a
settlement through such amicable settlement discussions.
16.2.3 REFERRAL TO BINDING ARBITRATION. In the event the Parties
fail to reach a settlement of the Dispute pursuant to settlement
discussions in accordance with SECTION 16.2.2, each Party shall have the
right, but not the obligation, to refer such Dispute for final resolution
by binding arbitration in accordance with the Center for Public Resources'
(the "CENTER") Rules for Non-Administered Arbitration of Business Disputes
(the "ARBITRATION RULES").
16.2.4 BINDING EFFECT. The Parties acknowledge and agree that (i)
the award in any arbitration shall be final, conclusive and binding on the
Parties and (ii) any such arbitration award be a final resolution of the
Dispute between the Parties to the same extent as a final judgment of a
court of competent jurisdiction.
16.2.5 USE OF COURTS AND OTHER LEGAL REMEDIES. Each Party
covenants and agrees that it shall not resort to any court for legal
remedies concerning any Dispute other than to enforce a final decision by
the arbitrators or for preliminary, interim or provisional equitable relief
in aid of arbitration.
16.2.6 ARBITRATION PROCESS.
(a) NOTICE. If the Parties cannot resolve a Dispute to their
mutual satisfaction pursuant to SECTION 16.2.2, either Party
may deliver to
35
the other Party a written notice in accordance with the
Arbitration Rules.
(b) SITE AND ARBITRATION TRIBUNAL. Absent agreement to the
contrary by the Parties, the arbitration will be conducted
in Omaha, Nebraska by a panel of three (3) arbitrators with
expertise in the fields of telecommunications engineering
and construction, PROVIDED, HOWEVER, in the case of
particular witnesses not subject to subpoena at the
designated hearing site, hearings may be held at any place
designated by the arbitrators where such witnesses can be
compelled to attend, and, with the consent of the Parties,
before a single member of the arbitration tribunal. Within
thirty (30) days after the filing of the notice of
arbitration, each Party must select one (1) arbitrator and a
third arbitrator will be selected by agreement of the two
(2) arbitrators selected by the Parties. If either Party
fails to select an arbitrator or there is no agreement on
the selection of the third arbitrator, the Center will
select such arbitrators.
(c) TRANSCRIPTS AND EVIDENCE. Both Parties shall cause a
written transcript of all proceedings and testimony shall be
kept and the cost of such transcript shall be borne equally
by the Parties pending the final award. All documents that
either Party proposes to offer in evidence, except for those
objected to by the other Party, shall be deemed to be
self-authenticating.
(d) APPLICABLE LAW. The arbitrator shall determine the claims
of the Parties and render their final award in accordance
with the governing law of this Agreement as set forth in
SECTION 17.5. Notwithstanding anything set forth in the
Arbitration Rules to the contrary, the provisions of this
SECTION 16 shall govern any arbitration proceeding brought
in relation to this Agreement or the transactions
contemplated thereby.
(e) SANCTIONS. The Parties acknowledge that, in addition to any
other remedy allowed or specified in or under the
Arbitration Rules, the failure of a Party to comply with any
interim, partial or interlocutory order, after due notice
and opportunity to cure such non-compliance, may be treated
by the arbitrators as a default and all or some of the
claims or defenses of the defaulting Party may be stricken
and partial or final award entered against such Party, as
determined by the arbitrators in their sole discretion,
sanctions as such arbitrators deem appropriate.
(f) LIMITATION ON AWARDS. Except as provided in SECTION 15.2.2,
arbitrators may not award (i) incidental, special,
consequential or
36
punitive damages in the resolutions of any Dispute and the
Parties hereby waive all rights to and claims for monetary
awards other than compensatory damages, (ii) the right to
terminate this Agreement or any of the rights and
obligations hereunder, or (iii) any other right or remedy
that contravenes the terms and conditions of this Agreement.
(g) PERIOD OF LIMITATIONS. In the event the Party claiming a
Dispute does not institute binding arbitration within one
(1) year after the commencement of settlement discussions
pursuant to SUBSECTION 16.2.2, such Party shall forever be
barred from bringing a claim on the specific subject matter
of such Dispute.
(h) ARBITRATION AWARD. Any arbitration award must be in writing
and must contain findings of fact and conclusions of law
upon which the arbitrators relied in making the decision
relating to such award.
(i) ATTORNEYS' FEES. The arbitrator shall award the reasonable
cost, including attorneys' fees, to the prevailing Party.
SECTION 17. MISCELLANEOUS
17.1 NOTICES. All notices pertaining to disputes arising from this
Agreement shall be directed to a corporate entity or employee designated by the
signatories as having full rights and responsibilities to address such issues.
Notices under this Agreement shall be sufficient only if personally delivered by
a commercial prepaid delivery or courier service or mailed by certified or
registered mail, return receipt requested to a Party at its address set forth
below or as amended by notice pursuant to this SECTION 17.1. If not received
sooner, notice by mail shall be deemed received five (5) business days after
deposit in the U.S. mail. All notices shall be delivered as follows:
If to PathNet:
Xxxxxxx X. Xxxxx, Esquire
Vice President and General Counsel
PathNet, Inc.
0000-00xx Xxxxxx, XX
Xxxxxxxxxx, XX 00000
Tel: 000.000.0000
Fax: 000.000.0000
If to Incumbent:
Xx. Xx Xxxxxxx
Director, Functional Strategies
Northern Border Pipeline Company
0000 Xxxxx 000xx Xxxxxx
00
Xxxxx, XX 00000-0000
Tel: (000) 000-0000
Fax: (000) 000-0000
17.2 BINDING NATURE; ENTIRE AGREEMENT. PathNet and Incumbent acknowledge
that (i) each has read and understands the terms and conditions of this
Agreement and agrees to be bound by such terms and conditions, (ii) this
Agreement shall be binding on each of PathNet and Incumbent and their respective
successors and assigns, (iii) this Agreement is the complete and conclusive
statement of the agreement between the Parties, (iv) this Agreement supersedes
any and all prior agreements and arrangements between the Parties and all
understandings and agreements, oral and written, heretofore made between
Incumbent and PathNet are merged in this Agreement which alone, fully and
completely expresses their agreement on the subject matter of this Agreement and
(v) this Agreement sets forth the entire agreement on the subject matter hereof.
17.3 AMENDMENT. No modifications of, additions to or waiver of this
Agreement shall be binding upon Incumbent or PathNet unless such modification,
addition or waiver is in writing and signed by an authorized representative of
each Party.
17.4 SEVERABILITY. If any term or provision of this Agreement shall to any
extent be held by a court or other tribunal to be invalid, void or
unenforceable, then such term or provision shall be inoperative and void insofar
as it is in conflict with the law, but the remaining terms and provisions of
this Agreement shall nevertheless continue in full force and effect and the
rights and obligations of the Parties shall be deemed to be restated to reflect
as nearly as possible the original intentions of the Parties in accordance with
applicable law.
17.5 GOVERNING LAW. This Agreement, and the rights and obligations of the
Parties hereunder, shall be governed and interpreted in accordance with the laws
of the State of Nebraska (other than the choice of law rules thereof).
17.6 SURVIVAL. Any provision of this Agreement which completes performance
or observance subsequent to any termination or expiration of this Agreement
shall survive such termination of expiration and continue in full force and
effect.
17.7 ASSIGNMENT. At any time and from time to time, PathNet shall have the
right to assign this Agreement or any of PathNet's rights and obligations under
this Agreement; provided, that in no event shall any such assignment relieve
PathNet of its obligations under this Agreement. Incumbent may not or shall not
have the right to assign this Agreement or any of its rights and obligations
hereunder, PROVIDED, HOWEVER, Incumbent may assign its right and obligations, in
whole but not in part, under this Agreement without the approval of PathNet, to
any entity which acquires all or substantially all of the assets of Incumbent or
to any subsidiary, Affiliate or successor in a merger or consolidation of
Incumbent; provided, that in no event shall any such assignment relieve
Incumbent of its obligations under this Agreement.
38
17.8 WAIVER. Failure or delay on the part of Incumbent or PathNet to
exercise any right, power or privilege under this Agreement shall not constitute
a waiver of any right power or privilege of this Agreement.
17.9 GOOD FAITH RENEGOTIATION. Notwithstanding anything set forth herein
to the contrary, the Parties hereby agree that in the event a Governmental
Authority issues a decision, order, rule or other rulemaking of any kind, which
necessitates any modification or amendment to this Agreement, the Parties shall
negotiate in good faith to modify or amend this Agreement to comply with such
decision, order, rule or other rulemaking.
17.10 CONFIDENTIALITY. Except as otherwise provided in this section,
the Parties agree that all Confidential Information shall be kept in confidence
and shall not, without the prior written consent of the disclosing Party, be
disclosed by the receiving Party in any manner whatsoever, in whole or in part,
and that they will use the Confidential Information disclosed to them solely for
the purposes of this Agreement unless otherwise specifically authorized in
writing by the disclosing Party, or specifically required by an order of a
regulatory agency or court of competent jurisdiction, in which case the Parties
agree to use their best efforts to limit disclosure through a protective order
or other similar means. Notwithstanding the foregoing,the existence of this
Agreement shall not be Confidential Information and either Party may disclose
Confidential Information to its partners, operator, Affiliates, parent
corporations, investors, investment bankers, creditors, third party contractors,
capacity purchasers and their applicable respective employees, attorneys and
agents, provided that such disclosure is made only to those persons with a
legitimate need to know such Confidential Information for purposes consistent
with this Agreement.
17.11 INCUMBENT'S DESIGNATED REPRESENTATIVE. Incumbent shall on the
Effective Date designate in writing a representative who shall have express
authority to bind Incumbent with respect to all matters requiring Incumbent's
approval or authorization in connection with this Agreement (the "INCUMBENT
REPRESENTATIVE"). Such Incumbent Representative shall have the authority to
make decisions and grant any and all consents required under this Agreement on
behalf of Incumbent and PathNet shall be entitled to rely on any such decision
or consent by the Incumbent Representative.
17.12 OUTSOURCING. In addition to, and not in place of, any rights of
PathNet under this Agreement, PathNet shall have the right to engage third party
Subcontractors to perform any or all of PathNet's rights and obligations under
this Agreement.
17.13 UNION AND LABOR RELATIONS. With respect to any services
performed pursuant to this Agreement, Incumbent shall ensure all such services
comply with all applicable labor or union-related agreements, regulations and
ordinances and shall not require PathNet to join any union or other labor
organization as a condition to performing services contemplated by this
Agreement.
39
IN WITNESS WHEREOF, the Parties hereto have executed this Agreement, as of the
date first written above.
PATHNET, INC.
By: /s/ Xxxx Xxxxxxxxx
---------------------------------
Name: Xxxx Xxxxxxxxx
Title: Chairman
NORTHERN BORDER PIPELINE COMPANY
By: Northern Plains Natural Gas Company, Operator
By: /s/ Xxxxx X. XxXxxx
---------------------------------
Name: Xxxxx X. XxXxxx
Title: President
SCHEDULE A
SERVICES AND SYSTEM SPECIFICATIONS
This Schedule A describes certain services and specifications that PathNet
and Incumbent shall respectively perform with respect to Segments A and B of the
System. PathNet's and Incumbent's responsibilities with respect to particular
Services and Specifications described in this Schedule A, if any, are
specifically indicated where such Services and Specifications are described.
PathNet's and Incumbent's payment responsibilities with respect to the Services
and Specifications shall be as set forth in Section 4 and Schedule C.
SECTION 1. PRELIMINARY ENGINEERING STUDIES AND EVALUATION OF EXISTING SYSTEM
1.1 Preliminary Analysis. PathNet shall complete a detailed analysis of
the existing microwave system operated by Incumbent along each Segment set forth
in Schedule B and upon completion of such analysis shall deliver the results of
such analysis to Incumbent. Such analysis shall include:
1.1.1 an inventory and survey of Incumbent's existing microwave
sites and supporting facilities (the "Existing System Inventory");
1.1.2 microwave path studies and reliability analysis to provide
performance data to serve as the engineering basis for the design of the
System (the "Path Studies");
1.1.3 a preliminary evaluation of the probability of successfully
coordinating frequencies on the System (the "Frequency Availability
Model");
1.1.4 a determination of whether structural analysis of towers and
loading factors (for metal towers only) is required and, in the event such
structural analysis is required, the analysis of Incumbent's towers,
including, but not limited to, the wind loading and weight requirements
for the proposed antenna systems as well as any feedlines necessary to
support the such antenna systems (the "Tower Analysis");
1.1.5 the design of the System (the "System Design") which System
Design conforms with the terms and conditions of Section 3 of this
Schedule A;
1.1.6 a detailed line item budget for the System (the "System
Budget");
1.1.7 a proposed T-1 plan for channelization of the System the
("Channel Plan"); and
1.1.8 a preliminary construction management schedule for each
replacement Segment (the "Preliminary Construction Schedule").
A-1
1.2 Cooperation of Incumbent with Preliminary Analysis. Incumbent shall
fully cooperate with PathNet in PathNet's performance of the preliminary
analysis set forth in Section 1.1 of this Schedule A, including, but not limited
to, providing to PathNet any requested information and documents relating to
Incumbent or Incumbent's existing system.
1.3 Project Drawings. Upon completion of the preliminary engineering
studies and analysis and documentation as set forth in Section 1.1 of this
Schedule A, PathNet shall deliver to Incumbent the following project drawings:
(i) a System layout drawing, (ii) the rack profiles, (iii) block drawings, and
(iv) equipment wiring drawings (collectively, the "Project Drawings.")
SECTION 2. MODIFICATION TO EXISTING INFRASTRUCTURE
2.1 Documentation. Upon completion of the preliminary analysis as set
forth in Section 1.1 of this Schedule A, PathNet shall prepare and deliver to
Incumbent a project management schedule and scope of work (the "Modifications
SOW") setting forth a detailed plan to complete all required modifications of
Incumbent's existing sites and Facilities necessary for the installation and
operation of the new System in accordance with the terms and conditions of this
Agreement. Incumbent shall have twenty (20) days to either (i) approve by
written notice to PathNet such Modifications SOW or (ii) deliver to PathNet a
written list of Incumbent's modifications to the Modifications SOW. PathNet
shall review any such modifications and, incorporate any reasonable suggested
modifications into the Modifications SOW pursuant to the Specifications and
Services provided herein. In the event Incumbent does not notify PathNet in
writing within the prescribed time period, PathNet shall assume that Incumbent
has granted such approval.
2.2 Modifications Required. PathNet or its designated subcontractors shall
perform all of the modifications set forth in the Modifications SOW. Such
modifications shall include the following:
2.2.1 any required modifications to the towers necessary to conform
the towers to the Specifications;
2.2.2 any required modifications to the battery reserves necessary
to conform the battery reserves to the Specifications and the installation
of any required generators, in accordance with the Specifications;
2.2.3 any required modifications to the environmental control
systems of the existing shelters necessary to conform such environmental
control systems to the Specifications;
2.2.4 the provision of all necessary D.C. and A.C. power cable
engineering for all racks, including, but not limited to, the installation
of all necessary conduits required to carry D.C. and A.C. power,
terminating cables and alarm cables and the installation of all necessary
A.C. distribution and A.C. wiring as required to meet the Specifications;
A-2
2.2.5 the installation of all required new equipment shelters, or
modification of existing equipment shelters, to conform to the
Specifications;
2.2.6 the installation of all required liquid petroleum from the
existing liquid petroleum tank or source, as the case may be, to the new
shelter in accordance with the Specifications;
2.2.7 any required modifications to the foundation of any of the
towers, shelters or sites as set forth in the Tower Analysis;
2.2.8 any upgrades required to conform the sites and Facilities to
local building code provisions and any other regulatory Requirements of
Law, including, but not limited to, those related to health and safety;
2.2.9 the removal of any above or below ground obstructions or
materials such as trees and power lines which may affect the performance
of the System or other activities contemplated by this Agreement;
2.2.10 all required fence extensions and replacements;
2.2.11 any required modifications to the grounding and bonding
Systems at each site to conform to the Specifications;
2.2.12 any required modifications to the pressurizing equipment to
conform to the Specifications, including the pressurizing equipment
manifolds and dehydrators; and
2.2.13 any other miscellaneous site work necessary to prepare
Incumbent's sites for the installation and operation of the new System.
2.3 Cooperation by Incumbent. Incumbent shall fully cooperate with PathNet
and shall provide PathNet with all required assistance in completion of such
obligations in PathNet's performance of its obligations under this Section 2 of
this Schedule A.
2.4 Maintenance of Modifications. Incumbent shall ensure that all
modifications performed pursuant to this Section 2 of this Schedule A are
maintained in accordance with the Specifications, including, but not limited to,
the upgrade or replacement of any equipment and materials described in the
Modifications SOW.
2.5 Choice of Equipment Vendors and Service Providers.
2.5.1 Engagement. In the event Incumbent engages an equipment vendor
or service provider directly in accordance with this Section 2.5 of
Schedule A (i) PathNet shall have the right to approve any equipment
vendors or service providers, which approval shall not be unreasonably
withheld, (ii) all invoices, purchase orders or other bills relating to
such equipment or services shall be sent to both PathNet and Incumbent
A-3
and (iii) Incumbent shall not pay any such invoice, purchase order or xxxx
without the prior approval of PathNet, which approval shall not be
unreasonably withheld.
2.5.2 Approval. Incumbent shall have the right to reasonably approve
any Subcontractor engaged to perform the Services set forth in this
Section 2 of Schedule A.
SECTION 3. DESIGN OF NEW SYSTEM
3.1 Approval of System Design. Within twenty (20) days after receipt by
Incumbent of the System Design from PathNet, Incumbent shall either (i) deliver
to PathNet written approval of such System Design or (ii) deliver to PathNet a
written list of Incumbent's design modifications. PathNet shall review any such
modifications and, incorporate all reasonable modifications into the System
Design. PathNet shall, within thirty (30) days of receipt of Incumbent's
suggested modifications, deliver a revised System Design to Incumbent. In the
event Incumbent fails to deliver to PathNet in writing its approval as set forth
above within the prescribed time period, PathNet shall assume that Incumbent has
approved such System Design.
3.2 Modification of System Design. At any time and from time to time,
PathNet shall have the right to modify the System Design upon written notice and
prior written approval by Incumbent of any material modifications, as new
versions of Equipment used in the System may become available from manufacturers
or software providers, as Technology is improved and as determined by PathNet in
its sole discretion.
3.3 System Technical Specifications. PathNet shall (i) design the System
in accordance with the minimum network performance standards set forth in
Section 3 of this Schedule A, (ii) in each instance where reasonably possible,
use the towers, antennas, waveguide, and other system components of Incumbent's
existing system in the System Design and (iii) design the System to meet the
following technical specifications:
3.3.1 Radio System Design. The active radio components of the System
shall be designed to conform to the Specifications and the manufacturer
specifications set forth in Exhibit A-2 to this Schedule A.
3.3.2 Radio Software Design. The software used to operate the radios
shall conform to the Specifications and the manufacturer specifications
set forth in Exhibit A-2 to this Schedule A.
3.3.3 Antenna and Frequency Specifications. The radio communications
equipment shall transmit and receive on the frequencies as set forth in
the System Design. All antenna reflectors used in the System shall conform
to (i) Category A standards as defined by the FCC and (ii) the
specifications set forth in any PCN relating to the System, and each high
performance antenna shall be fitted with a radome. All antenna mounting
hardware shall meet wind and loading requirements for the applicable
county and shall substantially conform to EIA-222-F.
A-4
3.3.4 Tower Specifications. All towers shall substantially conform
to (i) the EIA/TIA-222-F-1991, Structural Standards for Steel Antenna
Towers and Antenna Supporting Structures, 1996, (ii) EIA/222-F
Specifications for loading for the appropriate county, and (iii) any other
required FCC and FAA rules and regulations.
3.3.5 Waveguide Specifications. Waveguide used in the System
specified for transmission line shall be of a premium grade to ensure
minimum return.
3.3.6 D.C. Power Requirements. The radio components of the System
shall be powered by 48 volts DC with at least eight to ten (8-10) hours of
battery capability (assuming less than 20 amp loads for Incumbent
Equipment), and all necessary chargers, distribution systems and transfer
switches for generators as set forth in Exhibit A-3 to this Schedule A.
3.3.7 A.C. Power Requirements. A.C. electrical power required by the
System shall be consistent with local requirements and the usage at each
of the sites set forth in Schedule B and shall be 120/240 volt single
phase 200 amp service as set forth in Exhibit A-3 to this Schedule A.
3.3.8 Bonding and Grounding Specifications. The System and all
associated electrical components shall be grounded and bonded to current
EIA and IEEE specifications.
3.3.9 Order Wire Specification. Each equipment shelter shall be
equipped with an Order Wire and a handset, which will be used as a talk
circuit for System operation and maintenance purposes and which will be
carried by PathNet as part of the System payload.
3.3.10 Diagnostic Circuit. Each equipment shelter shall be equipped
with a diagnostic circuit that will be used to connect each such shelter
and the Equipment housed in such shelter to the Network Management System.
3.3.11 Multiplexing from OC-3 to DS-1 Level. The System Design shall
provide for any required multiplexing of the OC-3 to the DS-1 level at
each site using an OC-3 Multiplexer.
3.3.12 Multiplexing from DS-1 to DS-0 Level. Within thirty (30) days
after the date hereof, Incumbent shall deliver to PathNet a Schedule
substantially in the form of Exhibit A-4 to this Schedule A setting forth
Incumbent's multiplexing requirements. Upon receipt of such Exhibit A-4 to
this Schedule A, PathNet will reflect in the System Design the requested
multiplexing of the DS-1 to the DS-0 level at each site using a 1/0
Multiplexer subject to limitations in Drop and Insert Capacity between
each Switched Mod Section using available Wayside Channels.
3.3.13 Wayside Channels. Incumbent or PathNet as reflected in the
System Design, as determined by PathNet in its sole discretion, shall use
the Wayside Channels.
A-5
3.3.14 Spectral Loading Requirements. The System shall meet the then
current FCC requirements of spectrum efficiency outlined, 47 C.F.R. 101
and any successor rule or regulation.
3.3.15 Capacity of System. The System shall be comprised of, at a
minimum, 3 DS-3 capability and will have a 1 x n protection switch
allowing for upward migration to a minimum of 1 x 7 protection. The
capacity of the System may be expanded to a 2 x 14 protection level, using
additional spectrum or crossband filters, provided, such Capacity
Expansion does not degrade the System below the performance standards set
forth in this Section 3 of this Schedule A.
3.3.16 SONET Architecture. The digital microwave radios used in the
System shall operate under a SONET format.
3.3.17 Shelters Design. A proposed building layout for the new
shelters to be constructed and the existing shelters to be modified shall
be as set forth in Exhibit A-5 to this Schedule A and shall comply with
all applicable local laws, regulations and ordinances.
3.3.18 Channel Plan. The System shall be designed such that
Incumbent and PathNet shall be allocated capacity as set forth in the
Channel Plan and Section 7.2.2.
3.3.19 Interconnections Limitations. The System shall have no more
than four (4) Interconnections per LATA. No more than two (2) of such
Interconnections shall be to other segments of the PathNet network created
from facilities of other Persons and no more than two (2) of such two
Interconnections shall be to the PSTN. At each Interconnection site, there
shall be no more than two (2) additional antennas used solely for such
Interconnection purposes. Interconnections may be by microwave or other
media. To the extent PathNet develops spurs, PathNet shall specify the
Interconnections at such spurs on Exhibit A-7 to this Schedule A. To the
extent Incumbent develops spurs for its own connectivity purposes,
Incumbent shall specify the Interconnections at such spurs on Exhibit A-8
to this Schedule A.
3.3.20 Protection Switching Requirement. Power, radio, and
multiplexing equipment shall be redundant with automatic protection
switching to minimize Outages as a result of equipment failure.
3.3.21 Generator Requirements. Generators shall be required at all
sites with a history of power outages and all sites that are difficult to
access and shall be the type and size, each as set forth in Exhibit A-3 to
this Schedule A.
3.3.22 System Integration. The System shall be integrated into the
total PathNet telecommunications network as set forth in the System
Design.
3.3.23 Transmission Line Requirements. One (1) or more transmission
lines
A-6
shall be connected to each antenna and such lines will be anchored firmly
to the tower in accordance with the manufacturer's recommendation.
3.3.24 Equipment Rack Specifications. Each equipment rack shall be
firmly anchored to the floor, and the overhead channel iron or the
adjacent racks and shall have the dimensions as forth in Exhibit A-5 to
this Schedule A.
3.3.25 Environmental Control of Shelters. Equipment shelters shall
be environmentally controlled to standards, between 55(degrees) and
80(degrees) and shall be maintained within the desired humidity range, as
set forth in the manufacturer's specifications in Exhibit A-2 to this
Schedule A.
3.3.26 Spurs. The System shall be designed to allow the build-out of
spurs set forth on Exhibit A-7 to this Schedule A from the backbone
network for PathNet's and Incumbent's own network and internal
communications purposes.
3.3.27 Network Management System. The System Design shall include
the Network Management System that complies with the specifications set
forth in Section 7.6 of this Schedule A.
3.3.28 Fuel Tanks and Lines. All liquid petroleum, diesel and
natural gas tanks and lines required shall meet all applicable
environmental and health and safety standards and Requirements of Law.
3.3.29 Pressurizing Equipment. The System Design shall include all
required pressurizing equipment, manifolds and dehydrators.
3.4 System Performance Criteria.
3.4.1 Availability. The System shall be designed to meet or exceed
the long haul objective of 99.98% availability on an annual basis for a
4,000 mile system, which is equivalent to a one way system Outage of less
than 0.4 seconds, per mile, per year.
3.4.2 Circuit Acceptance Level. The System shall be designed such
that any continuous five hundred (500) mile segment of the System during
any consecutive twenty-four hour period shall have no more than one (1)
Errored Second, shall have 99.998% Error Free Seconds and shall have no
Severely Errored Seconds, measured at the DS-1 level.
SECTION 4. INSTALLATION AND CONSTRUCTION
4.1 Documentation.
4.1.1 Project Management Plan, Project Schedule and Cutover Plan.
Upon approval of the System Design, PathNet shall deliver to Incumbent (i)
a plan of the
A-7
respective responsibilities of each Party and other related items relating
to the construction and installation of the System (the "Project
Management Plan"), (ii) a schedule for the installation of the System (the
"Project Schedule"), and (iii) a schedule for the cutover of the System
(the "Cutover Plan"). Incumbent shall have twenty (20) days to either (i)
approve by written notice to PathNet such Project Management Plan, Project
Schedule and Cutover Plan or (ii) deliver to PathNet a written list of
Incumbent's modifications to such Project Management Plan, Project
Schedule and Cutover Plan, as the case may be. PathNet shall review any
such suggested modifications and incorporate all of such suggested
modifications into the Project Management Plan, Project Schedule and
Cutover Plan, respectively. In the event Incumbent does not notify PathNet
in writing of its approval or suggested modifications of the Project
Management Plan, Project Schedule and Cutover Plan as set forth above
within the prescribed time period, PathNet shall assume that Incumbent has
granted such approval.
4.1.2 Installation Reports. After installation has begun and
continuing until Commissioning, PathNet shall provide to Incumbent a
bi-weekly progress report (each a "Progress Report") setting forth, (i) a
description of the work performed during the immediately preceding period,
(ii) a list of any material deviations from the proposed schedule of work
and (iii) an analysis of such deviations with respect to their impact upon
the timely deployment of the System.
4.1.3 Changes to Drawings. In the event that during the process of
Installation any of the Project Drawings delivered pursuant to Section 1.3
of this Schedule A require any modifications, PathNet shall make any such
modifications to such Project Drawings, shall deliver the revised Project
Drawings to Incumbent, and shall place a copy of such revised Project
Drawings at each site.
4.1.4 As-Built Drawings. Upon completion of each phase of
installation as set forth in the Project Schedule, PathNet shall deliver
to Incumbent an as-built drawing of the System (each an "As-Built
Drawing") and shall incorporate the final As-Built Drawing into the
appropriate equipment manuals.
4.2 Installation by PathNet. PathNet or its designated subcontractors
shall construct and install the System as set forth below and in accordance with
this Schedule A and the documents and schedules prepared and delivered pursuant
to this Schedule A.
4.2.1 Radios. PathNet shall recommend and PathNet or its designated
subcontractors the digital radios that meet the Specifications.
4.2.2 Antennas and Frequencies. PathNet shall recommend and PathNet
or its designated subcontractors shall install (i) the antennas that meet
the Specifications and (ii) any required antenna mounting hardware to
secure such antennas to the towers in accordance with the Specifications.
4.2.3 Waveguide Bridge and Supports. PathNet shall recommend and
PathNet or its designated subcontractors shall install (i) waveguides that
meet the
A-8
Specifications, (ii) new waveguide bridges on two faces of the existing
towers and (iii) all additional supports required of the waveguide from
the tower to termination inside the shelter.
4.2.4 Bonding and Grounding. PathNet shall recommend and PathNet or
its designated subcontractors shall install all required ground kits in
accordance with the Specifications, including, but not limited to,
waveguide ground kits at the antenna, the bottom of the tower and at the
entry port of the shelter, tower anchor grounding kits, and ground wire
rings for the shelters.
4.2.5 Moving Company. During installation of the System, PathNet, or
a full service moving and warehousing company hired by PathNet, shall
handle the pick up of necessary equipment for temporary warehousing in all
required areas at and near the installation sites.
4.2.6 Order Wire. PathNet shall recommend and PathNet or its
designated subcontractors shall install an Order Wire at each site in
accordance with the Specifications and shall establish Order Wire
connectivity, including, but not limited to, connectivity to all necessary
external interfaces.
4.2.7 OC-3 Multiplexers. PathNet shall recommend and PathNet or its
designated subcontractors shall install all required OC-3 Multiplexers to
the DS-1 level as set forth in Section 3 of this Schedule A.
4.2.8 Channel Plan. PathNet or its designated subcontractors shall
perform cross-connects of T-1 lines in accordance with the Channel Plan
and the Specifications.
4.2.9 Interconnection Placement. PathNet shall furnish and install
connecting facilities from the System to the PSTN, including but not
limited to connections to POP's of purchasers of Excess Capacity and
PathNet shall furnish and install all cables required to interconnect
project equipment within the System.
4.2.10 Transmission Lines. PathNet shall recommend and PathNet or
its designated subcontractors shall (i) furnish and install all required
transmission lines on the towers, (ii) route such transmission lines to
the equipment racks in the shelters, (iii) connect both ends of such
transmission lines and (iv) interface such transmission lines to the radio
equipment in accordance with the Specifications.
4.2.11 Equipment Racks. PathNet shall recommend and PathNet or its
designated subcontractors shall install all equipment racks necessary for
the Equipment installed by PathNet in accordance with the Specifications.
4.2.12 Network Management System. PathNet shall recommend and
PathNet or its designated subcontractors shall install the Network
Management System, including, but not limited to, all required alarms,
panels, terminals, software and cables at all appropriate demarcation
points in accordance with the Specifications.
A-9
4.2.13 Spurs. PathNet shall recommend and PathNet or its designated
subcontractors shall install all of the necessary equipment to build-out
PathNet's spurs and Incumbent's spurs (as requested and paid for by
Incumbent), each as set forth in Exhibit A-7 to this Schedule A in
accordance with the Specifications.
4.2.14 Deconstruction of Existing System. As required at each site,
PathNet or its designated subcontractors shall move Incumbent's existing
system to one side, providing space for permanent installation of the new
System.
4.2.15 Pre-Commissioning System. PathNet or its designated
subcontractors shall install an "initial" digital System in such a way
that it can be operated and tested without interfering with Incumbent's
existing system performance.
4.2.16 Parallel Systems. In order to minimize system downtime,
PathNet shall provide parallel operations to the Incumbent's existing
analog system with the digital equipment system using new frequencies and
antenna configurations.
4.3 Cooperation During Installation. During installation, Incumbent shall
provide all necessary cooperation to PathNet, including, but not limited to,
posting at each site any Permits or licenses for building or tower work related
to the construction at such site and providing reasonable access to its
Facilities as set forth in Section 5.
4.4 Installation by Incumbent. Incumbent shall furnish and install all
required equipment and materials at each point of demarkation to meet
Incumbent's internal communication needs, including, but not limited to,
furnishing and installing all 1/0 Multiplexers as set forth in Section 3 of this
Schedule A and all other interconnection equipment relating to Incumbent's spurs
set forth in Exhibit A-8 to this Schedule A.
SECTION 5. PRE-COMMISSIONING TESTING
5.1 Factory Acceptance Test.
5.1.1 Tests to be Performed. PathNet shall coordinate all factory
acceptance testing on the Equipment. Such factory acceptance testing shall
include (i) linking together of all racks in each Switched Mod Section to
simulate the System as it will be configured in the field, (ii) testing at
the panel terminal and System level for certification and compliance with
the Specifications, (iii) connecting the radio bays by coaxial cables
through attenuators to simulate "RSL" conditions as encountered in the
field, (iv) testing on a path basis to the applicable configuration of the
System, (v) testing of all miscellaneous Equipment such as supervisory
fault alarm and control and service channel units and (vi) testing the
equipment as a System to resolve all interface problems.
5.1.2 Observing Factory Testing. Incumbent shall have the right, at
its own expense, to witness in person the factory testing of the
Equipment.
A-10
5.2 Rack Test. PathNet or its designated subcontractors shall perform a
rack test once the radio cabinet has been installed.
5.3 Path Test. PathNet or its designated subcontractors shall perform a
path test after each site has been turned up.
5.4 End-To-End Test. PathNet or its designated subcontractors shall
perform an end-to-end test for each Switched Mod Section on the System once all
sites have been turned up.
5.5 Field Test. Once the Equipment is installed and operational, PathNet
or its designated subcontractors shall test each path pursuant to the following
field tests to ensure performance of the Equipment over the designated path in
accordance with the criteria and standards set forth in this Schedule A.
5.5.1 Radio Hop Test: PathNet or its designated subcontractors shall
(i) align all digital microwave paths, (ii) measure and record transmitter
frequency, (iii) measure and record transmitter power, (iv) calculate and
record receiver fade margin, (iv) perform Bit Error Rate checks and (v)
record results of such Bit Error Rate checks.
5.5.2 Digital Multiplex Test: PathNet or its designated
subcontractors shall (i) perform standard loop-back tests and (ii) verify
the performance of all local alarm points to the DS-1 level.
5.5.3 System Test: PathNet or its designated subcontractors shall
(i) perform an end-to-end Bit Error Rate test of the message one radio for
a 24-hour period and an end-to-end Bit Error Rate test of the protect
radio for 1 hour, (ii) verify equipped channel units through microwave
system, (iii) verify performance of Order Wires and Wayside Channels, and
(iv) verify performance of the alarm points function throughout the
System.
5.6 Site Acceptance Testing. PathNet or its designated subcontractors
shall perform all site acceptance tests as recommended by the manufacturers of
the Equipment and PathNet shall provide the results of any such site acceptance
testing to Incumbent promptly after completion of such testing.
5.7 Acceptance Procedure. After completion of site acceptance testing as
set forth in Section 5.6 of this Schedule A, PathNet shall implement the
following acceptance procedure:
5.7.1 Incumbent shall promptly perform an installation inspection
and deliver to PathNet a written list of all material deficiencies from
the Specifications to be corrected by PathNet (the "Deficiency List").
5.7.2 PathNet shall promptly correct such material deficiencies on
the Deficiency List and shall, upon completion, certify to Incumbent that
such items have been corrected.
A-11
5.7.3 PathNet shall submit to Incumbent all of the test data
collected through the performance of the tests set forth in Section 5 of
this Schedule A for Incumbent's approval, which approval shall not be
unreasonably withheld.
5.7.4 Incumbent shall deliver to PathNet a Certificate of Acceptance
substantially in the form of Exhibit A-9 to this Schedule A.
5.8 Equipment Required for Pre-Commissioning Testing. PathNet shall
furnish all Pre-Commissioning Test Equipment.
SECTION 6. CUTOVER
6.1 Cutover.
6.1.1 PathNet Responsibilities. PathNet shall (i) manage the cutover
process for the System, (ii) perform such cutover in accordance with the
Cutover Plan and (iii) notify Incumbent of the circuit activity that will
occur upon Commissioning of each path or Segment and the impact that such
activity may have on the Incumbent's existing system. Promptly after each
site has been cutover, PathNet shall notify Incumbent of the completion of
such cutovers.
6.1.2 Incumbent Responsibilities. Incumbent shall (i) cooperate and
coordinate its cutover of its voice and data circuits with PathNet and the
Cutover Plan, (ii) complete its cutover of its voice and data circuits no
more than ninety (90) days after Commissioning of each path or Segment by
PathNet and (iii) no more than ninety (90) days after cutover by Incumbent
of its voice and data systems, remove all unused equipment from
Incumbent's sites in compliance with all applicable Requirements of Law.
6.2 Station Log Books. PathNet shall establish station logs books in
accordance with all FCC rules and regulations (each a "Station Log Book") and at
Commissioning shall deliver to Incumbent an original of each Station Log Book at
Commissioning.
SECTION 7. SYSTEM OPERATION.
7.1 Increases in Capacity. At any time, and from time to time, PathNet
shall have the right, subject to the terms in Section 7.1.2 of this agreement,
to increase the capacity of the System beyond the capacity created in the
initial build-out; provided, that PathNet fulfills the following conditions
before Commissioning any such proposed Capacity Expansion:
7.1.1 Capacity Expansion Schedule. At least fifteen (15) days prior
to any Capacity Expansion, PathNet shall provide to Incumbent a capacity
expansion schedule (each, a "Capacity Expansion Schedule") setting forth
the amount of capacity to be
A-12
included in such Capacity Expansion, the specific paths to be expanded,
the expansion name (including each path that is affected), and the
expected Commissioning of such Capacity Expansion.
7.1.2 Performance of Capacity Expansion. Prior to the Commissioning
of any Capacity Expansion, (i) PathNet shall perform all required testing
on such Capacity Expansion to confirm that any such Capacity Expansion
will not degrade the System below the Specifications (ii) PathNet shall
provide the results of such testing upon receipt of such test results to
Incumbent for its review and approval and (iii) PathNet shall obtain from
Incumbent a Certificate of Acceptance substantially in the form attached
hereto as Exhibit A-9 to this Schedule A with respect to such Capacity
Expansion.
7.1.3 Incumbent's Right to Contest Capacity Expansion. In the event,
after receipt of the test results as set forth above, Incumbent reasonably
determines that a proposed Capacity Expansion will degrade the System
below the Specifications, Incumbent shall have the right to withhold
delivery of any Certificate of Acceptance with respect to such Capacity
Expansion and shall hire an independent third party approved by PathNet
(which approval shall not be unreasonably withheld) to perform additional
testing on such Capacity Expansion. In the event such independent third
party reports that the proposed Capacity Expansion will not result in the
degradation of the System below the Specifications, Incumbent (i) shall
promptly deliver to PathNet a Certificate of Acceptance with respect to
such proposed Capacity Expansion and (ii) shall pay for the reasonable
costs of such independent third party evaluation. In the event that such
independent third party reports that the proposed Capacity Expansion will
result in the degradation of the System below the Specifications (i)
PathNet shall make all required modifications to the System and the
proposed Capacity Expansion such that, in the opinion of such independent
third party, the proposed Capacity Expansion shall not degrade the System
below the Specifications, (ii) upon verification by such independent third
party that the proposed Capacity Expansion, as modified by PathNet, shall
not degrade the System below the Specifications, Incumbent shall promptly
deliver to PathNet a Certificate of Acceptance substantially in the form
attached as Exhibit A-9 to this Schedule A with respect to such Capacity
Expansion and (iii) PathNet shall pay for the reasonable costs of such
independent third party evaluation.
7.2 Maintenance of System. Within sixty (60) days after the Effective
Date, PathNet and Incumbent shall execute and deliver the Maintenance Services
Agreement. PathNet shall have the right to supplement at its own expense at any
time, and from time to time, any maintenance performed on the System, as
determined by PathNet in its sole discretion.
7.3 Additional Transmission Lines and Antennas. After Commissioning, if
the System is expanded pursuant to any Capacity Expansion, PathNet shall have
the right to elect to install a second transmission feed line or a third antenna
to any tower. In such instance, PathNet shall (i) perform any tower analysis
that may be required before the installation of such transmission line or
antenna, (ii) furnish and install such additional transmission line and any
associated connectors and mounting hardware for securing such transmission line
to the towers, (iii) furnish and install such antenna and other devices and
equipment associated with such
A-13
antenna and (iv) perform strengthening to the tower required for such
transmission line or third antenna.
7.4 Additional Order Wires and Diagnostic Circuits. At any time and from
time to time, PathNet shall have the right to install additional Order Wires and
diagnostic circuits at System sites, which Order Wires and diagnostic circuit
may or may not be carried as part of the System payload as determined to be
necessary or appropriate by PathNet in its sole discretion.
7.5 24-Hour Network Monitoring Center. Upon Commissioning and for the
period thereafter until the Expiration Date, PathNet shall operate a network
monitoring center (the "Network Monitoring Center") twenty-four (24) hours a
day, seven (7) days a week, which Network Monitoring Center shall, among other
things, handle all problems and trouble reports that may arise and monitor the
System as set forth in Section 7.6 of this Schedule A.
7.6 Network Management System. At all times after Commissioning until the
Expiration Date, PathNet shall provide a network management system to be
operated at the Network Monitoring Center (the "Network Management System")
which Network Management System will (i) manage all network elements within the
System (21 SMX or equivalent), (ii) monitor and control the facilities system,
the radio system, and the OC-3/DS-1 multiplex system, (iii) collect performance
data such as Errored Seconds, Severely Errored Seconds, frame loss and Failed
Seconds consistent with the manufacturer's specifications set forth in Exhibit
A-2 to this Schedule A, (iv) monitor the shelter environments (including
commercial power failure, door alarms, charger failures, low waveguide pressure,
air conditioner failure, tower light alarms, generator runs (if any), waveguide
dehydrator excessive runs, smoke alarms, high temperature and low temperature),
radio equipment, multiplexing equipment, and Incumbent equipment (as reasonably
requested by Incumbent) and (v) provide Incumbent with the ability to monitor
the System separately from the overall PathNet network.
7.7 Alarm and Event Logging and Reports. Within thirty (30) days after the
end of each calendar quarter, PathNet shall provide to Incumbent a report (each
an "Alarm and Event Report") setting forth a log of all alarms and events
recorded by the Network Management System.
7.8 System Outages. Each Party shall use its best efforts to avoid
unscheduled System Outages in the performance of each Party's respective rights
and obligations under this Agreement.
7.9 Replacement of Radios. Beginning in the fifteenth (15th) year after
Commissioning, PathNet shall begin replacing the radios and radio software
relating to the System and shall replace such radios and radio software at an
average rate of ten percent (10%) a year for ten (10) years.
7.10 Network Loops. In the event in the construction of the PathNet
network a network loop is created relating to the System, PathNet shall
facilitate allowing Incumbent to benefit from the existence of such network loop
in the event of a System Outage.
A-14
SECTION 8. GENERAL
8.1 Access to Sites. In addition to any access rights relating to the
Facilities set forth in Section 5 of the Agreement, Incumbent shall provide upon
the reasonable request of PathNet, access for all construction vehicles, which
access may involve the construction by Incumbent of additional roads and paths.
8.2 Parking at Sites. At the request of PathNet, Incumbent shall provide
for vehicular parking at each site at no charge to PathNet for use during the
term of this Agreement; provided, however, in the event sites are located in
urban areas where vehicles are parked in privately operated lots or garages,
PathNet shall be responsible for any and all parking charges at such urban
sites.
8.3 Use of Telecommunications Devices. While visiting Incumbent's sites,
Incumbent shall allow PathNet to use existing telephone lines or Order Wires in
connection with PathNet's performance of its rights and obligations under this
Agreement.
8.4 Fuel Tanks. Incumbent shall ensure that all liquid petroleum tanks are
adequately supplied throughout the term of this Agreement.
8.5 Retaining of Records. All records and reports required pursuant to
this Schedule A, shall be retained by PathNet or Incumbent, as the case may be,
for at least five (5) years or any longer period as may be required by law.
8.6 Work Permits. Incumbent shall obtain all necessary local, state and
Federal permits as required to perform all of the services set forth in this
Agreement.
8.7 Hazardous Material.
8.7.1 Existence of Hazardous Material. Without the written consent
of Incumbent as described below, PathNet shall not bring or cause or
permit, knowingly or unknowingly, any Hazardous Material to be brought or
remain upon, kept, used discharged, leaked or emitted on any of
Incumbent's sites or Facilities.
8.7.2 Compliance with Environmental Laws. In the event that
Incumbent allows PathNet to bring Hazardous Materials to Incumbent's sites
as set forth in the Environmental Audit, PathNet shall strictly obey and
adhere to any and all Federal, state or local laws, ordinances, orders,
rules, regulations, codes or any other government restrictions or
requirements (including, but not limited to, CERCLA and RCRA) which in any
way regulates, governs, or impacts PathNet's possession, use, storage,
treatment or disposal of such Hazardous Material.
8.8 Transportation. PathNet shall provide transportation for all PathNet
personnel or Subcontractors to each of Incumbents sites and between such sites
in connection with the performance of the Services.
A-15
8.9 Storage. Incumbent shall provide at no charge to PathNet or any vendor
providing materials for use in the System, secure and appropriate storage for
all equipment and materials to be installed or used for the installation,
testing or operation of the System, which storage facilities shall also serve as
the drop-ship point for staging all installation equipment used in the System.
8.10 Unpacking and Trash Removal. PathNet shall (i) unpack all crates and
boxes, (ii) remove all trash created by such unpacking from Incumbent's sites
and (iii) verify all packing lists. Incumbent shall regularly remove all other
trash from its sites and Facilities.
8.11 Manufacturing and Ordering of Equipment. As the System is installed
or upgraded after Commissioning, PathNet shall order all required equipment and
materials, including, but not limited to, all required installation materials,
from the respective manufacturers in accordance with the timing set forth in the
Project Schedule.
8.12 Ship and Delivery Schedules. At least two (2) weeks prior to receipt
of any equipment or materials to be used in the modifications or installation
set forth in Section 2 and Section 4 to this Schedule A, respectively, PathNet
shall provide to Incumbent detailed ship and delivery schedules relating to such
equipment and materials.
8.13 Electricity. Incumbent shall provide all required electricity for the
design, modification, installation, operation and monitoring of the System in
accordance with the specifications set forth in Exhibit A-3 to this Schedule A.
X-00
XXXXXXX X-0
EQUIPMENT
SYSTEM EQUIPMENT, TOWERS AND SHELTERS
Type of Equipment Quantity
----------------- --------
Towers: 0
Buildings: 34
Generators: 24 (includes 3 portable)
DC Charger Systems: 40
Battery Plants: 40
Antennas: 148
Waveguide: 35,246 feet
NEC 2000 SONET Radios: 148 TRR's
NEC 2600 Digital Radios: 0
OC-3 Multiplexers: 22 Shelves
CoastCom T1 Multiplex 45 Shelves
Note: California Microwave Model SST 1 are to be installed at CS-13 and Welcome,
Minnesota sites. All other radios are NEC 2000.
X-00
XXXXXXX X-0
MANUFACTURERS SPECIFICATIONS FOR RADIOS
NEC OC-3 MULTIPLEXER SPECIFICATIONS
IMT-150
---------------------------------------------------------------------------------------------
Power
Physical: Requirements: Interface: Features:
---------------------------------------------------------------------------------------------
Mounts in a 23-inch -48 volts DC High Speed: OC-3 Software Provisioning
EIA rack Approximately 125 Optical Full Bandwidth Time
Height 11.4 inches xxxxx (ADM Low Speed: OC-1, Slot Assignment
Width 21.4 inches configuraton) XXX-0, XX0, xx XX0 X.00 Xxxxxxx for OSS
Depth 10 inches DS1 PM Monitoring
Capability
---------------------------------------------------------------------------------------------
NEC 2000 SERIES
Specifications:
Physical:
One cabinet (600 mm wide, 300 mm deep and 2.2 m high) for 4 radio channels
(Includes OC-3 interface per channel, space diversity receiver, order wire and
wayside DS1 interface, and 1:N switch).
Power Requirements:
-24 or -48 volts DC
Approximately 200 xxxxx per radio channel for a terminal configuration
Approximately 150 xxxxx per radio channel direction (1 TRR) for a repeater
configuration
Interface:
OC-3
Operating Specifications:
Frequency Band: 5.945 to 6.425 GHz
Modulation: 128 QAM MLCM
Capacity: 155.52 Mb/s plus radio overhead (Wayside DS1, Order Wires, ATPC
signals, 1:N commands, monitoring)
Transmit Power at interface to transmit waveguide: +29.7 dBm
A-18
System Gain (Waveguide interface to waveguide interface - no ATPC): 101.1 dB
System Gain (Waveguide interface to waveguide interface - with ATPC): 103.1 dB
Dispersive Fade Margin (10^-3): 48 dB
FCC Identifier: BSF6P155-S02A
Emission Designator: 30M0D7W
Nec 2600 Series Digital Microwave Radio Specifications
Models Available:
8 DS-1: 6G13MB
12 DS-1: 6G19MB
16 DS-1: 6G26MB
32 DS-1: 6G52MB
Physical:
One Hot-Standby with Space Diversity receiver (2 TRR) Subsystem is 482 mm (19")
Wide by 798.5 mm (31.5") High weighing 75 lbs. A total of two (2) HSB systems
for a repeater or a terminal 3:1 multiline system (4 TRR) will fit in a standard
19" by 7' 6" Rack.
Power Requirements:
-24 or -48 volts DC
Approximately 130 xxxxx per HSB radio system (2 TRR)
Approximately 150 xxxxx per HSB radio system for 32 DS-1 model.
System Configuration Options:
The following system configurations are available for 8, 12, 16, or 32 DS-1
capacity systems:
HS/HS=Hot Standby Transmitter and Hot Standby Receiver (2 TR)
HS/SD=Hot Standby Transmitter and Space Diversity Receiver (2 TR)
1+0/SD=Single Transmitter with Space Diversity Receiver (1 TRR)
1+0=Single Transmitter and Single Receiver (1 TR)
Features:
Automatic Transmit Power Control (ATPC)
Can be site configured for a Terminal or Regenerative Repeater with any
channel drop and insert capabilities.
Forward Error Correction (FEC)
Decision Feedback Equalizer (DFE) for fading countermeasures.
In-Service capacity upgrades.
Two (2) VF Orderwire channels Per Radio
One (1) Data channel up to 9.6Kbs
Operating Specifications:
Frequency Band: 5.925 to 6.425 Ghz or 6.525 to 6.825 Ghz
Modulation: 128 QAM
Transmit Power at Interface to waveguide: +30 dBm
A-19
--------------------------------------------------------------------------------
8 DS-1 12 DS-1 16 XX-0 00 XX-0
--------------------------------------------------------------------------------
System Gain: 106.0 dB 104.0 dB 103.0 dB 100.0 dB
--------------------------------------------------------------------------------
Receiver Threshold:
(BER 10^-6) -80.0 dBm -78.0 dBm -77.0 dBm -74.0 dBm
--------------------------------------------------------------------------------
Dispersive Fade
margin: (BER 10^-6) 64.0 dB 63.0 dB 62.0 dB 59.0 dB
--------------------------------------------------------------------------------
Emission Designator: 10MOD7W 50MOD7W 3M7507W 2M50D7W
--------------------------------------------------------------------------------
FCC Identifier: BSF89N6P52-S BSF89N6P26-S BSF89N6P19-S BSF89N6P7-S
--------------------------------------------------------------------------------
X-00
XXXXXXX X-0
ELECTRICITY AND POWER SPECIFICATIONS OF THE SYSTEM
DC POWER SPECIFICATIONS
Site Configuration Radio Mux Chan bank Incumbent Site Total Site Total Battery Size
7:1(Xxxxx) OC-3(Xxxxx) (Xxxxx) Equip(Xxxxx) XXXXX XX AMPS 10 Hour Reserve
Terminal End 1:3 800 330 250 720 2,100 44 Amps 440 AH
Terminal End 1:7 1,600 770 250 720 3,340 70 Amps 700 AH
Repeater 1:3 1,200 None 250 720 2,170 45 Amps 530 AH
Repeater 1:7 2,400 None 250 720 3,370 70 Amps 000 XX
0 Xxx Xxxxxxxx 1:3 1,600 125 250 720 2,695 56 Amps 000 XX
0 Xxx Xxxxxxxx 1:7 3,200 125 250 720 4,295 90 Amps 900 AH
AC POWER SPECIFICATIONS
DC Heat & Air Total Total
Site Configuration Chargers Conditioning Lights Miscellaneous AC WattsAC Amps @ 220 VAC
Terminal End Nominal 3,696 3,000 300 1,500 8,496 39
Terminal End Maximum 8,712 6,000 1,600 2,800 19,112 87
Repeater Nominal 3,696 4,500 300 1,500 9,996 45
Repeater Maximum 8,712 9,000 1,600 2,800 22,112 000
0 Xxx Xxxxxxxx Nominal 4,752 6,000 500 1,800 13,052 59
2 Way Junction Maximum 8,712 12,000 2,000 3,200 2,512 118
Note: All New Shelters are AC equipped for 000 Xxxx, xxxxxx xxxxx, 000XXX
Service
X-00
XXXXXXX X-0
INITIAL INCUMBENT CHANNEL PLAN
INITIAL DS-1 REQUIREMENTS
Site Name DS-1's Wired DS-1's Equipped
--------- ------------ ---------------
Monchy [***] [***]
Crow Creek [***] [***]
CS 1 [***] [***]
Porcupine [***] [***]
East Fork [***] [***]
Glasgow [***] [***]
CS 2 [***] [***]
Hay Creek [***] [***]
CS 3 [***] [***]
Hardscrabble [***] [***]
CS 4 [***] [***]
Grassy Butte [***] [***]
CS 5 [***] [***]
Xxxxx Butte [***] [***]
Elm Creek [***] [***]
CS 6 [***] [***]
Xxxxxx [***] [***]
Mandan [***] [***]
CS 7 [***] [***]
Xxxxxx [***] [***]
CS 8 [***] [***]
Ashley [***] [***]
Long Lake [***] [***]
CS 9 [***] [***]
Aberdeen [***] [***]
CS 10 [***] [***]
Garden City [***] [***]
Codington [***] [***]
CS 11 [***] [***]
Brookings [***] [***]
Lake Shaokatan [***] [***]
Lake Stay [***] [***]
CS 12 [***] [***]
Xxxxxxx [***] [***]
CS 13 [***] [***]
Welcome [***] [***]
East Chain [***] [***]
Crystal Lake [***] [***]
Ventura [***] [***]
X-00
XXXXXXX X-0
EQUIPMENT SHELTERS SPECIFICATIONS AND DESIGN
1. Summary
This "Equipment Shelter Specification" applies to concrete pre-cast,
pre-equipped, transportable equipment shelters for use in conjunction with
equipment installed by PathNet, Inc. and covers material and workmanship
standards. This document is designed to assist the user in defining your
specific equipment shelter requirements. The shelter must be designed for the
explicit purpose of housing electronic equipment, fiberoptics equipment,
measuring devices and other related components, within a controlled environment
required for the proper operating conditions for the equipment. The shelter
manufacturer must adhere to compliance with all national building codes. All
shelters will be assumed to be placed within ten (10) feet of the base of the
tower.
2. Foundation
The shelter shall be designed for any of the following foundation types:
o Pier & Beam
o Slab
o Perimeter Beam
3. Shelter Type
The shelter shall be constructed of pre-cast, pre-assembled Portland concrete
and shall be manufactured in a controlled environment.
4. Shelter Size
The shelter should conform to the following dimensions unless otherwise noted:
o One room shelter (no generator) - 12' X 20' OD
o Two room shelter (equipment room and generator room) - 12' X 28' OD
5. Operating Environment
5.1. Temperature
The optimum operating temperature of the equipment to be installed is 75
degrees F (24 degrees C) unless otherwise specified by PathNet.
5.2. HVAC
The heating and cooling requirements for a shelter are based upon the
outside maximum and minimum temperature expected for the shelter location
and the equipment heat
A-23
output specified by PathNet. Typical heat load values are 12,000 to 18,000
BTU/HR. Design heat loads for specific shelters will be provided by
Pathnet. Two wall-mounted air conditioners are required. The units are to
be sized so that one unit will maintain an interior temperature of 75
degrees F with the highest exterior temperature expected for shelter
location.
6. Hardware
All external hardware will be galvanized or coated to protect against corrosion.
7. Structural
Structural design and manufacturing shall conform to ACI 318-89 requirements.
7.1. Floor
The floor section shall be constructed of 8" waffled structural pre-cast
concrete. The ribs shall be 2'-0" O.C. transverse and 4'-0" O.C
longitudinal. All surfaces shall be smooth. The interior surface shall be
covered with 1/8" X 12" X 12" square vinyl floor covering, bonded with a
waterproof contact adhesive.
7.2. Roof
The roof section shall be constructed of pre-cast concrete with 1/4" per
foot drainage slope. The ceiling insulation and finish shall be foamboard
insulation with 3/8" vinyl coated board. All joints will be covered by
plastic joint or corner trim. The roof section shall provide a 2" overhang
on all sides. The roof will be a hip type sloping in 4 directions. It
shall be constructed as a cap and should fit over the walls, leaving no
exposed roof-to-wall joint.
7.3. Wall
The wall section shall be constructed of 4" solid concrete, cast in one
piece to minimize joints, with an exposed aggregate exterior finish and
capable of withstanding gun fire from a 30.06 at 50 feet. The wall
insulation and finish shall be foamboard insulation with 1/2" vinyl coated
board. All joints will be covered by plastic joint or corner trim. All
floor/wall intersections will be finished with 4" vinyl baseboard. There
will be no exposed wall-to-floor joint.
8. Thermal
Standard wall and ceiling thickness shall be 1" foamboard insulation. The
calculated system value is R9.6 with 4" thick lightweight concrete walls/roof
sections, 1" foamboard insulation covered by 1/2" fiberglass reinforced plastic
surfaced board. (Thicker insulation and higher R-values must be specified
according to the locality.)
9. Concrete
All sections must be constructed of concrete with a compressive strength of 3000
PSI at 28 days.
A-24
9.1. Cement Type
Cement used in concrete shall be standard Portland cement conforming to
the requirements of the "Standard Specifications for Portland Cement",
ASTM Designation C150.
9.2. Mix
The mix design shall be 114-118 lbs./cu. ft. structural lightweight
concrete using expanded shale or expanded clay aggregate and shall be
homogeneous. Seeding of aggregates for exposed aggregate finish is not
allowed.
Water will be free from injurious quantities of oil, alkali, vegetable
matter and salt. Non-potable water shall not be used in mixing concrete.
9.3. Concrete Standards
Concrete aggregates will conform to one of the following standards:
o Specifications for Concrete Aggregates (ASTM Designation: C33)
o Specifications for Lightweight Aggregates for Structural Concrete
o (ASTM Designation: C330)
9.4. Reinforcement
Reinforcement bars shall be deformed steel bars conforming to the
requirements of the "Specifications for Deformed and Plain Billet-Steel
Bars for Concrete Reinforcement," ASTM Designation: A615. Welded smooth
wire fabric shall be steel wire fabric conforming to the "Specifications
for Welded Steel Wire Fabric for Concrete Reinforcement", ASTM
Designation: A185.
10. Sealing
o The shelter shall be sealed to resist dust and water infiltration.
o All joints shall be sealed with a compressible resilient sealant.
o There shall be no exposed roof-to-wall or wall-to-floor joints.
o Exterior surfaces of walls and roof shall be sealed with two (2) coats of
Thoroglaze H Sealer, or acceptable equivalent unless otherwise noted.
11. Door
11.1. Door Construction
The door shall be 3' X 7' X 3/4", 18 gauge galvanized steel, insulated
(minimum R12), primed, painted and installed flush with the door check,
door stop, weather stripping, mortise lockset and stainless steel ball
bearing hinges.
11.2. Door Frame
The doorframe shall be of at least 16 gauge galvanized steel, primed,
painted and cast into the wall panel.
A-25
11.3. Door Locks
All doors shall have a deadbolt locking mechanism with a minimum 1" throw
and an anti-pick lock guard.
12. Structural Loading
12.1. Floor
A minimum of 140 lbs. per sq. ft. as defined in "Uniform Distributed
Load," ASCE 7-88. The battery area should be reinforced to support 5000
lbs. per battery rack. The battery area will be shown on the floor plan.
12.2. Roof
A minimum of 50 lbs. per sq. ft. as defined in "Roof Snow Load
Specification," ASCE 7-88.
12.3. Wind
A minimum of 115 MPH as defined in "Basic Wind Speed Specifications," ASCE
7-88.
12.4. Earthquake
Shelters shall be designed for the most stringent earthquake rating
conditions as defined in ASCE 7-88, Zone 4.
13. Electrical System
Electrical installation and wiring shall conform to the latest edition of the
National Electrical Code (NEC) and shall consist of the following as a minimum:
13.1. Minimum Requirements
o 200 Amp, 220 VAC Single Phase Main
o 200 Amp Manual Transfer Switch
o 200 Amp Generator Interface
o Forty (40) Position Breaker Box (With 32 single pole, 20 Amp
breakers.)
o 120/240VAC 3-Wire Arrester With Alarms (65kVA Peak Capacity)
o Surface Mounted EMT Conduit
o Grounded Duplex Outlets (One every 4 ft. on 3 walls.)
o Four (4) Fluorescent Lights (2 bulb fixtures with
inside switch mounted by door.)
o Incandescent Porch Light (With 0-30 minute timer)
13.2. Surge
Arresters An interior-mounted surge arrester is designed to protect
against transients caused by lightning or power switching surges. Primary
arresters protect the building's electrical components and are
automatically restored following activation due to a surge. It should be
installed across the main breaker on the line side unless otherwise
specified by PathNet. Secondary arresters protect individual branch
circuits. Visual inspection is required to determine whether the arrester
must be replaced following a surge.
A-26
14. Grounding
A halo ground system should consist of at least a #2 AWG green insulated
stranded copper wire mounted around the perimeter of the interior wall just
below the ceiling. A 1/4" X 4" X 24" copper ground bar should be located
externally just below each waveguide entry plate. A #2 AWG green insulated
copper jumper should be used to bond the ground bar to the exterior halo ring.
Bonding on either interior or exterior grounding systems will be clean of dirt
and corrosion and applied with non-oxidizing grease.
14.1. Interior Halo Grounding
All cable ladder, racks, lights, equipment and exterior ground are to be
bonded to an interior halo grounding system.
The following items are required for halo grounding:
o #2 Green Insulated Stranded Copper Halo
o One (1) Master Ground Bar 1/4" X 4" X 24"
o Four (4) #2 Tinned Solid Copper Drops with 10' Pigtails
o Eight (8) #2 Green Insulated Stranded Copper Equipment Ground Drops
14.2. External Ground System
An exterior halo ring is required and will be bonded to the interior halo
grounding system with 8' pigtails listed above.
14.3. Conduit Grounding
All conduit, conduit couplings, light fixtures, junction boxes and service
equipment shall be grounded with mechanical clamps to electrically bond
the conduit. The bonding wire will be a minimum #10 AWG green insulated
copper wire for all except light fixtures. The minimum for light fixtures
is #12 AWG green insulated copper wire.
15. Waveguide Entrance
The shelter will have two 8 port waveguide entry panels and two blank panels
located on opposite walls. Two waveguide entry panels will be installed on one
wall and two blank panels mounted on the opposite wall. PathNet will define the
location of the waveguide entry panels. Each waveguide port shall have a minimum
interior diameter of 4 inches.
16. Alarms
The shelter will have general housekeeping alarms wired to a central location
associated with the following:
o Door Open
o Smoke Detection
o AC Electrical Fail (sense before manual or automatic transfer switch)
o Surge Protector Fail
o Air-conditioning Fail
o High Temperature
o Low Temperature
A-27
o Charger Fail
o Breaker Alarm
o Fuse Alarm
o Low Waveguide pressure
o Dehydrator excess run alarm
o Generator Fail
o Generator Run
X-00
XXXXXXX X-0
GROUNDING AND LIGHTNING PROTECTION GUIDELINES AND SPECIFICATIONS FOR
COMMUNICATIONS SHELTERS
Preface
An effective ground system for a communications equipment shelter is necessary
to ensure protection of personnel and equipment when a fault occurs. The ground
system limits excessive voltages from various electrical conditions such as
lightning and utility switching, and contributes to superior performance of the
electronic equipment by reducing noise induction.
1. Grounding Introduction
Communications equipment shelters are subject to electrical noise and
high-voltage surges. These transients occur predominantly in the common mode
(line to ground), and are typically caused by lightning or power switching.
1.1. Lightning
When lightning induced surges appear at the point of connection to a
building (the service entrance), a high common mode potential is generated
between the current carrying conductors and ground. This potential
produces a flow of current that seeks a path to earth to complete the
circuit.
Lightning can easily induce a 3000-ampere transient into a power line.
When this transient reaches a building, the building ground at the service
entrance can rise to 60,000 volts (assuming a building earth resistance of
20 ohms). The reference potential for ground in the rest of the building
would rise proportionately.
In order to protect the building against these high voltage surges, it is
important to establish a low resistance earth ground at the service
entrance. The National Electrical Code (Article 250, Part 4) specifies
that the grounding at a building's service entrance should have a
resistance to ground of 25 ohms or less. The IEEE Green Book (Recommended
Practice for Grounding, ANSI/IEEE Standard 142-1982) recommends that the
ground resistance be less than 5 ohms. If the building contains highly
sensitive electronic communications equipment, a ground resistance of 5
ohms or less is recommended if this value can be practically achieved with
the given site conditions.
1.2. Types of Grounding
There are two major types of grounding that should be considered when
designing an electrical system: power distribution system grounding and
telecommunications equipment grounding.
A-29
1.2.1. Power Distribution System Grounding
The power distribution system pertains to the incoming AC service,
service entrance equipment, power panels, and electrical conductors
providing the power to various electrical/mechanical equipment.
Grounding of the power distribution system is essential to:
o protect occupants from exposure to dangerous shock voltage
o provide a path for ground fault current
o limit excessive voltages due to lightning or utility switching
Typical grounding components for the power distribution system
include:
o grounding electrode at the service entrance
o ground bus in the power panel
o ground lugs in the other service entrance equipment such as
the safety disconnect or transfer switch
o third wire grounding conductor for all the electrical
equipment
o lightning and surge arresters.
1.2.2. Telecommunications Equipment Grounding
Electronic equipment such as radio systems, telephone switches,
battery chargers and rectifiers, uninterrupted power supply (UPS)
equipment, and any other equipment that encloses or is adjacent to
energized conductors require additional grounding. This sensitive
electronic equipment must be protected from the following:
o excessive transients caused by lightning or utility switching
o degraded performance due to electromagnetic noise
Equipment grounding frequently utilizes a ground ring encircling the
interior of the shelter (halo ground ring). Ground lugs attached to
the various equipment housings and racks are connected to the ground
ring. Ground bars at the waveguide entry and at each section of the
cable ladder are also tied to the ground ring. Multiple external
drops connect the internal ground ring to the exterior site ground
ring.
2. Grounding Practices
2.1. The Grounding Conductor
In order to reduce inductance and surge voltages in a power distribution
system, a ground path for protected devices should be provided. One method
is to rely upon the conduit system to carry these transient currents. This
is allowed by the National Electrical Code in Article 250-91 (b). The best
method, however, is to include an extra conductor in the
A-30
same conduit or raceway as the current carrying conductor. The grounding
conductor should extend to the ground connection in the service entrance
equipment.
2.2. Equipment Ground Wires
When lightning strikes, it takes the path of least impedance (resistance
and inductance). Cable bends increase inductance. Therefore, equipment
ground wires should be large, and run straight for minimum inductance and
voltage drop. The recommended bending radius is 6" when bends are
unavoidable. Equipment ground wires should be separated from all other
conductors, and should not be run through metal conduit unless the conduit
and ground wires are bonded at both ends.
2.3. Bonding
Even when the ground to earth connection's impedance of the service
entrance is minimized and grounding conductors are used in the feeder and
branch circuits, high transient voltages can still occur in the power
distribution system as a result of utility power switching. An effective
method of limiting this noise (especially common mode voltage
differentials) is to bond all the equipment ground wires to a halo ground
system that is connected to the site ground system and power distribution
system ground.
Bonding is the connection of all potential ground conductors (including
racks, frames, cable ladder, conduits, metal enclosures, and exposed
metallic members of the building structure) to each other. Bonding does
not eliminate voltage drops since transient currents will continue to take
the path of least inductance. However, the current is sufficiently
distributed throughout the bonded system to reduce the voltage gradients
in any area to levels that prevent personal injury or equipment damage.
Proper bonding procedures produce cross connections of all equipment and
structures. It provides many paths to ground from any one point. Since the
bonded ground network does not form a part of the normal electrical power
path, multiple inductive loops are not a concern. Only transient or fault
currents can flow in the ground network.
In addition to preventing the development of voltage gradients, cross
connection reduces the system's susceptibility to high frequency noise.
Since all conductors have some impedance, resonance will occur at some
frequencies. At those frequencies, the impedance of the grounding
conductor may be very high, and allow noise currents to develop increased
voltage drops. By bonding the ground network, however, there may be other
conductors nearby that are not resonating, and a low impedance path for
the noise signal can be maintained.
2.4. Faraday Cage
A Faraday cage provides an EMI shield to further reduce noise. The cage
usually consists of multiple conductors in a box like configuration. A
halo ground system with multiple down conductors can act as a quasi
Faraday cage, and give some low frequency shielding.
A-31
When lightning hits the tower, the tower will pass the current to ground
and radiate RF energy. A Faraday cage can reduce this energy by adding
distance (as seen by the magnetic field) between the tower and the
equipment shelter. The steel reinforcing in the concrete shelter walls can
form a highly effective Faraday cage if bonded to the grounding system.
The amount of shielding depends on the size and spacing of the welded wire
fabric. Additionally, all rebar must be bonded together.
2.5. Site Ground System
When a tower is struck by lightning, equipotential voltage rings form
around the tower until the energy is diffused into the surrounding ground
soil via the grounding system.
The tower ground ring will disperse the energy away from the tower base or
guy wires. The ground rods will transfer the energy deeper into more
conductive soil layers. This is important to keep lightning surges out of
the equipment shelter. Unless the energy is properly dispersed into the
soil, the voltage will build up in the tower, and attempt to go to
another, less desirable path.
The equipment shelter is protected by a perimeter ground system that forms
an equipotential plane. Also, ground rods should be driven into the soil
at the following points:
o each corner of the shelter
o the service entrance
o the waveguide entry port
o each external halo ground drop
o every 10' (or less) along the exterior ground ring
The shelter ground ring system should have a connection to the tower
ground system just below the coaxial cable runs. A second connection
between the two ground systems should be installed for redundancy. All
metal work (waveguide bridge and supporting posts) should be bonded to the
ring/radial ground system.
2.6. Grounding System Performance Check
Test the original installation periodically to determine whether
resistance is remaining constant or is increasing. An increase in
resistance can be caused by several factors.
In lower conductive soils, high electric fields can develop at the ends of
the ground rods, which can cause arcing in the soil. This arcing can cause
glassification around the rods, beginning at the tip, and working its way
upward. This glassification of the silica in the soil acts as an
insulator, severely impairing the grounding characteristics of the rod. If
resistance increases over time to an undesirable level, reduce the
resistance by adding electrodes or chemically treating the soil to
increase moisture content.
A-32
3. Computing Resistance to Ground
3.1. Resistance to Earth
The resistance of a grounding electrode is dependent on the:
o resistance of the electrode,
o contact resistance between the electrode and the soil, and
o resistance of the soil from the electrode surface outward as
described by the geometry set up by the flow of current from the
electrode to infinite earth.
The first two resistances are negligible, and can be disregarded. The
third resistance is larger and must be considered.
Around a ground rod this resistance is the sum of the series resistances
of virtual shells of earth, located progressively outward from the rod.
The shell nearest the rod has the smallest circumferential area or cross
section, so it has the highest resistance. Each successive shell has
progressively larger areas, and thus, progressively lower resistances. For
an 8-foot ground rod, the incremental increase in resistance decreases to
nearly zero when the rods are spaced 16 feet apart. Therefore, when using
multiple ground rods, the optimal spacing between rods should be double
the length of the rod.
3.2. Resistance Calculations
When computing resistance to ground, treat the tower grounding and the
shelter grounding as two separate systems. Within each of these two
systems are two subsystems. The shelter has a grounding ring and the
grounding rods. The tower has a grounding ring, grounding rods, and
occasionally, grounding radials.
The IEEE Green Book provides several formulas for calculating the
resistance to ground for several different systems.
4. Typical Grounding Configurations
Several options are available when deciding on a ground system for a
communication shelter, depending upon the soil conditions and thunderstorm
activity of a particular site. The U.S. Weather Bureau publishes an isoplethic
map of the United States showing the average number of days each year on which
thunderstorms occur. Any area with an isoplethic level above 90 should be
considered a high-risk area, and serious consideration should be given to
providing a more stringent grounding system.
4.1. Ground Bar System
In shelters where very little lightning protection is needed, a simple
ground bar system can be used. A system of this type would consist of a
single copper ground bar located under the waveguide port, telephone
entry, or both, with an external drop to be connected to the external
ground system. Transmission lines should be grounded to this ground bar.
A-33
4.2. Halo Ground System
PathNet shelters will use a halo ground system. This system includes a #2
AWG copper wire completely encircling the equipment room. The halo is
located 3 to 6 inches below the ceiling. External drops are located at
each corner of the shelter. Wall penetrations should be angled at 45
degrees to minimize bending.
4.3. External Ground System
The external ground system for all shelters consists of ground rods placed
at each corner of the shelter and 10' intervals along the ground ring,
below the waveguide entry, and at the AC service entrance. The rods should
be exothermically welded to a perimeter ground ring of #2 AWG solid tinned
copper wire. (Tinned copper is recommended to reduce corrosion of the
wire). The wire should be buried below the frost line (minimum 30", deep
per NEC Sec 250-8(d)), and at least 24", away (measured horizontally) from
the foundation. The ground ring should be bonded to the tower ground
system at two locations, to the externally mounted ground bars under the
waveguide ports and to the AC service ground as close as possible to the
service entrance.
5. General Specifications
This section covers grounding and lightning protection of pre-cast,
pre-equipped, and transportable equipment shelters. It establishes minimum
standards for grounding of all PathNet Equipment Shelters, and provides
standards for additional customer grounding options.
5.1. General Guidelines
5.1.1 Workmanship
Equipment grounding wire conductor runs will be as short and
straight as possible. All equipment and bonding grounding conductors
will have radii bends 6" or greater.
5.1.2. Design
Where possible, the AC service entrance, waveguide entry port, and
telephone line entry will all be located in close proximity to each
other, and their associated grounding systems will be bonded
together.
5.1.3. Connections
Unless specified otherwise, minimum connection requirements will be
of the mechanical type made with a crimp type connector. A one hole
copper ground lug will be used for equipment connections. An
oxidizing preventative compound will be applied to all mechanical
connections, and paint will be removed as necessary to insure
positive bonding of all grounded equipment.
A-34
All external, buried connections will be of the exothermically
welded type. These include, but are not limited to, halo drops to
ground rod, buried ground ring to ground rod, halo drops to ground
ring, service entrance ground to ground rod.
5.1.4. Wire
All equipment grounds will be #6 AWG. Circuit grounding conductors
will be no more than two wire sizes smaller than the current
carrying conductors of the same circuit (minimum #12 AWG). All
external ground wire, including but not limited to the external
ground ring and external halo drops, will be #2 AWG solid tinned
copper.
5.2. Interior Grounding
5.2.1. Halo Ground
The halo ground will consist of a minimum #2 AWG wire located 3" to
12", below the finished ceiling, and will completely encircle the
equipment room. The wire will be green insulated stranded copper,
bare stranded copper, or bare tinned solid copper. Each corner of
the equipment room will have an omni-directional drop to the floor
of the same wire size and type as the halo ring. Connection of these
drops to the halo will be at least the defined minimum (see Section
5.1.3). If solid tinned wire is used, the drop will be one
continuous wire that is long enough to extend 8 feet beyond the
exterior of the shelter. If insulated wire is used, the drop will
extend to the floor, and then be connected in the same manner as the
halo, to an 8 foot length of solid tinned wire of the same size. The
exterior penetrations will be at 45 degree angles (to minimize
ground drop bend radii) and approximately one (1) inch in diameter.
5.2.2. Waveguide Entry Ground Bar
There will be a 1/4" x 4" x 20" (minimum) copper ground bar located
outside the shelter approximately 6" below the waveguide entry plate
(NEC Sec 800-33). This bar will be connected to the exterior ground
ring exothermic weld. The grounding conductor will be of the same
size and type as the halo ring.
5.2.3. AC Service
The AC service ground conductor will be bonded to the ground rod
located at the service entrance. Ground lugs provided in all service
entrance equipment will be bonded to the service ground conductor.
The system ground and neutral will be bonded at one location, as
close as practicable to the service entrance. All service grounding
shall conform to Article 250 of the National Electrical Code.
A-35
5.2.4. Primary Surge Arrester
There will be a surge protective device applied at the first piece
of service equipment inside the equipment shelter. This device will
be considered the primary surge protector. Conductors connecting the
surge protective device will be as short as possible, and will
contain no sharp bends or loops.
The operating characteristics of the primary surge arrester will
coordinate with the equipment surge withstand voltage capabilities.
The surge arrester should be capable of suppressing up to 65kVA, be
self restoring after operation, and may be equipped with a failure
alarm over current protective device and visual status indicators.
5.2.5. Cable Ladder
Cable ladder assemblies will be bonded to the halo ring with a #6
AWG or larger ground conductor. All cable ladder splices and
junctions will be bonded on at least one side with a #6 AWG or
larger conductor, and use grounding clips suitable for the purpose.
Paint will be removed as necessary for an electrically sound
connection.
5.2.6. Conduit Grounding
Each conduit discontinuity, including but not limited to conduit
couplings, junction boxes, light fixtures, and service equipment,
will be provided with ground clamps to electrically bond the
conduit. The bonding wire will be green insulated #6 AWG or larger.
5.2.7. Tower Light Controller Penetration
There will be a 1-1/2" penetration cast in place near the waveguide
entry port to allow for connection of the tower light controller.
The penetration will be lined with a 1" PVC running thread to
provide isolation between the interior and exterior conduit. The
running thread will be connected to interior and waterproof exterior
6" x 6" junction boxes.
5.3. Exterior Grounding
5.3.1. Ground Rods
There will be driven ground rods located at each corner of the
building, and at the AC service entrance and waveguide entry port.
These rods will be made of copper clad high strength steel with
minimum dimensions of 5/8" x 8'. The rods will be located at least
24" from the edge of the foundations, and driven such that the top
of the rod is below the frost line of the installation site. The
rods will be exothermically welded to the external halo drops.
A-36
5.3.2. Ground Ring
There will be a buried horizontal wire completely encircling the
equipment shelter. This wire will be solid tinned copper wire of #2
AWG or larger. The ground ring will not be closer than 24" from the
shelter foundations, and will be exothermically welded to each
ground rod. The ring will be buried 30" below grade or below the
frost line of the installation, whichever is greater.
The ground ring will be connected to the tower ground system from
the ground rod located at the waveguide port to the nearest ground
rod of the tower system. A second connection will be made from a rod
at a corner of the shelter to an alternate rod of the tower. These
connections will be made with a #2 AWG wire, or a wire of the same
size as the tower ground ring, whichever is larger.
5.3.3. Testing
The external ground system will be tested after installation, and
its resistance to earth ground will be less than 5 ohms. It is
recommended that tests be performed twice a year to insure ground
system integrity.
Xxxxxx Instruments Model DET2/2 Digital Ground Tester, or
equivalent, will be used for testing and all manufacturers'
instructions will be followed.
X-00
XXXXXXX X-0
NETWORK INTERCONNECTIONS SCHEDULE
SYSTEM SITE CODE OTHER SYSTEM SITE CODE HEIGHT AZIMUTH
---------------- ---------------------- ------ -------
X-00
XXXXXXX X-0
SYSTEM SPURS
PATHNET SPURS
The System shall contain the following spurs, which shall be
installed and operated for PathNet's network purposes:
Facility Name Latitude Longitude
-------- ---- -------- ---------
Hardscrabble, ND 48-03-36 000-00-00 Fox Creek, MT
(future WTCI)
Judson, ND 46-48-17 000-00-00 Bismark, ND
Glasgow, MT 48-11-03 000-00-00 (future B/N)
SPURS
The System shall contain the following Northern Border Pipeline spurs,
which shall be engineered, furnished, installed, and operated for Northern
Border Pipeline's internal communications requirements:
Facility Name Latitude Longitude Spur to:
------------- -------- --------- --------
Porcupine, MT 48-33-27 000-00-00 Xxxx Xxxx
Xxxx Xxxx, XX 48-21-53 000-00-00 Glasgow, MT
Xxxxxx, XX 00-00-00 000-00-00 Xxxxxx, XX
CS 00, XX 00-00-00 00-00-00 Xxxxxxxxx, XX
CS 13, MN 43-45-37 94-45-05 Welcome, MN
X-00
XXXXXXX X-0
FORM OF CERTIFICATE OF ACCEPTANCE
The undersigned, ___________________, who is ______________________ of
_________________, a ___________ [partnership/corporation] ("Incumbent") hereby
certifies as follows:
1. Incumbent has received from PathNet, Inc., a Delaware corporation
("PathNet") the results of all acceptance testing performed pursuant to Section
5 of Schedule A of the Fixed Point Microwave Services Agreement between PathNet
and Incumbent (the "FPM Agreement").
2. Incumbent has reviewed the results of such acceptance testing and
hereby acknowledges that the System (as defined in the FPM Agreement), as tested
and to be maintained by Incumbent, performs in accordance the Specifications, as
set forth in the FPM Agreement.
IN WITNESS WHEREOF, the undersigned has executed this Certificate of
Acceptance as of the ___ day of ______, 199__.
-----------------------------
A-40
SCHEDULE B
THE SYSTEM
1. System
The System extends from Port of Morgan, Montana to near the terminus of
Incumbent's system in Illinois with Facilities at the sites listed below.
2. Segment A
Incumbent Segment A extends from Port of Morgan, Montana to Ventura, Iowa,
with Facilities at the sites listed below.
FACILITY NAME LATITUDE LONGITUDE
------------- -------- ---------
Monchy, MT 48-59-59 000-00-00
Crow Creek, MT 48-58-23 000-00-00
CS1, MT 48-37-44 000-00-00
Porcupine, MT 48-33-27 000-00-00
Xxxx Xxxx, XX 00-00-00 000-00-00
Xxxxxxx, XX 48-11-03 000-00-00
CS2, MT 48-25-03 000-00-00
Hay Creek, MT 48-23-03 000-00-00
CS3, MT 48-12-47 000-00-00
Hardscrabble, ND 48-03-36 000-00-00
CS4, ND 47-46-14 000-00-00
Grassy Butte, ND 47-23-35 000-00-00
CS5, ND 47-15-14 000-00-00
Xxxxx Butte, ND 47-13-10 000-00-00
Elm Creek, ND 46-59-00 000-00-00
CS6, ND 46-49-16 000-00-00
Judson, ND 46-48-17 000-00-00
Mandan, ND 46-51-54 000-00-00
CS7, ND 46-30-55 000-00-00
Linton, ND 46-16-59 000-00-00
CS8, ND 46-03-58 99-37-11
Ashley, ND 45-59-28 00-00-00
Xxxx Xxxx, XX 00-00-00 99-11-53
CS9, SD 45-31-55 98-47-04
Aberdeen, SD 45-19-45 98-21-59
CS10, SD 45-03-58 97-31-58
Garden City, SD 44-56-23 97-31-58
B-1
Codington, SD 44-49-09 97-11-50
CS11, SD 44-39-53 96-48-30
Brookings, XX 00-00-00 00-00-00
Xxxx Xxxxxxxxx, XX 44-24-48 96-28-03
Lake Stay, MN 44-21-54 96-08-27
CS12, MN 44-14-05 95-46-26
Xxxxxxx, MN 44-01-54 95-14-21
CS13, MN 43-45-37 94-27-03
Welcome, MN 43-40-24 94-35-28
East Chain, MN 43-30-42 94-27-03
Crystal Lake, IA 43-15-12 93-46-18
Ventura, IA 43-06-47 93-31-22
3. Segment B
Incumbent Segment B extends from Ventura, Iowa to near the terminus of
Incumbent's system in Illinois, with Facilities at the sites listed below.
FACILITY NAME LATITUDE LONGITUDE
------------- -------- ---------
B-2
SCHEDULE C
ESTIMATED AND OPERATING COSTS
SECTION 1. INCUMBENT ITEMS AND ESTIMATED COSTS
A. Segment A
The Incumbent Estimated Costs and Items are set forth in Exhibit C-1.
B. Segment B
The Incumbent Estimated Costs shall be developed and approved by the
parties and shall be set forth in detail in an Amended Exhibit C-1.
SECTION 2. INCUMBENT OPERATING AND ADMINISRATION COSTS
1. [***]
2. [***]
3. [***]
4. [***]
5. [***]
6. [***]
7. [***]
8. [***]
9. [***]
10. [***]
C-1
11. [***]
12. [***]
13. [***]
14. [***]
15. [***]
16. [***]
17. [***]
18. [***]
19. [***]
20. [***]
21. [***]
22. [***]
23. [***]
24. [***]
C-2
[***]
25. [***]
26. [***]
27. [***]
28 [***]
30. [***]
SECTION 3. PATHNET ADMINISTRATION AND OPERATING COSTS
1. [***]
2. [***]
3. [***]
4. [***]
5. [***]
C-3
6. [***]
7. [***]
8. [***]
9. [***]
10. [***]
11. [***]
12. [***]
13. [***]
14. [***]
15. [***]
16. [***]
17. [***]
18. [***]
19. [***]
20. [***]
21. [***]
22. [***]
C-4
[***]
23. [***]
24. [***]
25. [***]
26. [***]
27. [***]
28. [***]
29. [***]
30. [***]
31. [***]
32. [***]
33. [***]
34. [***]
35. [***]
C-5
36. [***]
37. [***]
38. [***]
39. [***]
40. [***]
C-6
EXHIBIT C-1
INCUMBENT ESTIMATED COSTS AND ITEMS
CROW EAST
MONCHY CREEK CS 1 PORCUPINE FORK
------ ----- ---- --------- ----
3 Way Jct Spur-rptr
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate
Mods: [***] [***]
Road Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg. Mods: [***]
New Building: [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***]
AC Power : [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***] [***]
Batterys: [***] [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
X-0
XXXX XXXX
XXXXXX XXXXX XX 0 XXXXXXXXX XXXX
------ ----- ---- --------- ----
3 Way Jct Spur-rptr
Antenna
Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P Software/LT
Maint Kit:
Radio Spares:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1: [***]
OC-3 to 28 DS-1: [***]
ADM 8 DS-1
OC-3 Spares:
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES : [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
C-8
HAY HARD
GLASGOW CS 2 CREEK CS 3 SCRABBLE
------- ---- ----- ---- --------
Spur-term
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate
Mods: [***] [***]
Road Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg. Mods: [***]
New Building: [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***]
AC Power : [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***]
Batterys: [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
C-9
HAY HARD
GLASGOW CS 2 CREEK CS 3 SCRABBLE
------- ---- ----- ---- --------
Spur-term
Antenna
Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2 Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT [***]
Maint Kit: [***]
Radio Spares: [***]
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1:
OC-3 to 28 DS-1: [***]
ADM 8 DS-1 [***]
OC-3 Spares: [***]
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES : [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
C-10
GRASSY XXXXXX ELM
CS 4 BUTTE CS 5 BUTTE CREEK
---- ----- ---- ----- -----
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate
Mods: [***] [***] [***]
Road
Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg. Mods:
New Building: [***] [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***] [***]
AC Power : [***] [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***] [***]
Batterys: [***] [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
C-11
GRASSY XXXXXX ELM
CS 4 BUTTE CS 5 BUTTE CREEK
---- ----- ---- ----- -----
Antenna Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2 Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT
Maint Kit:
Radio Spares:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1:
OC-3 to 28 DS-1:
ADM 8 DS-1 [***] [***]
OC-3 Spares:
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES : [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
X-00
XX 0 XXXXXX XXXXXX CS 7 XXXXXX
---- ------ ------ ---- ------
3 Way Jct Spur-term
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate Mods: [***] [***]
Road
Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg. Mods: [***]
New Building: [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***]
AC Power : [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***]
Batterys: [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
X-00
XX 0 XXXXXX XXXXXX CS 7 XXXXXX
---- ------ ------ ---- ------
3 Way Jct Spur-term
Antenna
Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT
Maint Kit: [***]
Radio Spares: [***]
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1: [***] [***]
OC-3 to 28 DS-1:
ADM 8 DS-1
OC-3 Spares: [***]
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES: [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
X-00
XX 0 XXXXXX XXXX XX 0 XXXXXXXX
---- ------ ---- ---- --------
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate Mods: [***] [***]
Road
Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg. Mods:
New Building: [***] [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***] [***]
Building
Ground: [***] [***] [***] [***] [***]
AC Power : [***] [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***] [***]
Batterys: [***] [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
X-00
XX 0 XXXXXX XXXX XX 0 XXXXXXXX
---- ------ ---- ---- --------
Antenna
Material: [***] [***] [***] [***] [***]
Install &
Align Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal:
& 2Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT
Maint Kit:
Radio Spares:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56
DS-1:
OC-3 to 28
DS-1:
ADM 8 DS-1 [***] [***]
OC-3 Spares:
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***]
Test & Turnup: [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES: [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
X-00
XXXXXX
XX 00 XXXX XXXXXXXXX XX 11 BROOKINGS
----- ---- --------- ----- ---------
3 Way Jct Spur-term
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate Mods: [***] [***]
Road Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg.
Mods: [***]
New Building: [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***]
Building
Ground: [***] [***] [***] [***]
AC Power: [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***]
Batterys: [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
X-00
XXXXXX
XX 00 XXXX XXXXXXXXX XX 11 BROOKINGS
----- ---- --------- ----- ---------
3 Way Jct Spur-term
Antenna
Material: [***] [***] [***] [***] [***]
Install &
Align Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal:
& 2Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT
Maint Kit: [***]
Radio Spares:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56
DS-1:
OC-3 to 28
DS-1: [***] [***]
ADM 8 DS-1 [***]
OC-3 Spares:
Install: [***] [***] [***]
Test & Turnup: [***] [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES: [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
C-18
LAKE LAKE
SHAOKATAN STAY CS 12 XXXXXXX XX 13
--------- ---- ----- ------- -----
3 Way Jct
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level:
Fence & Gate Mods: [***] [***]
Road Const/Repair:
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***] [***]
Tower Ground:
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg.
Mods:
New Building: [***] [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***] [***]
AC Power : [***] [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW
25KW [***] [***] [***]
35KW
Transfer Panel:
Install & Test
Labor: [***] [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***] [***]
Batterys: [***] [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
C-19
LAKE LAKE
SHAOKATAN STAY CS 12 XXXXXXX XX 13
--------- ---- ----- - ------- -----
3 Way Jct
Antenna
Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2Way [***] [***] [***] [***] [***]
1:1 Repeater:
OAM&P
Software/LT
Maint Kit:
Radio Spares:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1:
OC-3 to 28 DS-1: [***]
ADM 8 DS-1 [***]
OC-3 Spares:
Install: [***] [***]
Test & Turnup: [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***] [***]
DS-1 MUX
I/O DAX:
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES: [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
C-20
EAST CRYSTAL
WELCOME CHAIN LAKE VENTURA TOTALS
------- ----- ---- ------- ------
Spur-term
PCN Coordination: [***] [***] [***] [***] [***]
Site Survey: [***] [***] [***] [***] [***]
PLEM ENG: [***] [***] [***] [***] [***]
Site Clearing/Level: [***]
Fence & Gate Mods: [***] [***] [***]
Road Const/Repair: [***]
SITE WORK: [***] [***] [***] [***] [***]
Tower Analysis: [***] [***] [***] [***] [***]
Tower Strength
Material: [***] [***] [***] [***] [***]
Tower Labor: [***] [***] [***] [***] [***]
Waveguide
Bridge: [***] [***] [***] [***]
Tower Ground: [***]
TOWERS: [***] [***] [***] [***] [***]
Exist Bldg.
Mods: [***] [***]
New Building: [***] [***] [***] [***]
New Bldg
Delivery: [***] [***] [***] [***]
New Bldg
Fondation: [***] [***] [***] [***]
Building Ground: [***] [***] [***] [***]
AC Power: [***] [***] [***] [***]
BUILDINGS: [***] [***] [***] [***] [***]
15KW [***]
25KW [***] [***] [***] [***]
35KW [***]
Transfer Panel: [***]
Install & Test
Labor: [***] [***] [***] [***]
GENERATORS: [***] [***] [***] [***] [***]
Chargers: [***] [***] [***] [***]
Batterys: [***] [***] [***] [***]
Power
Board/Panel: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***]
D.C. PLANT: [***] [***] [***] [***] [***]
C-21
EAST CRYSTAL
WELCOME CHAIN LAKE VENTURA TOTALS
------- ----- ---- ------- ------
Spur-term
Antenna
Material: [***] [***] [***] [***] [***]
Install & Align
Labor: [***] [***] [***] [***] [***]
ANTENNAS: [***] [***] [***] [***] [***]
Waveguide
Material: [***] [***] [***] [***] [***]
Install & Test
Labor: [***] [***] [***] [***] [***]
WAVEGUIDE: [***] [***] [***] [***] [***]
1:1 Terminal: &
2Way [***] [***] [***] [***] [***]
1:1 Repeater: [***]
OAM&P
Software/LT [***] [***]
Maint Kit: [***] [***]
Radio Spares: [***] [***]
Install: [***] [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***] [***]
RADIOS: [***] [***] [***] [***] [***]
OC-3 to 56 DS-1: [***] [***]
OC-3 to 28 DS-1: [***] [***]
ADM 8 DS-1 [***]
OC-3 Spares: [***] [***]
Install: [***] [***] [***]
Test & Turnup: [***] [***] [***]
OC3 MULTIPLEX: [***] [***] [***] [***] [***]
Channel Bank: [***] [***] [***] [***] [***]
DS-1 MUX [***]
I/O DAX: [***]
Install: [***] [***] [***] [***]
Test & Turnup: [***] [***] [***] [***]
C/B MUX/ DAX: [***] [***] [***] [***] [***]
FREIGHT: [***] [***] [***] [***] [***]
SALES TAXES: [***] [***] [***] [***] [***]
Path
Engineering: [***] [***] [***] [***] [***]
System
Engineering: [***] [***] [***] [***] [***]
Project
Engineering: [***] [***] [***] [***] [***]
PATHNET ENG: [***] [***] [***] [***] [***]
PROJECT TOTAL: [***] [***] [***] [***] [***]
C-22
INCUMBENT ESTIMATED COSTS AND ITEMS SUMMARY
PLEM ENG [***]
SITE WORK [***]
TOWERS [***]
BUILDINGS [***]
GENERATORS [***]
D.C. PLANT [***]
ANTENNAS [***]
WAVEGUIDE [***]
RADIOS [***]
OC3 MULTIPLEX [***]
C/B MUX/ DAX [***]
FREIGHT [***]
SALES TAXES [***]
PATHNET ENG [***]
TOTAL [***]
Note: PathNet Engineering Summary Totals as set forth in the Project Totals of
this Exhibit are not items to be paid by Incumbent.
C-23
EXHIBIT C-2
SYSTEM PAYMENT*
------------------------------------------------------
Time Period Payment
------------------------------------------------------
Year 1
------------------------------------------------------
Quarter 1 [***]
------------------------------------------------------
Quarter 2 [***]
------------------------------------------------------
Quarter 3 [***]
------------------------------------------------------
Quarter 4 [***]
------------------------------------------------------
Year 2
------------------------------------------------------
Quarter 1 [***]
------------------------------------------------------
Quarter 2 [***]
------------------------------------------------------
Quarter 3 [***]
------------------------------------------------------
Quarter 4 [***]
------------------------------------------------------
Year 3
------------------------------------------------------
Quarter 1 [***]
------------------------------------------------------
Quarter 2 [***]
------------------------------------------------------
Quarter 3 [***]
------------------------------------------------------
Quarter 4 [***]
------------------------------------------------------
Year 4
------------------------------------------------------
Quarter 1 [***]
------------------------------------------------------
Quarter 2 [***]
------------------------------------------------------
Quarter 3 [***]
------------------------------------------------------
Quarter 4 [***]
------------------------------------------------------
Total Payment [***]
------------------------------------------------------
*Assumes total R/F costs of $2.5 million (excludes costs of multiplexing to DS-0
level and incremental costs of all back-to-back terminals) and an interest rate
of 10%. AMOUNTS TO BE ADJUSTED FOR FINAL BUDGETED RF COSTS.
C-24
SCHEDULE D
OWNERSHIP STATUS OF INCUMBENT SITES
================================================================
Ownership
Site County Status
----------------------------------------------------------------
Crow Creek Xxxxxxxx 3
----------------------------------------------------------------
CS-1 Valley 2
----------------------------------------------------------------
Porcupine Valley 1
----------------------------------------------------------------
CS-2 Roosevelt 1
----------------------------------------------------------------
Hay Creek Roosevelt 1
----------------------------------------------------------------
CS-3 Roosevelt 1
----------------------------------------------------------------
Hardscrabble Xxxxxxxx 1
----------------------------------------------------------------
CS-4 XxXxxxxx 1
----------------------------------------------------------------
Grassy Butte XxXxxxxx 1
----------------------------------------------------------------
CS-5 Xxxx 1
----------------------------------------------------------------
Xxxxx Butte Xxxxxx 1
----------------------------------------------------------------
Elm Creek Xxxxxx 1
----------------------------------------------------------------
CS-6 Xxxxxx 1
----------------------------------------------------------------
Xxxxxx Xxxxxx 3
----------------------------------------------------------------
CS-7 Xxxxxx 1
----------------------------------------------------------------
Xxxxxx Xxxxxx 1
----------------------------------------------------------------
CS-8 XxXxxxxx 1
----------------------------------------------------------------
CS-9 Edmunds 1
----------------------------------------------------------------
Aberdeen Measurement
Station Xxxxx 1
----------------------------------------------------------------
CS-10 Xxxxx 1
----------------------------------------------------------------
Garden City Xxxxx 1
----------------------------------------------------------------
Codington Codington 1
----------------------------------------------------------------
Brookings Brookings 1
----------------------------------------------------------------
CS-11 Xxxxx 1
----------------------------------------------------------------
Lake Shaokatan Brookings 1
----------------------------------------------------------------
Lake Stay Lincoln 1
----------------------------------------------------------------
CS-12 Lyon 1
----------------------------------------------------------------
Xxxxxxx Cottonwood 1
----------------------------------------------------------------
CS-13 Xxxxxx 1
----------------------------------------------------------------
East Chain Xxxxxx 1
----------------------------------------------------------------
Crystal Lake Xxxxxxx 1
----------------------------------------------------------------
Monchy Xxxxxxxx 2
----------------------------------------------------------------
East Fork Valley 1
----------------------------------------------------------------
Glasgow Valley 1
----------------------------------------------------------------
Mandan Xxxxxx 1
----------------------------------------------------------------
Xxxxxx XxXxxxxx 1
----------------------------------------------------------------
Welcome Measurement
Station Xxxxxx 1
----------------------------------------------------------------
Long Lake XxXxxxxxx 1
================================================================
1- Sites owned in Fee by Incumbent
2- Sites occupied by Incumbent pursuant to Right-of-Way Grant from the Bureau
of Land Management (No. M-29897)
3- Sites leased by Incumbent
D-1
SCHEDULE E
INCUMBENT SECURITY PROCEDURES
See attached Northern Border Pipeline Company Operating Procedures for Visitor
and Facility Security consisting of 1 page.
E-1
--------------------------------------------------------------------------------
OPERATING PROCEDURES
--------------------------------------------------------------------------------
[NORTHERN BORDER Visitors and Facility Security Procedure No.: 120.202
PIPELINE COMPANY Section: Security
LOGO] Revision: 3
Effective date: 12-15-95
--------------------------------------------------------------------------------
PURPOSE:
This procedure establishes requirements for access by visitors to Company
properties in order to safeguard the visitors and the security and welfare of
Company employees and properties and helps achieve compliance with DOT
Regulations 192.163(d).
RESPONSIBILITY FOR ADMINISTRATION:
Location Team.
RELATED PROCEDURES:
80.302 Signs - Specifications and Applications
PROCEDURE:
I. Do not allow visitors unknown to the Location Team or his immediate
subordinates to enter further than the office at any location unless they
provide proper identification and a justifiable purpose for the visit.
II. Allow visits only during normal daytime working hours, unless special
arrangements for visits have been made.
III. Require all visitors to sign a guest register and record the purpose of
the visit.
IV. Provide all visitors with appropriate safety protection and a Company
employee escort at all times.
V. Post a sign at each entrance from a public road reading:
A. "Visitors - Apply at Office" at locations with offices with employee
present during normal working hours.
B. "Authorized Personnel Only" at all other locations.
C. Reference Procedure 80.302 for information on signs.
VI. Lock property entrance gates:
A. When locations are unattended.
B. During times outside of normal working hours at continuously
attended locations.
C. If closed, the main entrance gates and all gates within 200 feet of
a compressor building must be openable without a key.
RECORDS:
Retain guest register information for twelve months.
RESPONSIBILITY FOR PROCEDURE:
Address all questions on this procedure to the V.P., Operations and
Administration.
--------------------------------------------------------------------------------
Bold Print Denotes Revision Page 1 of 1
SCHEDULE F
[RESERVED]
F-1
SCHEDULE G
INCUMBENT POLICY ON DRUGS AND ALCOHOL IN THE WORKPLACE
[Policy on Drugs and Alcohol provided by Incumbent to Pathnet
under separate cover]
G-1
SCHEDULE H
INCUMBENT SAFETY PROCEDURES
[Safety procedures provided by Incumbent to Pathnet under separate cover]
H-1
SCHEDULE I
[RESERVED]
I-1
SCHEDULE J
INCUMBENT TRAINING
1. Pre-Commissioning Training. Prior to Commissioning of the System, PathNet
shall provide to Incumbent one training course for Incumbent's employees and
other designees of Incumbent, which training shall include, among other things,
the following:
(a) comprehensive instruction for trouble-free operation maintenance;
(b) hands-on experience with the operation of the equipment deployed in
the System;
(c) review of the similarities and differences of an analog versus a
digital system;
(d) review of the latest state-of-the-art Technology and applications
used in the System;
(e) review of procedures designed to eliminate equipment damage,
incorrect handling of equipment and System downtime;
(f) comprehensive instruction in the use of all required test equipment
used in connection with the System;
(g) the distribution of manuals and other course materials that include
descriptive information publications, alignment procedures,
maintenance procedures, technical information publications,
schematic drawings, wiring lists and system assembly drawings; and
(h) a certificate of completion for each student who successfully
completes the training course.
2. Certification of Incumbent's Field Technicians. Each of Incumbent's Field
Technicians (as defined in the Maintenance Services Agreement) must either
successfully complete the training course described in Section 1 of this
Schedule J, or must be certified by PathNet that such Field Technician is
qualified to perform services on the System.
3. Training for Upgrades. Upon any upgrade of the system, Incumbent may request
that PathNet provide additional training with respect to such upgrade and
PathNet shall provide such training to Incumbent as soon as practicable after
such request.
4. Training Locations. All such training shall be provided at PathNet's
Richardson, Texas office, Washington D.C. metropolitan area headquarters or at
such other location as determined by PathNet in its sole discretion.
J-1
5. Travel and Lodging.[***]
J-2
SCHEDULE K
OWNERSHIP
A. OWNERSHIP OF SEGMENTS A AND B INITIAL SYSTEM EQUIPMENT ASSETS AND
MATERIALS
Segment A
-------------------------------------------------------------------------------
System Component Owned By
-------------------------------------------------------------------------------
Existing Shelters [***]
-------------------------------------------------------------------------------
New Shelters for System [***]
-------------------------------------------------------------------------------
New Shelters at PathNet Spur sites [***]
-------------------------------------------------------------------------------
New Shelters at Incumbent Spur sites [***]
-------------------------------------------------------------------------------
Towers for System [***]
-------------------------------------------------------------------------------
Towers for Incumbent Spurs [***]
-------------------------------------------------------------------------------
Towers for PathNet Spurs [***]
-------------------------------------------------------------------------------
A.C. and D.C. Power system as set forth on Schedule J [***]
-------------------------------------------------------------------------------
Pressurizing Equipment for sites including manifolds and [***]
dehydrators
-------------------------------------------------------------------------------
1/0 Multiplexers [***]
-------------------------------------------------------------------------------
Environmental Control Systems of Shelters of System [***]
-------------------------------------------------------------------------------
Environmental Control Systems of Shelters of Incumbent Spurs [***]
-------------------------------------------------------------------------------
Environmental Control Systems of Shelters of PathNet Spurs [***]
-------------------------------------------------------------------------------
Common Equipment existing Before Effective Date [***]
-------------------------------------------------------------------------------
Common Equipment newly installed [***]
-------------------------------------------------------------------------------
Equipment Racks for System Radios [***]
-------------------------------------------------------------------------------
Antennas and Antenna Mounts relating to System [***]
-------------------------------------------------------------------------------
Antennas and Antenna Mounts relating to Incumbent Spurs [***]
-------------------------------------------------------------------------------
Antennas and Antenna Mounts relating to PathNet Spurs [***]
-------------------------------------------------------------------------------
Waveguide and Waveguide bridges relating to System [***]
-------------------------------------------------------------------------------
Waveguide and Waveguide bridges relating to Incumbent Spurs [***]
-------------------------------------------------------------------------------
Waveguide and Waveguide bridges relating to PathNet Spurs [***]
-------------------------------------------------------------------------------
Radios relating to System [***]
-------------------------------------------------------------------------------
Radios relating to Incumbent Spurs [***]
-------------------------------------------------------------------------------
Radios relating to PathNet Spurs [***]
-------------------------------------------------------------------------------
OC-3 Multiplexers [***]
-------------------------------------------------------------------------------
Radio Bays and Radio Bay Equipment relating to the System [***]
-------------------------------------------------------------------------------
Radio Bays and Radio Bay Equipment relating to Incumbent Spurs [***]
-------------------------------------------------------------------------------
Radio Bays and Radio Bay Equipment relating to the PathNet Spurs [***]
-------------------------------------------------------------------------------
Interconnection Equipment relating to PathNet Spurs and [***]
Interconnections
-------------------------------------------------------------------------------
Interconnection Equipment relating to Incumbent Spurs and [***]
Interconnections
-------------------------------------------------------------------------------
Results of the Preliminary Engineering Studies and Project [***]
Drawings set forth in
-------------------------------------------------------------------------------
K-1
-------------------------------------------------------------------------------
System Component Owned By
-------------------------------------------------------------------------------
Section 6.2
-------------------------------------------------------------------------------
Microwave Radio System Licenses and other FCC, Federal, state and [***]
local licenses and Permits relating to the System
-------------------------------------------------------------------------------
Panels, terminals, Software, Source Codes and other Assets and [***]
Equipment relating to the Network Management System
-------------------------------------------------------------------------------
B. OWNERSHIP OF ANY SEGMENT A OR B CAPACITY EXPANSION SYSTEM EQUIPMENT,
ASSETS AND MATERIALS
All equipment required for Capacity Expansions on Segments A and B will be
owned by [***].
K-2
SCHEDULE L
FORM OF QUARTERLY REVENUE REPORT
PATHNET INCUMBENT
PATH OR NUMBER OF PRICE PER REVENUE REVENUE REVENUE TO REVENUE TO
SEGMENT START DATE END DATE DS-0'S SOLD CIRCUIT MILE COLLECTED OUTSTANDING BE PAID BE PAID
------- ---------- -------- ----------- ------------ --------- ----------- ------- -------
L-1
SCHEDULE M
INCUMBENT'S PAYMENT INSTRUCTIONS
Payments to Incumbent shall be by wire transfer in accordance with the following
wire transfer instructions:
M-1
SCHEDULE N
PATHNET PROGRAM SUBLICENSE AGREEMENT
This Sublicense Agreement (the "Agreement") is made on _____________, 1997
(the "Effective Date") by and between PathNet, Inc. ("PathNet") and Northern
Border Pipeline Company ("Incumbent") for the use of VERTEL Corporation
("Licensor") programs.
WHEREAS, Incumbent desires to sublicense the programs as further defined
herein; and
WHEREAS, PathNet is willing to grant such sublicense under the terms and
conditions set forth herein;
NOW, THEREFORE, in consideration of the mutual promises contained herein,
the Parties mutually agree as follows:
I. DEFINITIONS.
1.1 "Licensed Program" shall mean each program in software or firmware
form provided by PathNet to Incumbent pursuant to the Fixed Point Microwave
Services Agreement, dated the date hereof between Incumbent and PathNet (the
"FPM Agreement"), as such Licensed Program is licensed by PathNet from Licensor,
including future additions and updates to such Licensed Program. The term
"Licensed Program" shall specifically include documentation and related
materials pertinent to such program and any updated program or portion of a
program hereinafter furnished to Incumbent for use in connection with or
replacement of the Licensed Programs.
1.2 "Equipment" shall mean Intel compatible servers running Windows NT.
1.3 "Use" shall mean the copying or duplication of any portion of a
Licensed Program from storage units or media into the Equipment for processing
or the utilization of any Licensed Program in the course of the operation of the
Equipment.
II. LICENSE GRANT.
2.1 Use of Object/Binary Licensed Program with Designated Equipment.
PathNet hereby grants Incumbent a non-exclusive, non-transferable (except as
provided in Section 5.1), non-licensable, non-assignable license to Use in
machine readable form, the Licensed Program specified in Section 1.1 solely on
the Equipment specified in Section 1.2. No license is granted to use any
Licensed Program on any configuration of equipment which is different from or
less than the configuration indicated in Section 1.2.
N-1
III. PROPRIETARY RIGHTS.
3.1 Proprietary Rights. The Licensed Program is owned by Licensor and/or
others and is proprietary in nature. Incumbent shall respect such proprietary
rights and shall not use such Licensed Program except for the purposes for which
it is being made available as set forth in this Agreement and shall not
reproduce, print, sublicense, duplicate, reverse engineer, distribute, disclose,
or otherwise make the Licensed Program available to any third party, in whole or
in part, in whatever form.
3.2 Confidentiality. Incumbent shall take all actions required to maintain
control of the Licensed Program including securing written records, agreements,
and other reasonable measures with its employees and agents to satisfy its
obligations under this Agreement with respect to the use, copying, protection,
and security of the Licensed Program.
IV. LIMIT OF LIABILITY.
4.1 NO WARRANTY. LICENSOR GRANTS A WARRANTY IN THE LICENSED PROGRAM ONLY
TO PATHNET AND DOES NOT EXTEND ITS WARRANTY TO INCUMBENT OR ANY OTHER END USER.
WARRANTY OF THE LICENSED PROGRAM IS PROVIDED BY LICENSOR DIRECTLY TO PATHNET.
LICENSOR AND PATHNET MAKE NO EXPRESS OR IMPLIED WARRANTIES OF ANY KIND,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE WITH REGARD TO ANY LICENSED PROGRAM AND/OR RELATED MATERIALS TO BE
FURNISHED BY VERTEL.
4.2 NO CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL LICENSOR OR PATHNET BE
LIABLE FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR
ARISING OUT OF THE EXISTENCE, FURNISHING, FAILURE TO FURNISH, OR USE OF ANY
LICENSED PROGRAM AND/OR RELATED MATERIAL AND/OR DEVISE.
4.3 Licensor shall have no liability for any claim of copyright or patent
infringement based on (1) use of other than a current unaltered release of the
Licensed Program available from Licensor if such infringement would have been
avoided by the use of such current unaltered release of the Licensed Program or
(2) Use or combination of the Licensed Program with programs not supplied by
Licensor and which Use or combination results in the infringement of any patent
or copyright.
V. TRANSFER OF LICENSE.
5.1 Terms for Transfer of License. This license may only be transferred
upon written approval of PathNet and in connection with the transfer of all of
the Equipment; provided
N-2
all copies of the Licensed Program are delivered to the transferee and no copies
or related materials are retained by Incumbent and provided further that the
transferee agrees to be bound by all the Terms and Conditions of this Agreement.
NOW THEREFORE, the Parties hereto have caused this Agreement to be
executed by their respective duly authorized representatives.
PATHNET, INC.
By:
-----------------------------------------
Name:
---------------------------------------
Title:
--------------------------------------
NORTHERN BORDER PIPELINE COMPANY
By: Northern Plains Natural Gas Company,
Operator
By:
-----------------------------------------
Name:
---------------------------------------
Title:
--------------------------------------
N-3
INDEX OF SCHEDULES AND EXHIBITS TO
FIXED POINT MICROWAVE SERVICES AGREEMENT
SCHEDULE A: Services and System Specifications
Exhibit A-1: Equipment
Exhibit A-2: Manufacturers Specifications for Radios
Exhibit A-3: Electricity and Power Specifications of the System
Exhibit A-4: Initial Incumbent Channel Plan
Exhibit A-5: Equipment Shelters Specifications and Design
Exhibit A-6: Grounding and Lightning Protection Guidelines and
Specifications for Communications Shelters
Exhibit A-7: Network Interconnections Schedule
Exhibit A-8: System Spurs
Exhibit A-9: Form of Certificate of Acceptance
SCHEDULE B: The System
SCHEDULE C: Estimated and Operating Costs
Exhibit C-1: Incumbent Estimated Costs and Items
Exhibit C-2: System Payment
SCHEDULE D: Ownership Status of Incumbent Sites
SCHEDULE E: Incumbent Security Procedures
SCHEDULE F: Reserved
SCHEDULE G: Incumbent Policy on Drugs and Alcohol in the Workplace
SCHEDULE H: Incumbent Safety Procedures
SCHEDULE I: Reserved
SCHEDULE J: Incumbent Training
SCHEDULE K: Ownership
SCHEDULE L: Form of Quarterly Revenue Report
SCHEDULE M: Incumbent's Payment Instructions
SCHEDULE N: PathNet Program Sublicense Agreement
2