Explore a free library of open-source, peer-reviewed contract standards, adopted by thousands of business around the world and signed millions of times.
1 EXHIBIT 10.12 ALL SECTIONS MARKED WITH TWO ASTERISKS ("**") REFLECT PORTIONS WHICH HAVE BEEN REDACTED AND FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION BY FLOUR CITY INTERNATIONAL, INC. AS PART OF A REQUEST FOR CONFIDENTIAL TREATMENT. This Agreement, made as of the Fourth day of December in the year one thousand nine hundred and ninety-six by and between XXXXXX CONSTRUCTION COMPANY, a New York Corporation, (hereinafter called XXXXXX) and FLOUR CITY ARCHITECTURAL METALS, INC., a Delaware Corporation with offices located at 000 Xxxxxxxxx Xxxxx, Xxxxxxx Xxxx, XX 00000 (hereinafter called the Subcontractor). Contract No. 6000H A. L. 24 TCCo. 21 Description of Work Witnesseth, that the Subcontractor and Xxxxxx agree as follows: ARTICLE I. The Subcontractor shall perform and furnish all the work, labor, services, materials, plant, equipment, tools scaffolds, appliances and all other things necessary for B. P. 3A Glazed Aluminum Curtain Wall System (hereinafter called the Work) for and at the Cleveland Clinic Foundation, Health Sciences Center (hereinafter called the Project), located on premises at 0000 Xxxxxxxx Xxxxxx, Xxxxxxxxx, Xxxx (hereinafter called the Premises), as shown and described in and in strict accordance with the Plans, Specifications, General Conditions, Special Conditions and Addenda thereto prepared by Xxxxx Xxxxx, New Haven, CT (hereinafter called the Architect) and with the terms and provisions of the General Contract (hereinafter called the General Contract) between Xxxxxx and The Cleveland Clinic Foundation (hereinafter called the Owner) dated October 23, 1996 (Letter of Intent) and in strict accordance with the additional Provisions, page(s) 3A thru 3E annexed hereto and made a part hereof. Contract Documents ARTICLE II. The Plans, Specifications, General Conditions, Special Conditions, Addenda and General Contract hereinabove mentioned, are available for examination by the Subcontractor at all reasonable times at the office of Xxxxxx, all of the aforesaid, including this Agreement, being hereinafter sometimes referred to as the Contract Documents. The Subcontractor represents and agrees that it has carefully examined and understands this Agreement and the other Contract Documents, has investigated the nature, locality and site of the Work and the conditions and difficulties under which it is to be performed and that it enters into this Agreement on the basis of its own examination, investigation and evaluation of all such matters and not in reliance upon any opinions or representations of Xxxxxx, or of the Owner, or of any of their respective officers, agents, servants, or employees. With respect to the Work to be performed and furnished by the Subcontractor hereunder, the Subcontractor agrees to be bound to Xxxxxx by each and all of the terms and provisions of the General Contract and the other Contract Documents, and to assume toward Xxxxxx all of the duties, obligations and responsibilities that Xxxxxx by those Contract Documents assumes toward the Owner, and the Subcontractor agrees further that Xxxxxx shall have the same rights and remedies as against the Subcontractor as the Owner under the terms and provisions of the General Contract and the other Contract Documents has against Xxxxxx with the same force and effect as though every such duty, obligation, responsibility, right or remedy were set forth herein in full. The terms and provisions of this Agreement with respect to the Work to be performed and furnished by the Subcontractor hereunder are intended to be and shall be in addition to and not in substitution for any of the terms and provisions of the General Contract and the other Contract Documents. This Subcontract Agreement, the provisions of the General Contract and the other Contract Documents are intended to supplement and complement each other and shall, where possible, be thus interpreted. If, however, any provision of this Subcontract Agreement irreconcilably conflicts with a provision of the General Contract and the other Contract Documents, the provision imposing the greater duty or obligation on the Subcontractor shall govern. Although drawn by Xxxxxx, this Subcontract Agreement shall, in the event of any dispute over its meaning or application, be interpreted fairly and reasonably and neither more strongly for nor against either party to it. Time of Completion ARTICLE III. The Subcontractor shall commence the Work when notified to do so by Xxxxxx and shall diligently and continuously prosecute and complete the Work and coordinate the Work with the other work being performed on the Project, in accordance with the project schedule, any revisions to the project schedule, and any other scheduling requirements listed in this Agreement, so as not to delay, impede, obstruct, hinder or interfere with the commencement, progress or completion of the whole or any part of the Work or other work on the Project. The Subcontractor shall participate and cooperate in the development of the project schedule providing information for the scheduling of the times and sequence of operations required for its Work to meet Xxxxxx'x overall schedule requirements, shall continuously monitor the project schedule so as to be fully familiar with the timing, phasing and sequence of operations of the Work and of other work on the Project, and shall execute the Work in accordance with the requirements of the project schedule including any revisions thereto. Should the progress of the Work or of the Project be delayed by any fault or neglect or act or failure to act of the Subcontractor or any of its officers, agents, servants, employees, subcontractors or suppliers so as to cause any additional cost, expense, liability or damage to Xxxxxx or to the Owner or any damages or additional costs or expenses for which Xxxxxx or the Owner may or shall become liable, the Subcontractor shall and does hereby agree to compensate Xxxxxx and the Owner for and indemnify them against all such costs, expenses, damages and liability. 1 2 ** Confidential treatment requested pursuant to Rule 406 Xxxxxx, if it deems necessary, may direct the Subcontractor to work overtime and if so directed the Subcontractor shall work said overtime and, provided that the Subcontractor is not in default under any of the terms or provisions of this Agreement or of any of the other Contract Documents. Xxxxxx will pay the Subcontractor for such actual additional wages paid, if any, at rates which have been approved by Xxxxxx, plus taxes imposed by law on such additional wages, plus workers' compensation insurance, liability insurance and levies on such additional wages if required to be paid by the Subcontractor. If, however, the progress of the Work or of the Project be delayed by delayed by any fault or neglect or act or failure to act of the Subcontractor or any of its officers, agents, servants, employees, subcontractors or suppliers, then the Subcontractor shall, in addition to all of the other obligations imposed by this Agreement upon the Subcontractor in such case, and at its own cost and expense, work such overtime as may be necessary to make up for all time lost in the completion of the Work and of the Project due to such delay. Should the Subcontractor fail to make up for the time lost by reason of such delay, Xxxxxx shall have the right to cause other subcontractors to work overtime and to take whatever other action it deems necessary to avoid delay in the completion of the Work and of the Project, and the cost and expense of such overtime and/or such other action shall be borne by the Subcontractor. Price ARTICLE IV. The sum to be paid by Xxxxxx, out of funds received from the owner, to the Subcontractor for the satisfactory performance and completion of the Work and, of all of the duties, obligations and responsibilities of the Subcontractor under this Agreement and the other Contract Documents shall be **. (hereinafter called the Price) subject to additions and deductions as herein provided The price includes all Federal, State, County, Municipal and other taxes imposed by law and based upon labor, services, materials, equipment or other items acquired, performed, furnished or used for or in connection with the Work, including but not limited to sales, use and, personal property taxes payable by or levied or assessed against the Owner. Xxxxxx or the Subcontractor. Where the law requires any such taxes to be stated and charged separately, the total price of all items included in the Work plus the amount of such taxes shall not exceed the Price. Monthly On or before the last day of each month the Estimate Subcontractor shall submit to Xxxxxx, in the form required by Xxxxxx, a written requisition for payment showing the proportionate value of the Work installed to that date, from which shall be deducted; **; all previous payments; and all charges for services, materials, equipment and other items furnished by Xxxxxx to or chargeable to the Subcontractor, and the balance of the amount of such requisition, as approved by Xxxxxx and the Architect and for which payment has been received by Xxxxxx from the Owner, shall be due and paid to the Subcontractor on or about ** . The obligation of Xxxxxx to make a payment under this Agreement, whether a progress or final payment, or for extras or change orders or Delays to the Work is subject to the express condition precedent of payment therefor by the Owner. If Xxxxxx has provided payment or performance bonds or a combination payment and performance bond, the obligation of Xxxxxx and its surety under any of those bonds to make any payment (whether a progress payment or final payment) to a claimant on that bond is similarly subject to the express condition precedent of payment therefor by the Owner.(*) The Subcontractor shall submit with its first requisition for payment a detailed schedule showing the breakdown of the Price into its various parts for use only as a basis of checking the Subcontractor's monthly requisitions. Xxxxxx reserves the right to advance the date of any payment (including the final payment) under this Agreement if, in its sole judgment, it becomes desirable to do so. The Subcontractor agrees that, if and when requested so to do by Xxxxxx, it shall furnish such information, evidence and substantiation as Xxxxxx may require with respect to the nature and extent of all obligations incurred by the Subcontractor for or in connection with the Work, all payments made by the Subcontractor thereon, and the amounts remaining unpaid, to whom and the reasons therefor. Final Final payment to the Subcontractor shall be Payment made only with funds received by Xxxxxx from the Owner, the Construction Lender or the Owner's Agent as final (*) SEE ADDI- payment for work under the general contract. Final payment TIONAL PROVI- to Xxxxxx by the Owner shall be an express condition SIONS, ITEM 33 precedent which must occur before Xxxxxx shall be ON PAGE 3E FOR obligated to make final payment to the Subcontractor. CLARIFICATIONS In addition, final payment by Xxxxxx to the Subcontractor shall not become due and payable until the following other express condition precedent have been met: (1) the completion and acceptance of the Work by Xxxxxx and the Architect; (2) provision by the Subcontractor of evidence satisfactory to Xxxxxx that there are no claims, obligations or liens outstanding or unsatisfied for labor, services, materials, equipment, taxes or other items performed, furnished, or incurred for or in connection with the work; and (3) execution and delivery by the Subcontractor, in a form satisfactory to Xxxxxx, of a General Release running to and in favor of Xxxxxx and the Owner. Should there prove to be any such claim, obligation or lien after final payment is made, the subcontractor shall refund to Xxxxxx all monies that Xxxxxx and/or the Owner shall pay in satisfying, discharging or defending against any such claim, obligation or lien or any action bought or judgment recovered thereon and all costs and expenses, including legal fees and disbursements, incurred in connection therewith. The final payment shall be due within ** days after all of these express conditions precedent have been met.(*) Payments If any claim or lien is made or filed with or Withheld against Xxxxxx, the Owner, the Project or the Promises by any person claiming that the Subcontractor or any subcontractor or other person under subcontract has failed to make payment for any labor, services, materials, equipment, taxes or other items or obligations furnished or incurred for or in connection with the Work, or if at any time there shall be evidence of such nonpayment or of any claim or lien for which, if established. Xxxxxx or the Owner might become liable and which is chargeable to the Subcontractor, or if the Subcontractor or any subcontractor or other person under subcontract causes damage to the Work or to any other work on the Project, or if the Subcontractor fails to perform or is otherwise in default under any of the terms or provisions of this Agreement. Xxxxxx shall have the right to retain from any payment then due or thereafter to become due an amount which it deems sufficient to (1) satisfy, discharge and/or defend against any such claim or lien or any action which may be brought or judgment which may be recovered thereon, (2) make good any such nonpayment, damage, failure or default, and (3) compensate Xxxxxx and the Owner for and indemnify them against any and all losses, liability, damages, costs and expenses, including legal fees and disbursements, which may be sustained or incurred by either or both of them in connection therewith. Xxxxxx shall have the right to apply and charge against the Subcontractor so much of the amount retained as may be required for the foregoing purposes. If the amount is insufficient therefor, the Subcontractor shall be liable for the difference and pay the same to Xxxxxx. Payments No payment (final or otherwise) made under or in etc., non- connection with this Agreement shall be conclusive Acceptance evidence of the performance of the Work or of this Agreement, in whole or in part, and no such payment shall be construed to be an acceptance of defective, faulty or improper work or materials nor shall it release the Subcontractor from any of its obligations under this Agreement; nor shall entrance and use by the Owner constitute acceptance of the Work or any part thereof. 2 3 Extension ARTICLE V. Should the Subcontractor be delayed, obstructed, of Time hindered or interfered with in the commencement, prosecution or completion of the work by any cause, including but not limited to any act, omission, neglect, negligence or default of Xxxxxx or of anyone employed by Xxxxxx, or by any other contractor or subcontractor on the Project, or by the Architect, the Owner or their contractors, subcontractors, agents or consultants, or by damage caused by fire or other casualty or by the combined action of workers or by governmental directive or order in no wise chargeable to the Subcontractor, or by any extraordinary conditions arising out of war or government regulations, or by any other cause beyond the control of and not due to any fault, neglect, act or omission of the Subcontractor, its officers, agents, employees, subcontractors or suppliers, then the Subcontractor shall be entitled to an extension of time for a period equivalent to the time lost by reason of any and all of the aforesaid causes; provided, however, that the Subcontractor shall not be entitled to any such extension of time unless the Subcontractor (1) notifies Xxxxxx in writing of the cause or causes of such delay, obstruction, hindrance or interference within forty eight (48) hours of the commencement thereof and (2) demonstrates that it could not have anticipated or avoided such delay, obstruction, hindrance or interference and has used all available means to minimize the consequences thereof. The Subcontractor agrees that it shall not be entitled to nor claim any cost reimbursement, compensation or damages for any delay, obstruction, hindrance or interference to the Work except to the extent that Xxxxxx is entitled to corresponding cost reimbursement, compensation or damages from the Owner under the Contract Documents for such delay, obstruction, hindrance or interference, and then only to the extent of the amount, if any, which Xxxxxx, on behalf of the Subcontractor, actually receives from the Owner on account of such delay, obstruction, hindrance or interference. Freight ARTICLE VI. The Subcontractor in making or ordering Charges and shipments shall not consign or have consigned materials, Shipments equipment or any other items in the name of Xxxxxx. Xxxxxx is under no obligation to make payment for charges on shipments made by or to the Subcontractor but may, at its option, pay such charges, in which case the Subcontractor shall reimburse Xxxxxx for the amount of such payments plus a service charge of twenty-five percent (25%) of the amount so paid. Dimensions ARTICLE VII. Notwithstanding the dimensions on the Plans, Specifications and other Contract Documents it shall be the obligation and responsibility of the Subcontractor to take such measurements as will insure the proper matching and fitting of the Work covered by this Agreement with contiguous work. Shop The Subcontractor shall prepare and submit to Xxxxxx such Drawings shop drawings as may be necessary to describe completely the details and construction of the Work. Approval of such shop drawings by Xxxxxx and/or the Architect shall not relieve the Subcontractor of its obligation to perform the Work in strict accordance with the Plans, Specifications, the Additional Provisions hereof and the other Contract Documents, nor of its responsibility for the proper matching and fitting of the Work with contiguous work and the coordination of the Work with other work being performed on the site, which obligation and responsibility shall continue until completion of the Work. Contiguous Should the proper and accurate performance of the Work Work hereunder depend upon the proper and accurate performance of other work not covered by this Agreement, the Subcontractor shall carefully examine such other work, determine whether it is in fit, ready and suitable condition for the proper and accurate performance of the Work hereunder, use all means necessary to discover any defects in such other work, and before proceeding with the Work hereunder, report promptly any such improper conditions and defects to Xxxxxx, in writing and allow Xxxxxx a reasonable time to have such improper conditions and defects remedied. Interpretation ARTICLE VIII. The Work hereunder is to be performed and of Plans and furnished under the direction and to the satisfaction of both Specifications the Architect and Xxxxxx. The decision of the Architect as to the true construction, meaning and intent of the Plans and Specifications shall be final and binding upon the parties hereto. Xxxxxx will furnish to the Subcontractor such additional information and Plans as may be prepared by the Architect to further the Work to be performed and furnished by the Subcontractor and the Subcontractor shall conform to and abide by the same. The Subcontractor shall not make any changes, additions and/or omissions in the Work except upon written order of Xxxxxx as provided in Article IX hereof. Change ARTICLE IX. Xxxxxx reserves the right, from time to time, Orders, whether the Work or any part thereof shall or shall not have Additions been completed, to make changes, additions and/or omissions in and the Work as it may deem necessary, upon written order to the Deductions Subcontractor. The value of the work to be changed, added or omitted shall be stated in said written order and shall be added to or deducted from the Price. The value of the work to be changed, added or omitted shall be determined by the lump sum or unit prices, if any, stipulated herein for such work. If no such prices are stipulated, such value shall be determined by whichever of the following methods or combination thereof Xxxxxx may elect: (a) By adding or deducting a lump sum or an amount determined by a unit price agreed upon between the parties hereto. PER SECTION "L" OF XXXXXX'X SPECIAL CONDITIONS Should the parties hereto be unable to agree as to the value of the work to be changed, added or omitted, the Subcontractor shall proceed with the work promptly under the written order of Xxxxxx from which order the stated value of the work shall be omitted, and the determination of the value of the work shall be referred to the Architect whose decision shall be final and binding upon the parties hereto. In the case of omitted work Xxxxxx shall have the right to withhold from payments due or to become due to the Subcontractor an amount which, in Xxxxxx'x opinion, is equal to the value of such work, until such time as the value thereof is determined by agreements or by the Architect as hereinabove provided. All changes, additions or omissions in the Work ordered in writing by Xxxxxx shall be deemed to be a part of the Work hereunder and shall be performed and furnished in strict accordance with all of the terms and provisions of this Agreement and the other Contract Documents. 3 4 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER - PHASE 1 CLEVELAND, OHIO CONTRACT NO. 6000H ADDITIONAL PROVISIONS 1. The "Price" referred to in Article IV of this Agreement as well as any Alternates, Unit Prices, hourly rates, separate prices, etc. stated in this Agreement shall remain in full force and effect for the duration of the Project (defined in Article I on Page 1). Also, prices established in any subsequent Change Orders to this Agreement shall remain in full force and effect for the same duration. 2. Subcontractor shall submit with each application for payment a sworn statement, in quadruplicate, setting forth the names and addresses of persons or firms who have been contracted with, or have furnished, or are furnishing materials or labor in connection with this Subcontract Agreement; also, showing opposite the name of each such person or firm the kind of material furnished or general nature of work performed, amount of contract, amount received to date, balance due and balance to become due. If Subcontractor's material is from stock, this sworn statement should recite that such material was taken from paid stock. If such affidavit (sworn statement) indicates indebtedness to sub-subcontractors and/or materialmen, Xxxxxx will require Affidavits and Waivers of Lien from sub-contractors and/or materialmen. 3. The Subcontractor must cooperate with and participate in the job safety program as summarized in the "Xxxxxx Safety Program". With reference to Item 10, a low velocity power actuated tool is defined as that where the stud or pin shall be caused to have a velocity not in excess of 300 feet per second when measured 6-1/2 feet from the muzzle of the fastening tool. Subcontractor is required to hold Xxxxxx harmless for any and all violation by the Subcontractor of safety requirements in Federal Register Volume 44, No. 29, Safety and Health Regulations for Construction. 4. Xxxxxx is a Federal Contractor and all subcontracts must conform with the requirements of Presidential Executive Orders 11246, 11375 and all other applicable laws, rules and regulations to ensure Equal Employment Opportunity. Subcontractors with field labor portions of $10,000.00 or more are required to: A. Execute a Monthly Utilization Report - Standard Form 257 for On-site Workforce. B. Send a notice of non-discrimination to all applicable unions. C. Comply to the Affirmative Action Program which provides a minimal, acceptable level of minority and female group employment (goals) for each and every trade and specific affirmative action steps to be followed during performance of the contract. Trade goal on this project is twenty-two and six tenths percent (22.6%) minority employment and seven percent (7%) female employment. (Contractor's and subcontractor's own workforce). 5. Subcontractor will exert best effort to achieve MBE/FBE participation. Cont'd on Page 3B -3A- 5 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER-PHASE 1 CLEVELAND, OHIO CONTRACT NO. 6000H ADDITIONAL PROVISIONS-Cont'd 6. All shanties that are pre-approved by Xxxxxx and installed by Subcontractor, or its subcontractors, ten feet or less from the building, shall be constructed of fireproof lumber, steel, masonry or other approved noncombustible materials, including wire glass. If valuable materials or extraordinary fire hazards are present, shanties installed more than ten feet from buildings shall also be fireproof. Before installing shanties, Xxxxxx'x Superintendent must approve construction and location. 7. Subcontractor will provide an experienced Superintendent or Xxxxxxx, familiar and experienced in work similar to the Work used on this Project as well as this Subcontractor's trade. Xxxxxx must approve of Subcontractor's Superintendent or Xxxxxxx. If for any reason Xxxxxx should request a change of personnel during the course of the job, the request will be honored immediately. Before Subcontractor replaces any Superintendent or Xxxxxxx, approval of Xxxxxx is required. 8. Should overtime work be required through Trade Contractor's negligence and/or inability to keep up with the pace of the Project, Trade Contractor will be charged for added costs to provide any temporary light and power, heat, hoisting services and other facilities during the premium time hours. 9. The Work includes any out-of-sequence work, required for the hoist bay area. In the event out-of-sequence work is required due to temporary facility and logistics in other areas, Subcontractor will accommodate Xxxxxx provided this does not pose a financial constraint on Subcontractor or schedule constraint. 10. Subcontractor is responsible for all necessary development of the Work to fulfill the intent of the Contract Documents for a complete and/or functioning system whether totally defined by the drawings and specifications or not. 11. This Project has been declared tax exempt by the Owner for all materials and labor associated with the permanent structure only in accordance with the tax laws of the State of Ohio. Sales tax, however, will be paid by this Trade Contractor for all materials and labor on this Project that does not fall underneath this requirement. 12. This Subcontractor does hereby waive any rights to direct payment from the Owner for any disputed amount or claim unless prior approved by Xxxxxx. 13. This Agreement shall be fully assignable to the Owner upon his request. It is agreed and understood that the Owner may accept said assignment at any time during the course of construction prior to final completion. This assignment would be effective upon acceptance by the Owner in writing and would accrue all rights, remedies and obligations to the Owner as are due Xxxxxx under this Agreement. 14. The Work of this Agreement shall include, but not be limited to, all materials, expediting labor, tools, equipment, scaffolding, shop drawings, catalog cuts, engineering, layout work, supplies, plant, freight, superintendence, transportation, temporary construction where required, compliance with all agencies (City, County, State and Federal as may be required), contributions, insurance, all taxes of any kind (excluding Ohio State Sales Tax for permanent Cont'd on Page 3C - 3B - 6 ** Confidential treatment requested pursuant to Rule 406 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER - PHASE 1 CLEVELAND, OHIO CONTRACT NO. 6000H ADDITIONAL PROVISIONS-CONT'D construction), all other services, facilities and things necessary to furnish and install B. P. 3A Glazed Aluminum Curtain Wall System Work in accordance with Contract Documents listed below, with the following clarifications: X. Xxxxxx'x Invitation to Bid dated 7/9/96. B. Contract Documents dated 10/22/96, EXHIBIT "B" (13 pages). C. Letter of Understanding/Project Mission Statement, EXHIBIT "C" (1 page). X. Xxxxxx'x Purchase Requisition No. 3A "Glazed Aluminum Curtain Wall System" dated 9/12/96, EXHIBIT "D" (7 pages). 15. The Cleveland Clinic Foundation Projects have initiated a labor agreement with all trades relative to this work. Same to be finalized by the end of January, 1997 and will be a part of this Agreement. 16. The Subcontract Price is as follows: Adjusted Base Bid ** * Add column @ bridge ** * Exterior (3 coats paint in lieu of 4) ** * Polycron paint @ interior ** * Aluminum doors in lieu of stainless steel ** * Eliminate molded corners @ interior glazing gaskets ** * Segmented Educ. Bldg. stair per SK-1 ** ------- Subtotal ** Negotiation Discount ** ------- Revised Bid ** Deduct Carnegie Bridge ** ------- SUBCONTRACT PRICE ** 17. The following understandings are included as part of this Subcontract Agreement: A. Clarification to item 10, page 5 of Purchase Requisition. Final cleaning will be at the direction of Xxxxxx. B. Subcontractor will furnish a parent company guarantee on a form acceptable to Xxxxxx with the signed Agreement. This parent company guarantee will be in effect through the warranty period. C. Subcontractor will provide an irrevocable letter of credit in the amount of ** to Xxxxxx to be in effect through the warranty period of the Project. Cont'd on Page 3D -3C- 7 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER - PHASE 1 CLEVELAND, OHIO CONTRACT NO. 6000H ADDITIONAL PROVISIONS - CONT'D. D. The curtainwall work is based on a mutually agreed upon Subcontractor's schedule dated 12/12/96, EXHIBIT "A" (3 pages). Since time is of the essence, Subcontractor will make every effort so that the mock-up, window and curtainwall test will occur one month earlier than shown on the Subcontractor's schedule dated 12/12/96. 18. The Architect has agreed on a ten (10) day door to door turn around time for shop drawings, provided that submittals are kept to a reasonable size package and submission is phased - Subcontractor to provide outline of shop drawing submission at the earliest time after award to facilitate schedule. 19. The Owner, Xxxxxx and Architect will schedule work meetings associated with the above submittals as required to facilitate the approval process. Meeting to be scheduled either in Cleveland and/or New York at Architect's office. 20. Subcontractor requested a forty-eight (48) hour turn around time for RFI's. Provided that the RFI's are reasonable, the Architect has agreed to meet this time frame. The forty-eight (48) hours to be work days only. 21. Subcontractor will review possibility of awarding the materials (aluminum) extrusion work to more then one manufacture to enhance schedule outcome and advise Xxxxxx if this is viable and beneficial to Project outcome. 22. Subcontractor is advised that Xxxxxx will employ an on-site exterior wall consultant (CDC) to periodically inspect and review shop drawings and on-site Work. Subcontractor agrees to afford the consultant reasonable time and access to all phases of this operation provided there is no delay to Subcontractor's schedule. 23. In addition to the indemnification required in Article XXIII of the Agreement, Subcontractor shall further hold Xxxxxx and the Owner harmless to the same degree for claims arising out of the Subcontractor's errors and omissions in the exterior wall design documents. Subcontractor shall provide to Xxxxxx evidence of product liability coverage in a least $5 million. Continuing evidence of the renewal of such coverage on its anniversary date must be provided, up to and until such date as legal actions may no longer be brought in accordance with applicable statutes. 24. Warranty for the Work is per item 13, page 5 of Purchase Requisition. 25. Subcontractor will engineer, fabricate and install the entire aluminum and curtain wall system. Subcontracting any portion of this scope other than manufacturing of the aluminum extrusions and supply of glass, will not be permitted without the expressed approval by Xxxxxx. In the event subcontracting any portion of the Work could be beneficial to the Project outcome, Subcontractor must seek written approval from Xxxxxx indicating specific benefit. Cont'd on Page 3E -3D- 8 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER - PHASE 1 CLEVELAND, OHIO CONTRACT NO. 6000H ADDITIONAL PROVISIONS - Cont'd 26. Subcontractor will work with other curtainwall trade contractors, i.e., stone work and support and precast work to coordinate shop drawing activities to minimize any problems, to allow for a smooth transition between each system. 27. Subcontractor will continually review and update the 12/12/96 schedule to enhance activities for the benefit of the Project, specifically as it relates to shop drawings, securing materials, fabrication, delivery for mock-up, delivery to jobsite and field installation of system on site. 28. All deliveries to jobsite and jobsite storage will be coordinated with Xxxxxx'x Project Superintendent. 29. Any material damaged during shipment will be replaced as expeditiously as practical to the Project site to minimize out-of-sequence work activities. 30. Subcontractor has committed to staff the Project and supervise all levels of this operation with qualified personnel meeting the approval of Xxxxxx and the Owner. A staffing chart will be submitted by Subcontractor for Xxxxxx'x concurrence. Any change to assigned staff, once approved by Xxxxxx, must be approved by Xxxxxx. 31. The quality level of any accepted alternates will be similar to the level of the original material specified. Subcontractor is aware and understands the Architect's quality level intent of the Project. 32. Subcontractor understands that Contract Documents do not indicate in depth details which may be required to build a complete system. Subcontractor has taken these items under full consideration and fulfilled the full intent for a complete system. 33. Subcontractor's acceptance of the expressed conditions precedent for payment terms is conditional on the understanding that: in the event Owner withholds progress and/or final payment, due to no fault of Subcontractor's work, Xxxxxx will immediately reformat requisition for payment in such fashion as to segregate monies due Subcontractor and follow for receipt of funds from the Owner for timely payment to Subcontractor. -3E- 9 ** Confidential treatment requested pursuant to Rule 406 ----------------------------------------------------------------------------------------------------------------------------------- FLOUR CITY ARCHITECTURAL METALS PRELIMINARY JOB SCHEDULE FOR XXXXXX CONSTRUCTION ----------------------------------------------------------------------------------------------------------------------------------- ID Task Name Duration Start Finish ----------------------------------------------------------------------------------------------------------------------------------- 43 Scheduling Assumptions: ** ** ** ** : ------------------------------------------------------------------------------- 44 1. two wk total appr'l turn around on all submittals ** ** ** ** : ------------------------------------------------------------------------------- 45 2. approved or approved as noted after 1st ** ** ** ** : ------------------------------------------------------------------------------- 46 submittal to release material production ** ** ** ** : ------------------------------------------------------------------------------- 47 3. 2nd subm for record only ** ** ** ** : ------------------------------------------------------------------------------- 48 4. RFI response within 48 hours ** ** ** ** : ------------------------------------------------------------------------------- 49 5. no changes to contract docs ** ** ** ** : ------------------------------------------------------------------------------- 50 6. schedule for trellises, soffits, canopies, ** ** ** ** : ------------------------------------------------------------------------------- 51 doors, stacks & vestibules will be ** ** ** ** : ------------------------------------------------------------------------------- 52 provided separately. ** ** ** ** : ------------------------------------------------------------------------------- 53 7. streets to be closed for crane setting (2) ** ** ** ** : ------------------------------------------------------------------------------- 54 8. sequence of bldgs per TCCO request ** ** ** ** : ------------------------------------------------------------------------------- 55 9. TCCO provide Architect Autocad files to ** ** ** ** : ------------------------------------------------------------------------------- 56 FCAM by December 18, 1996 ** ** ** ** : ------------------------------------------------------------------------------- 57 10. shape/design approval of windows & ** ** ** ** : ------------------------------------------------------------------------------- 58 curtain wall for job by early-mid Jan 1997 ** ** ** ** : ------------------------------------------------------------------------------- 59 11. the entire building structures shall be ready ** ** ** ** : ------------------------------------------------------------------------------- 60 for FCAM work to commence as follows: ** ** ** ** : ------------------------------------------------------------------------------- 61 BME Sep 1, 1997; Education Oct 1, 1997; & ** ** ** ** : ------------------------------------------------------------------------------- 62 Research Dec 1, 1997. ** ** ** ** : ------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- FLOUR CITY ARCHITECTURAL METALS PRELIMINARY JOB SCHEDULE FOR XXXXXX CONSTRUCTION ------------------------------------------------------------------------------------------------------------------- ID Task Name Duration Start Finish ------------------------------------------------------------------------------------------------------------------- 43 Scheduling Assumptions: ** ** ** ** : ------------------------------------------------------------------------------- 44 1. two wk total appr'l turn around on all submittals ** ** ** ** : ------------------------------------------------------------------------------- 45 2. approved or approved as noted after 1st ** ** ** ** : ------------------------------------------------------------------------------- 46 submittal to release material production ** ** ** ** : ------------------------------------------------------------------------------- 47 3. 2nd subm for record only ** ** ** ** : ------------------------------------------------------------------------------- 48 4. RFI response within 48 hours ** ** ** ** : ------------------------------------------------------------------------------- 49 5. no changes to contract docs ** ** ** ** : ------------------------------------------------------------------------------- 50 6. schedule for trellises, soffits, canopies, ** ** ** ** : ------------------------------------------------------------------------------- 51 doors, stacks & vestibules will be ** ** ** ** : ------------------------------------------------------------------------------- 52 provided separately. ** ** ** ** : ------------------------------------------------------------------------------- 53 7. streets to be closed for crane setting (2) ** ** ** ** : ------------------------------------------------------------------------------- 54 8. sequence of bldgs per TCCO request ** ** ** ** : ------------------------------------------------------------------------------- 55 9. TCCO provide Architect Autocad files to ** ** ** ** : ------------------------------------------------------------------------------- 56 FCAM by December 18, 1996 ** ** ** ** : ------------------------------------------------------------------------------- 57 10. shape/design approval of windows & ** ** ** ** : ------------------------------------------------------------------------------- 58 curtain wall for job by early-mid Jan 1997 ** ** ** ** : ------------------------------------------------------------------------------- 59 11. the entire building structures shall be ready ** ** ** ** : ------------------------------------------------------------------------------- 60 for FCAM work to commence as follows: ** ** ** ** : ------------------------------------------------------------------------------- 61 BME Sep 1, 1997; Education Oct 1, 1997; & ** ** ** ** : ------------------------------------------------------------------------------- 62 Research Dec 1, 1997. ** ** ** ** : ------------------------------------------------------------------------------- Project: CLEVELAND CLINIC Task Summary Rolled Up Progress Date: Thu 12/12/96 Progress Rolled Up Task Milestone Rolled Up Milestone -------------------------------------------------------------------------------- Page 3 -------------------------------------------------------------------------------- 10 ** Confidential treatment requested pursuant to Rule 406 ----------------------------------------------------------------------------------------------------------- FLOUR CITY ARCHITECTURAL METALS PRELIMINARY JOB SCHEDULE FOR XXXXXX CONSTRUCTION ----------------------------------------------------------------------------------------------------------- ID Task Name Duration Start Finish ------------------------------------------------------------------------------------------ 23 EDUCATION BLDG WINDOWS & C. WALL ** ** ** 24 shop drwgs, prepare & 1st subm ** ** ** 25 shop drwgs, approve & return ** ** ** 26 shop drwgs, submit for record ** ** ** 27 material production ** ** ** 28 unit assembly ** ** ** 29 field work, pre-unit installation ** ** ** 30 unit installation ** ** ** 31 caulking & trim ** ** ** 32 33 RESEARCH BLDG WINDOWS & C. WALL ** ** ** 34 shop drwgs, prepare & 1st subm ** ** ** 35 shop drwgs, approve & return ** ** ** 36 shop drwgs, submit for record ** ** ** 37 material production ** ** ** 38 unit assembly ** ** ** 39 field work, pre-unit installation ** ** ** 40 unit installation ** ** ** 41 caulking & trim ** ** ** 42 FLOUR CITY ARCHITECTURAL METALS PRELIMINARY JOB SCHEDULE FOR XXXXXX CONSTRUCTION ------------------------------------------------------------------------------------------------------------------------------------ ID Task Name ** ** ** ** ** ** ** ------------------------------------------------------------------------------------------------------------------------------------ 23 EDUCATION BLDG WINDOWS & C. WALL 24 shop drwgs, prepare & 1st subm 25 shop drwgs, approve & return 26 shop drwgs, submit for record 27 material production 28 unit assembly 29 field work, pre-unit installation 30 unit installation 31 caulking & trim 32 33 RESEARCH BLDG WINDOWS & C. WALL 34 shop drwgs, prepare & 1st subm 35 shop drwgs, approve & return 36 shop drwgs, submit for record 37 material production 38 unit assembly 39 field work, pre-unit installation 40 unit installation 41 caulking & trim 42 ------------------------------------------------------------------------------------------------------------------------------------ Project: CLEVELAND CLINIC Date: Thu 12/12/98 ------------------------------------------------------------------------------- Task Summary Rolled Up Progress Progress Rolled Up Task Milestone Rolled Up Milestone ------------------------------------------------------------------------------- Page 2 ------------------------------------------------------------------------------- 11 ** Confidential treatment requested pursuant to Rule 406 --------------------------------------------------------------------------------------------------------------------------------- FLOUR CITY ARCHITECTURAL METALS PRELIMINARY JOB SCHEDULE FOR XXXXXX CONSTRUCTION --------------------------------------------------------------------------------------------------------------------------------- 0 Task Name Duration Start Finish --------------------------------------------------------------------------------------------------------------------------------- 1 CURTAIN WALL WORK ** ** ** 2 SUBCONTRACT AWARD ** ** ** 3 4 MOCKUP, WINDOW & CURTAIN WALL ** ** ** 5 shop drwgs, prepare & 1st subm ** ** ** 6 shop drwgs, approve & return ** ** ** 7 shop drwgs, submit for record ** ** ** 8 material production ** ** ** 9 unit assembly ** ** ** 10 ship/erect/pretest ** ** ** 11 test ** ** ** 12 13 BME BUILDING WINDOWS & C. WALL ** ** ** 14 shop drwgs, prepare & 1st subm ** ** ** 15 shop drwgs, approve & return ** ** ** 16 shop drwgs, submit for record ** ** ** 17 material production ** ** ** 18 unit assembly ** ** ** 19 field work, pre-unit installation ** ** ** 20 unit installation ** ** ** 21 caulking & trim ** ** ** 22 --------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------------------------------------- Project: CLEVELAND CLINIC Task Summary Rolled Up Programs Date: Thu 12/12/96 Programs Rolled Up Task Milestone Rolled Up Milestone --------------------------------------------------------------------------------------------------------------------------------- Page 1 ------------------------------------------------------------------------------ 12 ------------------------------------------------------------------------------- Current Construction Document List CCF Health Sciences Center 22-Oct-96 Xxxxxx Constructions Co. 6000H -------------------------------------------------------------------------------- Number Title Revised Date Noted ---------------------------------------------------------------------------------------------- Drawings Architectural A-0000 Cover Sheet 10/14/96 Clean-up Set (CE-07) A-0001 Drawing Index 10/14/96 Clean-up Set (CE-07) A-0002 Symbols/Abbreviations 10/14/96 Clean-up Set (CE-07) A-0003 Egress Plans 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx 10/14/96 Clean-up Set (CE-07) A-0106 Penthouse Plan 10/14/96 Clean-up Set (CE-07) A-0107 Roof Plan 10/14/96 Clean-up Set (CE-07) A-0210 Basement Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0211 First Level Floor Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0212 Second Level Floor Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0213 Third Level Floor Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0213i Third & Fourth Level Interstitial-Education 10/14/96 Clean-up Set (CE-07) A-0214 Fourth Level Floor Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0215 Fifth Level Floor Plan-Education Wing 10/14/96 Clean-up Set (CE-07) A-0220 Basement Plan-Research Wing 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx-Xxxxxxxx Wing 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxx Xxxxx Xxxxx Xxxx-Xxxxxxxx Wing 9/13/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx-Xxxxxxxx Wing 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxx Xxxxx Xxxxx Xxxx-Xxxxxxxx Wing 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxx Xxxxx Xxxxx Xxxx-Xxxxxxxx Wing 10/14/96 Clean-up Set (CE-07) A-0226 Mechanical Equipment Level Floor Plan 10/14/96 Clean-up Set (CE-07) A-0310 RCP-Basement-Education Wing 10/14/96 Clean-up Set (CE-07) A-0311 RCP-First Level-Education Wing 10/14/96 Clean-up Set (CE-07) A-0312 RCP-Second Level-Education Wing 10/14/96 Clean-up Set (CE-07) A-0313 RCP-Third Level-Education Wing 10/14/96 Clean-up Set (CE-07) A-0314 RCP-Fourth Level-Education Wing 10/14/96 Clean-up Set (CE-07) A-0315 RCP-Fifth Level-Education Wing 10/14/96 Clean-up Set (CE-07) A-0320 RCP-Basement-Research Wing 10/14/96 Clean-up Set (CE-07) A-0321 RCP-First Level-Research Wing 10/14/96 Clean-up Set (CE-07) A-0322 RCP-Second Level-Research Wing 9/13/96 Clean-up Set (CE-07) A-0323 RCP-Third Level-Research Wing 10/14/96 Clean-up Set (CE-07) A-0324 RCP-Fourth Level-Research Wing 10/14/96 Clean-up Set (CE-07) A-0325 RCP-Fifth Level-Research Wing 10/14/96 Clean-up Set (CE-07) A-0400 Education Wing Atrium Core 10/14/96 Clean-up Set (CE-07) A-0410 Education Wing Atrium Grand Stair 10/14/96 Clean-up Set (CE-07) A-0411 Education Wing Atrium Grand Stair Details 10/14/96 Clean-up Set (CE-07) A-0420 Research Lobby Core 10/14/96 Clean-up Set (CE-07) ------------------------------------------------------------------------------- EXHIBIT "B" Page 1 of 13 13 ----------------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted ----------------------------------------------------------------------------------------------------------------------- A-0421 Elevator Shaft Details 10/14/96 Clean-up Set (CE-07) A-0440 Service Core - Plans and Details - Education 10/14/96 Clean-up Set (CE-07) A-0450 Service Stair - Plans and Details - Research 10/14/96 Clean-up Set (CE-07) A-0452 Misc. Stair Details 10/14/96 Clean-up Set (CE-07) A-0453 Misc. Interior Details 10/14/96 Clean-up Set (CE-07) A-0454 Data Core - Plans & Sections - Research 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx 000xx Xxxxxx Xxxxxx Xxxxx 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx 000xx Xxxxxx Xxxxxx Elevations/Sections 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx 000xx Xxxxxx Xxxxxx Details 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx 000xx Xxxxxx Xxxxxx Details 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx 000xx Xxxxxx Xxxxxx Details 10/14/96 Clean-up Set (CE-07) A-0470 NC Building Connection 10/14/96 Clean-up Set (CE-07) A-0500 5th Floor Raked Classroom - Education Wing 10/14/96 Clean-up Set (CE-07) A-0510 First Floor Classroom/Seminar - Education Wing 10/14/96 Clean-up Set (CE-07) A-0520 Fourth Floor Classroom - Education Wing 10/14/96 Clean-up Set (CE-07) A-0530 Fifth Floor Classroom - Education Wing 10/14/96 Clean-up Set (CE-07) A-0550 Fifth Floor Misc. Rooms - Education Wing 10/14/96 Clean-up Set (CE-07) A-0560 Toilet Room - Plans 10/14/96 Clean-up Set (CE-07) A-0561 Toilet Room - Elevations 10/14/96 Clean-up Set (CE-07) A-0562 Toilet Room - Elevations 10/14/96 Clean-up Set (CE-07) A-0570 Photography Department Plan 10/14/96 Clean-up Set (CE-07) A-0571 Photography Department Elevations 10/14/96 Clean-up Set (CE-07) A-0580 Research Entry 10/14/96 Clean-up Set (CE-07) A-0600 Interior Elevations - Education/Research Corridors 10/14/96 Clean-up Set (CE-07) A-0610 Interior Elevations & Plans - Commons 10/14/96 Clean-up Set (CE-07) A-0620 Interior Elevations - Commons 10/14/96 Clean-up Set (CE-07) A-0630 Rail Details - Commons 10/14/96 Clean-up Set (CE-07) A-0635 Research Wing Elevations & Details - Commons 10/14/96 Clean-up Set (CE-07) A-0640 Educ. Lvls 2,3, & 4 Interior Elevations 10/14/96 Clean-up Set (CE-07) A-0650 Interior Elevations - Library Third Floor 10/14/96 Clean-up Set (CE-07) A-0660 Interior Elevations - Library Stair 10/14/96 Clean-up Set (CE-07) A-0661 Library Stair & Guard Rail Details 10/14/96 Clean-up Set (CE-07) A-0700 Building Section/Elevations 10/14/96 Clean-up Set (CE-07) A-0710 Building Elevations 10/14/96 Clean-up Set (CE-07) A-0720 Building Elevations 10/14/96 Clean-up Set (CE-07) A-0800 Building Section: North/South Education 10/14/96 Clean-up Set (CE-07) A-0810 Building Section: Atrium With Bridge 10/14/96 Clean-up Set (CE-07) A-0820 Building Section: Atrium and Library Stair 10/14/96 Clean-up Set (CE-07) A-0830 Building Section: East/West Education 10/14/96 Clean-up Set (CE-07) A-0840 Building Section: East/West Research 10/14/96 Clean-up Set (CE-07) A-0850 Building Section: East End/Research 10/14/96 Clean-up Set (CE-07) A-0860 Building Section: Research Lobby/Shaft 10/14/96 Clean-up Set (CE-07) A-0870 Building Section: Commons/West End 10/14/96 Clean-up Set (CE-07) A-0900 Detailed Building Elevations: Education Wing 10/14/96 Clean-up Set (CE-07) A-0910 Detailed Building Elevations: Atrium 10/14/96 Clean-up Set (CE-07) A-0920 Detailed Building Elevations: Education Wing 10/14/96 Clean-up Set (CE-07) A-0930 Detailed Building Elevations: Education Wing 10/14/96 Clean-up Set (CE-07) A-0940 Detailed Building Elevations: Research & Ed. Wings 10/14/96 Clean-up Set (CE-07) A-0950 Detailed Building Elevations: Research Wing 10/14/96 Clean-up Set (CE-07) ----------------------------------------------------------------------------------------------------------------------- 14 ------------------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted ------------------------------------------------------------------------------------------------------------------------- A-0980 Detailed Building Elevations: Research Wing 10/14/96 Clean-up Set (CE-07) A-0990 Detail Elevation - Typical Exterior Truss Wall 10/14/96 Clean-up Set (CE-07) A-1000 Wall Sections - Education Wing 10/14/96 Clean-up Set (CE-07) A-1010 Wall Sections - Education Wing 10/14/96 Clean-up Set (CE-07) A-1020 Wall Sections - Research Wing 10/14/96 Clean-up Set (CE-07) A-1030 Wall Sections - Research Wing 10/14/96 Clean-up Set (CE-07) X-0000 Xxxx & Xxxxxxx - Xxxxxxx/Xxxxxxx 10/14/96 Clean-up Set (CE-07) A-1110 Exterior Wall Plan Details - Education Wing 10/14/96 Clean-up Set (CE-07) A-1120 Exterior Wall Plan Details - Research Wing 10/14/96 Clean-up Set (CE-07) A-1130 Exterior Wall Plan Details - Education/Research Wing 10/14/96 Clean-up Set (CE-07) A-1131 Exterior Wall Plan Details - Education/Research Wing 10/14/96 Clean-up Set (CE-07) A-1132 Expansion Joint - Educ/Research @ Roof 10/14/96 Clean-up Set (CE-07) A-1140 Exterior Wall Plan Details - Misc. Curtainwall 10/14/96 Clean-up Set (CE-07) A-1150 Exterior Wall Section Details - Typical Wall 7/10/96 Clean-up Set (CE-07) A-1160 Exterior Wall Section Details - Curtainwall & Drum 10/14/96 Clean-up Set (CE-07) A-1161 Exterior Wall Section Details - Curtain Wall 10/14/96 Clean-up Set (CE-07) A-1170 Terrace/Trellis Details 10/14/96 Clean-up Set (CE-07) A-1171 Door Sill Details 10/14/96 Clean-up Set (CE-07) A-1180 Ext. Wall Section Details 10/14/96 Clean-up Set (CE-07) A-1190 Typical Parapet Details 10/14/96 Clean-up Set (CE-07) A-1191 Exterior Wall Details 10/14/96 Clean-up Set (CE-07) A-1192 Expansion Joint Details 10/14/96 Clean-up Set (CE-07) A-1193 Exhaust Stack Details 10/14/96 Clean-up Set (CE-07) A-1194 Roof Drain Details 10/14/96 Clean-up Set (CE-07) A-1195 Misc. Roof Details 10/14/96 Clean-up Set (CE-07) A-1200 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1210 Millwork Details - Raked Classroom 10/14/96 Clean-up Set (CE-07) A-1211 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1212 Millwork Details - First Floor Classrooms 10/14/96 Clean-up Set (CE-07) A-1213 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1220 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1221 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1222 Millwork Details 10/14/96 Clean-up Set (CE-07) X-0000 Xxxxxxxx Xxxxxxx - 0xx Xxxxx Library Service Desk 10/14/96 Clean-up Set (CE-07) A-1224 Millwork Details - 4th Floor Library Service Desk 10/14/96 Clean-up Set (CE-07) A-1225 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1226 Millwork Details 10/14/96 Clean-up Set (CE-07) A-1230 Interior Details 10/14/96 Clean-up Set (CE-07) A-1231 Misc. Interior Details 10/14/96 Clean-up Set (CE-07) A-1232 Misc. Interior Details - 1st Floor 10/14/96 Clean-up Set (CE-07) A-1233 Misc. Interior Details - 2nd Floor 10/14/96 Clean-up Set (CE-07) A-1234 Misc. Interior Details - 3rd Floor 10/14/96 Clean-up Set (CE-07) A-1235 Misc. Interior Details - 4th Floor 10/14/96 Clean-up Set (CE-07) A-1238 Misc. Interior Details - 5th Floor 10/14/96 Clean-up Set (CE-07) A-1240 Interior Wall Sections - Education Wing 10/14/96 Clean-up Set (CE-07) A-1241 Interior Wall Sections - Education Wing 10/14/96 Clean-up Set (CE-07) A-1242 Interior Wall Sections - Education Wing 10/14/96 Clean-up Set (CE-07) A-1250 Ceiling Details 10/14/96 Clean-up Set (CE-07) A-1251 Ceiling Details 10/14/96 Clean-up Set (CE-07) ------------------------------------------------------------------------------------------------------------------------ 15 ------------------------------------------------------------------------------------------------------------------------------ Number Title Revised Date Noted ------------------------------------------------------------------------------------------------------------------------------ A-1252 Ceiling Details 7/31/96 Clean-up Set (CE-07) A-1253 Research First & Second Floor RCP Details 10/14/96 Clean-up Set (CE-07) A-1254 Research First & Second Floor RCP Details 10/14/96 Clean-up Set (CE-07) A-1300 Ribbon Window Details 10/14/96 Clean-up Set (CE-07) A-1310 Curtainwall Drum Misc. Details 10/14/96 Clean-up Set (CE-07) A-1320 Curtainwall @ Atrium Details 10/14/96 Clean-up Set (CE-07) A-1340 Isonometric @ Ribbon Window 10/14/96 Clean-up Set (CE-07) A-1350 Isonometric @ Curtainwall 10/14/96 Clean-up Set (CE-07) A-1400 Door Schedule 10/14/96 Clean-up Set (CE-07) A-1410 Door & Frame Types 10/14/96 Clean-up Set (CE-07) A-1420 Door & Frame Details 10/14/96 Clean-up Set (CE-07) A-1430 Misc. Door Details 10/14/96 Clean-up Set (CE-07) A-1500 Partition Types 10/14/96 Clean-up Set (CE-07) A-B0002 BME Building Context Plan & Drwg. List 8/2/96 Addendum No. 2 A-B0230 BME/Biostat - Basement 10/14/96 Clean-up Set (CE-07) A-B0231 BME/Biostat - First Floor 10/14/96 Clean-up Set (CE-07) A-B0232 BME/Biostat - Second Floor 10/14/96 Clean-up Set (CE-07) A-B0233 BME/Biostat - Third Floor 10/14/96 Clean-up Set (CE-07) A-B0233 BME/Biostat - Third Floor/Interstitial 10/14/96 Clean-up Set (CE-07) A-B0234 BME/Biostat - Fourth Floor 10/14/96 Clean-up Set (CE-07) A-B0234 BME/Biostat - Fourth Floor/Interstitial 10/14/96 Clean-up Set (CE-07) A-B0235 BME/Biostat - Fifth Floor 10/14/96 Clean-up Set (CE-07) A-B0235 BME/Biostat - Fifth Floor/Interstitial 10/14/96 Clean-up Set (CE-07) A-B0236 BME/Biostat - Penthouse 10/14/96 Clean-up Set (CE-07) A-B0237 BME/Biostat - Roof Plan 10/14/96 Clean-up Set (CE-07) A-B0400 BME/Core Plans 10/14/96 Clean-up Set (CE-07) A-B0401 BME/Core Plans 10/14/96 Clean-up Set (CE-07) A-B0402 BME/Core Sections 10/14/96 Clean-up Set (CE-07) A-B0403 BME/Atrium Stair Sections 10/14/96 Clean-up Set (CE-07) A-B0410 BME/Core Plans 10/14/96 Clean-up Set (CE-07) A-B0411 BME/Core Plans 10/14/96 Clean-up Set (CE-07) A-B0420 BME/Stair Plans 10/14/96 Clean-up Set (CE-07) A-B0470 Pedestrian Bridge Plans & Elevations 10/14/96 Clean-up Set (CE-07) A-B0471 Pedestrian Bridge Details 10/14/96 Clean-up Set (CE-07) A-B0472 Pedestrian Bridge Details 10/14/96 Clean-up Set (CE-07) A-B0473 Pedestrian Bridge Details 10/14/96 Clean-up Set (CE-07) A-B0480 Demo & Scope of Work - Sherwin Entry 8/2/96 Addendum No. 2 A-B0481 Demo Plan @ Sherwin Entry - Structural 8/2/96 Addendum No. 2 A-B0490 Demo & Scope of Work @ Lab Med Xxxx 0/0/00 Xxxxxxxx Xx. 0 X-X0000 00xx Xxxxxx Xxxxxx - Plans/Sections/Elevations 10/14/96 Clean-up Set (CE-07) A-B0610 BME/Interior Elev. @ Atrium 10/14/96 Clean-up Set (CE-07) A-B0700 Elevations 10/14/96 Clean-up Set (CE-07) A-B0750 BME/West Elevation 10/14/96 Clean-up Set (CE-07) A-B0760 BME/East Elevation 10/14/96 Clean-up Set (CE-07) A-B0770 BME/North & South Elevations 10/14/96 Clean-up Set (CE-07) A-B0800 BME/North & South Sections 10/14/96 Clean-up Set (CE-07) A-B0810 BME/East & West Sections 10/14/96 Clean-up Set (CE-07) A-B0820 BME/East & West Sections 10/14/96 Clean-up Set (CE-07) A-B0830 BME/Atrium & 96th St. Bridge Section 10/14/96 Clean-up Set (CE-07) ------------------------------------------------------------------------------------------------------------------------------ 16 ---------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted ---------------------------------------------------------------------------------------------------------- A-B0900 BME/West Elevation Details 10/14/96 Clean-up Set (CE-07) A-B0910 BME/East Elevation Details 10/14/96 Clean-up Set (CE-07) A-B0920 BME/North & South Elevation Details 10/14/96 Clean-up Set (CE-07) A-B1000 BME/Wall Sections 10/14/96 Clean-up Set (CE-07) A-B1010 BME/Wall Sections 10/14/96 Clean-up Set (CE-07) A-B1020 BME/Wall Sections 10/14/96 Clean-up Set (CE-07) A-B1030 BME/Wall Sections 10/14/96 Clean-up Set (CE-07) A-B1050 BME/Wall Section Details 10/14/96 Clean-up Set (CE-07) A-B1100 BME Building Plan Details 10/14/96 Clean-up Set (CE-07) A-B1101 BME Plan Details - Floor 1 10/14/96 Clean-up Set (CE-07) A-B1102 BME Plan Details - Floor 2, 3, & 4 10/14/96 Clean-up Set (CE-07) A-B1109 BME Plan Details 10/14/96 Clean-up Set (CE-07) A-B1110 Seismic Joint - BME/Research Details 10/14/96 Clean-up Set (CE-07) A-B1111 Seismic Joint - BME/Research Details 10/14/96 Clean-up Set (CE-07) A-B1112 Seismic Joint - BME/Research Details 10/14/96 Clean-up Set (CE-07) Audio Visual AV-1 Audiovisual Systems Conduit Plans 6/17/96 GMP Bid Set AV-2 Audiovisual Systems Diagrams & Details - 1 6/17/96 GMP Bid Set AV-3 Audiovisual Systems Diagrams & Details - 2 6/17/96 GMP Bid Set AV-4 Audiovisual Systems Details 6/17/96 GMP Bid Set Civil C-100 Demolition Plan 6/17/96 GMP Bid Set C-101 Layout Plan 6/17/96 GMP Bid Set C-102 Paving Plan 6/17/96 GMP Bid Set C-103 Grading Plan 6/17/96 GMP Bid Set C-104 Storm Sewer Plan 6/17/96 GMP Bid Set C-105 Site Details 6/17/96 GMP Bid Set SP-000 Existing Survey 6/17/96 GMP Bid Set Electrical E-001 Symbol Legend 10/11/96 Clean-up Set (CE-07) E-002 Lighting Fixture Schedule 10/11/96 Clean-up Set (CE-07) E-100 Site Electrical Plan 10/11/96 Clean-up Set (CE-07) E-106 Roof Plans - Lightning Protection 10/11/96 Clean-up Set (CE-07) E-208 Bamnt Electrical Connection Plan - Exist. NC Bldg 10/11/96 Clean-up Set (CE-07) E-210 Basement Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-211 First Level Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-212 Second Level Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-213 Third Level Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-213i Third & Fourth Lvl Interstitial Power Plans - Educ. 10/11/96 Clean-up Set (CE-07) E-214 Fourth Level Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-215 Fifth Level Power Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-220a Basement Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) E-220b Basement Power Plan Area B - Research Wing 10/11/96 Clean-up Set (CE-07) E-221a First Level Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx Xxxxx Xxxx Xxxx X - Research Wing 10/11/96 Clean-up Set (CE-07) E-222a Second Level Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx Xxxx X - Research Wing 10/11/96 Clean-up Set (CE-07) ---------------------------------------------------------------------------------------------------------- 17 -------------------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted -------------------------------------------------------------------------------------------------------------------------- E-223a Third Level Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx Xxxxx Xxxx Xxxx X - Research Wing 10/11/96 Clean-up Set (CE-07) E-223l Third Level Interstitial Power & Communications 10/11/96 Clean-up Set (CE-07) E-224a Fourth Level Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx Xxxx X - Research Wing 10/11/96 Clean-up Set (CE-07) E-224l Fourth Level Interstitial Power & Communications 10/11/96 Clean-up Set (CE-07) E-225 Fifth Level Shelf Space Power Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-226a Penthouse Level Power Plan Area A - Research Wing 10/11/96 Clean-up Set (CE-07) E-226b Penthouse Level Power Plan Area B - Research Wing 10/11/96 Clean-up Set (CE-07) E-230 Basement Power Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-223i Third Level Inter. Power Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-235 Fifth Level Power Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-236 Roof Power Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-310 Basement Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-311 First Level Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-312 Second Level Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-313 Third Level Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-313i Third & Fourth Lvl. Interstitial Lighting Plan 10/11/96 Clean-up Set (CE-07) E-314 Fourth Level Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-315 Fifth Level Lighting Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-320 Basement Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-321 First Level Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-322 Second Level Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-323 Third Level Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-323l Third Level Inter. Lighting Plans - Research Wing 10/11/96 Clean-up Set (CE-07) E-324 Fourth Level Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-324i Fourth Level Inter. Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-325 Fifth Level Lighting Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-326 Penthouse Lighting Plan - Educ. & Research 10/11/96 Clean-up Set (CE-07) E-330 Basement Lighting Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-333l Third-Lvl. Interstitial Lighting Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-335 Fifth Level Lighting Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-410 Basement Signal & Comm. Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-411 First Level Signal & Comm. Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-412 Second Level Signal & Comm. Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-413 Third Level Signal & Comm. Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-413l Third & Fourth Lvl. Interstitial Signal & Comm. 10/11/96 Clean-up Set (CE-07) E-414 Fourth Level Signal & Comm. Plan - Education Wing 10/11/96 Clean-up Set (CE-07) E-415 Fifth Level Signal & Comm. Plan -Education Wing 10/11/96 Clean-up Set (CE-07) E-420 Basement Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-421 First Level Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-422 Second Level Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-423 Third Level Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-423l Third Lvl. Interstitial Signal & Comm. - Research 10/11/96 Clean-up Set (CE-07) E-424 Fourth Level Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-424l Fourth Lvl. Interstitial Signal & Comm. - Research 10/11/96 Clean-up Set (CE-07) E-425 Fifth Level Signal & Comm. Plan - Research Wing 10/11/96 Clean-up Set (CE-07) E-426 Penthouse Signal & Comm. Plan - Educ./Research 10/11/96 Clean-up Set (CE-07) E-430 Basement Signal & Comm. Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) -------------------------------------------------------------------------------------------------------------------------- 18 --------------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted --------------------------------------------------------------------------------------------------------------------- E-4331 Third Lvl. Interstitial Signal & Comm. - BME 10/11/96 Clean-up Set (CE-07) E-435 Fifth Level Signal & Comm. Plan - BME/Biostat Wing 10/11/96 Clean-up Set (CE-07) E-501 Electrical Construction Details 10/11/96 Clean-up Set (CE-07) E-601 Panelboard Sched. - Basement Level - Research Wing 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx Research Wing 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx Part A Research Wing 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx Part B Research Wing 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx Part A Research Wing 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx Part B Research Wing 10/11/96 Clean-up Set (CE-07) E-607 Panel Schedule - 4th Lvl Part A & Inter. Xxxx.XX's 10/11/96 Clean-up Set (CE-07) E-607.1 Panelboard Sched. - 4th Level Part B Research Wing 10/11/96 Clean-up Set (CE-07) E-608 Panel Schedule - 1st & 2nd Lvl - Education 10/11/96 Clean-up Set (CE-07) E-609 Panel Schedule - 3rd & 4th Lvl - Education 10/11/96 Clean-up Set (CE-07) E-610 Panel Schedule - Inter Elec. Closets & 5th - Educati 10/11/96 Clean-up Set (CE-07) E-611 Distribution Panelboard Sched. - Type LDPN, LDPE 10/11/96 Clean-up Set (CE-07) E-612 Distribution Panelboard Sched. - Type RDPN 10/11/96 Clean-up Set (CE-07) E-613 Distribution & Power Panelboard Schedule 10/11/96 Clean-up Set (CE-07) E-614 Motor Control Center Schedules & Wiring Diagrams 10/11/96 Clean-up Set (CE-07) E-615 Unit Substation & Generator Switchboard Schedule 10/11/96 Clean-up Set (CE-07) E-616 Unit Substation/Generator Switchboard Schedule 10/11/96 Clean-up Set (CE-07) X-000 Xxxxxxxxxx Xxxxx. - 0xx Xxxxx XXX 10/11/96 Clean-up Set (CE-07) E-618 Panel Schedule - 3rd Lvl Inter.Elec Rooms - BME 10/11/96 Clean-up Set (CE-07) E-701 Network Services LAN/PDS Systems/Equip - Educ. 10/11/96 Clean-up Set (CE-07) E-810 Power One Line Diagram - 11.4KV Primary Service 10/11/96 Clean-up Set (CE-07) E-820 Power One Line Diagram 480v Secondary Distribution 10/11/96 Clean-up Set (CE-07) E-821 Power One Line Diagram - Bldg. Distribution Resear 10/11/96 Clean-up Set (CE-07) E-822 Power One Line Diagram - Bldg. Distribution - Educ. 10/11/96 Clean-up Set (CE-07) E-823 Power One Line Diagram - Bldg. Distribution - Educ. 10/11/96 Clean-up Set (CE-07) E-830 Power One Line Diagram - Primary Dist. - BME 10/11/96 Clean-up Set (CE-07) E-831 Power One Line Diagram - BME/Biostat Wing - North 10/11/96 Clean-up Set (CE-07) E-832 Power One Line Diagram - BME/Biostat Wing - South 10/11/96 Clean-up Set (CE-07) E-910 Fire Alarm System Riser and Wiring Diagram 10/11/96 Clean-up Set (CE-07) E-920 Risers - Network Services/Structured Cabling 10/11/96 Clean-up Set (CE-07) E-930 Riser Diagram - Broadband LAN Cabling System 10/11/96 Clean-up Set (CE-07) Food Service FS1.01 Food Service Equip - Plan & Schedule 6/17/96 GMP Bid Set FS1.02 Food Service Equipment - Electrical Spot Connection 6/17/96 GMP Bid Set FS1.03 Food Service Equipment - Mech Spot Connection Plan 6/17/96 GMP Bid Set FS1.04 Food Service Equip - Special Conditions Plan 6/17/96 GMP Bid Set FS1.05 Food Service Equip - Elevations & Sections 6/17/96 GMP Bid Set FS1.06 Food Service Equip - Elevations & Sections 6/17/96 GMP Bid Set FS1.07 Food Service Equip - Utility Load Schedule 6/17/96 GMP Bid Set FS1.08 Food Service Equip - Utility Load Schedule 6/17/96 GMP Bid Set FS1.09 Food Service Equip - Utility Load Schedule 6/17/96 GMP Bid Set FS1.10 Food Service Equip - Utility Load Schedule 6/17/96 GMP Bid Set Laboratory K-021 Abbrev., Symbols, Schedules & General Notes 10/11/96 Clean-up Set (CE-07) K-022 Door Schedule 10/11/96 Clean-up Set (CE-07) --------------------------------------------------------------------------------------------------------------------- 19 --------------------------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted --------------------------------------------------------------------------------------------------------------------------------- K-120 Basement Level Plan 10/11/96 Clean-up Set (CE-07) K-121 First Level Plan 10/11/96 Clean-up Set (CE-07) K-122 Second Level Plan 10/11/96 Clean-up Set (CE-07) K-123 Third Level Plan 10/11/96 Clean-up Set (CE-07) K-123l Third Level Interstitial Plan 10/11/96 Clean-up Set (CE-07) K-124 Fourth Level Plan 10/11/96 Clean-up Set (CE-07) K-124l Fourth Level Interstitial Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx Xxxxx Xxxx - Xxxx 10/11/96 Clean-up Set (CE-07) K-320a Basement - West - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) K-320b Basement - East - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Cabinet & Equipment Plan 10/11/96 Clean-up Set (CE-07) K-420a Basement - West - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) K-420b Basement - East - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) X-000x Xxxxxx Xxxxx - Xxxx - Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) K-429 Enlarged Reflected Ceiling Plan 10/11/96 Clean-up Set (CE-07) K-521 Building Laboratory Transverse Section A 10/11/96 Clean-up Set (CE-07) K-522 Building Laboratory Transverse Section B 10/11/96 Clean-up Set (CE-07) K-523 Building Laboratory Longitudinal Section C 10/11/96 Clean-up Set (CE-07) K-524 Building Laboratory Longitudinal Section D 10/11/96 Clean-up Set (CE-07) K-525 Partial Building Sections E & F 10/11/96 Clean-up Set (CE-07) K-526 Partial Building Sections G & H 10/11/96 Clean-up Set (CE-07) K-621a First Level Interior Elevations 10/11/96 Clean-up Set (CE-07) K-621b First Level Interior Elevations 10/11/96 Clean-up Set (CE-07) K-622a Second Level Laboratory Elevations 10/11/96 Clean-up Set (CE-07) K-622b Second Level Corridor Elevations 10/11/96 Clean-up Set (CE-07) K-622c Second Level Lab Entry Elevations 10/11/96 Clean-up Set (CE-07) K-623a Third & Fourth Level Laboratory Elevations 10/11/96 Clean-up Set (CE-07) K-623b Third Level Corridor Elevations 10/11/96 Clean-up Set (CE-07) K-623c Third Level Lab Entry Elevations 10/11/96 Clean-up Set (CE-07) --------------------------------------------------------------------------------------------------------------------------------- 20 -------------------------------------------------------------------------------- Number Title Revised Date Noted -------------------------------------------------------------------------------- K-629a Tissue Culture & Misc. Specialty Rooms 10/11/96 Clean-up Set(CE-07) K-629b Meeting Room Detail Plans & Elevations 10/11/96 Clean-up Set(CE-07) K-721 Typical Lab Bench Elevations 10/11/96 Clean-up Set(CE-07) K-722 Typical Lab Bench Sections 10/11/96 Clean-up Set(CE-07) K-723 Cabinet Types 10/11/96 Clean-up Set(CE-07) K-724 Cabinet Types & Details 10/11/96 Clean-up Set(CE-07) K-725 Cabinet Details 10/11/96 Clean-up Set(CE-07) K-820 Basement Floor Finish Plan 10/11/96 Clean-up Set(CE-07) K-821 First Floor Finish Plan 10/11/96 Clean-up Set(CE-07) K-822 Second Floor Finish Plan 10/11/96 Clean-up Set(CE-07) K-823 Third Floor Finish Plan 10/11/96 Clean-up Set(CE-07) X-000 Xxxxxx Xxxxx Finish Plan 10/11/96 Clean-up Set(CE-07) K-921 Standard Partitions and Framing 10/11/96 Clean-up Set(CE-07) K-922 Door & Window Details 10/11/96 Clean-up Set(CE-07) K-923 Automatic Door & Misc. Details 10/11/96 Clean-up Set(CE-07) K-924 Interior Finish & Misc. Details 10/11/96 Clean-up Set(CE-07) K-925 Interior Finish Details 10/11/96 Clean-up Set(CE-07) K-926 Ceiling Details 10/11/96 Clean-up Set(CE-07) Landscape CDL-100 Key Plan 6/17/96 GMP Bid Set CDL-110 Landscape Plan 6/17/96 GMP Bid Set CDL-115 Alternate Landscape Layout Plan 6/17/96 GMP Bid Set CDL-120 Grading and Drainage Plan 6/17/96 GMP Bid Set CDL-130 Paving Plan 6/17/96 GMP Bid Set CDL-140 Tree Planting Plan 6/17/96 GMP Bid Set CDL-141 Planting Plan (East of Col. Line R7) 6/17/96 GMP Bid Set CDL-142 Planting Plan (West of Col. Line R8) 6/17/96 GMP Bid Set CDL-143 Xxxxxx Garden 6/17/96 GMP Bid Set CDL-144 Plant Schedule and Planting Details 6/17/96 GMP Bid Set DDL-150 Site Details 6/17/96 GMP Bid Set DDL-160 Irrigation Plan 7/24/96 Xxxxxxxx Xx. 0 XXX-000 Xxxxxxxxxx Details 7/24/96 Xxxxxxxx Xx. 0 Xxxxxxxxxx X-000 Education Basement Plan Duct Work 10/11/96 Clean-up Set(CE-07) H-211 Education First Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-212 Education Second Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-213 Education Third Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-2131 Education Level Three/Four Interstitial Duct Work 10/11/96 Clean-up Set(CE-07) H-214 Education Fourth Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-215 Education Fifth Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-220 Research Basement Plan 10/11/96 Clean-up Set(CE-07) H-225 Research Fifth Floor Duct Work 10/11/96 Clean-up Set(CE-07) H-226 Mechanical Equipment Floor Plan 10/11/96 Clean-up Set(CE-07) H-231 BME Building Level One 10/11/96 Clean-up Set(CE-07) H-232 BME Building Second Floor 10/11/96 Clean-up Set(CE-07) H-233 BME Building Third Floor 10/11/96 Clean-up Set(CE-07) X-000 XXX Xxxxxxxx Xxxxxx Xxxxx 00/00/00 Xxxxx-xx Xxx(XX-00) X-000 XXX Building Fifth Floor 10/11/96 Clean-up Set(CE-07) -------------------------------------------------------------------------------- 21 ------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted ------------------------------------------------------------------------------------------------------- H-236 BME Building Roof Level 10/11/96 Clean-up Set (CE-07) H-421a Research First Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-421b Research First Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-422a Research Second Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-422b Research Second Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-423a Research Third Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-423b Research Third Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-424a Research Fourth Floor Duct Work 10/11/96 Clean-up Set (CE-07) H-424b Research Fourth Floor Duct Work 10/11/96 Clean-up Set (CE-07) HP-001 Symbol Legend 10/11/96 Clean-up Set (CE-07) HP-100 Site Plan 10/11/96 Clean-up Set (CE-07) HP-101 Underground Piping Profiles 10/11/96 Clean-up Set (CE-07) HP-108 Roof Plan 10/11/96 Clean-up Set (CE-07) HP-240 Basement - NC Building 10/11/96 Clean-up Set (CE-07) XX-000 Xxxxx Xxxxx - XX Building 10/11/96 Clean-up Set (CE-07) HP-430 NC-NB Tunnel Revisions 10/11/96 Clean-up Set (CE-07) HP-440 Research Main Mechanical Shaft 10/11/96 Clean-up Set (CE-07) HP-441 Education Wing shaft Sections - South 10/11/96 Clean-up Set (CE-07) HP-442 Education Wing Shaft Sections - North 10/11/96 Clean-up Set (CE-07) HP-443 BME Main Mechanical Shaft 10/11/96 Clean-up Set (CE-07) HP-444 BME Main Mechanical Shaft 10/11/96 Clean-up Set (CE-07) HP-460 Bridge Plans and Sections 10/11/96 Clean-up Set (CE-07) HP-500 Details 10/11/96 Clean-up Set (CE-07) HP-501 Details 10/11/96 Clean-up Set (CE-07) HP-502 Details 10/11/96 Clean-up Set (CE-07) HP-504 Research Sections 10/11/96 Clean-up Set (CE-07) HP-506 Mechanical Room Sections 10/11/96 Clean-up Set (CE-07) HP-507 Sections and Diagrams 10/11/96 Clean-up Set (CE-07) HP-508 Sections 10/11/96 Clean-up Set (CE-07) HP-600 Equipment Schedules 10/11/96 Clean-up Set (CE-07) HP-601 Equipment Schedules 10/11/96 Clean-up Set (CE-07) HP-602 Equipment Schedules 10/11/96 Clean-up Set (CE-07) HP-603 Equipment Schedules Lab Air Valves 10/11/96 Clean-up Set (CE-07) HP-604 Equipment Schedules Lab Air Valves 10/11/96 Clean-up Set (CE-07) HP-700 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-701 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-702 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-703 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-704 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-705 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-706 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-707 Control Diagrams 10/11/96 Clean-up Set (CE-07) HP-708 Temperature Control 10/11/96 Clean-up Set (CE-07) HP-708A Chiller Plant Manager 10/11/96 Clean-up Set (CE-07) P-210 Education Basement Plan Piping 10/11/96 Clean-up Set (CE-07) P-211 Education First Floor Piping 10/11/96 Clean-up Set (CE-07) P-212 Education Second Floor Piping 10/11/96 Clean-up Set (CE-07) P-213 Education Third Floor Piping 10/11/96 Clean-up Set (CE-07) P-214 Education Fourth Floor Piping 10/11/96 Clean-up Set (CE-07) ------------------------------------------------------------------------------------------------------- 22 ----------------------------------------------------------------------------------------------------- Number Title Revised Date Noted ----------------------------------------------------------------------------------------------------- P-215 Education Fifth Floor Piping 10/11/96 Clean-up Set (CE-07) P-220 Research Basement Piping 10/11/96 Clean-up Set (CE-07) P-221 Research First Floor-Heating Piping 10/11/96 Clean-up Set (CE-07) P-222 Research Second Floor-Heating Piping 10/11/96 Clean-up Set (CE-07) P-223 Research Third Floor-Heating Piping 10/11/96 Clean-up Set (CE-07) P-224 Research Fourth Floor-Heating Piping 10/11/96 Clean-up Set (CE-07) P-225 Research Fifth Floor-Plumbing & HVAC Piping 10/11/96 Clean-up Set (CE-07) P-226 Research/Education Interstitial Mech Equip Plan 10/11/96 Clean-up Set (CE-07) P-230 BME Basement 10/11/96 Clean-up Set (CE-07) P-231 BME First Floor 10/11/96 Clean-up Set (CE-07) P-232 BME Second Floor 10/11/96 Clean-up Set (CE-07) P-233 BME Third Floor 10/11/96 Clean-up Set (CE-07) P-234 BME Fourth Floor 10/11/96 Clean-up Set (CE-07) P-235 BME Fifth Floor 10/11/96 Clean-up Set (CE-07) P-236 BME Roof 10/11/96 Clean-up Set (CE-07) P-420 Research Basement Equipment Room 10/11/96 Clean-up Set (CE-07) P-420a Research Basement Equipment Room 10/11/96 Clean-up Set (CE-07) P-421a Research First Floor Piping 10/11/96 Clean-up Set (CE-07) P-421b Research First Floor Piping 10/11/96 Clean-up Set (CE-07) P-422a Research Second Floor Piping 10/11/96 Clean-up Set (CE-07) P-422b Research Second Floor Piping 10/11/96 Clean-up Set (CE-07) P-423a Research Third Floor Piping 10/11/96 Clean-up Set (CE-07) P-423b Research Third Floor Piping 10/11/96 Clean-up Set (CE-07) P-424a Research Fourth Floor Piping 10/11/96 Clean-up Set (CE-07) P-424b Research Fourth Floor Piping 10/11/96 Clean-up Set (CE-07) P-500 Plumbing Stacks 10/11/96 Clean-up Set (CE-07) P-501 Plumbing Stacks 10/11/96 Clean-up Set (CE-07) P-502 Plumbing Stacks 10/11/96 Clean-up Set (CE-07) P-503 Plumbing Stacks 10/11/96 Clean-up Set (CE-07) P-504 High Purity Water System Diagram 10/11/96 Clean-up Set (CE-07) P-505 Gas Service System Diagram 10/11/96 Clean-up Set (CE-07) P-506 Carbon Dioxide LN2 Piping Diagrams 10/11/96 Clean-up Set (CE-07) P-507 Fire Protection Riser Diagram 10/11/96 Clean-up Set (CE-07) P-508 Non-Potable Water System 10/11/96 Clean-up Set (CE-07) P-509 Lab Air & Vacuum System Diagrams 10/11/96 Clean-up Set (CE-07) P-510 Plumbing Stacks 10/11/96 Clean-up Set (CE-07) Structural S-210 Education Wing Foundation Plan 10/2/96 Clean-up Set (CE-07) S-210C Education Wing Caisson Plan 10/2/96 Clean-up Set (CE-07) S-211 Education Wing First Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-212 Education Wing Second Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-213 Education Wing Third Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-213 Education Wing Interstitial Plans and Details 10/9/96 Clean-up Set (CE-07) S-214 Education Wing Fourth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-215 Education Wing Fifth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-216 Education Wing Main Roof and P.H. Framing Plan 10/9/96 Clean-up Set (CE-07) S-217 Education Wing Penthouse Roof Framing Plan 10/9/96 Clean-up Set (CE-07) S-220 Research Wing Foundation Plan 10/2/96 Clean-up Set (CE-07) ----------------------------------------------------------------------------------------------------- 23 ----------------------------------------------------------------------------------------------- Number Title Revised Date Noted ----------------------------------------------------------------------------------------------- S-220C Research Wing Caisson Plan 10/2/96 Clean-up Set (CE-07) S-221 Research Wing First Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-222 Research Wing Second Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-223 Research Wing Third Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-223i Research Wing Third Floor Interstitial Plan 10/9/96 Clean-up Set (CE-07) S-224 Research Wing Fourth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-224i Research Wing Fourth Floor Interstitial Plan 10/9/96 Clean-up Set (CE-07) S-225 Research Wing Fifth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-225i Research Wing Fifth Floor Interstitial Plan 10/9/96 Clean-up Set (CE-07) S-226 Research Wing Main Roof and P.H. Framing Plan 10/9/96 Clean-up Set (CE-07) S-227 Research Wing Penthouse Roof Framing Plan 10/9/96 Clean-up Set (CE-07) S-240 Pedestrian Bridge Plans & Details 10/9/96 Clean-up Set (CE-07) S-310 Education Wing Sections and Details 10/9/96 Clean-up Set (CE-07) S-311 Education Wing Curtain Wall Framing 10/9/96 Clean-up Set (CE-07) S-320 Research Wing Sections and Details 10/9/96 Clean-up Set (CE-07) S-321 Research Wing Sections and Details 10/9/96 Clean-up Set (CE-07) S-322 Research Wing Interstitial Sections and Details 10/9/96 Clean-up Set (CE-07) S-323 Research Wing Sections and Details 10/9/96 Clean-up Set (CE-07) S-340 Pedestrian Bridge Sections & Details 10/9/96 Clean-up Set (CE-07) S-400 Research & Education Wings 10/9/96 Clean-up Set (CE-07) S-401 Research & Education Wings 10/9/96 Clean-up Set (CE-07) S-402 Research & Education Wings 10/9/96 Clean-up Set (CE-07) S-403 Research & Education Wings 10/9/96 Clean-up Set (CE-07) S-404 North Elevation - Existing NC Building 10/9/96 Clean-up Set (CE-07) S-410 Education Wing Column Schedule 10/9/96 Clean-up Set (CE-07) S-411 Education Wing Beam & Slab Schedules 10/9/96 Clean-up Set (CE-07) S-412 Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-413 Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-414 Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-415 Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-415a Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-416 Education Wing Post-Tensioned Beam Profiles 10/9/96 Clean-up Set (CE-07) S-420 Research Wing Column Schedule 10/9/96 Clean-up Set (CE-07) S-421 Research Wing Beam & Slab Schedules 10/9/96 Clean-up Set (CE-07) S-B230 BME/Basement Floor Plan 10/9/96 Clean-up Set (CE-07) S-B230C BME/Caisson Plan 10/9/96 Clean-up Set (CE-07) S-B231 BME/First Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B232 BME/Second Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B233 BME/Third Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B233i BME Interstitial Third Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B234 BME/Fourth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B234i BME Interstitial Fourth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B235 BME/Fifth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B235i BME Interstitial Fifth Floor Framing Plan 10/9/96 Clean-up Set (CE-07) S-B238 BME/Penthouse - Roof Framing Plan 10/9/96 Clean-up Set (CE-07) S-B241 Bridge over E. 96th St. 10/9/96 Clean-up Set (CE-07) S-B242 BME Bridge - BME/Education 10/9/96 Clean-up Set (CE-07) S-B330 BME Foundation Sections 10/9/96 Clean-up Set (CE-07) S-B331 BME Sections 10/9/96 Clean-up Set (CE-07) ----------------------------------------------------------------------------------------------- 24 -------------------------------------------------------------------------------------------------------------- Number Title Revised Date Noted -------------------------------------------------------------------------------------------------------------- S-B332 BME Steel Sections 10/9/96 Clean-up Set (CE-07) S-B333 BME Steel Sections 10/9/96 Clean-up Set (CE-07) S-B400 BME/Typical Details 10/9/96 Clean-up Set (CE-07) S-B401 BME/General Notes & Caisson Details 10/9/96 Clean-up Set (CE-07) S-B405 BME/Granite Panel Wall System Sections & Details 10/9/96 Clean-up Set (CE-07) S-B406 BME/Additional Typical Details 10/9/96 Clean-up Set (CE-07) S-B430 BME/Col. Schedule and Piers 10/9/96 Clean-up Set (CE-07) Specifications Architectural 0000 Project Specifications 6/17/96 GMP Bid Set 0001 Addendum No. 1 Specifications 7/24/96 Xxxxxxxx Xx. 0 0000 Xxxxxxxx No. 2 Specifications 8/2/96 Addendum No. 2 0004 Clean-up Set (CE-07) Specifications 10/14/96 Clean-up Set (CE-07) Xxxxxx Documents T-001 Xxxxxx Special Conditions 7/23/96 Addendum No. 1 T-002 Anticipated Project Schedule 7/22/96 Addendum No. 1 T-003 Bid Clarification Letter No. 1 8/21/96 Bid Clarification Letters T-004 Bid Clarification Letter No. 2 8/22/96 Bid Clarification Letters T-005 Bid Clarification Letter No. 3 8/23/96 Bid Clarification Letters T-006 Bid Clarification Letter No. 4 8/27/96 Bid Clarification Letters T-007 Bid Clarification Letter No. 5 8/27/96 Bid Clarification Letters T-008 Bid Clarification Letter No. 6 9/12/96 Bid Clarification Letters End Of Report -------------------------------------------------------------------------------------------------------------- 25 November 6, 1996- To: All Health Sciences Center Contractors Re: Cleveland Clinic Foundation Health Sciences Center Project Contract No. 6000H Letter of Understanding/Project Mission Statement Gentlemen: This Letter of Understanding shall serve as your commitment to adhere to the project management policies established by Xxxxxx Construction Company on the Cleveland Clinic Foundations "Health Sciences Center" project. 1) As a subcontractor on this project, you fully understand the construction schedule and phasing of the project as presented to you by Xxxxxx Construction. All costs associated with adhering to this schedule and phasing plans are incorporated into your contract sum. 2) During the course of the project, if any problem/conflict develops that may affect the project schedule or cost, you shall alert Xxxxxx Construction Company's Project Executive and Project Manager within forty-eight (48) hours of it's identity. 3) This Contractor agrees to submit his quotations for proposed changes in the work within ten (10) working days upon receipt of written documentation describing the proposed change. 4) This Contractor agrees that his office and field staff shall take directions from Xxxxxx Construction, not the Architect or any CCF personnel, as it relates to the scope of work included in your contract agreement with Xxxxxx on this project Xxxxxx Construction will coordinate all communications with The Cleveland Clinic's, Consultant/Owners Representative - Xx. Xxxx Xxxxxxxx. 5) This Contractor will advise Xxxxxx of any and all constructability issues immediately upon discovery and assist an expeditious resolution. 6) It is the Owner's desire to complete this project in advance of the completion date indicated on the bid schedule dated 7/22/96. In an attempt to satisfy the Owner's desires, Xxxxxx Construction will evaluate the progress of the work, and if deemed feasible in terms of sequencing, phasing, and manpower, will draft a revised schedule indicating an earlier completion date. This Contractor shall make every effort to schedule the receipt of his material/equipment so as not to preclude the project from being completed ahead of the current schedule. Xxxxxx will submit and review the revised schedule draft with the Contractor for his input and concurrence prior to committing to the Owner. In addition, this Contractor shall continually review the project schedule as the work progresses and identify early work concepts that will shorten the overall project schedule. These work concepts shall be reviewed with Xxxxxx in sufficient time to allow proper coordination with other trades affected. EXHIBIT 'C' 26 CLEVELAND CLINIC FOUNDATION HEALTH SCIENCES CENTER CONTRACT NO. 6000 PURCHASE REQUISITION NO. 3A GLAZED ALUMINUM CURTAIN WALL SYSTEM I SCOPE OF WORK 1. Bidders are to submit a lump sum proposal which shall include all material, all necessary labor forces, equipment, samples, design drawings, shop drawings, engineering, fabrication, surveying, supplies, plant, tools, scaffolding, transportation, cranes, rigging, hoisting, supervision, temporary construction of every nature, contributions, insurance, permits, and all other services, facilities, and other things necessary for the full performance of the work, as shown, and/or implied by the contract documents and clarified herein. 2. The bidder for this bid package shall include all work generally defined by the drawings or as necessary to result in a complete functioning system. The scope of work for this bid package is to include work as detailed in the following specification sections. (Note: Some specification sections may be divided between packages or may govern the work of more than one package.) Division 1 - All Sections Limited to roof exhaust stacks for work Section 05700 Ornamental Metal Work - of this package and trellis Section 07210 Building Insulation (for work of this package) Section 07410 Manufactured Wall Panels (for work of this package) Section 07901 Joint Sealers (for work of this package) Section 08800 Glass and Glazing (for work of this package) Section 08900 Exterior Wall General (for work of this package) Section 08920 Glazed Aluminum Curtain Wall Section 10200 Louvers and Vents (Exterior Only) (for work of this package) II. GENERAL ITEMS 1. The inter-relationship of all bid documents must be carefully examined by the bidders for the correlation of architectural, structural, mechanical, and electrical details. Absence of or inadequacy of detail in this regard must be brought to Xxxxxx'x attention in your proposal for resolution by the Architect/Engineer. 2. Bidders are required to visit the site and familiarize themselves with the existing site and actual field conditions, and advise Xxxxxx in your proposal of any exceptions taken with existing conditions. Any inconsistencies, omissions, out of tolerance dimensions relating to the work of others that affect the scope of your work, must be identified and submitted with your proposal. 3. Bidders are advised that specific scope items referenced in the documents as related to tunnel relocation and site demolition have been previously bid/awarded/performed by others. Copies of applicable scope documents pertaining to same are available for review at Xxxxxx'x on site field office. 1 EXHIBIT "D" (7 PAGES TOTAL) 27 II. GENERAL ITEMS (Continued...) 4. Xxxxxx Construction Company will secure the general building permit for the project. Trade Contractors are responsible to secure the required permits for their trade, including any necessary street opening and/or obstruction permits. 5. Contractors are responsible to implement their work and maintain progress in conformance with Xxxxxx'x job progress schedule. Contractors are responsible for all overtime, shift differential, and/or manpower necessary to maintain your portion of the job progress schedule. Should overtime/shift work be required because of contractors negligence and/or inability to maintain the pace of the project, this contractor will be charged for the added cost to provide temporary light, temporary power and temporary heat, if required. 6. Include comeback and out of sequence work which may be required due to temporary facilities, access for long lead mechanical/electrical items, and/or scheduling constraints. 7. Contractor shall furnish, install, and conduct his work as required to effect compliance with all existing codes, laws and ordinances, City, State, and Federal regulations, including OSHA and EPA requirements. 8. Xxxxxx Construction reserves the right to reject any employee on this project who does not conduct himself in a safe manner, or does not work in a manner which benefits the project as a whole. Rejected employees shall be removed from the job site at once without appeal. 9. Any shutdowns of existing lines or services to the hospital required for joining new work to old work must be done at the sole convenience of the hospital. This includes overtime work and/or temporary facilities as required. All such work is to be carefully and completely coordinated with Xxxxxx and the hospital. 10. Contractors are responsible to perform their own layout of work installed under their bid package. Basic site horizontal and vertical control will be provided by others to early phase contractors. 11. Bidders are advised to review the Xxxxxx Special Conditions regarding site access procedures, on site material storage, and project administration procedures, as well as provisions for temporary facilities including temporary light, temporary power, temporary heat, and temporary plumbing. 12. Contractors are responsible for their own continuous clean-up and final cleaning of your work as directed by Xxxxxx'x Project Superintendent and outlined in the Xxxxxx Special Conditions. 13. Include in your proposal a $10,000 allowance to be used as directed by Xxxxxx'x Project Superintendent upon written authorization. Unused allowance dollar at project completion will be reconciled via deduct change order. 14. In order to maintain project site communications, this Contractor shall provide portable radios to operate on the Xxxxxx frequency. Radios are available from Independence Communications for the purchase price of $952.00, including all programming, charger, etc. III. SPECIFIC CLARIFICATIONS The work is the complete design, furnishing, and installation of the Glazed Aluminum Curtain Wall System as specified in the Contract Documents and the following clarifications: 2 28 III. SPECIFIC CLARIFICATIONS (Continued...) 1. The selection of the Glazed Aluminum Curtain Wall System Trade Contractor is on the basis of Contractor's proven ability to DESIGN and CONSTRUCT an acceptable system consistent with the intent of the Contract Documents. 2. The work includes all necessary labor, material, scaffolding, equipment, tools, hoisting, rigging, transportation, storage, and any other item or facility required or reasonably inferred to provide a complete glazed aluminum curtain wall system. 3. The work consists of, but is not limited to: A. Glass and Glazing, Windows B. Aluminum Framing, gaskets, seals, etc. (*)C. Storefront and entrances - HARDWARE PER HARDWARE SCHEDULE BY OTHERS D. Flashing (ANY PLACE ATTACHED TO CURTAINWALL SYSTEM COMPONENTS) E. Parapets including all copings (COPING AT CURTAINWALL AREAS ONLY. PARAPET BACK PANEL BY OTHERS) F. Waterproofing of system as necessary G. Structural anchors H. Anchorage for glazed aluminum curtain wall systems I. Onsite QA/QC Mock-up (AS A PART OF PERMANENT INSTALLATION ONLY) J. Laboratory mock-up including fees of testing laboratory and travel expenses of Owner, Architect, and Construction Manager (PER BID CLARIFICATION LETTER #3 DATED 8/23/96) K. Insulation L. Firesafing M. Caulking (EVERY PLACE WHERE IT TOUCHES CURTAINWALL SYSTEM COMPONENTS) N. Clean-up O. Louvers and vents occurring in exterior wall (at all areas) P. Roofing interface Q. Trellis R. Roof exhaust stacks (ref. drawing A-1193) S. Include curtainwall for pedestrian bridge, including belly pans and interior metal wall panels (standing seam roof is by others) X. XXXXX "A" AS MODIFIED DATED 10/9/96 4. The Glazed Aluminum Curtain Wall System Trade Contractor shall provide all structural components required for the support and installation of the glazed aluminum curtain wall. The Glazed Aluminum Curtain Wall System Trade Contractor shall design any additional slab reinforcement for anchors and coordinate design information so that this work is coordinated with the structural frame packages. The Glazed Aluminum Curtain Wall System Trade Contractor will furnish and install all structural steel framing required for the glazed aluminum curtain wall system, such as kickers. 5. All embed plate anchors or angles shall be sized to accommodate an Installation tolerance of plus or minus three inches in any direction. (CLARIFIED AS PLACEMENT TOLERANCE OF 1-1/2" IN ANY DIRECTION.) 6. The Glazed Aluminum Curtain Wall System Trade Contractor is responsible for all testing as described within the specifications, AS CLARIFIED HEREIN. (*) 3.C ABOVE IS FURTHER CLARIFIED THAT HARDWARE AND/OR HARDWARE TEMPLATES TO BE FURNISHED TO SUBCONTRACTOR PRIOR TO DOOR MANUFACTURING. SUBCONTRACTOR TO ADVISE AS TO REQUIRED TIME FRAME. 3 29 III. Specific Clarifications (Continued...) 7. The Glazed Aluminum Curtain Wall System Trade Contractor is to include all costs for the laboratory mock-up. This covers labor and materials to erect the Glazed Aluminum Curtain Wall System portion of the mock-up at either of the testing laboratories referenced in the specifications, as well as all laboratory fees for the mock-up in its entirety, i.e. including stone truss and/or precast components which will be delivered/installed by others. The Glazed Aluminum Curtain Wall System Trade Contractor will be the primary coordinator for the mock-up testing. Also, include an allowance of $25,000 to cover traveling expenses for the Architects, Owner, and Construction Manager. (Note: This is in addition to the onsite mock-up included under section 08920, item 1.2.H.) 8. The Glazed Aluminum Curtain Wall System Trade Contractor will coordinate the design, mock-up, fabrication, and installation of the glazed aluminum curtain wall with the other prime contractors and will sequence his work accordingly. 9. Site Conditions: A. A dual cage, 5,000 pound capacity, personnel and material hoist, to be located along the south side of the building, will be available on an as scheduled basis in accordance with Xxxxxx'x Special Conditions. B. The Glazed Aluminum Curtain Wall Trade Contractor shall provide his own means of rigging and hoisting such as a mobile tower crane or similar crane. C. Cleaning up of all debris, such as crating materials, rubble, scrap aluminum, is the responsibility of the Glazed Aluminum Curtain Wall Trade Contractor. The Glazed Aluminum Curtain Wall Trade Contractor shall remove debris from each floor and dispose of in accordance with Xxxxxx'x Special Conditions. D. The structural steel and concrete frame Contractors will provide the perimeter safety cable/barricade system and will maintain the same until the start of the Glazed Aluminum Curtain Wall System. At that time, the Glazed Aluminum Curtain Wall System Trade Contractor will remove that portion of the perimeter safety cable/barricade system needed to install the Curtain Wall System. The Curtain Wall System Trade Contractor will reinstall that portion of the removed safety cable/barricade system as necessary and place any unnecessary safety cable in one area of the floor for removal and disposition by others. E. On site storing of Glazed Aluminum Curtain Wall System materials is limited. Storing/stocking of materials to be coordinated with the Project Superintendent. F. All deliveries must be coordinated with Construction Manager. G. Major deliveries to the site can only occur during the weekday non-rush hours which are from 9:00 a.m. to 4:00 p.m. and from 7:00 p.m. to 6:00 a.m. During rush hours, 6:00 a.m. to 9:00 a.m. and 4:00 p.m. to 7:00 p.m., Contractors can not make deliveries to the site. Weekend deliveries are allowed, however, all premium costs for guards, traffic control, electric, electricians, hoists and operators, etc., shall be at the Glazed Aluminum Curtain Wall System Trade Contractor's expense. H. Glazed Aluminum Curtain Wall System Trade Contractor shall provide his own line and grade controls based on control lines and bench marks provided by others in accordance with Xxxxxx'x Special Conditions. 30 ** Confidential treatment requested pursuant to Rule 406 III. Specific Clarifications (Continued...) 1. Temporary power will be provided by the Electrical Trade Contractor in accordance with Xxxxxx'x Special Conditions. Any additional power requirements or the cost to hook up special equipment, such as welders, will be by the Glazed Aluminum Curtain Wall System Trade Contractor. 10. Glazed Aluminum Curtain Wall System Trade Contractor shall wipe clean the components of the system during installation and shall include a final cleaning of the exterior side upon completion of the system. 11. (DELETED) 12. Contractors must submit with their proposal a set of drawings as per section 08900. The contractor must also submit a list of deviations from the base design including any vendor or fabricator substitutions. 13. Base Bid is to include a ** warranty. This includes all components, including sealants. Warranty to run directly to the Owner. 14. Contractor is to include in his proposal a detail schedule for the mockup, engineering, fabrication, erection, etc. that is consistent with the project schedule. (See Exhibit "A" attached hereto.) 15. Basis of proposal is to allow for an edge of slab tolerance that may vary plus or minus 1.5 inches in any direction, an overall adjustment of three inches up or down or in and out. 16. Contractor to provide layout drawings for embedded anchors, plates, etc. so as to maintain project schedule for concrete, structural steel, pt concrete, etc. Embeds are to be furnished by Glazed Aluminum Curtain Wall System Contractor and installed by Concrete Contractor, Bid Package #4. 17. Work does not include interior glass and glazing. --- 18. Design of expansion joints which attaches to the Work of this Trade Contractor (*) 19. Contractor may propose voluntary design alternates for consideration and review. 20. Contractor must submit a site staging plan with his proposal showing proposed stocking areas, crane locations and movements, and means of relocating crane around the site. 21. (Per item 9, Additional Provisions, page 3B) 22. Include one onsite test for air and water infiltration using a job built test chamber, to be performed at direction of Xxxxxx'x Project Superintendent. 23. Include all required winter weather protection necessary to complete this scope of work in accordance with Xxxxxx'x Project Schedule. 24. This Contractor shall identify all subcontractors and the scope of work each will provide as part of his bid. (*) and includes furnishing and installing complete unit vertically and horizontally as may be required. 5 31 ** Confidential treatment requested pursuant to Rule 406 III. Specific Clarifications (Continued...) 25. The Glazed Aluminum Curtain Wall System Trade Contractor shall include furnishing and installing all building insulation/firesafing occurring integral with the glazed aluminum curtain wall system. (Building insulation behind precast and stone truss will be by others.) 26. The Glazed Aluminum Curtain Wall System Trade Contractor shall include furnishing and installing of joint sealants required for the installation of work under this bid package only. (Caulking at precast and stone areas is not work of this bid package.) 27. The Glazed Aluminum Curtain Wall System Trade Contractor shall include furnishing and installing of all louvers and vents occurring in exterior wall areas (whether in glazed curtain wall, stone, and/or precast areas.) 29. The Glazed Aluminum Curtain Wall System Trade Contractor shall include furnishing and installing of architectural feature roof exhaust stacks (ref. drawing A-1193). 30. The Glazed Aluminum Curtain Wall System Trade Contractor shall include all work associated with the exterior Level 5 trellis systems at the Education and BME buildings. Additionally, this work shall be priced as a deduct alternate. 31. Standing seam roof panels occurring on the long pedestrian bridge are not a part of this bid package. IV. Comments Per Scope Review Meetings 1. Contractor has agreed to project engineering, mock-up, fabrication and erection in accordance with the attached Exhibit "B" schedule. Schedule performance is predicated on RFI, submittal and approval process parameters as indicated on same. 2. Scope includes segmented glass and mullions with curved tube at the BME and Education building (with the exception of segmented elements at Education stair per accepted VE items noted below). 3. Scope includes segmented glass with curved tubes and panels at the Research drum area. 4. Scope includes segmented glass and mullions with curved tubes at the Education building library stair area. 5. Scope includes STC ratings for exterior wall (specification 08920) based on the specified glass. V. Accepted VE Items The following value engineering items (not shown on the current documents) have been incorporated into the base project award with the following values: 1. Utilize 3 coat in lieu of 4 coat exterior paint system ** 2. Utilize polycron paint at interior ** 3. Utilize aluminum in lieu of stainless steel doors ** V. Accepted VE Items (Continued...) 32 ** Confidential treatment requested pursuant to Rule 406 4. Eliminate molded corner at interior glazing gaskets ( ** ) 5. Utilize segmented elements in lieu of curved at Education building stair headpiece ( ** ) VI. Alternates - valid for 30 days beyond contract execution -------------------------------------------------------- 1. Add BME/Carnegie Bridge ** 33 Cleveland Clinic Health Sciences Center FCAM Quote # 9640 10/9/96 RIDER "A" Our preceding outline and pricing is based on the following items: EXCLUSIONS ---------- 1. Protection of our materials during proper storage or during or after installation. 2. Removal or replacement of aluminum, glass, or other materials broken or damaged by others. 3. Rubbish removal from site. We will place our rubbish in provided dusters located on the ground floor at reasonable intervals. 4. Subcontractor will be responsible for glass replacement labor & material relating to 5 year warranty. After 5 year warranty is up, manufacturer material warranty will be in effect. (See item 22 of this Rider for further clarification) 5. Interior glass or aluminum work of any type. 6. Stone or stone support system. 7. Patching of fireproofing after attachment of curtainwall clips. Removal of fireproofing will be held to a minimum. Unless removal of spray fireproofing is excessive and uncontrolled. 8. Cost of furnishing bonds. 9. Layout, inspection and installation of embeds. Embeds and layout drawings will be provided FOB jobsite for installation by the General Contractor or his designated subcontractor, at no cost to FCAM. 10. Removal or disposal of OSHA cables from the floors or project site. This is per item 9D of Purchase Requisition on page 4. 11. Providing, maintaining and removal of safety nets/overhead protection where required. See item 10 above - also unless required for Subcontractor's work and workforce. 34 Cleveland Clinic HCAM estimate #9640 10/9/96 Rider "A" continued........... 13. Expansion Joints at areas other than: Bridge." Per item 18, page 5 of Purchase Requisition. 14. Liquidated damage assessments of any type. 15. Permits and fees. Building permit not Subcontractor's responsibility. Any other specific permits required of Subcontractor to implement his work are Subcontractor's responsibility. 16. Field measurements or examination of structure. 17. Out of sequence work other than hoist bay areas. Per item 9, page 3B of Additional Provisions. 18. Work on overtime hours. Unless required due to Subcontractor's inability to maintain agreed upon schedule. 20. Blankoffs for Louvers within our system. 21. We will make a concerted effort to meet the MBE/WBE targeted goals. This issue has not been addressed at this time. 22. Glass warranty relates to - deterioration due to normal conditions of use, incorrect installation, defective glass design, coating, etc. and as further defined under "Definition" Article of Specification Section 08800 "Glazing". 35 ** Confidential treatment requested pursuant to Rule 406 Cleveland Clinic Health Sciences Center FCAM Quote #9640 10/9/96 ASSUMPTIONS AND CLARIFICATIONS ------------------------------ 2. We require the use of sufficient perimeter floor space for the storage, assembly, and installation of our materials. 3. Xxxxxx Construction is to provide adequate temporary 110 volt power, toilets and water at reasonable locations at no cost to FCAM. This item per Xxxxxx'x Special Conditions. 4. Location for all cutouts for hose bibs, standpipes, fixtures, railings, etc. shall be determined prior to fabrication of our work. 5. We require access to the perimeter of the building for unloading/installation of fabricated materials. TERMS ----- 1. Our price is predicated on net payment for dedicated materials (extrusions, glass, etc.) and fabricated materials and engineering costs, upon presentation of invoices and insurance certificates. This item only to extent indicated in Xxxxxx'x Special Conditions and does not relate to Cuyahoga County only. 2. Our price is based on ** retention for the first ** of the value of the work, and ** thereafter. Per Xxxxxx'x Special Conditions. We require that all mutually applicable information contained within this Rider "A" be incorporated into the final agreement. 36 Inspection and Defective Work ARTICLE X. The Subcontractor shall at all times provide sufficient, safe and proper facilities for the inspection of the Work by Xxxxxx, the Architect and their authorized representatives in the field, at shops or at any other place where materials or equipment for the Work are in the course of preparation, manufacture, treatment or storage. The Subcontractor shall, within twenty-four (24) hours after receiving written notice from Xxxxxx to that effect, proceed to take down all portions of the Work and remove from the premises any materials whether worked or unworked, which the Architect or Xxxxxx shall condemn as unsound, defective or improper or as in any way failing to conform to this Agreement or the Plans, Specifications or other Contract Documents, and the Subcontractor, at its own cost and expense, shall replace the same with proper and satisfactory work and materials and make good all work damaged or destroyed by or as a result of such unsound, defective, improper or nonconforming work or materials or by the taking down, removal or replacement thereof. Failure to Prosecute, etc. ARTICLE XI. Should the Subcontractor at any time refuse or neglect to supply a sufficiency of skilled workers or materials of the proper quality and quantity, or fail in any respect to prosecute the Work with promptness and diligence, or cause by any act of omission the stoppage, impede, obstruct, hinder or delay of or interference with or damage to the work of Xxxxxx or of any other contractors or subcontractors on the Project, or fail in the performance of any of the terms and provisions of this Agreement or of the other Contract Documents, or should the Architect determine that the Work or any portion thereof is not being performed in accordance with the Contract Documents, or should there be filed by or against the Subcontractor a petition in bankruptcy or for an arrangement of reorganization, or should the Subcontractor become insolvent or be adjudicated a bankrupt or go into liquidation or dissolution, either voluntarily or involuntarily or under a court order, or make a general assignment for the benefit of creditors, or otherwise acknowledge insolvency, then in any of such events, each of which shall constitute a default hereunder on the Subcontractor's part, Xxxxxx shall have the right, in addition to any other rights and remedies provided by this Agreement and the other Contract Documents or by law, after three (3) days written notice to the Subcontractor mailed or delivered to the last known address of the latter, (a) to perform and furnish through itself or through others any such labor or materials for the Work and to deduct the cost thereof from any monies due or to become due to the Subcontractor under this Agreement, and/or (b) to terminate the employment of the Subcontractor for all or any portion of the Work, enter upon the premises and take possession, for the purpose of completing the Work, of all materials, equipment, scaffolds, tools, appliances and other items thereon, all of which the Subcontractor hereby transfers, assigns and sets over to Xxxxxx for such purpose, and to employ any person or persons to complete the Work and provide all the labor, services, materials, equipment, and other items required therefor. In case of such termination of the employment of the Subcontractor, the Subcontractor shall not be entitled to receive any further payment under this Agreement until the Work shall be wholly completed to the satisfaction of Xxxxxx and the Architect and shall have been accepted by them, at which time, if the unpaid balance of the amount to be paid under this Agreement shall exceed the cost and expense incurred by Xxxxxx in completing the Work, such excess shall be paid by Xxxxxx to the Subcontractor, but if such cost and expense shall exceed such unpaid balance, then the Subcontractor shall pay the difference to Xxxxxx. Such cost and expense shall include, not only the cost of completing the Work to the satisfaction of Xxxxxx and the Architect and of performing and furnishing all labor, services, materials, equipment, and other items required therefor, but also all losses, damages, costs and expenses, including legal fees and disbursements sustained, incurred or suffered by reason of or resulting from the Subcontractor's default. Loss or Damage to Work ARTICLE XII. Xxxxxx shall not be responsible for any loss or damage to the Work to be performed and furnished under this Agreement, however caused, until after final acceptance thereof by Xxxxxx and the Architect, nor shall Xxxxxx be responsible for loss of or damage to materials, tools, equipment, appliances or other personal property owned, rented or used by the Subcontractor or anyone employed by it in the performance of the Work, however caused. Fire Insurance Xxxxxx or Owner shall effect and maintain fire insurance (with extended coverage, if specified or otherwise required) upon all Work, materials and equipment incorporated in the Project and all materials and equipment on or about the Premises intended for permanent use or incorporation in the Project or incident to the construction thereof, the capital value of which is included in the cost of the Work, but not including any contractors' machinery, tools, equipment, appliances or other personal property owned, rented or used by the Subcontractor or anyone employed by it in the performance of the Work. The total value of the property described above as insurable under this Article and as shown on the approved monthly requisition provided for in Article IV, plus the total value of similar property incorporated in the Project or delivered on the Premises during the month but not included in said requisition, as reported by the Subcontractor to Xxxxxx for insurance purposes only, shall determine the total value of the Subcontractor's work, materials and equipment to be insured under this Article. The maximum liability to the Subcontractor under this insurance shall be for not more than that proportion of any loss which the last reported value of the insured property bore to the actual value of said property at the time of such last report, and in no event for more than the actual loss. In the event of a loss insured under this Article, the Subcontractor shall be bound by any adjustment which shall be made between Xxxxxx or the Owner and the insurance company or companies. Loss, if any, shall be made payable to Xxxxxx and/or the Owner as their interests may appear, for the account of whom it may concern. Cleaning Up ARTICLE XIII. The Subcontractor shall, at its own cost and expense, (1) keep the Premises free at all times from all waste materials, packaging materials and other rubbish accumulated in connection with the execution of its Work by collecting and depositing said materials and rubbish in locations or containers as designated by Xxxxxx from which it shall be removed by Xxxxxx from the Premises without charge, (2) clean and remove from its Work and from all contiguous work of others any soiling, staining, mortar, plaster, concrete or dirt caused by the execution of its Work and make good all defects resulting therefrom (3) at the completion of its Work in each area, perform such cleaning as may be required to leave the area "broom clean", and (4) at the entire completion of its Work remove all of its tools, equipment, scaffolds, shanties and surplus materials. Should the Subcontractor fail to perform any of the foregoing to Xxxxxx'x satisfaction, Xxxxxx shall have the right to perform and complete such work itself or through others and charge the cost thereof to the Subcontractor. Compliance with Law and Permits ARTICLE XIV. The Subcontractor shall obtain and pay for all necessary permits and licenses pertaining to the Work and shall comply with all Federal, State, Municipal and local laws, ordinances, codes, rules, regulations, standards, orders, notices and requirements, including but not limited to those relating to safety, discrimination in employment, fair employment practices or equal employment opportunity, and with the requirements of the American Insurance Association, whether or not provided for by the Plans, Specifications, General Conditions, or other Contract Documents, without additional charge or expense to Xxxxxx, and shall also be responsible for and correct, at its own cost and expense, any violations thereof resulting from or in connection with the performance of its Work. 4 37 The Subcontractor shall at any time upon demand furnish such proof as Xxxxxx may require showing such compliance and the correction of such violations. The Subcontractor agrees to save harmless and indemnify Xxxxxx from and against any and all loss, injury, claims, actions, proceedings, liability, damages, fines, penalties, costs and expenses, including legal fees and disbursements, caused or occasioned directly or indirectly by the Subcontractor's failure to comply with any of said laws, ordinances, rules, regulations, standards, orders, notices or requirements or to correct such violations. Labor to be Employed ARTICLE XV. The Subcontractor shall not employ men, means, materials or equipment which may cause strikes, work stoppages or any disturbances by workers employed by the Subcontractor, Xxxxxx or other contractors or subcontractors on or in connection with the Work or the Project or the location thereof. The Subcontractor agrees that all disputes as to jurisdiction of trades shall be adjusted in accordance with any plan for the settlement of jurisdictional disputes which may be in effect either nationally or in the locality in which the Work is being done and that it shall be bound and abide by all such adjustments and settlements of jurisdictional disputes, provided that the provisions of this Article shall not be in violation of or in conflict with any provisions of law applicable to the settlement of such disputes. Should the Subcontractor fail to carry out or comply with any of the foregoing provisions, Xxxxxx shall have the right, in addition to any other rights and remedies provided by this Agreement or the other Contract Document or by law, after three (3) days written notice mailed or delivered to the last known address of the Subcontractor, to terminate this Agrement or any part thereof or the employment of the Subcontractor for all or any portion of the Work, and, for the purpose of completing the Work, to enter upon the Premises and take possession, in the same manner, to the same extent and upon the same terms and conditions as set forth in Article XI of this Agreement. Taxes and Contributions ARTICLE XVI. The Subcontractor for the Price herein provided for, hereby accepts and assumes exclusive liability for and shall indemnify, protect and save harmless Xxxxxx and the Owner from and against the payment of: 1. All contributions, taxes or premiums (including interest, and penalties thereon) which may be payable under the Unemployment Insurance Law of any State, Federal Social Security Act, Federal, State, County and/or Municipal Tax Withholding Laws, or any other law, measured upon the payroll of or required to be withheld from employees, by whomsoever employed, engaged in the Work to be performed and furnished under this Agreement. 2. All sales, use, personal property and other taxes (including interest and penalties thereon) required by any Federal, State, County, Municipal or other law to be paid or collected by the Subcontractor or any of its subcontractors or vendors or any other person or persons acting for, through or under it or any of them, by reason of the performance of the Work or the acquisition, ownership, furnishing or use of any materials, equipment, supplies, labor, services or other items for or in connection with the Work. 3. All pension, welfare, vacation, annuity and other union benefit contributions payable under or in connection with labor agreements with respect to all persons, by whomsoever employed, engaged in the Work to be performed and furnished under this Agreement. Patents ARTICLE XVII. The subcontractor hereby agrees to indemnify, protect and save harmless Xxxxxx and the Owner from and against any and all liability, loss or damage and to reimburse Xxxxxx and the Owner for any expenses, including legal fees and disbursements, to which Xxxxxx and the Owner may be put because of claims or litigation on account of infringement or alleged infringement of any letters patent or patent rights by reason of the Work or materials, equipment or other items used by the Subcontractor in its performance. Mechanics' Liens or Claims ARTICLE XVIII. The Subcontractor for its subcontractors, laborers and materialmen and suppliers and all others directly or indirectly acting for, through or under it or any of them covenants and agrees that no liens or claims, whether a mechanics' lien or an affected account or otherwise, will be filed or maintained against the Project or Premises or any part thereof or any interests therein or any improvements thereon, or against any monies due or to become due from the Owner to Xxxxxx or from Xxxxxx to the Subcontractor, for or on account of any work, labor, services, materials, supplies, equipment, or other items performed or furnished for or in connection with the Work, and the Subcontractor for its Subcontractors, laborers, and materialmen and suppliers and all others above mentioned does hereby expressly waive, release and relinquish all rights to file or maintain such liens and claims and agrees further that this waiver of the right to file or maintain such liens and claims shall be an independent covenant and shall apply as well to work, labor and services performed and materials, supplies, equipment and other items furnished under any change order or supplemental agreement for extra or additional work in connection with the Project as to the Original Work covered by this Agreement. If any subcontractor, laborer, materialman or supplier of the Subcontractor or any other person directly or indirectly acting for, through or under it or any of them files or maintains a lien or claim, whether a mechanics' lien or an affected account or otherwise, a mechanic's lien or claim against the Project or Premises or any part thereof or any interests therein or any improvements thereon or against any monies due or to become due from the Owner to Xxxxxx or from Xxxxxx to the Subcontractor, for or on account of any work, labor, services, materials, supplies, equipment or other items performed or furnished for or in connection with the Work or under any change order or supplemental agreement for extra or additional work in connection with the Project, the Subcontractor agrees to cause such liens and claims to be satisfied, removed or discharged at its own expense by bond, payment or otherwise within ten (10) days from the date of the filing thereof, and upon its failure so to do Xxxxxx shall have the right, in addition to all other rights and remedies provided under this Agreement and the other Contract Documents or by law, to cause such liens or claims to be satisfied, removed or discharged by whatever means Xxxxxx chooses, at the entire cost and expense of the Subcontractor (such cost and expense to include legal fees and disbursements). The Subcontractor agrees to indemnify, protect and save harmless Xxxxxx and the Owner from and against any and all such liens and claims and actions brought or judgments rendered thereon, and from and against any and all loss, damages, liability, costs and expenses, including legal fees and disbursements, which Xxxxxx and/or the Owner may sustain or incur in connection therewith. Assignment and Subletting ARTICLE XIX. Neither this Agreement nor any monies due or to become due hereunder shall be assignable without the prior written consent of Xxxxxx nor shall the whole or any part of this Agreement be sublet without like prior written consent. Any such assignment or subletting without such prior written consent shall be void and of no effect and shall vent no right or right of action in the assignee or subcontractor against Xxxxxx. Xxxxxx'x consent to any assignment or subletting shall not relieve the Subcontractor 5 38 ** Confidential treatment requested pursuant to Rule 406 of any of its agreements, duties, responsibilities or obligations under this Agreement and the other Contract Documents, and the Subcontractor shall be and remain as fully responsible and liable for the defaults, neglects, acts and omissions of its assignees and subcontractors and all persons directly or indirectly employed by them as it is for its own defaults, neglects, acts and omissions and those of its own officers, agents, servants and employees. The Subcontractor shall bind each of its subcontractors to all of the terms, provisions and covenants of this Agreement and the other Contract Documents with respect to the sublet Work. Xxxxxx'x consent to any subletting shall not be deemed to create any contractual relationship between Xxxxxx and any subcontractor to whom the Work or any portion thereof is sublet, and shall not vest any right or right of action in such subcontractor against Xxxxxx. ARTICLE XX. Xxxxxx shall have the right at any time by written notice to the Subcontractor, to terminate this Agreement Termination and require the Subcontractor to cease work hereunder, in which of Agreement case, provide the Subcontractor be not then in default, Xxxxxx shall indemnify the Subcontractor against any damage directly resulting from such termination, except that the Subcontractor shall not be entitled to anticipated profits on work unperformed or on materials or equipment unfurnished. ARTICLE XXI. The Subcontractor hereby guarantees the Work to Guarantees the full extent provided in the Plans, Specifications, General Conditions, Special Conditions and other Contract Documents. The Subcontractor shall remove, replace and/or repair at its own expense and at the convenience of the Owner any faulty, defective or improper work, materials or equipment discovered within ** from the date of the acceptance of the Project as a whole by the Architect and the Owner or for such longer period as may be provided in the Plans, Specifications, General Conditions, Special Conditions or other Contract Documents. Without limitation by the foregoing, the Subcontractor shall pay in addition for all damage to the Project resulting from defects in the Work and all costs and expenses necessary to correct, remove, replace and/or repair the Work and any other work or property which may be damaged in the correcting, removing, replacing or repairing the Work. Accident ARTICLE XXII. The Subcontractor agrees that the prevention Prevention of accidents to workmen engaged upon or in the vicinity of the Work is its responsibility. The Subcontractor agrees to comply with all Federal, State, Municipal and local laws, ordinances, rules, regulations, codes, standards, orders, notices and requirements concerning safety as shall be applicable to the Work, including, among others, the Federal Occupational Safety and Health Act of 1970, as amended, and all standards, rules, regulations and orders which have been or shall be adopted or issued thereunder, and with the safety standards established during the progress of the Work by Xxxxxx. When so ordered, the Subcontractor shall stop any part of the Work which Xxxxxx deems unsafe until corrective measures satisfactory to Xxxxxx have been taken, and the Subcontractor agrees that it shall not have nor make any claim for damages growing out of such stoppages. Should the Subcontractor neglect to take such corrective measures, Xxxxxx may do so at the cost and expense of the Subcontractor and may deduct the cost thereof from any payments due or to become due to the Subcontractor. Failure on the part of Xxxxxx to stop unsafe practices shall in no way relieve the Subcontractor of its responsibility therefor. This Subcontractor acknowledges the receipt of The Xxxxxx Corporation's policies on "Safety" and "Drug and Alcohol Abuse". Subject to applicable law this Subcontractor further agrees to be bound to these policies as a part of the supplemental and special conditions to the contract for construction of the project. Liability ARTICLE XXIII. The Subcontractor hereby assumes entire for Damage responsibility and liability for any and all damage or injury of and Personal any kind or nature whatever (including death resulting therefrom) Injury to all persons, whether employees of any tier of the Subcontractor or otherwise, and to all property caused by, resulting from, arising out of or occurring in connection with the execution of the Work, or in preparation for the Work, or any extension, modification, or amendment to the Work by change order or otherwise. Except to the extent, if any, expressly prohibited by statute and excluding from this indemnity such acts or omissions, if any, of the party indemnified for which it is not legally entitled to be indemnified by the Subcontractor under applicable law, should any claims for such damage or injury (including death resulting therefrom) be made or asserted, whether or not such claims are based upon Xxxxxx'x or the Owner's alleged active or passive negligence or participation in the wrong or upon any alleged breach of any statutory duty or obligation on the part of Xxxxxx or the Owner, the Subcontractor agrees to indemnify and save harmless Xxxxxx and the Owner, their officers, agents, servants and employees from and against any and all such claims and further from and against any and all loss, cost, expense, liability, damage or injury, including legal fees and disbursements, that Xxxxxx and the Owner, their officers, agents, servants or employees may directly or indirectly sustain, suffer or incur as a result thereof and the Subcontractor agrees to and does hereby assume, on behalf of Xxxxxx and the Owner, their officers, agents, servants and employees, the defense of any action at law or in equity which may be brought against Xxxxxx and/or the Owner, their officers, agents, servants or employees upon or by reason of such claims and to pay on behalf of Xxxxxx and the Owner, their officers, agents, servants and employees, upon demand, the amount of any judgment that may be entered against Xxxxxx and/or the Owner, their officers, agents, servants or employees in any such action. In the event that any such claims, loss, cost, expenses, liability, damage or injury arise or are made, asserted or threatened against Xxxxxx and/or the Owner, their officers, agents, servants or employees, Xxxxxx shall have the right to withhold from any payments due or to become due to the Subcontractor an amount sufficient in its judgment to protect and indemnify Xxxxxx and the Owner, their officers, agents, servants and employees from and against any and all such claims, loss, cost, expense, liability, damage or injury, including legal fees and disbursements, or Xxxxxx, in its discretion may require the Subcontractor to Furnish a surety bond satisfactory to Xxxxxx guaranteeing such protection, which bond shall be furnished by the Subcontractor within five (5) days after written demand has been made therefor. In furtherance to but not in limitation of the indemnity provisions in this Agreement, Subcontractor hereby expressly and specifically waives any statutory or constitutional immunity it enjoys from suits by its own employees or from limitations of liability or recovery under workers compensation laws. Compensation Before commencing the Work, the Subcontractor shall procure and Liability and maintain, at its own expense, until completion and final Insurance acceptance of the Work at least the following insurance from insurance companies satisfactory to Xxxxxx. 1. WORKERS' COMPENSATION AND EMPLOYERS' LIABILITY INSURANCE in accordance with laws of the State in which the Work is situated. 6 39 ** Confidential treatment requested pursuant to Rule 406 2. COMPREHENSIVE GENERAL LIABILITY INSURANCE INCLUDING COMPLETED OPERATIONS, CONTRACTUAL LIABILITY INSURANCE AGAINST THE LIABILITY ASSUMED HEREINABOVE, and including CONTRACTORS' PROTECTIVE LIABILITY INSURANCE if the Subcontractor sublets to another all or any portion of the Work, with the following minimum limits: Combined Single Limit ** 3. COMPREHENSIVE AUTOMOBILE LIABILITY INSURANCE covering all owned, non-owned and hired automobiles used in connection with the Work, with the following minimum limits: Bodily Injury (including death) ** per accident and Property Damage Before commencing the Work, the Subcontractor shall furnish a certificate, satisfactory to Xxxxxx, from each insurance company showing that the above insurance is in force, stating policy numbers, dates of expiration, and limits of liability thereunder, and further providing that the insurance will not be canceled or changed until the expiration of at least thirty (30) days after written notice of such cancellation or change has been mailed to and received by Xxxxxx. Xxxxxx shall be named as an additional insured under these policies of insurance. If the Subcontractor fails to procure and maintain such insurance, Xxxxxx shall have the right, but not the obligation, to procure and maintain the said insurance for and in the name of the Subcontractor and the Subcontractor shall pay the cost thereof and shall furnish all necessary information to make effective and maintain such insurance. BONDS ----- Article XXIV. The Subcontractor shall furnish to Xxxxxx a performance bond in the amount of ** and a separate payment bond in the amount of ** , the form and contents of such bonds and the Surety or Sureties thereon to be satisfactory to Xxxxxx. SEVERABILITY ------------ ARTICLE XXV. In the event that any provision or any part of a provision of this Agreement shall be finally determined to be superseded, invalid, illegal or otherwise unenforceable pursuant to applicable laws by an authority having jurisdiction, such determination shall not impair or otherwise affect the validity, legality, or enforceability of the remaining provisions or parts of provisions of this Agreement, which shall remain in full force and effect as if the unenforceable provision or part were deleted. ENTIRE AGREEMENT --------- ARTICLE XXVI. This Agreement constitutes the entire agreement between the parties hereto. No oral representations or other agreements have been made by Xxxxxx except as stated in the Agreement. This Agreement may not be changed in any way except as herein provided, and no term or provision hereof may be waived by Xxxxxx except in writing signed by its duly authorized officer or agent. The marginal descriptions of any term or provision of this Agreement are for convenience only and shall not be deemed to limit, restrict or alter the content, meaning or effect thereof. The said parties, for themselves, their heirs, executors, administrators, successor and assigns, do hereby agree to the full performance of all of the terms and provisions herein contained. IN WITNESS WHEREOF the parties to those presents have hereunto set their hands as of the day and year first above written. XXXXXX CONSTRUCTION COMPANY In the Presence of: (Witness) X /s/ "illegible" By:/s/ X.X. XXXXXXXXX --------------------------- ------------------------------ X.X. Xxxxxxxxx Vice President In the Presence of: (Witness) FLOUR CITY ARCHITECTURAL METALS, ---------------------------- INC. Subcontractor X /s/ XXXX X. XXXXXXXXX By:/s/ "illegible" President --------------------------- ------------------------------ Official Title Subcontractor's OHIO State Unemployment Ins. No. ---------------- --------------------- (Insert State and Register No. for State in which the Work is to be performed) Subcontractor's License No. ------------------- Insert License No., if any, for State or locality in which the Work is to be performed) Subcontractor's OHIO State Sales Tax Registration No. ---------------- ---------------- (Job Location) Subcontractor's Federal I.D. No. ---------------- 7 40 In addition to Xxxxxx and the Owner, the Indemnified Parties throughout this Agreement shall include and any of their respective officers, agents, servants, or employees, and affiliates, parents and subsidiaries. Nothing contained in Article XXIII of this Agreement shall be deemed to obligate the Subcontractor to indemnify Xxxxxx, the Owner or any of the other Indemnified Parties, their officers, agents, servants, or employees, and affiliates, parents and subsidiaries, against liability for damages or any other loss, damage or expense sustained, suffered or incurred on account of death or bodily injury to active persons or injury to property caused by the negligence or willful misconduct of Xxxxxx, the Owner or any of the other Indemnified Parties, their officers, agents, servants, or employees, and affiliates, parents and subsidiaries, or other subcontractors directly responsible to Xxxxxx. Therefore, if it is determined, by legal proceedings or agreement, that the Subcontractor has no direct contributory or incidental negligence or other obligation to Xxxxxx, the Owner, or any Indemnified Party, and that the Subcontractor is in no way a proper party to a particular claim, then the Subcontractor shall not be obligated to hold Xxxxxx, the Owner or any Indemnified Party harmless with respect to said claim. However, until such determination is made by local proceedings or agreement, or if the Subcontractor is found to have any degree of direct or contributory negligence or if it is determined that the Subcontractor is in any way or to any degree a proper party to said claim, then the Subcontractor's obligations under all of the terms and provisions of Article XXIII shall remain in full force and effect except to the extent caused by the negligence of Xxxxxx, the Owner or any Indemnified Party. 8