Exhibit 10.3.27
ORMESA IE
10-21-88
EXECUTION COPY
PLANT CONNECTION AGREEMENT
FOR THE
ORMESA IE GEOTHERMAL POWER PLANT
BETWEEN
IMPERIAL IRRIGATION DISTRICT
AND ORMESA IE
EXECUTION COPY
10-21-88
TABLE OF CONTENTS
SECTION TITLE PAGE
------- ----- ----
1 PARTIES ........................................................ 1
2 RECITALS ....................................................... 1
3 AGREEMENT ...................................................... 2
4 DEFINITIONS .................................................... 2
5 EFFECTIVE DATE AND TERM ........................................ 3
6 CONNECTION OF PLANT ............................................ 3
7 ELECTRIC SERVICE TO PRODUCER ................................... 3
8 METERING OF ENERGY DELIVERIES .................................. 3
9 PRODUCERS DELIVERY AND ACCEPTANCE OF ENERGY FROM PLANT ......... 4
10 PRODUCER'S GENERAL OBLIGATIONS ................................. 4
11 IID'S GENERAL OBLIGATIONS ...................................... 5
12 BILLING ........................................................ 6
13 AUTHORIZED REPRESENTATIVES ..................................... 6
14 METERS ......................................................... 7
15 CONTINUITY OF SERVICE .......................................... 8
16 LIABILITY ...................................................... 9
17 UNCONTROLLABLE FORCES .......................................... 10
18 INTEGRATION AND AMENDMENTS ..................................... 11
19 NON-WAIVER ..................................................... 11
20 NO DEDICATION OF FACILITIES .................................... 12
21 SUCCESSORS AND ASSIGNS ......................................... 12
22 EFFECT OF SECTION HEADINGS ..................................... 12
23 GOVERNING LAW .................................................. 13
i
24 ARBITRATION .................................................... 13
25 ENTIRE AGREEMENT ............................................... 15
26 NOTICES ........................................................ 15
27 SEVERAL OBLIGATIONS ............................................ 15
28 SIGNATURE CLAUSE ............................................... 16
ATTACHMENTS
EXHIBIT "A" - RATE SCHEDULES GL AND A2 ......................... 17
EXHIBIT "B" - METERING ONE-LINE DIAGRAM ........................ 21
ii
1. PARTIES
The parties to this Agreement are IMPERIAL IRRIGATION DISTRICT ("IID"),
organized under the Water Code of the State of California and ORMESA IE
("Producer"), hereinafter referred to individually as "Party", and collectively
as "Parties".
2. RECITALS
2.1 Producer intends to construct and operate, as owner or lessee, a
generating facility with a maximum 9 megawatt net operating capacity at the East
Mesa (KGRA), Imperial County, California, and to sell the Plant electrical
output to Southern California Edison Company ("SCE").
2.2 SCE entered into the Power Purchase Agreement dated July 18, 1984
("Purchase Agreement"), with Republic Geothermal, Inc. ("Republic"). Republic
assigned the Power Purchase Contract to Ormat Systems, Inc. on November 6, 1984
to which assignment SCE consented on December 19, 1984. Ormat Systems, Inc.
assigned the Power Purchase Contract to Owners Geothermal on February 27, 1985
to which assignment SCE consented on July 22, 1985.
2.3 SCE and Producer agree that the terms and conditions regarding
transmission of the Plant's Energy to an IID/SCE point of interconnection shall
be pursuant to a Transmission Service Agreement to be entered into between IID
and Ormesa Geothermal.
2.4 Since the Plant will be built in the IID service territory, it will be
convenient to connect the Plant to the IID electric system.
Producer hereby grants the IID the right to enter the Plant site for
any reasonable purposes connected with this Agreement, by previous arrangements
with the Plant manager. Those reasonable purposes include maintenance and
repairs to IID equipment in Producer's facilities, observing tests of said
facilities, reading of kilowatt-hour meters, and the like.
2.5 Producer desires to purchase and IID desires to sell the electrical
energy necessary to satisfy the operation and maintenance power consumption
requirements of the Plant for the life of the Plant that is not normally
generated by the Plant itself, or portable generating equipment.
2.6 The Parties desire, by means of this Agreement, to interconnect the
Plant to the IID electrical system and to establish the terms, conditions and
obligations of the Parties relating to such interconnection.
3. AGREEMENT
The Parties agree as follows:
4. DEFINITIONS
4.1 Agreement: This Plant Connection Agreement between IID and Producer,
and all Exhibits hereto, as may be amended from time to time.
4.2 Authorized Representative: The representative of a Party designated in
accordance with Section 13.
4.3 Energy: Electric energy in excess of Producer's electric energy
requirements, expressed in kilowatt-hours, generated by the Plant and measured
and delivered to the Point of Delivery.
4.4 Funding and Construction Agreement: An agreement entered into by IID
and others dated June 29, 1987, providing for the funding and construction of
the Heber-Mirage Transmission Project, to which a form of this Agreement is
attached as Exhibit C.
4.5 Operation Date: The day on which the Plant Energy is first accepted by
IID for delivery to SCE.
4.6 Plant: A maximum of 9 MW net operating capacity Geothermal facility
operated by Producer, as owner or lessee, including all associated equipment and
improvements necessary for generating electric energy and transmitting it to the
high voltage side of the power transformer.
4.7 Point of Delivery: The point on the high voltage side of Producer's
switchyard where IID's metering equipment measures the delivery of Energy to the
IID system as shown on Exhibit "B".
4.8 System Emergency: A condition on IID'S system which is likely to result
in imminent significant disruption of service to customers or is imminently
likely to endanger life or property.
5. EFFECTIVE DATE AND TERM
This Agreement shall become effective upon the Operation Date of the Plant,
and shall remain in effect until the earlier of (i) October 12, 2017, or (ii)
thirty six (36) months from the date the Plant has ceased to operate at the
option of IID. It is understood that (i) if the Completion Date, as the term
Completion Date is defined In Article I of Funding and Construction Agreement
does not occur, or (ii) if the Operation Date does not occur within five (5)
years after the date this Agreement was executed, this Agreement shall be of no
force or effect.
6. CONNECTION OF PLANT
6.1 Producer may electrically connect its Plant, in accordance with the
provisions of this Agreement, so that it can operate in parallel with the IID
electric system. Parallel operation will not commence until IID has inspected
and approved the interconnection facilities and operational procedures.
6.2 Notwithstanding the provision that Producer has furnished the high
voltage switchyard complete, including the high voltage oil circuit breakers and
disconnect switches, the control of the high voltage oil circuit breakers and
disconnect switches shall be under the control of the IID dispatcher.
2
7. ELECTRIC SERVICE TO PRODUCER
IID shall provide electric service to Producer pursuant to Section 12.
8. METERING OF ENERGY DELIVERIES
Metering for electric service to Producer and for energy deliveries by
Producer to IID for delivery to SCE shall be at the Point of Delivery as shown
on Exhibit "B." Four meters shall be installed which shall measure and record
flows in each direction as shown on Exhibit "B."
9. PRODUCER'S DELIVERY AND IID ACCEPTANCE OF ENERGY FROM PLANT
Whenever electric output from the Plant exceeds Producer's power
requirements, Producer shall deliver all such excess output to IID for delivery
to SCE and IID shall accept such output for delivery to SCE and deliver such
output to SCE pursuant to a transmission service agreement to be entered into
between Ormesa Geothermal and IID.
10. PRODUCER'S GENERAL OBLIGATIONS
Producer shall:
10.1 Operate the Plant in a manner consistent with applicable electric
utility industry standards, good engineering practice, and without degradation
of quality or reliability of service to IID customers.
10.2 Deliver the Plant's net electrical output to IID for the account of
SCE at the Point of Delivery.
10.3 Each Party shall provide the reactive kilovolt-ampere (KVA)
requirements of its own system so that there will be no interchange of reactive
KVA between systems. The Parties shall cooperate to control the flow of reactive
KVA to prevent the introduction of objectionable operating conditions on the
system of either Party.
10.4 Coordinate, to the greatest extent practicable, major overhaul and
inspection outages of the Plant with IID.
10.5 Give IID a written schedule on or before June 1, and December 1, each
year of the estimated amounts and rates of delivery of energy to be delivered to
IID for the account of SCE at the Point of Delivery during each month of the
succeeding twelve-month (12) period commencing July 1, and January 1.
10.6 Give IID a written schedule on or before the fifteenth (15th) day of
each month of the estimated amounts and rates of delivery of energy to be
delivered to IID for the account of SCE at the Point of Delivery during each day
of the succeeding calendar month.
10.7 Give IID a schedule on or before 12:01 p.m. on Tuesday of each
seven-day (7) period of the estimated amounts and rates of delivery of energy to
be delivered to IID for the account of SCE at the Point of Delivery during each
hour of the succeeding seven-day (7) period
3
commencing at 12:01 a.m. on the following Monday; provided, however, that if any
changes in the hourly deliveries so scheduled become necessary, Producer shall
notify IID of such changes as far in advance as possible.
10.8 Provide IID any reasonable rights-of-way and access required for
testing and reading of meters by previous arrangement with the Plant manager.
10.9 Carry out the directions of the Authorized Representatives with
respect to the matters set forth in this Agreement.
11. IID'S GENERAL OBLIGATIONS
IID shall:
11.1 Design, acquire, construct, operate and maintain, or cause to be
designed, acquired, constructed, operated and maintained, and shall own, a
connecting transmission line between IID's transmission system and the Plant.
Following the completion of such line, IID may xxxx and Producer shall pay IID's
costs of designing, acquiring and constructing such line. Producer shall have
the right to audit IID's records and accounts to verify the cost of such line.
11.2 Accept the Plant's net electrical output for the account of SCE at the
Point of Delivery and simultaneously deliver an equal amount of electric energy
(less applicable transmission losses) to the SCE system at IID/SCE point(s) of
interconnection.
11.3 Coordinate, to the greatest extent practicable, major overhaul and
inspection outages of IID transmission facilities with Producer and notify
Producer of any changes as far in advance as possible.
11.4 Carry out the directions of the Authorized Representative with respect
to the matters set forth in this Agreement.
11.5 Operate its system in a manner consistent with applicable utility
industry standards and good engineering practices.
12. BILLING
12.1 IID shall read the meters monthly according to its regular meter
reading schedule beginning no more than thirty (30) days after the date that
electric energy is first supplied to Producer. IID monthly shall send Producer
within ten (10) working days after the meter is read a xxxx for electric
service. Producer shall pay IID the total amount billed within thirty (30) days
of receipt of the xxxx.
12.2 IID shall xxxx Producer for Producer's consumption of energy from
IID's resources in accordance with Rate Schedule GL or Rate Schedule A-2, as
applicable, as it may be revised from time to time. Copies of current Rate
Schedule GL and current Rate Schedule A-2 are attached as Exhibit "A."
4
12.3 If Producer disputes a xxxx, payment shall be made as if no dispute
existed pending resolution of the dispute by the Authorized Representatives. If
the xxxx is determined to be in error, the disputed amount shall be refunded by
IID including interest at the rate of one and one-half percent (1 1/2%) per
month, compounded monthly, from the date of payment to the date the refund check
or adjusted xxxx is mailed.
13. AUTHORIZED REPRESENTATIVES
13.1 Within thirty (30) days after the date this Agreement is signed, each
Party shall designate, by written notice to the other Party, an Authorized
Representative who is authorized to act in its behalf in the implementation of
this Agreement and with respect to those matters contained herein which are the
functions and responsibilities for the Authorized Representatives. Either Party
may, at any time, change the designation of its Authorized Representative by
written notice to the other Party.
13.2 IID's Authorized Representative shall develop detailed written
procedures necessary and convenient to administer this Agreement within six (6)
months after the date signed. Such procedures shall be submitted to Producer's
Authorized Representative for review, comment, discussion and concurrence before
they are put into effect. Such procedures shall include, without limitation: (i)
communication between Producer and IID's electric system dispatcher with regard
to daily operating matters, (ii) billing and payments, (iii) specified equipment
tests, and (iv) operating matters which affect or may affect quality and
reliability of service to electric customers and continuity of deliveries to
SCE.
13.3 The Authorized Representative shall have no authority to modify any of
the provisions of this Agreement.
14. METERS
14.1 All meters shall be sealed and the seal shall be broken only upon
occasions when the meters are to be inspected, tested or adjusted.
14.2 IID shall inspect and test all meters upon their installation and at
least once every year thereafter. If requested to do so by Producer, IID shall
inspect or test a meter more frequently than every year, but the expense of such
inspection or test shall be paid by Producer unless the meter is found to
register inaccurately by more than two percent (2%) from the measurement made by
a standard meter. Each Party shall give reasonable notice to the other Party of
the time when any inspection or test shall take place and that Party may have
representatives present at the test or inspection. If a meter is found to be
inaccurate or defective, it shall be adjusted, repaired or replaced in order to
provide accurate metering. All adjustments due to inaccurate meters shall be
limited to the preceding six (6) months.
14.3 If a meter fails to register, or if the measurement made by a meter
during a test varies by more than two percent (2%) from the measurement made by
the standard meter used in the test, adjustment shall be made correcting all
measurements made by the inaccurate meter for:
(i) the actual period during which inaccurate measurements were made,
if the period can be determined, or if not,
5
(ii) the period immediately preceding the test of the meter equal to
one-half (1/2) the time from the date of the last previous test
of the meter; provided, however, that the period covered by the
correction shall not exceed six (6) months.
14.4 Producer shall telemeter information to IID's Dispatch Center
regarding the kilowatts, kilowatt-hours, kilovars and kilovar-hours delivered to
or received from IID at the Point of Delivery over phone line leased by
Producer.
IID shall purchase, own, and shall design, install, operate, maintain,
or cause to be designed, installed, operated, and maintained, equipment to
automatically transmit from the Plant to IID's Dispatch Center continuous values
of Plant output expressed as megawatts, megavars and megawatt-hours. IID may
thereupon xxxx and Producer shall promptly pay IID's cost of design, purchase
and installation of said equipment. Producer shall have the right to audit IID's
records and accounts to verify the cost of said equipment.
15. CONTINUITY OF SERVICE
IID shall not be obligated to accept and IID may require Producer to
temporarily curtail, interrupt or reduce deliveries of energy upon advance
notice to Producer, when such curtailment, interruption or reduction is required
in order for IID to construct, install, maintain, repair, replace, remove,
investigate or inspect any of its equipment or any part of its system or if IID
determines that such curtailment, interruption or reduction is necessary because
of a System Emergency, forced outages or abnormal operating conditions on its
system. IID shall use reasonable efforts to keep interruptions and curtailments
to a minimum time.
16. LIABILITY
16.1 Except for any loss, damage, claim, costs, charge or expense resulting
from Willful Action, neither Party (the "released Party"), its directors or
other governing body, officers or employees shall be liable to the other Party
for any loss, damage, claim, cost, charge, or expense of, any kind or nature
incurred by the other Party (including direct, indirect or consequential loss,
damage, claim, cost, charge or expense; and whether or not resulting from the
negligence of a Party, its directors or other governing body, officers,
employees or any person or entity whose negligence would be imputed to a Party)
from engineering, repair, supervision, inspection, testing, protection,
operation, maintenance, replacement, reconstruction, use or ownership of the
released Party's electrical system, Plant(s) or associated facilities in
connection with the implementation of this Agreement. Except for any loss,
damage, claim, cost, charge or expense resulting from Willful Action, each Party
releases the other Party, its directors or other governing body, officers and
employees from any such liability.
16.2 For the purpose of this Section 16, Willful Action shall be defined as
action taken or not taken by a Party at the direction of its directors or other
governing body, officers or employees having management or administrative
responsibility affecting its performance under this Agreement, as follows:
6
16.2.1 Action which is knowingly or intentionally taken or not taken
with conscious indifference to the consequences thereof or with intent that
injury or damage would result or would probably result therefrom.
16.2.2 Action which has been determined by final arbitration award or
final judgment or judicial decree to be a material default under this Agreement
and which occurs or continues beyond the time specified in such arbitration
award or judgment or judicial decree for curing such default or, if no time to
cure is specified therein, occurs or continues thereafter beyond a reasonable
time to cure such default.
16.2.3 Action which is knowingly or intentionally taken or not taken
with the knowledge that such action taken or not taken is a material default
under this Agreement.
16.3 Willful Action does not include any act or failure to act which is
merely involuntary, accidental or negligent.
16.4 The phrase "employees having management or administrative
responsibility," as used in Section 16.2, means the employees of a Party who are
responsible for one or more of the executive functions of planning, organizing,
coordinating, directing, controlling and supervising such Party's performance
under this Agreement with responsibility for results.
16.5 Subject to the foregoing provisions of this Section 16, each Party
agrees to defend, indemnify and save harmless the other Party, its officers,
agents, or employees against all losses, claims, demands, costs or expenses for
loss of or damage to property, or injury or death of persons, which directly or
indirectly arise out of the indemnifying Party's performance pursuant to this
Agreement; provided, however, that a Party shall be solely responsible for any
such losses, claims, demands, costs or expenses which result from its sole
negligence or Willful Action.
17. UNCONTROLLABLE FORCES
Neither Party shall be considered to be in default in the performance of
any of its obligations under this Agreement when a failure of performance shall
be due to an uncontrollable force. The term "uncontrollable force" shall mean
any cause beyond the control of the Party affected including, but not restricted
to, failure of or threat of failure of facilities which have been maintained in
accordance with generally accepted engineering and operating practices in the
electrical utility industry, flood, drought, earthquake, tornado, storm fire,
pestilence, lightning and other natural catastrophes, epidemic, war, riot, civil
disturbance or disobedience, strike, labor dispute, labor or material shortage,
sabotage, government priorities and restraint by court order or public authority
(whether valid or invalid) and actions or nonaction by or inability to obtain or
keep the necessary authorizations or approvals from any governmental agency or
authority, which by exercise of due diligence such Party could not reasonably
have been expected to avoid and which by exercise of due diligence it has been
unable to overcome. Nothing contained herein shall be construed as to require a
Party to settle any strike or labor dispute in which it may be involved. Either
Party rendered unable to fulfill any of its obligations under this Agreement by
reason of an uncontrollable force shall give prompt written notice of such fact
to the other Party and shall exercise due diligence to remove such inability
with all reasonable dispatch.
7
18. INTEGRATION AND AMENDMENTS
This Agreement constitutes the entire agreement between the Parties
relating to the interconnection of Producer's Plant to IID's electric system,
the acceptance of energy by IID from Producer and the providing of electric
service by IID. No oral agreement or prior written agreement between the Parties
shall be of any effect whatsoever; provided, however, that any arrangements
agreed upon by the Authorized Representatives within the limits of their
authority, and consistent with this Agreement shall be binding upon the Parties.
All changer to this Agreement shall be in writing and shall be signed by an
officer of each Party.
19. NON-WAIVER
None of the provisions of this Agreement shall be considered waived by
either Party except when such waiver is given in writing. The failure of either
Party to insist in any one or more instances upon strict performance of any of
the provisions of this Agreement or to take advantage of any of its rights
hereunder shall not be construed as a waiver of any such provisions or the
relinquishment of any such rights for the future; but the same shall continue
and remain in full force and effect.
20. NO DEDICATION OF FACILITIES
Any undertaking by one Party to the other Party under any provision of this
Agreement shall not constitute the dedication of the system or any portion
thereof by the Party to the public or to the other Party, and it is understood
and agreed that any such undertaking under any provision of this Agreement by a
Party shall cease upon the termination of its obligations hereunder.
21. SUCCESSORS AND ASSIGNS
21.1 This Agreement shall be binding upon and inure to the benefit of the
respective successors and assigns of the Parties.
21.2 This Agreement may be assigned by Producer only (i) to a purchaser or
co-owner of the Plant or to a person who will operate the Plant pursuant to a
contract or other arrangement with such purchaser and in either case with the
prior written consent of IID (which shall not be unreasonably withheld) or (ii)
for security purposes, to a bank or other entity which provides financing for
the Plant or any electrical transmission facilities associated therewith.
Producer and IID agree that nothing in this Section 21.2 may be amended,
modified or waived without the prior written consent of each and every Party to
the Funding and Construction Agreement (except for any Parties in default
thereunder).
22. EFFECT OF SECTION HEADINGS
Section headings appearing in this Agreement are inserted for convenience
only, and shall not be construed as interpretations of text.
8
23. GOVERNING LAW
This Agreement shall be interpreted, governed and construed under the laws
of the State of California or the laws of the United States, as applicable.
24. ARBITRATION
24.1 Any dispute arising out of or relating to this Agreement, or the
breach thereof, which is not resolved by the Parties acting through their
Authorized Representatives shall be settled by arbitration to the extent
permitted by the laws applicable to the Parties; provided, however, that no
Party to the dispute shall be bound to any greater extent than any other Party
to the dispute. Arbitration shall not apply to any dispute or matter that is
within the jurisdiction of any regulatory agency.
24.2 Any demand for arbitration shall be made by written notice to the
other Party setting forth in adequate detail the nature of the dispute, the
issues to be arbitrated, the amount or amounts, if any, involved In the dispute,
and the remedy sought. Within twenty (20) days from the receipt of such notice,
the other Party may submit its own written statement of the dispute and may set
forth in adequate detail any additional related matters or issues to be
arbitrated.
24.3 Within thirty (30) days after delivery of the written notice demanding
arbitration, the Parties acting through their Authorized Representatives shall
meet for the purpose of selecting an arbitrator. The Parties may agree upon a
single arbitrator, but in the event that they cannot agree, three arbitrators
shall be used. Each Party shall designate one arbitrator, and the two
arbitrators shall then select a third arbitrator. All arbitrators shall be
persons skilled and experienced in the field in which the dispute has arisen and
no person shall be eligible for appointment as an arbitrator who is or has been
an officer or employee of either of the Parties or otherwise interested in the
matter to be arbitrated. Should either party refuse or neglect to appoint an
arbitrator or to furnish the arbitrators with any papers or information
demanded, the arbitrators are empowered, by both Parties, to proceed without the
participation or assistance of that Party.
24.4 Except as otherwise provided in this Section, the arbitration shall be
governed by the rules and practices of the American Arbitration Association, or
a similar organization if the American Arbitration Association should not at the
time exist.
24.5 Arbitration proceedings shall be held in Imperial, California, at a
time and place to be selected by the arbitrators. The arbitrators shall hear
evidence submitted by the Parties and may call for additional information which
shall be furnished by the Party having such information. The arbitrators shall
have no authority to call for information not related to the Issues included in
the dispute or to determine other issues not in dispute.
24.6 If there is only one arbitrator, his decision shall be binding and
conclusive on the Parties. If there are three arbitrators, the decision of any
two shall be binding and conclusive. The decision of the arbitrators shall
contain findings regarding the issues involved in the dispute, including the
merits of the positions of the Parties, the materiality of any default, and the
remedy or relief to which a Party shall be entitled. The arbitrators may not
grant any remedy or relief
9
which is inconsistent with this Agreement, nor shall the arbitrators make
findings or decide issues not in dispute.
24.7 The fees and expenses of the arbitrators shall be shared equally by
the Parties, unless the decision of the arbitrators specifies some other
apportionment. All other expenses and costs of the arbitration shall be borne by
the Party incurring such expenses and costs.
24.8 Any decision or award granted by the arbitrators shall be final and
judgement may be entered on it in any court of competent jurisdiction. This
agreement to arbitrate shall be specifically enforceable.
25. ENTIRE AGREEMENT
25.1 The complete agreement of the Parties is set forth in this Agreement
and all communications regarding subject interconnected operations whether oral
or written, are hereby abrogated and withdrawn.
26. NOTICES
Any formal communication or notice in connection with this Agreement shall
be in writing and shall be deemed properly given if delivered in person or sent
first class mail, postage prepaid to the person specified below:
ORMESA IE
c/o Plant Manager
X.X. Xxx 000
Xx Xxxxxx, Xxxxxxxxxx 00000
IMPERIAL IRRIGATION DISTRICT
c/o General Manager
X.X. Xxx 000
Xxxxxxxx, Xxxxxxxxxx 00000
27. SEVERAL OBLIGATIONS
Except where specifically stated in this Agreement to be otherwise, the
duties, obligations and liabilities of the Parties are intended to be several
and not joint or collective. Nothing contained in this Agreement shall ever be
construed to create an association, trust, partnership or joint venture, or
impose a trust or partnership duty, obligation or liability on or with regard to
either Party. Each Party shall be individually and severally liable for its own
obligations under this Agreement.
10
28. SIGNATURE CLAUSE
The Parties have caused this Agreement to be executed in their respective
names, in duplicate, by their respective officers hereunto this _________ day of
____________________, 1988.
ORMESA IE
By AMOR V, Managing General Partner
By /s/ Indecipherable
-------------------------------------
Its V. President
------------------------------------
ATTEST:
By /s/ Indecipherable
-----------------------------------
Secretary
IMPERIAL IRRIGATION DISTRICT
By /s/ Indecipherable
-------------------------------------
President, Board of Directors
ATTEST:
By /s/ Xxxxx X. Xxxx
-----------------------------------
Secretary
11
EXHIBIT "A"
IMPERIAL IRRIGATION DISTRICT Revised Sheet No. 000
Xxxxxxxx, Xxxxxxxxxx Cancelling Sheet No. 139
SCHEDULE A-2
GENERAL WHOLESALE POWER SERVICE
APPLICABILITY
Applicable to general wholesale power service for industrial, commercial
and agricultural purposes, subject to special conditions hereinafter
stated.
Applicable to standby or breakdown service where the entire electric power
requirements on the customer's premises are not regularly supplied by the
District.
MONTHLY RATE
The monthly rate shall be the sum of A, B, C and D.
A. Demand Charge .................. $2.52 per kilowatt of Billing Demand
B. Energy Charge................... 5.60CENTS per kwh.
C. Energy Cost Adjustment -
The amount computed in accordance with Schedule ECA.
D. Power Factor Adjustment -
A charge of $0.25 per kilovar of reactive demand as measured by
the incoming kilovar demand meter for each kilovar in excess of
.60 times the kilowatt demand measured and supplied by the
District.
MINIMUM CHARGE
The minimum charge shall be the demand charge, but in no case shall the
minimum charge be less than the demand charge (A) multiplied by 75% of the
highest maximum demand established in the preceding 11 months.
SPECIAL CONDITIONS
(a) Voltage: This schedule applies to service rendered at a transmission
voltage of 34.5-kV or above. It shall be the responsibility of the
customer to furnish transformation to any other voltages required.
(b) Billing Demand: The billing demand shall be the kilowatts of measured
maximum demand but in no case less than 75 percent of the highest
maximum demand established in the preceding 11 months. The measured
maximum demand in any month will be the average kilowatt delivery
indicated or recorded by the District's demand meter in the 15-minute
interval in which such delivery is greater than any other 15-minute
interval. In case the load is intermittent or subject to violent
fluctuations, the District may base the demand upon a 5-minute
interval instead of a 15-minute interval.
Board Resolution -17- Date Effective
July 3, 1984 August 1, 1984
IMPERIAL IRRIGATION DISTRICT Revised Sheet No. 000
Xxxxxxxx, Xxxxxxxxxx Cancelling Sheet No. 139
SCHEDULE A-2 (Continued)
GENERAL WHOLESALE POWER SERVICE
(c) A minimum connected load of 5000 kw shall be required.
(d) Parallel Operation: A customer may operate its generating plant in
parallel with the District's system if such customer installs and
operates such control and protective equipment as required by the
District.
(e) Metering: The District will provide the normal metering equipment for
the size and type of load served. Additional metering which may be
required by the District shall be furnished by the customer and tested
in accordance with requirements of the District. Meters shall not
allow reverse registration.
(f) Regulations Governing Sale of Electric Energy: Service under this rate
schedule is subject to the District's Regulations Governing the Sale
of Electric Energy.
Board Resolution -18- Date Effective
July 3, 1984 August 1, 1984
EXHIBIT "A"
IMPERIAL IRRIGATION DISTRICT Revised Sheet No. 000
Xxxxxxxx, Xxxxxxxxxx Cancelling Sheet No. 137
SCHEDULE GL
LARGE GENERAL SERVICE
APPLICABILITY
Applicable to general service having a demand of 100 kilowatts or
higher. Not applicable for standby, supplemental or resale service.
MONTHLY RATE
The monthly rate shall be the sum of A, B and C.
A. Demand Charge ................... $2.65 per kilowatt of Billing Demand
B. Energy Charge.................... 5.90CENTS per kwh
C. Energy Cost Adjustment -
The amount computed in accordance with Schedule ECA.
SPECIAL CONDITIONS
(a) Voltage: Service under this schedule normally will be supplied at
standard voltage available at the location. Where 240-volt three-
phase power is to be combined with single-phase, and 4-wire
service is available, service will be supplied through one meter.
In 240-volt areas, where, as determined by District, it is not
practical to provide a 4-wire service, such single-phase and
three-phase service will be supplied and metered separately, the
meter readings, both kwh and demands, being combined for the
purpose of computing charges on this schedule. Where service is
taken at 480-volts or higher, a three-phase service at one
voltage only will be supplied.
(b) Billing Demand: The billing demand shall be the higher of (i) the
highest 15-minute integrated or thermal kilowatt demand measured
during the billing period, or (ii) 50% of highest demand measured
during the five summer months (May-September) of the 12-months
ending with the current month, or (iii) 20% of the highest
measured demand during the seven winter months (October-April) of
the 12-months ending with the current month, or (iv) the demand
specified in a contract, or (v) 50 kilowatts.
When the monthly demand exceeds 100 KW in any billing month,
billing will be under Rate Schedule GL, and thereafter continue
under Rate Schedule GL until monthly demands have been less than
100 KW for a period of twelve consecutive months.
Board Resolution -19- Date Effective
January 18, 1983 February 1, 1983
EXHIBIT B
---------
[Graphic: Simplified Switch Connection Diagram]
Imperial Irrigation District:
Ormesa 1, 1E & 1H - L.L.D. One Line Diagram