Induction Generators definition

Induction Generators. Motoring Power (kW): I22t or K (Heating Time Constant): Rotor Resistance, Rr: Stator Resistance, Rs: Stator Reactance, Xs: Rotor Reactance, Xr: Magnetizing Reactance, Xm: Short Circuit Reactance, Xd’’: Exciting Current: Temperature Rise: Frame Size: Design Letter: Reactive Power Required In Vars (No Load): Reactive Power Required In Vars (Full Load): Total Rotating Inertia, H: Per Unit on kVA Base Note: Please contact the Utility prior to submitting the Interconnection Request to determine if the specified information above is required. Interconnection Facilities Information Will more than one transformer be used between the generator and the point of common coupling? Yes No (If yes, copy this section and provide the information for each transformer used. This information must match the single-line drawing and transformer specification sheets.) Will the transformer be provided by the Interconnection Customer? Yes No Transformer Data (if applicable, for Interconnection Customer-owned transformer): Is the transformer: Single phase Three phase Size: kVA Transformer Impedance: % on kVA Base If Three Phase: Transformer Primary Winding Volts, ❑ Delta ❑ WYE, grounded neutral ❑ WYE, ungrounded neutral Primary Wiring Connection ❑ 3-wire ❑ 4-wire, grounded neutral Transformer Secondary Winding Volts, ❑ Delta ❑ WYE, grounded neutral ❑ WYE, ungrounded neutral Secondary Wiring Connection ❑ 3-wire ❑ 4-wire, grounded neutral Transformer Tertiary Winding Volts, ❑ Delta ❑ WYE, grounded neutral ❑ WYE, ungrounded neutral Transformer Fuse Data (if applicable, for Interconnection Customer-owned fuse): (Attach copy of fuse manufacturer’s Minimum Melt and Total Clearing Time-Current Curves) Manufacturer: Type: Size: Speed: Interconnecting Circuit Breaker (if applicable): Manufacturer: Type: Load Rating (Amps): Interrupting Rating (Amps): Trip Speed (Cycles): Interconnection Protective Relays (if applicable):
Induction Generators. Motoring Power (kW): I 2t or K (Heating Time Constant): Rotor Resistance, Rr: Stator Resistance, Rs: Stator Reactance, Xs: Rotor Reactance, Xr: Magnetizing Reactance, Xm: Short Circuit Reactance, Xd'': Exciting Current: Temperature Rise: Frame Size: Design Letter: Reactive Power Required In Vars (No Load): Reactive Power Required In Vars (Full Load): Total Rotating Inertia, H: Per Unit on kVA Base Note: Please contact the Transmission Provider prior to submitting the Interconnection Request to determine if the specified information above is required.
Induction Generators. Motoring Power (kW): I22t or K (Heating Time Constant): Rotor Resistance, Rr: Stator Resistance, Rs: Stator Reactance, Xs: Rotor Reactance, Xr: Magnetizing Reactance, Xm: Short Circuit Reactance, Xd: Exciting Current: Temperature Rise: Frame Size: Design Letter: Reactive Power Required In Vars (No Load): Reactive Power Required In Vars (Full Load): Total Rotating Inertia, H: Per Unit on kVA Base Note: Please contact the Utility prior to submitting the Interconnection Request to determine if the specified information above is required. Interconnection Facilities Information Will more than one transformer be used between the generator and the point of common coupling? Yes No (If yes, copy this section and provide the information for each transformer used. This information must match the single-line drawing and transformer specification sheets.) For identical transformers, one set of data may be provided.) Will the transformer be provided by the Interconnection Customer? Yes No Transformer Data (if applicable, for Interconnection Customer-owned transformer): Is the transformer: Single phase Three phase Size: kVA Transformer Impedance: % on kVA Base If Two Winding:

Examples of Induction Generators in a sentence

  • Induction Generators (except self-excited Induction generators) do not require a synchronizing function.


More Definitions of Induction Generators

Induction Generators. Motoring Power (kW): I 2t or K (Heating Time Constant): Rotor Resistance, Rr: Stator Resistance, Rs: Stator Reactance, Xs: Rotor Reactance, Xr: Magnetizing Reactance, Xm: Short Circuit Reactance, Xd'': Exciting Current: Temperature Rise: Frame Size: Design Letter:

Related to Induction Generators

  • Customer-generator means a user of a net metering system.

  • X-ray high-voltage generator means a device which transforms electrical energy from the potential supplied by the x-ray control to the tube operating potential. The device may also include means for transforming alternating current to direct current, filament transformers for the x-ray tube(s), high-voltage switches, electrical protective devices, and other appropriate elements.

  • Small quantity generator means a generator who generates less than 1000 kg of hazardous waste in a calendar month.

  • Generator means a device that produces electricity.

  • embedded generator means a generator who is not a market participant and whose generation facility is connected to a distribution system of a distributor, but does not include a generator who consumes more electricity than it generates;

  • Co-generation means the sequential production of electricity

  • High voltage bus means the electrical circuit, including the coupling system for charging the REESS that operates on a high voltage.

  • Plasma arc incinerator means any enclosed device using a high intensity electrical discharge or arc as a source of heat followed by an afterburner using controlled flame combustion and which is not listed as an industrial furnace.

  • Basic generation service or "BGS" means electric generation

  • Sensor means any measurement device that is not part of the vehicle itself but installed to determine parameters other than the concentration of gaseous and particle pollutants and the exhaust mass flow.

  • Eligible customer-generator means a customer-generator whose net energy metering system for renewable resources, cogeneration, fuel cells, and microturbines meets all applicable safety and performance standards.

  • high voltage means the classification of an electric component or circuit, if its working voltage is > 60 V and ≤ 1500 V DC or > 30 V and ≤ 1000 V AC root mean square (rms).

  • Nitrogen oxides means nitric oxide and nitrogen dioxide, expressed as nitrogen dioxide (NO2);

  • Generator Maintenance Outage means the scheduled removal from service, in whole or in part, of a generating unit in order to perform necessary repairs on specific components of the facility, if removal of the facility meets the guidelines specified in the PJM Manuals.

  • Diatomaceous earth filtration means a process resulting in substantial particulate removal in which a precoat cake of diatomaceous earth filter media is deposited on a support membrane (septum), and while the water is filtered by passing through the cake on the septum, additional filter media known as body feed is continuously added to the feed water to maintain the permeability of the filter cake.