Maximum Discharging Capacity definition

Maximum Discharging Capacity. [XX] MW [number in MW representing the highest level at which the Storage Facility may be discharged] Minimum Discharging Capacity: [XX] MW [number in MW representing the lowest level at which the Storage Facility may be discharged] Maximum State of Charge (SOC) during Charging: 100% Minimum State of Charge (SOC) during Discharging: 0% Maximum Round-Trip Efficiency: [peak efficiency of conversion between charging energy and discharging energy (i.e. ratio of maximum charging energy to maximum discharging energy)] % If actual round-trip efficiency is greater than or equal to Maximum Round-Trip Efficiency, then for purposes of calculating the monthly payment amount, the actual round-trip efficiency will be deemed to be 100%. Minimum Round-Trip Efficiency: [minimum guaranteed efficiency of conversion between charging energy and discharging energy (i.e. ratio of maximum charging energy to maximum discharging energy)] % If actual round-trip efficiency is less than Minimum Round-Trip Efficiency, then for purposes of calculating the monthly payment amount, the actual round-trip efficiency will be deemed to be 0%.
Maximum Discharging Capacity has the meaning set forth in in Exhibit A.
Maximum Discharging Capacity. [___] MW [based on final system configuration, number in MW representing the highest level at which the Facility may be discharged] Minimum Discharging Capacity: 0.01 MW [number in MW representing the lowest level at which the Facility may be discharged] Maximum State of Charge (SOC) during Charging: 100% Minimum State of Charge (SOC) during Discharging: 0% Guaranteed Round-Trip Efficiency: Contract Year Guaranteed Round-Trip Efficiency 2 - XX [Seller to fill out rest of table] Liquidated Damages for Failure to Achieve Guaranteed Round-Trip Efficiency Rate: If during any month during the Delivery Term, the Actual Round-Trip Efficiency for such month is less than the Guaranteed Round-Trip Efficiency, Seller shall owe liquidated damages to Buyer, which damages shall be calculated by multiplying (i) the total Charging Energy for such month, by (ii) the percentage amount by which the Actual Round-Trip Efficiency is less than the Guaranteed Round-Trip Efficiency, by (iii) the simple average of the Day-Ahead Market locational marginal price for all the hours of the applicable month, as published by the CAISO, for the Delivery Point, provided, however, that no liquidated damages shall be payable under this provision if the Round-Trip Efficiency Factor for such month is zero percent (0%). Minimum Round-Trip Efficiency: [70]%

Examples of Maximum Discharging Capacity in a sentence

  • At all times during a SCT, the Facility shall be operated in compliance with Prudent Operating Practices and all operating protocols recommended, required or established by the manufacturer for operation at Maximum Discharging Capacity and Maximum Charging Capacity (as each is defined in Exhibit A).

  • At all times during a SCT, the Storage Facility shall be operated in compliance with Prudent Operating Practices and all operating protocols recommended, required or established by the manufacturer for operation at Maximum Discharging Capacity and Maximum Charging Capacity (as each is defined in Exhibit A).

  • At all times during a SCT, the Storage Facility shall be operated in compliance with Prudent Industry Practices and all operating protocols recommended, required or established by the manufacturer for operation at Maximum Discharging Capacity and Maximum Charging Capacity (as each is defined in Exhibit A).

  • At all times during a SCT, the Facility shall be operated in compliance with Prudent Operating Practices and all operating protocols recommended, required or established by the manufacturer for operation at Maximum Discharging Capacity and Maximum Charging Capacity.

  • At all times during a SCT, the Storage Facility shall be operated in compliance with Prudent Operating Practices and all operating protocols recommended, required or established by the manufacturer for operation at Maximum Discharging Capacity and Maximum Charging Capacity.


More Definitions of Maximum Discharging Capacity

Maximum Discharging Capacity means the highest level at which the Facility may be discharged, expressed in MW and as set forth in Exhibit Q.
Maximum Discharging Capacity. [___] MW [based on final system configuration, number in MW representing the highest level at which the Facility may be discharged] Minimum Discharging Capacity: 0.01 MW [number in MW representing the lowest level at which the Facility may be discharged] Maximum State of Charge (SOC) during Charging: 100% Minimum State of Charge (SOC) during Discharging: 0% Guaranteed Round-Trip Efficiency: Contract Year Guaranteed Round-Trip Efficiency 2 - XX [Seller to fill out rest of table]
Maximum Discharging Capacity. [XX] MW [number in MW representing the highest level at which the Storage Facility may be discharged] Minimum Discharging Capacity: [XX] MW [number in MW representing the lowest level at which the Storage Facility may be discharged] Maximum State of Charge (SOC) during Charging: 100 % Minimum State of Charge (SOC) during Discharging: 0 %
Maximum Discharging Capacity has the meaning set forth in Exhibit A. “Maximum Stored Energy Level” has the meaning set forth in Exhibit O. “Meter Service Agreement” has the meaning set forth in the CAISO Tariff.
Maximum Discharging Capacity. [XX] MW [number in MW representing the highest level at which the Storage Facility may be discharged] Minimum Discharging Capacity: [XX] MW [number in MW representing the lowest level at which the Storage Facility may be discharged] Maximum State of Charge (SOC) during Charging: 100% Minimum State of Charge (SOC) during Discharging: 0% Other Operating Limits: [Seller to describe all applicable operating limits on dispatch of the Storage Facility, if any] Ancillary Services Capability: [Seller to describe capability of Storage Facility to provide CAISO Ancillary Services, e.g., Regulation, Spinning Reserve, Non-Spinning Resource, and Voltage Support, and other ancillary services that may be developed from time to time.]