Rated Power Factor definition

Rated Power Factor. Leading: Lagging: Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: Elevation: Single phase Three phase Inverter Manufacturer, Model Name, & Number (if used): List of adjustable set points for the protective equipment or software: Note: A completed Power Systems Load Flow data sheet must be supplied with the Interconnection Request. Generating Facility Characteristic Data (for inverter-based machines) Max design fault contribution current: Instantaneous or RMS? Harmonics Characteristics: Start-up requirements: Generating Facility Characteristic Data (for rotating machines) RPM Frequency: (*) Neutral Grounding Resistor (if applicable): Synchronous Generators: Direct Axis Synchronous Reactance, Xd: Direct Axis Transient Reactance, X’d: Direct Axis Subtransient Reactance, X”d: Negative Sequence Reactance, X2: Zero Sequence Reactance, X0: P.U. P.U. P.U. P.U. P.U. KVA Base: Field Volts: Field Amperes: Induction Generators: Motoring Power (kW): I22t or K (Heating Time Constant): Rotor Resistance, Rr: Stator Resistance, Rs: Stator Reactance, Xs: Rotor Reactance, Xr: Magnetizing Reactance, Xm: Short Circuit Reactance, Xd’’: Exciting Current: Temperature Rise: Frame Size: Design Letter: Reactive Power Required In Vars (No Load): Reactive Power Required In Vars (Full Load): Total Rotating Inertia, H: Per Unit on kVA Base Note: Please contact GUC prior to submitting the Interconnection Request to determine if the specified information above is required.
Rated Power Factor. Leading: Lagging: Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: Elevation: Single phase Three phase Inverter Manufacturer, Model Name, & Number (if used): List of adjustable set points for the protective equipment or software: Note: A completed Power Systems Load Flow data sheet must be supplied with the Interconnection Request. Generating Facility Characteristic Data (for inverter-based machines) Max design fault contribution current: Instantaneous or RMS? Harmonics Characteristics: Start-up requirements: Generating Facility Characteristic Data (for rotating machines) RPM Frequency: (*) Neutral Grounding Resistor (if applicable): Synchronous Generators: Direct Axis Synchronous Reactance, Xd: Direct Axis Transient Reactance, X’d: Direct Axis Subtransient Reactance, X”d: Negative Sequence Reactance, X2: Zero Sequence Reactance, X0: P.U. P.U. P.U. P.U. P.U. KVA Base: Field Volts: Field Amperes: Induction Generators:
Rated Power Factor. Leading: Lagging: Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: Elevation: Single phase Three phase Inverter Manufacturer, Model Name & Number (if used): List of adjustable set points for the protective equipment or software: Note: A completed Power Systems Load Flow data sheet must be supplied with the Interconnection Request. Small Generating Facility Characteristic Data (for inverter-based machines) Max design fault contribution current: Instantaneous or RMS? Harmonics Characteristics: Start-up requirements: Small Generating Facility Characteristic Data (for rotating machines) RPM Frequency: (*) Neutral Grounding Resistor (If Applicable):

Examples of Rated Power Factor in a sentence

  • FACILITY 4.1 Contracted Plant Capacity and Output (as defined in the Draft TPPA)MW 4.2 Rated Power Factor Lagging 4.3 Agreed average monthly Station Availability (A Vb) (Where A Vb is defined in the TPPA) Bidders should note that the units may be required to generate at 100% load factor and should, therefore, provide sufficient number of units to meet this level of Availability.

  • Neutral Grounding Resistor (if applicable): INVERTER DATA (if applicable)Manufacturer: Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Amperes: Inverter Type (ferroresonant, step, pulse-width modulation, etc): Type commutation: forced lineHarmonic Distortion: Maximum Single Harmonic (%) Maximum Total Harmonic (%) Note: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms.

  • Neutral Grounding Resistor (if applicable): INVERTER DATA (if applicable) Manufacturer: Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Amperes: Inverter Type (ferroresonant, step, pulse-width modulation, etc): Type commutation: forced lineHarmonic Distortion: Maximum Single Harmonic (%) Maximum Total Harmonic (%) Note: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms.

  • THAT Council enact the necessary by-law assuming the municipal services that are set out in the Subdivision Agreement for Plan 65M-4202 and that the Municipal Services Letter of Credit be released.

  • This definition is subject to change based on the requirements of the 2021 HUD CoC Program Competition NOFA upon its release.

  • Copy this page as required for additional generators) INVERTER DATA (if applicable) Manufacturer: Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Amperes: Inverter Type (ferroresonant, step, pulse-width modulation, etc): Type commutation:forcedlineHarmonic Distortion: Maximum Single Harmonic (%) Maximum Total Harmonic (%) Note: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms.

  • With the proposed procedure, we obtained a detailed spatial quantification of T, Tg and Tu across the Sardón catchment per species readily usable as an input for hydrological models, such as the MARMITES model developed for understanding of the groundwater dynamics (Francés et al.

  • INVERTER DATA (if applicable) Manufacturer: Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Amperes: Inverter Type (ferroresonant, step, pulse-width modulation, etc): Type commutation: forced line Harmonic Distortion: Maximum Single Harmonic (%) Maximum Total Harmonic (%) Note: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms.

  • PC.A.5.3 Synchronous Machine and Associated Control System Data PC.A.5.3.1 The following Generating Unit and Power Station data should be supplied: (a) Generating Unit Parameters Rated terminal volts (kV)* Rated MVA∗ Rated MW∗ Rated Power Factor* Minimum Generation MW* Short circuit ratioDirect axis synchronous reactance* Direct axis transient reactanceDirect axis sub-transient reactance ……………Direct axis short-circuit transient time constant.

  • Copy this page as required for additional generators) INVERTER DATA (if applicable) Manufacturer: Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Amperes: Inverter Type (ferroresonant, step, pulse-width modulation, etc): Type commutation: forced lineHarmonic Distortion: Maximum Single Harmonic (%) Maximum Total Harmonic (%) Note: Attach all available calculations, test reports, and oscillograph prints showing inverter output voltage and current waveforms.


More Definitions of Rated Power Factor

Rated Power Factor. Leading: Lagging: Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: Elevation: Single phase Three phase Inverter Manufacturer, Model Name & Number (if used):
Rated Power Factor. Leading: ________________Lagging: __________________ Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: ______________ Elevation: _______________ Single phase ______ Three phase _____ Inverter Manufacturer, Model Name, & Number (if used): _______________________ List of adjustable set points for the protective equipment or software: _________________ Note: A completed Power Systems Load Flow data sheet must be supplied with the Interconnection Request. Generating Facility Characteristic Data (for inverter-based machines) Max design fault contribution current: _________ Instantaneous _____ or RMS? _____ Harmonics Characteristics: ________________________________________________ Start-up requirements: ___________________________________________________ Generating Facility Characteristic Data (for rotating machines) RPM Frequency: _________________ (*) Neutral Grounding Resistor (if applicable): ____________ Synchronous Generators: Direct Axis Synchronous Reactance, Xd: _____________ P.U. Direct Axis Transient Reactance, X’d: ______________ P.U. Direct Axis Subtransient Reactance, X”d: ______________ P.U. Negative Sequence Reactance, X2: ______________ P.U. Zero Sequence Reactance, X0: ______________________ P.U. KVA Base: __________________________________________ Field Volts: _________________________________________ Field Amperes: ______________________________________ Induction Generators: Motoring Power (kW): ___________________________________ I 22 t or K (Heating Time Constant): ______________________ Rotor Resistance, Rr: ___________________________________ Stator Resistance, Rs: ___________________________________ Stator Reactance, Xs: ___________________________________ Rotor Reactance, Xr: ___________________________________ Magnetizing Reactance, Xm: ____________________________ Short Circuit Reactance, Xd’’: ____________________________ Exciting Current: ___________________________________ Temperature Rise: ___________________________________ Frame Size: __________________________________ Design Letter: ___________________________________ Reactive Power Required In Vars (No Load): _______________ Reactive Power Required In Vars (Full Load): _______________ Total Rotating Inertia, H: _____________ Per Unit on kVA Base Note: Please contact the Cooperative prior to submitting the Interconnection Request to determine if the specified information above is required.
Rated Power Factor. Leading: Lagging: Inverter Information: Manufacturer: Model: Type: Forced Commutated Line Commutated Electric Nameplate Capacity Rated Output: Efficiency: % Power Factor: % Amps Volts kW DC Source:

Related to Rated Power Factor

  • Power Factor means the ratio of usage power measured in kW to total power measured in kVA;

  • Capacity factor means the ratio of the average load on a machine or equipment for the period of time considered to the capacity rating of the machine or equipment.

  • Capacity Utilization Factor or “CUF” Shall have the same meaning as provided in CERC (Terms and Conditions for Tariff determination from Renewable Energy Sources) Regulations, 2009 as amended from time to time. Here, the CUF is expressed in AC terms.

  • Fit factor means a quantitative estimate of the fit of a particular respirator to a specific individual, and typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn.

  • Load Factor means the percentage of aircraft seats actually occupied on a flight (RPMs divided by ASMs). “NMB” means the National Mediation Board.

  • NET INVESTMENT FACTOR The net investment factor for each subaccount is determined by dividing (1) by (2) and subtracting (3) from the result, where:

  • Stress Factor means 2.25.

  • Weighting factor wT for an organ or tissue (T) means the proportion of the risk of stochastic effects resulting from irradiation of that organ or tissue to the total risk of stochastic effects when the whole body is irradiated uniformly. For calculating the effective dose equivalent, the values of wT are:

  • Interest Factor means monthly compounding, discounting or annuitizing, as applicable, at a rate set forth in Exhibit A.

  • Total Open-End Mutual Fund Average Net Assets means the average of all of the determinations of the aggregate net assets of all open-end funds sponsored by Xxxxxx Management (excluding the net assets of such funds investing in, or invested in by, other such funds, such as Xxxxxx RetirementReady® Funds and Xxxxxx Money Market Liquidity Fund, to the extent necessary to avoid "double-counting" of such net assets) at the close of business on each business day during each month while the Management Contract is in effect.

  • Leverage Factor means the leverage factor in respect of a Series of ETP Securities as specified in the relevant Final Terms.

  • Adjustment Factor means, with respect to a share of the Fund (or one unit of any other security for which a Fund Closing Price must be determined), 1.0, subject to adjustment in the event of certain events affecting the shares of the Fund. See “—Anti-dilution Adjustments Relating to the Fund; Alternate Calculation —Anti-dilution Adjustments” below.

  • Limited Indexation Factor means, in respect of a Limited Indexation Month or Limited Indexation Date, as the case may be, the ratio of the Index Figure applicable to that month or date, as the case may be, divided by the Index Figure applicable to the month or date, as the case may be, twelve months prior thereto, provided that (a) if such ratio is greater than the Maximum Indexation Factor specified in the relevant Final Terms, it shall be deemed to be equal to such Maximum Indexation Factor and (b) if such ratio is less than the Minimum Indexation Factor specified in the relevant Final Terms, it shall be deemed to be equal to such Minimum Indexation Factor;

  • Note Factor means, with respect to a Payment Date and each Class of Notes, a six-digit decimal, which the Servicer will compute each month, equal to the Note Balance of such Class of Notes as of the end of the related Collection Period divided by the Note Balance of such Class of Notes as of the Closing Date. The Note Factor will be 1.000000 as of the Closing Date; thereafter, the Note Factor will decline to reflect reductions in the Note Balance of such Class of Notes.

  • Rating Agency Discount Factor means the Fitch Discount Factor (if Fitch is then rating Preferred Shares) or an Other Rating Agency Discount Factor, whichever is applicable.

  • Loss Factor means the scaling factor determined in accordance with clause 7 and applied by the reconciliation manager to volumes of electricity measured or estimated in respect of ICPs on the Network, in order to reflect the impact of the ICP on Losses within the Network;

  • Reserve Penalty Factor means the cost, in $/MWh, associated with being unable to meet a specific reserve requirement in a Reserve Zone or Reserve Sub-zone. A Reserve Penalty Factor will be defined for each reserve requirement in a Reserve Zone or Reserve Sub-zone.

  • Additional Accelerated Purchase Share Volume Maximum means, with respect to an Additional Accelerated Purchase made pursuant to Section 2(c) hereof, a number of shares of Common Stock equal to (i) the number of Purchase Shares specified by the Company in the applicable Additional Accelerated Purchase Notice as the Additional Accelerated Purchase Share Amount to be purchased by the Investor in such Additional Accelerated Purchase, divided by (ii) the Additional Accelerated Purchase Share Percentage (to be appropriately adjusted for any reorganization, recapitalization, non-cash dividend, stock split, reverse stock split or other similar transaction).

  • Pricing Level refers to the determination of which of Level I, Level II, Level III, Level IV, Level V or Level VI applies at any date.

  • Moody’s Discount Factor means, for purposes of determining the Discounted Value of any Moody’s Eligible Asset, the percentage determined by reference to the rating on such asset and the shortest Exposure Period set forth opposite such rating that is the same length as or is longer than the Moody’s Exposure Period, in accordance with the table set forth below: Exposure Period Aaa* Aa* A* Baa* Other** (V)MIG-1*** SP-1+**** Unrated***** 7 weeks 151% 159% 166% 173% 187% 136% 148% 225% 8 weeks or less but greater than seven weeks. 154 161 168 176 190 137 149 231 9 weeks or less but greater than eight weeks 158 163 170 177 192 138 150 240 * Mxxxx’x rating. ** Municipal Obligations not rated by Moody’s but rated BBB by S&P. *** Municipal Obligations rated MIG-1 or VMIG-1, which do not mature or have a demand feature at par exercisable in 30 days and which do not have a long-term rating. **** Municipal Obligations not rated by Moody’s but rated SP-1+ by S&P, which do not mature or have a demand feature at par exercisable in 30 days and which do not have a long-term rating. ***** Municipal Obligations rated less than Baa3 or not rated by Moody’s and less than BBB or not rated by S&P, not to exceed 10% of Moody’s Eligible Assets. Notwithstanding the foregoing, (i) except as provided in clause (ii) below, the Moody’s Discount Factor for short-term Municipal Obligations will be 115%, so long as such Municipal Obligations are rated at least MIG-1, VMIG-l or P-1 by Moody’s and mature or have a demand feature at par exercisable in 30 days or less, or 125%, as long as such Municipal Obligations are rated at least A-1+/AA or SP-1+/AA by S&P and mature or have a demand feature at par exercisable in 30 days or less, (ii) the Moody’s Discount Factor for residual interest municipal bonds and structured notes shall be the product of (x) the percentage determined by reference to the rating on the security underlying such residual interest municipal bond multiplied by (y) 1.25 (provided that the trust in which such residual interest municipal bond is held may be terminated within five business days), and (iii) except as provided in clause (ii) above, no Moody’s Discount Factor will be applied to cash, Receivables for Municipal Obligations Sold, or futures, options and similar instruments (to the extent such securities are Moody’s Eligible Assets); provided, however, that for purposes of determining the Moody’s Discount Factor applicable to a Municipal Obligation, any Municipal Obligation (excluding any short-term Municipal Obligation) not rated by Moody’s but rated by S&P shall be deemed to have a Mxxxx’x rating which is one full rating category lower than its S&P rating.

  • Exchange Factor means 1.0; provided, however, that if the General Partner: (a) declares or pays a dividend on its outstanding Common Stock in Common Stock or makes a distribution to all holders of its outstanding Common Stock in Common Stock; (b) subdivides its outstanding Common Stock; or (c) combines its outstanding Common Stock into a smaller number of shares of Common Stock, the Exchange Factor shall be adjusted by multiplying the Exchange Factor by a fraction, the numerator of which shall be the number of shares of Common Stock issued and outstanding on the record date for such dividend, contribution, subdivision or combination (assuming for such purpose that such dividend, distribution, subdivision or combination has occurred as of such time), and the denominator of which shall be the actual number of shares of Common Stock (determined without the above assumption) issued and outstanding on the record date for such dividend, distribution, subdivision or combination. Any adjustment to the Exchange Factor shall become effective immediately after the effective date of such event retroactive to the record date, if any, for such event.

  • Discount Factor means the percentage discount applied to additional APCs when more than one APC is provided during the same visit (including the same APC provided more than once). Not all APCs are subject to a discount factor.

  • Pricing Level V any time when (i) the senior unsecured long term debt rating of the Borrower by (x) S&P is BBB‑ or higher or (y) Xxxxx’x is Baa3 or higher and (ii) none of Pricing Level I, Pricing Level II, Pricing Level III or Pricing Level IV applies.

  • Accelerated Purchase Share Volume Maximum means, with respect to an Accelerated Purchase made pursuant to Section 2(b) hereof, a number of shares of Common Stock equal to (i) the number of Purchase Shares specified by the Company in the applicable Accelerated Purchase Notice as the Accelerated Purchase Share Amount to be purchased by the Investor in such Accelerated Purchase, divided by (ii) the Accelerated Purchase Share Percentage (to be appropriately adjusted for any reorganization, recapitalization, non-cash dividend, stock split, reverse stock split or other similar transaction).

  • Rated Voltage means the manufacturer’s design voltage at which the transmission system is designed to operate or such lower voltage at which the line is charged, for the time being, in consultation with Transmission System Users;