Examples of Receptacle outlet in a sentence
Receptacle outlet assemblies listed for use in countertops shall be permitted to be installed in the countertop.Informational Note: See 406.5(E) and 406.5(G) for requirements for installation of receptacles in countertops.
In countertop or work surfaces: Receptacle outlet assemblies listed for use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces.
Receptacle outlet assemblies listed for the application shall be permitted to be installed in countertops.
Receptacle outlet boxes shall not be located within 6' of water sinks, except where a ground fault interrupter circuit breaker or ground fault type receptacle is provided to protect receptacle outlets located within 6' of water sinks.
Contact your Code Official for electrical code information such as:• Overhead wires and cable clearances• Wiring methods, disconnect and insulated ground wire requirements• Receptacle outlet location(s) (new & existing)• Light fixture, ceiling fan and switch location(s)• Ground fault circuit interrupter protection• Landscape lighting and wiring• Bonding requirements: pumps, metal fencing, gutters/downspouts etc.
Receptacle outlet assemblies listed for use in countertops shall be installed in the countertop.
Receptacle outlet assemblies listed for use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces.
Electric power was to be provided for a school only when electricity had previously been provided to the school or where an electric line had already been run to the school site.• Lighting fixtures: Fluorescent fixtures were planned taking maintenance and economy into consideration.• Receptacle outlet fixtures: A receptacle outlet was planned in rooms that required electric power.
Receptacle outlet assemblies listed for use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces .
Receptacle outlets shall be located in one or more of the following:(1) On or above countertop or work surfaces: On or above, but not more than 500 mm (20 in.) above, the countertop or work surface.(2) In countertop or work surfaces: Receptacle outlet assemblies listed for use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces.(3) Below countertop or works surfaces: Not more than 300 mm (12 in.) below the countertop or work surface.