Type of Meter Conventional (only available for businesses) Prepaid Time of Use Domestic 15A SP* 30A SP* 60A SP* Commercial 60A SP* 20A TP** Industrial 60A SP* 20A TP** 40A TP** 60A TP** *Single Phase (SP) **Three Phase (TP) Time of Use Three Phase NMD kVA AMP Bulk Services Fees I/We, the undersigned, do hereby apply for an electricity connection from the Municipal Supply to the above mentioned plot in terms of the Standard Electricity Supply By-Law, Overstrand Credit Policy, SANS 10142-1, NRS 047& NRS048.
Contractor to ensure connection is done according to SANS 10142-1 and 240-56227516 – LV Switchgear Control Gear Assembly Associated Equipment for Voltage 1000V AC and 1500V Standard.
Installation in accordance with SANS 10142-1, SANS 10114-1, SANS 10114-2 and SANS 10389-1 and SANS 10389-2.
For fault levels less than 10 kA, the Distribution Board (DB) shall be inspected by a trained person in accordance with SANS 10142-1; a CoC will only be issued if the assembly is free of deviations.
In Terms of the Electrical Installations Regulations (SANS 10142-1), which are a Schedule to the Occupational Health & Safety Act, an Electrical Contractor must be Registered as an Accredited Person (i.
All permanent or temporary “Electrical Installations” complies with the statutory requirements as explained in the Occupational Health and Safety Act and SANS 10142-1 for the wiring of premises which include the issuing of Certificate of Compliance before an installation is accepted by the Employer.
The Airports Company’s electrical department shall have a right of admittance to inspect and examine the electrical installation in the Premise/ and or Site so that it adheres to SANS 10142-1.
The Contractor shall design cabling to allow cable approaches accommodating cable-bending radii as per the cable manufacturer’s requirements or SANS 10142-1, whichever is greater.
All motors for the motor for the lift system shall comply with the following Employer specifications: 240-56357518 – Power station electric motors procurement 240-56360387 – Storage of Power Station electric motors standard All new equipment is earthed as per requirement of SANS 10142-1.
Type of Meter Conventional (only available for businesses) Prepaid Time of Use Domestic 15A SP* 30A SP* 60A SP* Commercial 60A SP* 20A TP** Industrial 60A SP* 20A TP** 40A TP** 60A TP** *Single Phase (SP) **Three Phase (TP) Time of Use Three Phase NMD kVA AMP Bulk Services Fees SSEG I/We, the undersigned, do hereby apply for an electricity connection from the Municipal Supply to the above mentioned plot in terms of the Electricity Supply By-Law, Overstrand Credit Policy, SANS 10142-1, NRS 047& NRS048.