USER’S MANUAL
USER’S MANUAL
AIR-CONDITIONER
ENGLISH
MANUAL DEL PROPIETARIO
ESPAN˜ OL
ACONDICIONADOR DE AIRE
MANUAL DO UTILIZADOR
PORTUGUÊS
DXK09Z5L-S DXK12Z5L-S DXK15Z5L-S
APARELHO DE AR CONDICIONADO
KULLANIM KILAVUZU TÜRKÇE
This air conditioner complies with EMC Directive 2004/108/EC, LV Directive 2006/95/EC.
Este acondicionador de aire cumple con la directiva EMC: 2004/ 108/EC, LV Directiva 2006/95/EC.
Este aparelho de ar condicionado está em conformidade com a Directiva EMC 2004/108/EC e a Directiva LV 2006/95/EC.
RLC012A007A
This air-conditioner is intended for domestic use.
Do not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas, covered by the Kyoto Protocol with a Global Warming Potential (GWP) = 1975.
ENGLISH
Your Air Conditioning product may be marked with this symbol. It means that waste electrical and electronic equipment (WEEE as in directive 2012/ 19/EU) should not be mixed with general household waste. Air conditioners should be treated at an authorized treatment facility for re-use, recycling and recovery and not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information.
This symbol printed in the batteries attached to your Air Conditioning product is information for end-users according to the EU directive 2013/56/ EU article 20 annex II.
Batteries, at their end-of-life, should be disposed of separately from general
household waste. If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the batteries contain a heavy metal at a certain concentration. This will be indicated as follows: Hg:mercury(0.0005%) , Cd:cadmium(0.002%) , Pb:lead(0.004%)
Please, dispose of batteries correctly at your local community waste collection or the recycling center.
The emission sound pressure level from each Indoor and Outdoor unit is under 70 dB(A).
contents
Safety precautions 2
Name of each part and its function 6
Remote control handling 8
Operation failure with the remote control 8
Temporary run operation 8
Operation and display section for remote control 9
Current time setting 9
AUTO mode operation 10
Temperature adjustment during AUTO 10
FAN SPEED 10
COOL/HEAT/DRY/FAN mode operation 11
Air-conditioner operable
temperature setting 11
Characteristics of HEAT mode operation 11
Airflow direction adjustment 12
SLEEP TIMER operation 13
OFF-TIMER operation 13
ON-TIMER operation 14
SLEEP TIMER + ON-TIMER operation 14
PROGRAM TIMER operation 15
HIGH POWER/ECONOMY operation 16
SELF CLEAN operation 17
Auto restart function 17
Tips for effective operation 17
Maintenance 18
Proper installation 20
Troubleshooting 20
Notice 21
Contact your dealer 22
Self diagnosis function 23
Safety precautions
• Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
• When you have read this instruction manual, please keep it without missing. If someone else takes over as operator, make certain that the manual is also passed on to the new operator.
WARNING | Improper handling could lead to drastic result like death, se- rious injury, etc. |
CAUTION | Might pose a serious problem, depending on the circum- stances. |
Please observe these precautions with great care, since they are essential to your safety.
• Symbols which appear frequently in the text have the following meaning:
Strictly prohibited | Observe instructions with great care | Provide proper earth- ing |
❚ INSTALLATION PRECAUTIONS
WARNING | |
• The system is for domestic, residential etc. use. If used in severer environments, such as an engineering workplace, the equipment may function poorly. | |
• The system must be installed by your dealer or a qualified professional. It is not advisable to install the system by yourself, as faulty handling may cause leak- age of water, electric shock or fire. |
CAUTION | |
• Do not install it where flammable gas may leak. Gas leaks may cause fire. | |
• Depending on the place of installa- • Make sure to install the drain hose tion, an earth leakage breaker may be properly so that all the water is necessary. drained out. If you do not install an earth leakage Improper installation may lead to water breaker, you may get an electric shock. drop in the room resulting in wet furni- ture. | |
• Make sure that the system has been properly earthed. Earth cables should never be connected to a gas pipe, water pipe, lightning conductor or telephone earth cable. Incorrect installation of the earth cable may produce an elec- tric shock. |
❚ OPERATION PRECAUTIONS
WARNING | |
• Children shall not play with the appli- • Cleaning and user maintenance shall ance. not be made by children without su- • Do not expose yourself to the cooling pervision. air for a long period. • Do not insert anything into the air in- This could affect your physical condition let. and cause health problems. This may cause injury, as the internal fan rotates at high speed. | |
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. • Store the remote control out of reach of infants. Failure to observe this may result in the batteries being swallowed or other accidents. |
CAUTION | |
• Only use approved fuses. • The system should only be used for Use of steel or copper wire instead of an its original purpose and not for any- approved fuse is strictly prohibited, as it thing else like, for instance, preserva- may cause a breakdown or fire. tion of food, plants or animals, preci- • Do not handle the switches with wet sion devices or works of art. hands. The system is only intended for use in This may cause an electric shock. ordinary domestic rooms. Any other use • Do not swing from the indoor unit. of the system may damage the quality If the indoor unit falls down,you may get • of food, etc. injured. Do not place anything containing wa- • Do not place a flammable insecticide ter, like vases, on top of the unit. or paint spray near the blower, nor Water entering the unit could damage spray it directly on the system. the insulation and therefore cause an This may result in a fire. • electric shock. • You should not expose any combus- Do not install the system where the tion appliance directly to the air airflow direction is aimed directly at stream of the air-conditioner. plants or animals. The appliance may then work inad- • This will damage their health. equately. Do not sit on the outdoor unit nor put • Do not wash the air-conditioner with anything on it. water. If the unit falls down or things drop off it, people could get hurt. This could cause an electric shock. • After a long period of use, check the unit's support structure from time to time. If you do not repair any damage right away, the unit may fall down and cause personal injury. |
CAUTION | |
• Do not touch the aluminum fins on the • Do not shut off the power supply im- air heat exchanger. mediately after stopping the opera- It may result in injury. tion. • Do not place household electrical Wait at least 5 minutes, otherwise there appliances or household items under is a risk of water leakage or breakdown. neath the indoor or outdoor units. • Do not control the system with main Condensation falling from the unit may power switch. stain objects and cause accidents or It can cause fire or water leakage. In electrical shock. addition, the fan can start unexpectedly, • Do not operate the system without which can cause personal injury. the air filter. • Do not pour liquid into this unit and do It can cause malfunction of the system not put water container on this unit. due to clogging of the heat exchanger. Water entering the unit could damage the insulation and therefore cause an electric shock. | |
• If you operate the system together • Contact your dealer to clean inside with a combustion appliance, you the indoor unit, do not attempt to do must regularly ventilate the indoor by yourself. air. The use of a non-approved detergent or Insufficient ventilation may cause acci- improper washing method may damage dents due to oxygen deficiency. the unit’s plastic components and cause • Stand firmly on a stepladder or other leaks. Damage, smoke, or fire may also stable object when removing the inlet happen if the detergent comes in con- panel and filters. tact with electrical parts or the unit’s Failure to observe this may result in motor. injury through insecure objects toppling • Stop the unit and turn off the power if over. you hear thunder or there is a danger • When you clean the system, stop the of lightning. unit and turn off the power supply. It may damage the unit. Never open the panel while the internal • Do not let the foreign matters enter fan is rotating. the indoor unit through the air out- • Do not place objects near the out- lets. door unit or allow leaves to gather This may cause the dumper inoperable. around the unit. • If the power cord becomes damaged, If there are objects or leaves around the contact your dealer or a qualified en- outdoor unit, small animals may enter gineer. unit and contact electrical parts and If it is not replaced, it may cause a may cause a break-down, smoke or fire. breakdown or fire. |
❚ PRECAUTIONS FOR RELOCATION OR REPAIRS
WARNING | |
• Do not perform any repairs or modifications by yourself. Consult the dealer if the unit requires repair. If you repair or modify the unit, it can cause water leaks, electric shocks or fire. | |
• Consult your dealer for repairs. • If the air-conditioner fails to cool or Wrong repairs could cause an electric warm the room, it may have a refrig- shock, fire, etc. erant leakage. Contact your dealer. • In case the air-conditioner is relo- If refrigerant needs to be added, cated elsewhere, contact your dealer check with your dealer for proper or a professional fitter. instructions. Faulty installation may cause water If the refrigerant comes in contact with leakage, electric shock, fire, etc. the bare skin, it may cause cold injury. • If you notice anything abnormal If the refrigerant gas is inhaled exces- (smell of burning, etc.), stop the sively, it may cause deterioration of nerve system, turn off the power supply function like dizziness and headache, or and consult your dealer. deterioration of heart function like irregu- Continued use of the system in abnor- lar heartbeat and heart palpitation tempo- mal circumstances may result in mal- rarily. If refrigerant unexpectedly leaks functioning, electric shock, fire, etc. from the unit onto a fan heater, stove, hotplate or other heat source, harmful gases could be generated. |
Air filter
Remove dust or dirt from the inlet air.
Page 18
Indoor unit fan
Front panel
Page 7
Room temperature sensor
Air outlet
Air blows out of here.
Left/right airflow direction adjustment louver
Page 12
Up/down airflow direction adjustment flap
Page 12
Drain hose
<Top view>
Drains water from the indoor unit.
Refrigerant piping connection and electric wire
Page 19
OUTDOOR UNIT
Unit display section
Name of each part and its function
INDOOR UNIT
Heat exchanger |
Air-cleaning filter |
Air inlet
(On side & rear surface)
Air outlet
Outdoor unit fan
Heat exchanger
Name of each part and its function
Unit display section
Remote control signal receiver
Unit ON/OFF button
This button can be used for turning on/off the unit when remote control is not available.
Page 8
RUN (HOT KEEP) light (blue)
• Illuminates during operation.
• Blinks when airflow stops due to the ‘HOT KEEP’ and ‘CLEAN operation’.
HOT KEEP
ON OFF
1.5 sec.
0.5 sec.
CLEAN operation
ON OFF
3 sec.
Page 17
1 sec.
TIMER light (yellow)
Illuminates during TIMER operation.
Wireless remote control Wireless remote
control holder
Battery
(R03 (AAA, Micro) x2)
Wood screw (Quantity:2)
(for remote control holder mounting)
Natural enzyme filter (Green)
Installing
1. Remove the air filter.
2. Remove the filter holders, with the air-cleaning filter installed in the holders, from the air filter.
3. Install the air-cleaning filter in the filter holders, and then install the filter holders in the air filter.
Photocatalytic washable deodorizing filter (Orange)
4. Install the air filter.
Page 18, 19
NOTE
• Buzzer sound for remote control
When preset temperature 24°C, automatic operation and automatic airflow are selected, the buzzer sound (PiPi) is produced. When turning off the air conditioner by pressing ON/OFF button (except CLEAN mode), the buzzer sound (Pi) is produced. This function is useful for operating the air conditioner in the darkness.
Air flow setting Preset temperature
Remote control handling
Replacing the batteries
The following cases signify exhausted batteries. Replace old batteries with new ones.
• Receiving beep is not emitted when a signal is transmitted.
NOTE
• Do not use old and new batteries together.
• Remove the batteries when the remote control is not used for a long period.
• The recommended effective period of a battery conforming to JIS or IEC should be 6 to 12 months with normal use. If used longer, or when an unspecified battery is used, liquid may leak from the battery, causing the remote control to malfunction.
• The recommended effective period is printed on the battery. This may be shorter due to manufacturering time to the unit. However, the battery may still be in working order after expiry of its nominal life.
1 Pull out the cover and take out old batteries. |
2 Insert new batteries. R03 (AAA, Micro) x2 Pay attention to the ª and · marks |
3 Close the cover. |
4 Press the ACL switch with the tip of a ballpoint pen. The timer setting mode is displayed. Page 9 |
• Display fades away.
■ When the display shows any abnormal condition, Press the ACL switch with the tip of a ballpoint pen.
Using the remote control holder
The remote control can be attached to a wall or pillar by using a remote control holder. Before installing the remote control, check that the air-conditioner receives the signals properly.
For installing or removing the remote control, move it up or down in the holder.
Warning note for remote control handling
Strictly prohibited | ||
• Do not go near high temperature places, such as an electric carpet or stove. | • Do not leave the remote control ex- posed to direct sunlight or other strong lighting. | • Do not drop the remote control. Handle with care. |
• Do not put any obstructing obsta- cles between the remote control and the unit. | • Do not spill any liquid on the remote control. | • Do not place heavy objects on the remote control, or step on it. |
Operation failure with the remote control
• Are the batteries running down?
“Replacing the batteries” above.
• If the operation fails, operate the unit with temporary operation function.
Contact your dealer to have the remote control
Below
Replace the batteries with new ones and retry the operation. checked.
Temporary run operation
• The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
• OPERATION MODE : AUTO
• FAN SPEED : AUTO
• AIR FLOW : AUTO
• Operation starts by pressing the unit ON/OFF button; it stops if you press the button again.
NOTE
Unit ON/OFF button
• Do not hold the Unit ON/OFF button down for more than 5 seconds.
(Holding it down longer than 5 seconds sets the automatic cooling used during servicing or when relocating the air-conditioner.)
Operation and display section for remote control
Operation section
FAN SPEED button
Each time the button is pressed, the display is switched over in turn.
Page 10
HI POWER/ECONO button
This button changes the HIGH POWER/ ECONOMY mode.
Page 16
TEMPERATURE button
These buttons set the room temperature. (These buttons are used for setting the current time and timer function as well.)
OPERATION MODE select button
Each time the button pressed, the display is switched over in turn.
Page 10, 11
ON/OFF (luminous) button
Press to start operation, press again to stop.
AIR FLOW (UP/DOWN) button
This button changes the air flow (up/down) direction.
Page 12
ON TIMER button
This button selects ON TIMER operation.
Page 14
SLEEP button
This button selects SLEEP operation.
Page 13
CLEAN switch
This switch selects the CLEAN mode.
Page 17
CANCEL button
This button cancels the ON timer, OFF timer, and SLEEP operation.
• The above illustration shows all controls, but in practice only the relevant parts are shown.
OFF TIMER button
This button selects OFF TIMER operation.
Page 13
ACL switch
This switch is for resetting microcomputer and setting time. Page 8
Transmission procedure
When each button on the remote control is pressed – with the remote control pointing towards the air-conditioner unit a signal is transmitted. When the air-conditioner receives the signal correctly, it will beep.
Current time setting
■ When inserting the batteries, the current time is automatically set to time setting mode. 13:00 is displayed as the current time. Set the clock to the right time.
NOTE
• The timer operation works based on the time clock, so please set it correctly.
• The remote control data is reset when the present time is set.
1
2
Press the ACL switch.
Press with the tip of a ballpoint pen, etc.
The time display blinks and can be set to the current time.
Press the or button.
(Set to 10:30)
3
Press the ON/OFF button.
The display changes from blinking to steady lighting and the setting is complete. Make sure to press the button within 60 seconds from the last operation in step 2, otherwise the time is not set.
Example: Set to 10:30.
■ Automatically selects the operation mode (COOL, HEAT, DRY) depending on the room temperature when switched on.
1
Press MODE button.
Move the [ mark] to the (Auto) position.
When the unit is not in AUTO mode:
To stop:
Press the ON/OFF button.
2
Press the ON/OFF button.
Point the remote control toward the air-conditioner, and
NOTE
• In case air is not blowing out during the operation.
Page 21
Display in OFF status
• The current time and preset OPERA- TION MODE are displayed while the air conditioner is turned off.
• If you do not want the AUTO mode program, change to COOL, HEAT, DRY or FAN instead of AUTO.
Page 11
• Airflow direction adjustment procedure.
Page 12
Temperature adjustment during AUTO
When a change in temperature is required.
1
Press the or button.
When it is a little cold
■ Each time the button is pressed, the switch over occurs in the following order
–6 → –5 → ............ –1 → ±0 → +1 ............ +6.
When +6 is indicated, even if the button is pressed, the indicator does not change.
When it is a little hot
■ Each time the button is pressed, the switch over occurs in the following order
+6 → +5 → ............ +1 → ±0 → –1 ............ –6.
When –6 is indicated, even if the button is pressed, the indicator does not change.
Press the button.
Press the button.
■ Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the button or the button. During automatic operation, 24°C is preset both for heating and cooling.
Remote Control display | |||||||||||||
Setting temp.(°C) | -6 | -5 | -4 | -3 | -2 | -1 | +0 | +1 | +2 | +3 | +4 | +5 | +6 |
18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 |
FAN SPEED
■ You can choose the capacity of your air-conditioner when heating mode, cooling mode or fan mode.
Press the FAN SPEED button.
Move the [ mark] to the preferred fan speed position.
AUTO
HI
MED
LO
NOTE
• When changing FAN SPEED from HI to LO, the sound of refrigerant flowing may be heard.
Operation capacity by your choice | FAN SPEED |
Set automatically by microcomputer | AUTO |
Powerful operation with high capacity | HI |
Standard operation | MED |
Energy-saving operation | LO |
1
Press the MODE select button.
Move the [ mark] to the required operation position.
(Cool), (Heat), (Dry), (Fan)
Point the remote control toward the air-conditioner, and
2
3
Press the ON/OFF button.
Press the TEMP button.
Press or button for the preferred temperature.
Recommendation
4
Press the FAN SPEED button
Set the fan speed as preferred.
To stop:
Press the ON/OFF button.
Airflow direction adjustment procedure. Page 12
NOTE
Air-conditioner operable temperature setting
■ Use within the following operational range. Operating outside of this range may result in the protection devices being activated, preventing the unit from working.
Cooling operation | Heating operation | |
Outside temperature | Approximately -15 °C to 46 °C | Approximately -15 to 24 °C |
Inside temperature | Approximately 18 to 32 °C | Approximately 15 to 30 °C |
Inside humidity | Below approximately 80% The long-term use of the unit with a humidity level exceeding 80% may result in condensation forming on the surface of the indoor unit, leading to water drips. | — |
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
■ Mechanism
• The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the heating capacity reduces when the outside air temperature gets colder.
• It may take some time to supply hot air after turning on the air-conditioner.
• If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defrost function is activated and during defrosting the heating operation stops for 5 to 15 minutes during defrosting.
• Both indoor and outdoor fans stop and the RUN light blinks slowly (1.5 sec. ON, 0.5 sec. OFF) during defrosting.
• The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
• The HEAT operation resumes as soon as defrosting has been completed.
Adjusting airflow direction
■ Up/down direction can be adjusted with the AIRFLOW button on the remote control. Every time you press this button the mode changes as follows:
Change on AIRFLOW (UP/DOWN) mode.
(Flap stopped) (Swing)
NOTE FOR HEATING OPERATION
• When operation starts, the flap direction is fixed at the horizontal position in order to avoid cold draft, and return to the set the position that was set after the warm air supply is starting.
• The flap direction will be controlled to the horizontal position when the room temperature reaches the set temperature and compressor stops or when defrosting is in operation.
• The airflow direction cannot be set during the period mentioned above. Change the airflow direction settings after the warm air is supplied and the
flap goes to the set position.
(Horizontal blowing)
COOL, DRY
(Slant forward blowing)
HEAT
MEMORY FLAP (FLAP STOPPED)
When you press the AIRFLOW button once while the flap is operating, it stops swinging at the position. Since this angle is memorized in the microcomputer, the flap will automatically be set at this angle when the next operation is started.
WARNING
• Do not expose directly to airflow from the air-conditioner for a long time.
• Recommended angle of the flap when stopping
CAUTION
• When in COOL or DRY operation, do not operate for a long period with the airflow blowing straight down. Otherwise, condensation may appear on the outlet grill and drip down.
• Do not try to adjust the flaps by hand, as the control angle may change or the flap may not be closed completely.
Adjusting left/right air flow direction
■ Adjust the direction by moving the left/right louver by hand.
When you adjust the direction, touch the operation point of louver.
Operation point
Louver
Flap
CAUTION
• Please stop the air conditioner when adjusting the air flow direction.
■ The unit stops automatically after the set time lapses.
The set temperature is automatically adjusted according to the elapsed time in order to avoid too much cooling or heating. Page 15
1 Press the SLEEP button.
■ If it is pressed while the unit is off
SLEEP TIMER operation starts with the previous operation settings, and the air conditioning is turned off after the set time elapses.
■ If it is pressed while the unit is running
The air conditioner is turned off after the set time elapses.
Every time the button is pressed, the display changes as follows:
... (Units of one hour)
No indication (canceled)
Example: You prefer it to stop after 7 hours.
Set to
The timer light (yellow) is on.
h
Changing of set time
Set a new time by pressing SLEEP button.
• The unit stops after the set time lapses.
How to cancel
Press the CANCEL button to turn off the SLEEP display.
NOTE
• Cannot be set at the same time with OFF-TIMER.
OFF-TIMER operation
■ The unit stops automatically when the set time comes.
With the air conditioner turned off, start the operation from Step 1. With the air conditioner running, start from Step 2.
Example: You prefer it to stop 22:30.
1
2
3
Press the ON/OFF button.
Press the OFF TIMER button.
OFF TIMER display is blinking.
Press the
Every time the 0:00 0:10
or button.
button is pressed, the display is switched in the order of:
0:20
... 1:00
1:10 (Units of ten minutes)
Every time the button is pressed, the display is switched in the order of: 0:00 23:50 23:40 ... 23:00 22:50 (Units of ten minutes)
Set at 22:30.
4
Press the OFF TIMER button.
The display changes from blinking to steady lighting and the setting is complete. The timer light (yellow) is on.
How to cancel
Press the CANCEL button to turn off the timer display.
Changing of set time
Set a new time by using the OFF TIMER button.
NOTE
• The unit stops at the end of the set period of time.
• Make sure to press the button within 60 seconds from the last operation in step 3, otherwise the setting is not completed.
• The current time is not displayed during OFF-TIMER operation.
• Different from SLEEP TIMER operation, automatic set temperature adjust- ment is not done during OFF-TIMER operation.
■ Operation starts 5 to 60 minutes before the set time so that the room temperature reaches the optimum temperature at the set time. Page 15 ON-TIMER operation can be set regardless of whether the air-conditioner is running or not.
Example: In the case the preferred room temperature is required at 8:00.
1
Press the ON-TIMER button.
ON TIMER display is blinking.
2
Press the
or button.
Every time the
0:00 0:10
button is pressed, the display is switched in the order of:
0:20
... 1:00
1:10 (Units of ten minutes)
Every time the button is pressed, the display is switched in the order of: 0:00 23:50 23:40 ... 23:00 22:50 (Units of ten minutes)
Set at 8:00.
3
Press the ON TIMER button.
The display changes from blinking to steady lighting and the setting is com- plete.
The timer light (yellow) is on.
The operation stops if it is set during operation.
NOTE
• Operation starts 5 to 60 minutes before the set time.
• The timer light (yellow) goes out at the set time.
• Make sure to press the button within 60 seconds from the last operation in step 2, otherwise the setting is not completed.
• The current time is not displayed during ON-TIMER operation.
How to cancel
Press the CANCEL button to turn off the timer display.
Changing of set time
Set a new time by using the ON-TIMER button.
SLEEP TIMER + ON-TIMER operation
■ Combined timer operation of SLEEP TIMER and ON TIMER.
Example: When it is required to stop after 3 hours and then start operation at 8:00, near the set temperature.
■ SLEEP TIMER setting
Set by the procedures on page 13. Set to
■ ON TIMER operation setting
Set by the above procedure mentioned in ON TIMER. Set to
The setting of the lighting of the timer light (yellow) of this unit is complete.
h
• After the SLEEP TIMER set time has elapsed, the operation stops, and it starts from 5 to 60 minutes before the ON TIMER’s set time.
• The timer light is turned off when ON TIMER set time comes.
Changing of set time
Set a new time by using the SLEEP or ON TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
■ The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the same time every day unless the ON/OFF button is pressed.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the set temperature.
■ OFF TIMER operation setting
Set by the procedures on page 13. Set to
■ ON TIMER operation setting
Set by the procedures on page 14. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will change depending on the operational status.
With ON TIMER, the air conditioner starts running. Then, with OFF TIMER, the air conditioner stops running.
With OFF TIMER, the air conditioner stops running. Then, with ON TIMER, the air conditioner starts running.
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
SLEEP TIMER
When SLEEP TIMER is selected, the set temperature is automatically adjusted after a while, ensuring that the room is not too cold during cooling or too warm during heating.
• During cooling : The preset temperature is lowered by 1°C at the start of SLEEP operation (when the timer is set). After that, the tem- perature goes up by 1°C every an hour to become 1°C higher than the present temperature.
• During heating: The preset temperature is lowered by 1°C at the start of SLEEP operation (when the timer is set). After that the tem- perature becomes 3°C lower in an hour and 6°C lower in two hours than the present temperature.
Comfort Start-up
In ON TIMER operation, the unit starts the operation a little earlier, so that the room can approach optimum temperature at ON time. This is so called “Comfort start-up”.
• Mechanism
▼
▼
The room temperature is
checked 60 minutes before the ON time. Depending on the temperature at that time, the operation starts 5 to 60 minutes before the timer is at ON.
• The function is available for both COOL and HEAT operation mode (including AUTO). It does
In COOL operation (Stop) Operation starts
(Operation)
Set temperature
not work for DRY mode.
Check the room
temp. 60 mins. before.
Set time
If the air-conditioner is not operating, point the remote control toward the air conditioner, and
1
2
Press the ON/OFF button.
Press the HI POWER/ECONO button.
• When the operating mode is AUTO, COOL or HEAT
Every time the HI POWER/ECONO button is pressed, the display is switched in the order of:
No display
(HIGH POWER) (ECONOMY) (Normal operation)
• When the operating mode is DRY or PROGRAM TIMER
Every time the HI POWER/ECONO button is pressed, the display is switched in the order of:
(ECONOMY)
No display
(Normal operation)
Concerning HIGH POWER operation
Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling or heating operation for 15 minutes continuously. The remote control displays and the FAN SPEED display disappears.
NOTE
• During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling or heating, press the HI POWER/ECONO button again to cancel the HIGH POWER operation.
• HIGH POWER operation is not available during the DRY and the program timer operations.
• When HIGH POWER operation is set after ON TIMER operation, HIGH POWER operation will start from the set time.
• When the following operations are set, HIGH POWER operation will be canceled.
1 When the HI POWER/ECONO button is pressed again.
2 When the operation mode is changed.
3 When it has been 15 min. since HIGH POWER operation has started.
• Not operable while the air conditioner is OFF.
Concerning ECONOMY operation
Pressing the HI POWER/ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates 1.5°C higher than the setting temperature during cooling or 2.5°C lower than that during heating. The remote control displays and the FAN SPEED display disappears.
NOTE
• It will go into ECONOMY operation at the next time the air- conditioner runs in the following case.
1 When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
2 When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
3 When the operation is retrieved from CLEAN operation.
• When the following operations are set, ECONOMY operation will be canceled.
1 When the HI POWER/ECONO button is pressed again.
2 When the operation mode is changed from DRY to FAN.
• Not operable while the air conditioner is OFF.
■ CLEAN operation should be run after AUTO, COOL and DRY operation to remove the moisture from inside the indoor unit and control the growth of mold and bacteria.
1
In order to active CLEAN operation, press the CLEAN switch with the tip of a ballpoint pen.
Every time the CLEAN switch is pressed, the display is switched in the order of:
No display
(CLEAN on) (CLEAN off)
NOTE
• Two hours later, the air conditioner stops running automatically. To stop the air conditioner immediately, press the ON/OFF button.
• CLEAN operation is not operated after HEAT, FAN, OFF-TIMER and SLEEP operations have finished.
• The indoor unit fan runs for about two hours in CLEAN operation.
• The RUN light illuminates during CLEAN operation.
3 sec.
ON
OFF
1 sec.
• Pressing the SLEEP button during CLEAN operation cancels the CLEAN operation and then the unit is set to SLEEP operation.
• This is not a function for removing mold, germs or grime that have al- ready adhered to the unit.
Auto restart function
■ What is auto restart function?
• Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then automatically resumes operations after the power has been restored.
• The following settings will be canceled:
1 Timer settings
2 HIGH POWER operations
NOTE
• Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to be switched off.
• When power failure occurs, the timer setting is canceled. Once power is resumed, set the timer again.
Tips for effective operation
■ Please observe the following for the most economic and comfortable use of your unit.
Set a suitable room temperature. Excessively high or low temperatures are not good for your health and waste of electricity. | Clean the filter frequently. Clogged filter may block the airflow and cause less efficient operation. | Avoid direct sunlight and draught. Cut out direct sunlight by drawing the cur- tains or blinds when cooling. Keep windows and doors shut, except when ventilating. |
Adjust the airflow direction properly. Adjust the up/down and left/right airflow to ensure a steady room temperature. | Operate the unit only when needed. Use the timer properly to operate the unit only when needed. | Keep heat source away when cooling. Keep heat sources out of the room as much as possible. |
Careful matter during maintenance
Turn off the power supply.
• Do not spill any liquid.
Wipe the unit with a soft, dry cloth.
There's a danger of electric shock.
Do not use the following articles:
• Hot water (40°C or more)
It may deform or discolour the unit.
• Petrol, paint thinner, benzine or cleanser, etc. They may deform or scratch the unit.
• Do not touch the aluminum fins on the heat exchanger.
• Stand firmly on a stepladder or other stable object when removing the filter.
During the operational season
1 Cleaning the air filter Recommendation interval is once every two week • Hook fingers on this side of the top face of air filter. Pull the air filter forward. The air filter will separate from front panel. CAUTION • When removing the air filter, pull it out gently without tilting and with care not to shake off dirt accumulated on the air filter. • Be careful not to allow dirt shaken off the air filter entering in the eyes or mouth. |
2 Cleaning Remove dirt from the air filter using a vacuum cleaner. If the filter is very dirty, clean it with warm water (approx. 30°C), and dry it thoroughly. CAUTION • Do not clean the filter with boiling water. • Do not dry them over an open flame. • Pull them out gently. |
3 Reinstall the air filter • Insert the air filter's ditch to the rail of the front panel and push it in the back. Rail (both side) CAUTION • Operating without putting back the air filter will Ditch (both side) make the unit dusty, and may cause damage. |
Cleaning the unit • Wipe the unit with a soft, dry cloth, or use a vacuum cleaner. • If the unit is very dirty, wipe it with a cloth soaked in warm water. |
NOTE
Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It may also use extra electricity. Please clean the air filter at recommendation intervals.
At the end of the season |
At the beginning of the season |
1 Perform the fan operation for a half day. Dry the inside of the unit. Cooling season only. |
2 Stop the unit and turn off the power supply. The unit consumes approx. 2W even when the unit is not operat- ing. Turning off the power supply will help saving energy con- sumption and cost. |
3 Clean and reinstall the air filter. |
4 Clean both the indoor and outdoor units. |
5 Remove batteries from the remote control. |
1 | Make sure that there are no obstacles block- ing the airflow around the air intake and outlet openings of the indoor and outdoor units. |
2 | Check if there is no corrosion or rust on the base frame of the outdoor unit. |
3 | Ensure that the earth wiring is not snapped nor disconnected. |
4 | Ensure that the air filter are clean. |
5 | Turn on the power supply. |
6 | Insert batteries in the remote control. |
Installing, inspecting and replacing the air-cleaning filter
1. Remove the air filter. Page 18
2. Remove the filter holders, with the air-cleaning filter installed in the holders, from the air filter.
3. Remove the photocatalytic washable deodorizing filter (orange) from the filter holder and inspect the filter. Periodically, remove any dust or dirt from the photocatalytic washable deodorizing filter. If the photocatalytic washable deodorizing filter is par- ticularly dirty, it may be washed with water. However, the filter is fragile so be sure to wash it installed in the filter holder to avoid damaging it. After washing the filter, place it in sunlight to dry. Placing the filter in sunlight revitalizes the deodorizing effect.
Remove the natural enzyme filter (green) from the filter holder and inspect the filter. Use a vacuum cleaner to remove any dust or dirt from the natural enzyme filter. Replace the natural enzyme filter if it cannot be cleaned or if it has been used for about 1 year.
(The natural enzyme filter should be replaced after about 1 year of use. However, the actual replacement period may vary depending on the conditions in which the filter is used.)
(Do not dispose of the filter holders. They are reused. )
4. Install the air-cleaning filter in the filter holders, and then install the filter holders in the air filter.
Filter holder
Air filter
Air-cleaning filter
NOTE Filter holder
• The natural enzyme filter and the photocatalytic washable deodor- izing filter may be installed on either the right or left side of the air filter.
• Place the natural enzyme filter with the green side upper.
5. Install the air filter. Page 18
CAUTION
• Do not expose natural enzyme filters to direct sunlight for an extended period. The bac- teriolytic effect will be lost.
For replacement the air-cleaning filter, contact your dealer.
Item | Feature | Color |
Photocatalytic washable deodorizing filter | Sources of odors on the filter are broken up, resulting in a deodorizing effect. | Orange |
Natural enzyme filter | By using the work of enzyme, mold and bacteria on the filter are destroyed and the room air is kept clean. | Green |
Suitable installation position
• Do not put any obstruction in front of the indoor unit, preventing proper ventilation and functioning.
• Do not install the unit in any of the following places:
• Where there is a danger of leaking flammable gases.
• Where there is substantial splashing of oil.
• Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated, or in a seaside resort exposed to sea breezes. Contact your dealer.
• The air-conditioner and remote control must be at least 1 metre away from a TV set or radio.
• Drain the dehumidified liquid from the indoor unit into a spot that drains well.
Pay attention to operating noises!
• When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the operating noise or vibration. If vibration is transmitted through the house, fix the unit with the aid of vibration-proof pads between the unit and the fittings.
• Select a place where cold or hot air, operation noises from the indoor and outdoor units do not cause any inconvenience to your neighbours.
• Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.
• If you hear an irregular noise during operation, contact your dealer.
Inspection and maintenance
Depending on operating environment, the inside of the air-conditioner may become dirty after a few year operations. This will reduce performance. In addition to normal cleaning, we would recommend inspection and maintenance. (This may lead the air-conditioner to having a longer life without any trouble.)
• Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).
• We would recommend inspection and maintenance to be carried out during the off-season.
• If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special purpose tools are required.
Troubleshooting
Please carry out the following checks before making a service call.
The air-conditioner does not work at all. | ||
Has the power switch been turned off? | Has the timer been set in the “ON” position? | Is there a power failure or a blown fuse? |
Poor cooling or heating | ||
Have you set the thermostat at a suitable temperature? | Is the air filter clean? (Not clogged?) | Did you leave any doors or windows open? |
Poor cooling | ||
Is there any direct sunlight entering the room? | Is there a heat source in the room? | Are there too many people in the room? |
If the air-conditioner does not operate properly after you have checked the above points, or if any doubt still exists after you have consulted page 21, or if things happen as shown on page 22, switch off the power and contact your dealer.
An alternative refrigerant (R410A) is used in this air-conditioner. When asking your dealer for service or inspection and maintenance, explain the dealer about it.
The unit does not restart immediately after you have stopped it. (RUN light is on) | Restart is blocked for 3 minutes after you have stopped the op- eration to protect the unit. The three-minute protection timer in the microcomputer auto- matically starts it up again. |
Airflow is not blown out when starting the HEATING opera- tion. RUN light blinks slowly (1.5 sec ON, 0.5 sec OFF) | Airflow has stopped to prevent blowing out of cold air until the indoor heat exchanger has warmed up. (2 to 5 min.) (HOT KEEP program) |
Airflow is not blown out for 5 to 15 min. or blown out not warm wind for a moment at HEATING operation. RUN light blinks slowly (1.5 sec ON, 0.5 sec OFF) | When outdoor temperature is low and humidity is high, the unit sometimes performs defrosting automatically. Please wait. Dur- ing defrosting, water or steam may escape from the outdoor unit. |
Airflow is not blown out when starting the DRY operation. (RUN light is on) | The indoor fan may stop to prevent re-evaporation of dehumified moisture and to save energy. |
Some steam escapes during COOL operation. | This may occur if the room's temperature and humidity are very high. It disappears as soon as the temperature and humidity decrease. |
There is a slight smell. | Air blown out during operation may smell. This is caused by tobacco or cosmetics adhering to the unit. |
You hear a slight gurgling sound. | This is caused by refrigerating liquid moving within the unit. |
You hear a slight cracking sound. | This is caused by heat expansion or contraction. |
You hear a hissing or clicking sound. | This is caused by the operation of the refrigerant control valves or electric components. |
After a power cut, the unit does not restart even if power has been restored. | If the auto restart function is not set, the unit will not restart auto- matically. Use the remote control to start the operation again. |
Remote control signals are not received. | Remote control signals may not be received if the signal receiver on the air-conditioner is exposed to direct sunlight or other bright light. If so, cut out the sunlight or reduce the other light. |
Moisture may form on the air outlet grills. | If the unit is operated for a long time in high humidity, moisture may form on the air outlet grills and start dripping. |
Whistling noise is heard from the outdoor unit. | The noise means that the revolution speed of the compressor is increasing or decreasing. |
Fan will not stop immediately after unit operation was stopped. | Indoor fan : Fan will not stop after 2 hours if set to CLEAN operation. Outdoor fan : Fan will not stop about a 1 minute period in order to protect the unit. |
RUN light stays on even though operation was stopped. | The RUN light illuminates during CLEAN operation. Run light turns off when CLEAN operation ends. |
■ Turn off the power switch immediately and inform your dealer in any of the following situations:
The cable becomes extremely hot. CAUTION The covering of the cable is cracked. If the power cord becomes damaged, ask your dealer or a qualified engineer to install the replacement to avoid accidents. | |
The fuse or switch blows continuously. | The TV, radio or other equipment starts to malfunction. |
A switch does not activate properly. | You hear a strange noise during operation. |
When abnormalities occur, turn off the power supply imme- diately and turn it on after 3 minutes. Restart the operation with ON/OFF button of the remote control and the abnor- malities still continue. | The RUN and TIMER lights on the unit display section blink quickly (0.5 sec. ON; 0.5 sec. OFF) and do not work. |
TIMER light
RUN light
■ We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows:
Description of trouble | Cause | ||||
Heat exchanger sensor error | • Broken heat exchanger sensor wire, poor connector connection | ||||
1-time flash | |||||
Room temperature sensor error | • Broken room temperature sensor wire, poor connector connection | ||||
2-time flash | |||||
TIMER light ON | |||||
Active filter voltage error | • Defective power supply | ||||
5-time flash | |||||
Indoor fan motor error | • Defective fan motor, poor connector connection | ||||
6-time flash | |||||
Outdoor temperature sensor error | • Broken outdoor sensor wire, poor connector connection | |||||
1-time flash | ||||||
Outdoor heat exchanger fluid pipe sensor error | • Broken heat exchanger fluid pipe sensor wire, poor connector connection | |||||
RUN light keeps flashing | ||||||
2-time flash | ||||||
Discharge pipe sensor error | • Broken discharge pipe sensor wire, poor connector connection. | |||||
4-time flash | ||||||
Current cut | • Compressor locking, open phase on compressor output, shortcircuit on power transistor, closed service valve | |||||
1-time flash | ||||||
Trouble of outdoor unit | • Broken power transistor, broken compressor wire • Broken discharge pipe sensor wire, poor connector connection • Compressor blockage | |||||
2-time flash | ||||||
Over current | • Overload operation, overcharge | |||||
3-time flash | ||||||
Power transistor error | • Broken power transistor | |||||
4-time flash | ||||||
RUN light ON | ||||||
Over heat of compressor | • Gas shortage, defective discharge pipe sensor, closed service valve | |||||
5-time flash | ||||||
Error of signal transmission | • Defective power supply, Broken signal wire, defective in/outdoor unit boards | |||||
6-time flash | ||||||
Outdoor fan motor error | • Defective fan motor, poor connector connection | |||||
7-time flash | ||||||
Cooling high pressure protection | • Gas over charge, short circuit of outdoor unit | |||||
Keep flashing | ||||||
2-time flash
• Defective compressor
• Open phase on compressor
• Defective outdoor unit boards
Rotor lock
RUN light 2 time flash
AIR-CONDITIONING & REFRIGERATION DIVISION
3-1, Xxxxx, Nishibiwajima-cho, Kiyosu, Aichi, 452-8561, Japan xxxx://xxx.xxx.xx.xx
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.
0 Xxxxxxxxx Xxxxxx, Xxxxxxxx Xxxx, Xxxxxxxx, Xxxxxxxxx, XX00 0XX, Xxxxxx Xxxxxxx Tel : x00-00-0000-0000
Fax: x00-00-0000-0000
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONERS AUSTRALIA, PTY. LTD.
0X Xxxxxxxxxx Xxxx Xxxxxxxxxx XXX 0000 PO BOX 318 Kingsgrove NSW 1480 Tel : x00-0-0000-0000
Fax: x00-0-0000-0000