Building Structural System Clause Samples
Building Structural System. In addition to the code required loads, the following shall be provided: Design Loads: Typical floor loads80 lb Live Load 100 lb Total Load Mechanical rooms125 psfor actual load Typical roof loads20 lb Live Load Above loads are to be reducible as allowed by applicable building code. The building shall be a minimum 5" thick, 4,000psi concrete and conform to +/- 1 1/4” in 10’. The proposed Building slabs are on a podium and will be structural slabs with post-tensioning. The building superstructure will be concrete frame. Floor to floor height must allow adequate space for ten-foot (10’0”) ceiling heights and above ceiling MEP work each floor. The first floor shall have a floor to floor height of twenty-one (21’0”) feet to allow for a fifteen (15’0”) lobby ceiling.
