Company Interim Tank Permitted Feedstock Payment Sample Clauses

Company Interim Tank Permitted Feedstock Payment. For each day, Macquarie shall calculate a provisional payment (each a “Company Interim Tank Permitted Feedstock Payment”) by applying the
AutoNDA by SimpleDocs

Related to Company Interim Tank Permitted Feedstock Payment

  • Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)

  • Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Lightyear’s loop distribution elements onto BellSouth's feeder system.

  • Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.

  • Unbundled Copper Loops (UCL) 2.4.1 BellSouth shall make available Unbundled Copper Loops (UCLs). The UCL is a copper twisted pair Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters) and is not intended to support any particular telecommunications service. The UCL will be offered in two types – Designed and Non-Designed.

  • Shared Transport The Shared Transport Network Element (“Shared Transport”) provides the collective interoffice transmission facilities shared by various Carriers (including Qwest) between end-office switches and between end-office switches and local tandem switches within the Local Calling Area. Shared Transport uses the existing routing tables resident in Qwest switches to carry the End User Customer’s originating and terminating local/extended area service interoffice Local traffic on the Qwest interoffice message trunk network. CLEC traffic will be carried on the same transmission facilities between end- office switches, between end-office switches and tandem switches and between tandem switches on the same network facilities that Qwest uses for its own traffic. Shared Transport does not include use of tandem switches or transport between tandem switches and end-office switches for Local Calls that originate from end users served by non- Qwest Telecommunications Carriers (“Carrier(s)”) which terminate to QLSP End Users.

  • Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.

  • ADJUSTMENT OF THE DISTRIBUTOR’S ALLOCABLE PORTION AND EACH SUCCESSOR DISTRIBUTOR’S ALLOCABLE PORTION The parties to the Distribution Agreement recognize that, if the terms of any distributor’s contract, any distribution plan, any prospectus, the FINRA Conduct Rules or any other applicable law change so as to disproportionately reduce, in a manner inconsistent with the intent of this Distribution Agreement, the amount of the Distributor’s Allocable Portion or any Successor Distributor’s Allocable Portion had no such change occurred, the definitions of the Distributor’s Allocable Portion and/or the Successor Distributor’s Allocable Portion in respect of the Class C shares relating to a Fund shall be adjusted by agreement among the relevant parties; provided, however, if the Distributor, the Successor Distributor and the Fund cannot agree within thirty (30) days after the date of any such change in applicable laws or in any distributor’s contract, distribution plan, prospectus or the FINRA Conduct Rules, they shall submit the question to arbitration in accordance with the commercial arbitration rules of the American Arbitration Association and the decision reached by the arbitrator shall be final and binding on each of them. The following relates solely to Class 529-C shares. The Distributor’s Allocable Portion of Distribution Fees and CDSCs in respect of Class 529-C shares shall be 100% until such time as the Distributor shall cease to serve as exclusive distributor of Class 529-C shares; thereafter, collections that constitute CDSCs and Distribution Fees relating to Class 529-C shares shall be allocated among the Distributor and any successor distributor (“Successor Distributor”) in accordance with this Schedule. At such time as the Distributor’s Allocable Portion of the Distribution Fees equals zero, the Successor Distributor shall become the Distributor for purposes of this Allocation Schedule. Defined terms used in this Schedule and not otherwise defined herein shall have the meanings assigned to them in the Principal Underwriting Agreement (the “Distribution Agreement”), of which this Schedule is a part. As used herein the following terms shall have the meanings indicated:

  • Unbundled Sub-Loop Distribution Voice Grade (USLD-VG) is a copper sub- loop facility from the cross-box in the field up to and including the point of demarcation at the End User’s premises and may have load coils.

  • After Acquired Real Property (i) Upon the acquisition by any Loan Party after the date hereof of any fee interest in any real property (wherever located) (each such interest being a “New Facility”) with a Current Value (as defined below) in excess of $1,000,000, promptly so notify the Collateral Agent, setting forth with specificity a description of the interest acquired, the location of the real property, any structures or improvements thereon and either an appraisal or such Loan Party’s good-faith estimate of the current value of such real property (for purposes of this Section, the “Current Value”). The Collateral Agent shall notify such Loan Party whether it intends to require a Mortgage and the other Real Property Deliverables. Upon receipt of such notice requesting a Mortgage, the Person that has acquired such New Facility shall promptly furnish to the Collateral Agent each of the applicable Real Property Deliverables, reasonably requested by the Collateral Agent. The Borrowers shall pay all fees and expenses, including reasonable attorneys’ fees and expenses, and all title insurance charges and premiums, in connection with each Loan Party’s obligations under this Section 7.01(o). (ii) Notwithstanding the foregoing, the Administrative Agent shall not enter into any Mortgage in respect of any improved real property acquired by any Loan Party after the Closing Date until (1) (a) if such improved real property is not located in a “special flood hazard area”, the date that is five (5) Business Days or (b) if such improved real property is located in a “special flood hazard area”, the date that occurs 14 days after the Administrative Agent has delivered to the Lenders (which may be delivered electronically) the following documents in respect of such real property: (i) a completed flood hazard determination from a third party vendor; (ii) if such real property is located in a “special flood hazard area”, (A) a notification to the applicable Loan Party of that fact and (if applicable) notification to the applicable Loan Party that flood insurance coverage is not available and (B) evidence of the receipt by the applicable Loan Party of such notice; and (iii) if such notice is required to be provided to the applicable Loan Party and flood insurance is available in the community in which such real property is located, evidence of required flood insurance.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!