Cost of Water Treatment Sample Clauses

Cost of Water Treatment. JCSA may receive Treated Water by paying to City, City’s cost of treatment at metered system interconnections, with the Cost of Treatment being $0.70 per 1,000 gallons of water. Beginning July 1, 2009, cost of Treated Water will be increased annually based upon the procedures defined in Article
AutoNDA by SimpleDocs

Related to Cost of Water Treatment

  • Future Treatment of Unallowable Costs Unallowable Costs shall be separately determined and accounted for by Defendants, and Defendants shall not charge such Unallowable Costs directly or indirectly to any contracts with the United States or any State Medicaid program, or seek payment for such Unallowable Costs through any cost report, cost statement, information statement, or payment request submitted by Defendants or any of their subsidiaries or affiliates to the Medicare, Medicaid, TRICARE, or FEHBP Programs.

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Surface Treatments The Project Area is covered by a layer of mulch permeable to air and water, including, but not limited to rock, bark, ungrouted stepping stones and artificial turf manufactured to be permeable or a high- density planting of living groundcover plants. There are no impermeable barriers that would inhibit the passage of air and/or water to the soil. APN: 161-06-701-001 When Recorded, Return To: Southern Nevada Water Authority Conservation Division P.O. Box 99956 MS 110 Las Vegas, Nevada 89193-9956 EXHIBIT “D” CONSERVATION EASEMENT This Grant of Conservation Easement (“Easement”) is made by the Xxxxx County School District, a political subdivision of the State of Nevada, as the grantor, (“Owner”) and the Southern Nevada Water Authority (“Authority”), a political subdivision of the State of Nevada, as the holder.

  • Network Congestion Reduced Speed for Routing or Answering 911 Dialing Calls. There may be a greater possibility of network congestion and/or reduced speed in the routing of a 911 Dialing call made utilizing the Service as compared to traditional 911 dialing over traditional public telephone networks.

  • TOOL STORAGE 1. A company shall provide on all construction jobs in towns and cities, and elsewhere where reasonably necessary and practicable (or if requested buy the employee), a suitable and secure waterproof lock-up solely for the purpose of storing employees’ tools, and on multi-storey and major projects the company shall provide, where possible, a suitable lock-up for employees’ tools within a reasonable distance of the work area of large groups of employees.

  • Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.

  • Meter Testing Company shall provide at least twenty-four (24) hours' notice to Seller prior to any test it may perform on the revenue meters or metering equipment. Seller shall have the right to have a representative present during each such test. Seller may request, and Company shall perform, if requested, tests in addition to the every fifth-year test and Seller shall pay the cost of such tests. Company may, in its sole discretion, perform tests in addition to the fifth year test and Company shall pay the cost of such tests. If any of the revenue meters or metering equipment is found to be inaccurate at any time, as determined by testing in accordance with this Section 10.2 (Meter Testing), Company shall promptly cause such equipment to be made accurate, and the period of inaccuracy, as well as an estimate for correct meter readings, shall be determined in accordance with Section 10.3 (Corrections).

  • Overcrowding The number of people who may live in a Let Property depends on the number and size of the rooms, and the age, gender and relationships of the people. Living rooms and bedrooms are counted as rooms, but not the kitchen or bathroom. The Tenant must not allow the Let Property to become overcrowded. If the Let Property does become overcrowded, the Landlord can take action to evict the Tenant as the Tenant has breached this term of this Agreement.

  • Required Coverages For Generation Resources Of 20 Megawatts Or Less Each Constructing Entity shall maintain the types of insurance as described in section 11.1 paragraphs (a) through (e) above in an amount sufficient to insure against all reasonably foreseeable direct liabilities given the size and nature of the generating equipment being interconnected, the interconnection itself, and the characteristics of the system to which the interconnection is made. Additional insurance may be required by the Interconnection Customer, as a function of owning and operating a Generating Facility. All insurance shall be procured from insurance companies rated “A-,” VII or better by AM Best and authorized to do business in a state or states in which the Interconnection Facilities are located. Failure to maintain required insurance shall be a Breach of the Interconnection Construction Service Agreement.

  • Medical Treatment Undersigned understands that the Released Parties do not have medical personnel available at the location of the activities. Undersigned hereby grants the Released Parties permission to administer first aid or to authorize emergency medical treatment, if necessary. Undersigned understands and agrees that any such action by the Released Parties shall be subject to the terms of this agreement and release, including any liability arising from the negligence of the Released Parties when administering first aid or authorizing others to do so. Undersigned understands and agrees that the Released Parties do not assume responsibility for any injury or damage which might arise out of or in connection with such authorized emergency medical treatment.

Time is Money Join Law Insider Premium to draft better contracts faster.