Cutblock Adjacency & Patch Size Distribution Sample Clauses

Cutblock Adjacency & Patch Size Distribution. ‌ The draft TSR4 information package states that adjacency will be modeled in an aspatial manner using the characteristics in Table 40. However, specifically modeling cutblock adjacency is not current practice within the Lakes TSA. The licensees have moved to using seral and patch size targets to create an acceptable patch size distribution on the THLB, reducing the level of fragmentation on the landscape. The licensees monitor and assess patch size distribution as part of their certification and/or Sustainable Forest Plan (SFMP) requirements every year. Table 40. Cutblock Adjacency Constraint MaximuZone or allowab Group disturban area) mle Green-up height ce (% (metres) Land base to which constraints apply Cutblock 33% Adjacency 3 THLB The patch size distributions used for this project are listed in Table 41. The patch size distribution criteria were taken from the Lakes South SRMP. Table 41. Desired Patch Distribution from Lakes South SRMP Natural Disturbance Type BEC Subzone Small Patch Medium Patch Large Patch 2 ESSF mc <40 ha 40 – 80 ha >80 ha 30 – 40% 30 – 40% 20 – 40% SBS dk <40 ha 40 – 250 ha >250 ha SBSmc 10 – 30% 10 – 30% 40 – 80% 3 The seral stage definitions used for assessing patches are provided in Table 42. Table 42. Seral Classes for Patch Definition BEC zone Early Immature Mid Mature + Old ESSF <=20 >20 and <=40 >40 and <=120 >120 SBS <=20 >20 and <=40 >40 and <=100 >100
AutoNDA by SimpleDocs
Cutblock Adjacency & Patch Size Distribution. ‌ The TSR3 information package states that adjacency will be modeled in an aspatial manner using the characteristics in Table 46. However, specifically modeling cutblock adjacency is not current practice within the Xxxxxx TSA. The licensees have moved to using seral and patch size targets to create an acceptable patch size distribution on the THLB, reducing the level of fragmentation on the landscape. The licensees monitor and assess patch size distribution as part of their certification and/or Sustainable Forest Plan (SFMP) requirements every year.

Related to Cutblock Adjacency & Patch Size Distribution

  • Unbundled Sub-Loop Distribution Intrabuilding Network Cable (USLD-INC) is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross connect device in the building equipment room up to and including the point of demarcation at the End User’s premises.

  • When Must Distributions from a Traditional IRA Begin You must begin receiving the assets in your account no later than April 1 following the calendar year in which you reach RMD age.

  • Unbundled Subloop Distribution (USLD) 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from an End User’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))

  • Coronavirus-Related Distributions (CRDs If you qualify, you may withdraw up to $100,000 in aggregate from your IRAs and eligible retirement plans as a CRD, without paying the 10 percent early distribution penalty tax. You are a qualified individual if you (or your spouse or dependent) is diagnosed with the COVID-19 disease or the SARS-CoV-2 virus in an approved test; or if you have experienced adverse financial consequences as a result of being quarantined, being furloughed or laid off or having work hours reduced due to such virus or disease, being unable to work due to lack of child care due to such virus or disease, closing or reduced hours of a business owned or operated by you due to such virus or disease, or other factors as determined by the IRS. A CRD must be made on or after January 1, 2020, and before December 31, 2020. CRDs will be taxed ratably over a three-year period, unless you elect otherwise, and may be repaid over three years beginning with the day following the day a CRD is made. Repayments may be made to an eligible retirement plan or IRA. An eligible retirement plan is defined as a qualified retirement plan, 403(a) annuity, 403(b) tax-sheltered annuity, 457(b) eligible governmental deferred compensation plan, or an IRA. FINANCIAL DISCLOSURE

  • Commingling of Resold Services with Unbundled Network Elements and Combinations of Unbundled Network Elements 6.7.1 To the extent it is Technically Feasible and pursuant to the terms of Section 9.1, CLEC may Commingle Telecommunications Services purchased on a resale basis with an Unbundled Network Element or combination of Unbundled Network Elements.

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • DISTRIBUTION OF CONTRACTOR PRICE LIST AND CONTRACT APPENDICES Contractor shall provide Authorized Users with electronic copies of the Contract, including price lists and Appendices, upon request. OGS CENTRALIZED CONTRACT MODIFICATIONS Contract Updates will be handled as provided in Appendix C – Contract Modification Procedures.

  • Traditional IRA-to-Xxxx XXX Conversions If you convert to a Xxxx XXX, the amount of the conversion from your Traditional IRA to your Xxxx XXX will be treated as a distribution for income tax purposes, and is includible in your gross income (except for any nondeductible contributions). Although the conversion amount generally is included in income, the 10 percent early distribution penalty tax will not apply to conversions from a Traditional IRA to a Xxxx XXX, regardless of whether you qualify for any exceptions to the 10 percent penalty tax. If you are required to take a required minimum distribution for the year, you must remove your required minimum distribution before converting your Traditional IRA.

  • Unbundled Voice Loop – SL2 (UVL-SL2 Loops may be 2-wire or 4-wire circuits, shall have remote access test points, and will be designed with a DLR provided to NewPhone. SL2 circuits can be provisioned with loop start, ground start or reverse battery signaling. OC is provided as a standard feature on XX0 Xxxxx. The OC feature will allow NewPhone to coordinate the installation of the Loop with the disconnect of an existing customer’s service and/or number portability service. In these cases, BellSouth will perform the order conversion with standard order coordination at its discretion during normal work hours.

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!