Common use of Datasheets Clause in Contracts

Datasheets. Installation specifications • Discipline design criteria documents • Supporting calculations • Design proposal drawings • System descriptions to support committed system design This scope does not include the layout and routing of C&I instrumentation cable, incorporation of vendor information, programming of software, or physicalization typically associated with confirmation activities. 3EP10EJCMP PT - C&I Engineering Complete 3EP17HT003 PT - C&I SFS - C1V System Rev 0 (100%) 3EP17C1FNJ PT- C&I – SBD FNJ 3EP17SR0FM PT-C&I SSRS Rev 0 Completion 3EP17C1SUM PT-C&I-EIT Report SUM Ref. original ID# 3EPZZEJGM • At the time of completion, BNI will transmit a list of the drawing numbers to the DOE Federal Project Manager for the drawing type codes listed: - J1 - system block diagram - 3PS - safety system requirements specification - M6 - piping and instrument diagrams (control data from software functional specifications will be incorporated into piping and instrumentation diagrams) Facility PTF Activity ID 1GP47CFM06 Description Receipt of all Plant Service Air System Pipe Racks Receive and accept all PSA system pipe racks at the Marshalling Yard, to include the following: PSA-RK-00018 PSA-RK-00028 PSA-RK-00014 PSA-RK-00003 PSA-RK-00037 PSA-RK-00020 PSA-RK-00033 PSA-RK-00016 PSA-RK-00005 PSA-RK-00039 PSA-RK-00021 PSA-RK-00035 PSA-RK-00023 PSA-RK-00006 PSA-RK-00052 PSA-RK-00022 PSA-RK-00036 PSA-RK-00024 PSA-RK-00008 PSA-RK-00053 PSA-RK-00031 PSA-RK-00047 PSA-RK-00027 PSA-RK-00009 PSA-RK-00054 PSA-RK-00032 PSA-RK-00048 PSA-RK-00038 PSA-RK-00010 PSA-RK-00055 PSA-RK-00025 PSA-RK-00049 PSA-RK-00001 PSA-RK-00011 PSA-RK-00056 PSA-RK-00026 PSA-RK-00050 PSA-RK-00002 PSA-RK-00012 N/A N/A Inclusions Exclusions Activity ID Description Activity ID Description PT QC/MRR – Release 1 – 56+ PT-MY QC&MRR-Release 4 – 9ZP47257B1 Racks – Rooms 311/322 Q- 9ZP47257E1 77+ Racks-Rooms MA-PH02-08 415/423/423A Q-MA-PH02-03 9ZP47257C1 PT-MY QC&MRR-Release 6 – 77+ Rooms 431 A/B 422A/402 Q-MA-PH02-06 9ZP47257G1 PT-MY QC&MRR-Release 3 – 77+ Racks – Rooms 426/410/425 Q-MA-PH02-12 9ZP47257D1 PT-MY QC&MRR-Release 5 – 77+ Racks-Rooms 423A/B Q- MA-PH02-04 9ZP47257H1 PT-MY QC&MRR-Release 2 – 77+ Racks-Room 410 Q-MA- PH02-11 Ref. original ID# 9FP472093X • Completion of this milestone will include a screen shot from the Bechtel Procurement System demonstrating that the material receiving report number has been issued for the specific shipment and the material receiving report has been completed and issued by Project Document Control. Facility PTF Activity ID 1GPZZCFM07 Description Electrical Design Complete Complete the Pretreatment electrical design. All deliverables mentioned are for the committed stage of design and include the supporting calculations and evaluations: • Single line diagrams • Cable tray and raceway drawings • Cable and wire routing • Schematics • Lighting drawings • Grounding drawings • Cathodic protection design • Lightning protection drawings • Communications layout drawings • Material requisitions for quote • Equipment specifications

Appears in 4 contracts

Samples: List of Attachments, List of Attachments, List of Attachments

AutoNDA by SimpleDocs

Datasheets. Installation specifications • Discipline design criteria documents • Supporting calculations • Design proposal drawings • System descriptions to support committed system design This scope does not include the layout and routing of C&I instrumentation cable, incorporation of vendor information, programming of software, or physicalization typically associated with confirmation activities. 3EP10EJCMP PT - C&I Engineering Complete 3EP17HT003 PT - C&I SFS - C1V System Rev 0 (100%) 3EP17C1FNJ PT- C&I – SBD FNJ 3EP17SR0FM PT-C&I SSRS Rev 0 Completion 3EP17C1SUM PT-C&I-EIT Report SUM Ref. original ID# 3EPZZEJGM • At the time of completion, BNI will transmit a list of the drawing numbers to the DOE Federal Project Manager for the drawing type codes listed: - J1 - system block diagram - 3PS - safety system requirements specification - M6 - piping and instrument diagrams (control data from software functional specifications will be incorporated into piping and instrumentation diagrams) Facility PTF Activity ID 1GP47CFM06 Description Receipt of all Plant Service Air System Pipe Racks Receive and accept all PSA system pipe racks at the Marshalling Yard, to include the following: PSA-RK-00018 PSA-RK-00028 PSA-RK-00014 PSA-RK-00003 PSA-RK-00037 PSA-RK-00020 PSA-RK-00033 PSA-RK-00016 PSA-RK-00005 PSA-RK-00039 PSA-RK-00021 PSA-RK-00035 PSA-RK-00023 PSA-RK-00006 PSA-RK-00052 PSA-RK-00022 PSA-RK-00036 PSA-RK-00024 PSA-RK-00008 PSA-RK-00053 PSA-RK-00031 PSA-RK-00047 PSA-RK-00027 PSA-RK-00009 PSA-RK-00054 PSA-RK-00032 PSA-RK-00048 PSA-RK-00038 PSA-RK-00010 PSA-RK-00055 PSA-RK-00025 PSA-RK-00049 PSA-RK-00001 PSA-RK-00011 PSA-RK-00056 PSA-RK-00026 PSA-RK-00050 PSA-RK-00002 PSA-RK-00012 N/A N/A Inclusions Exclusions Activity ID Description Activity ID Description 9ZP47257B1 PT QC/MRR – Release 1 – 56+ Racks – Rooms 311/322 Q- MA-PH02-08 9ZP47257E1 PT-MY QC&MRR-Release 4 – 9ZP47257B1 Racks – Rooms 311/322 Q- 9ZP47257E1 77+ Racks-Rooms MA-PH02-08 415/423/423A Q-MA-PH02-03 9ZP47257C1 PT-MY QC&MRR-Release 6 – 77+ Rooms 431 A/B 422A/402 Q-MA-PH02-06 9ZP47257G1 PT-MY QC&MRR-Release 3 – 77+ Racks – Rooms 426/410/425 Q-MA-PH02-12 9ZP47257D1 PT-MY QC&MRR-Release 5 – 77+ Racks-Rooms 423A/B Q- MA-PH02-04 9ZP47257H1 PT-MY QC&MRR-Release 2 – 77+ Racks-Room 410 Q-MA- PH02-11 Ref. original ID# 9FP472093X • Completion of this milestone will include a screen shot from the Bechtel Procurement System demonstrating that the material receiving report number has been issued for the specific shipment and the material receiving report has been completed and issued by Project Document Control. Facility PTF Activity ID 1GPZZCFM07 Description Electrical Design Complete Complete the Pretreatment electrical design. All deliverables mentioned are for the committed stage of design and include the supporting calculations and evaluations: • Single line diagrams • Cable tray and raceway drawings • Cable and wire routing • Schematics • Lighting drawings • Grounding drawings • Cathodic protection design • Lightning protection drawings • Communications layout drawings • Material requisitions for quote • Equipment specifications

Appears in 1 contract

Samples: List of Attachments

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!