DESIGN CONCEPT (STYLING) AND CONSTRUCTION FOR THE FIREFIGHTING GLOVES Sample Clauses

DESIGN CONCEPT (STYLING) AND CONSTRUCTION FOR THE FIREFIGHTING GLOVES. The element shall meet or exceed both the design and performance requirements as outlined in NFPA 1971. The gloves shall be of a two dimensional Xxxx cut design, featuring a wing thumb, and elasticized back gather at the wrist crease. The gloves shall be of a two dimensional Xxxx cut design, featuring a wing thumb, Palm Strap for added cut resistance and elasticized back gather at the wrist crease. The gloves shall be of a wristlet style construction with the composite of the glove body extending at least 2.0 inches (5.0 cm) beyond the wrist crease. There shall be a minimum 3.5 inch (8.9 cm) double layer Nomex knit wrist sewn into the cuff opening. Provide a 2.5 inch (6.4 cm) long pull tab lock stitched to the underside of the wristlet, beginning at the wristlet seam the tab shall be approximately 3.0 inches (7.6 cm) wide and taper to 2.0 inches (5.0 cm) before it is rounded off nearest the wristlet opening. The gloves shall feature a hanger loop on the inside of the glove, made of outer shell material, stitched to the glove at the inside cuff.
AutoNDA by SimpleDocs

Related to DESIGN CONCEPT (STYLING) AND CONSTRUCTION FOR THE FIREFIGHTING GLOVES

  • Joint Network Implementation and Grooming Process Upon request of either Party, the Parties shall jointly develop an implementation and grooming process (the “Joint Grooming Process” or “Joint Process”) which may define and detail, inter alia:

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

  • BUILDER’S RISK FOR NEW CONSTRUCTION PROJECTS If the project is NEW CONSTRUCTION, then the following provisions apply:

  • Innovative Scheduling Schedules which are inconsistent with the Collective Agreement provisions may be developed in order to improve quality of working life, support continuity of resident care, ensure adequate staffing resources, and support cost-efficiency. The parties agree that such innovative schedules may be determined locally by the Home and the Union subject to the following principles:

  • Completion of Concrete Pours and Emergency Work 24.14.1 Except as provided in this sub-clause an employee shall not work or be required to work in the rain.

  • Participating TO's Interconnection Facilities Construction The Participating TO's Interconnection Facilities shall be designed and constructed in accordance with Good Utility Practice. Upon request, within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Participating TO and Interconnection Customer agree on another mutually acceptable deadline, the Participating TO shall deliver to the Interconnection Customer and the CAISO the following “as-built” drawings, information and documents for the Participating TO's Interconnection Facilities [include appropriate drawings and relay diagrams]. The Participating TO will obtain control for operating and maintenance purposes of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades upon completion of such facilities. Pursuant to Article 5.2, the CAISO will obtain Operational Control of the Stand Alone Network Upgrades prior to the Commercial Operation Date.

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • Design Criteria and Standards All PROJECTS/SERVICES shall be performed in accordance with instructions, criteria and standards set forth by the DIRECTOR.

Time is Money Join Law Insider Premium to draft better contracts faster.