Common use of ELECTRONICS AND PROTECTIONS Clause in Contracts

ELECTRONICS AND PROTECTIONS.  Maximum Power Point Tracker (MPPT) should be included to optimally use the Solar panel and maximize the water discharge.  Inverter could be used, if required, to operate an A.C. Pump. The inverter must have IP 54 protection or must be housed in a cabinet having at least IP54 protection.  Controller for BLDC motor driven pumps, if required be used. The controller must have IP 54 protection or must be housed in a cabinet having at least IP 54 protection.  Adequate protections should be incorporated against dry operation of motor Solar Pumpset System(s), lightning, hails and storms.  Full protection against open circuit, accidental short circuit and reverse polarity should be provided.

Appears in 5 contracts

Samples: Agreement, Agreement, Agreement

AutoNDA by SimpleDocs

ELECTRONICS AND PROTECTIONS. Maximum Power Point Tracker (MPPT) should be included to optimally use the Solar panel and maximize the water discharge. Inverter could be used, if required, to operate an A.C. Pump. The inverter must have IP 54 protection or must be housed in a cabinet having at least IP54 protection. Controller for BLDC motor driven pumps, if required be used. The controller must have IP 54 protection or must be housed in a cabinet having at least IP 54 protection. Adequate protections should be incorporated against dry operation of motor Solar Pumpset System(s), lightning, hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided.