Expected Performance Sample Clauses

Expected Performance. The Contractor estimates the PV system EEP as summarized in the table below. Year EEP (kWh) EESC (kWh) XXXX Capacity Guarantee (kWh) 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
AutoNDA by SimpleDocs
Expected Performance. The Licensee estimates the PV system EEP as summarized in the table below. Year EEP (kWh) EESC (kWh) XXXX Capacity Guarantee (kWh) 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 The Lease executed on or about __________ between the Judicial Council and Licensee is incorporated herein by reference.
Expected Performance. Each Party herein agrees to perform all acts and execute and deliver all documents as may be necessary or appropriate to carry out the intent and purposes of this Agreement. Recipient agrees that Discloser may not have an adequate remedy at law for money damages in the event that this Agreement has not been performed in accordance with its terms, and therefore agrees that Discloser shall be entitled to specific enforcement of the terms hereof in addition to any other remedy to which it may be entitled, at law or in equity.
Expected Performance. Improved status for Aboriginal people:
Expected Performance. Matters caused by usage patterns or traffic that exceeds the Service procured by Customer.
Expected Performance. The Doctoral Candidate will leverage all his/her knowledge skills to effectively conduct the research towards the obtainment of his/her Doctoral Degree.
Expected Performance. The estimated cool down time of the detector cryostat from room temperature to 4 K is approximately 6-8 hours. The 3He-3He-4He fridge will take approximately 70 minutes to bring the temperature of the detector to 0.255 K. The frequency coverage of the 0.3 K bolometric detector will be 2 to ~100 cm-1, determined by the combination of the low pass filter on the 77 K shield and optional bandpass filter on the detector feedhorn. The low-pass filter rejects thermal IR and reduces loading on the 4 K and 0.3 K stages. The expected cutoff frequency for the detector is ~100 Hz which is sufficient for FTS modulation frequencies in the spectral region between 2 cm-1 and 40 cm-1. The typical NEP of the bolometer element is ~5×10-16 W/Hz, enabled by the low thermal conductivity of the bolometer element and carefully designed fully differential detector, preamplifier and data acquisition electronics [12]. Pump out time ~3 hrs. Cool down time from 300 to 4 K 6-8 hrs. (estimated) Cool down time from 4 K to 0.3 K 70 min. (estimated) 0.3 K fridge recycling time ~90 min. Warmup time < 8 hrs. Cooling capacity at 4.2 K 0.25 W Cooling capacity at 0.3 K 4 µW Thermometry channels 17 Thermometry accuracy ~0.2% Detector NEP ~5×10-16 W/Hz Filter bandpass 2 to 40 cm-1 2.3 Large test facility cryostat design
AutoNDA by SimpleDocs
Expected Performance 

Related to Expected Performance

  • Excused Performance 6.1 Notwithstanding the occurrence of a Force Majeure Event, in which case Clause 17 will govern, BT will not be liable for any failure or delay to perform any of its obligations under this Agreement (including any of its obligations to meet any Service Levels) to the extent that BT’s failure or delay in performing arises as a result of: 6.1.1 any failure or delay by the Customer to perform any of the Customer’s obligations under this Agreement; 6.1.2 any act or omission other than on the part of a BT Affiliate or a subcontractor or supplier appointed by it unless that BT Affiliate, subcontractor or supplier has invoked their force majeure rights under their contract with BT; or 6.1.3 Applicable Law, a court order, an application for interlocutory relief or injunction restricting or preventing BT from supplying a Service.

  • TIMELY PERFORMANCE (a) SELLER's timely performance is a critical element of this Contract. (b) SELLER shall provide LOCKHEED XXXXXX status of performance of this Contract when requested. In addition, if SELLER becomes aware of an impending labor dispute involving SELLER or any lower tier subcontractor, or any other difficulty in performing the Work, SELLER shall timely notify LOCKHEED XXXXXX, in writing, giving pertinent details. These notifications shall not change any delivery schedule.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!