MEASURING EQUIPMENT 1. Seller will maintain and operate, atlts own, expense and atthe point of delivery of gas hereunder, a meter or meters and othernecessary equipment by which the volume of gas delivered hereunder shall be measured. Such meters and equipment shall remain the property of the Seller. 2. Buyer agrees lo furnish to Seller electricity for operating Seller's meters, at not cost to Seller. 3. Buyer hereby grants to Seller suitable rlghts-0f-way and easements necessary or Incidental for the installatioo, maintenance, operation and removal of pipeline and other facilities together with rights ofingress thereto and egress there from at all times and hereby agrees to deliver to Seller, for the sum of one dollar ($1.00), an appropriate instrument or grant defining such rights and easements located on Buyer's planlslte. 4. Buyer may install, maintain and operate such check measuring equipment, Including arecording gravltometer and calorimeter as it shall desire, provided that such equipment shall be so installed so as not to Interfere with the operation of Seller's measuring equipment at or near the point of deliver. However, all xxxxxxxx to the Buyer shall be based on the metering of the Seller, subject only to the provisions of Paragraph 8 of this Article. 5. Each party shall have the right to be present at the time of any installing, reading, cleaning, changing, repairing, Inspecting, testing, calibrating, or adjusting done In connection with the other's measuring equlpme!lt used in measuring deliveries hereunder and each party shall advise the other of any Intended major maintenance operation sufficiently in advance in order that the other party may conveniently have its representative present. 6. All installatioo of measuring equipmenL applying to or effecting deliveries hereunder, shall be rnade in such manner as to perrnit an accurate detenninalion of the quantity of gas delivered and ready verification of the accuracy of measurement Orifice meter Installations, If used, shall oonforrn lo the recommendation for design and lnstallatioo contained in the Gas Measurement Commiltee Report No. 3 to the American Gas Association published April, 1955, and any modificatioos and amendments thereof and shall include the use of flange connections. 7. Measurement on Seller's meter or meters shall be conclusive of both parties except where the meter Is defective or fails to register, or if found in E)rror, in either of which case Seller shall repair or replace the meter and the quantity of gas delivered while the meter was out of order or failed to register shall be estimated: (a) By using the registration of any check meter If installed and accurately registering, or, In the absence of (a): (b) By correcting the error If the percentage of error by calibration, test or mathematical calculation, or, in the absence of both (a) and (b) then: (c) By estimating the quantity of delivery from deliveries during periods under similar oonditions when the meter was registering actUrately; and an appropriate billing adjusbnentshall be made In accordance with the current Rules and Regulations governing gas systems issued by the Commission. 8. Seller will maintain its meters in .good order and to this end Wiii make periodic tests of its meters pursuant to the current Rules and Regulations governing gas systems issued by the Commission, or at such shorter intervals as seem to Seller desirable. lfBuyer Is dissatisfied with the accuracy at eny time, it may call upon Seller to have Iha meter tested in accordance with all regulatioos relating to such tests and results of such tesls as found in the current Rules and Regulations governing gas systems issued by the Commission. 9. Each party shall preserve all records for aperiod of at least two (2) years.
Final Working Drawings Tenant shall supply the Engineers with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements for the Premises, to enable the Engineers and the Architect to complete the “Final Working Drawings” (as that term is defined below) in the manner as set forth below. Tenant shall cause the approved Final Space Plan to be converted by the Architect and the Engineers to complete architectural and engineering drawings for the Premises, and Architect shall compile a fully coordinated set of architectural, structural, mechanical, electrical and plumbing working drawings in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Final Working Drawings”) and shall submit the same to Landlord for Landlord’s approval. Tenant shall supply Landlord with four (4) copies signed by Tenant of such Final Working Drawings. Landlord shall advise Tenant within five (5) business days after Landlord’s receipt of the Final Working Drawings for the Premises if the same is unsatisfactory or incomplete in any respect. If Tenant is so advised, Tenant shall immediately revise the Final Working Drawings in accordance with such review and any disapproval of Landlord in connection therewith. Landlord and Tenant acknowledge that the Final Space Plans may not depict certain structural elements of the Building and/or various elements of the Building systems which may result in material modifications to the Final Working Drawings (“Space Plan Modifications”) Furthermore, the Final Space Plans for the construction of the Tenant Improvements may require modification to account for the requirements of building codes and other legal requirements of applicable governmental entities, including, but not limited to, Title 24 and the Americans with Disabilities Act (collectively the “Building Codes”). The Final Working Drawings shall materially conform to the Final Space Plans, taking into account (i) Space Plan Modifications, (ii) the requirements of the Building Codes, (iii) other modifications resulting from physical constraints of the Premises and (iv) modifications requested by Tenant and consented to by Landlord, which consent shall not be unreasonably withheld. Tenant agrees that, in addition to other factors and considerations Landlord may take into account, it shall not be unreasonable for Landlord to withhold its consent to any matters set forth in the Final Working Drawings and not contained in the Final Space Plans, (i) if such requested modifications would not comply with the Building Codes or any laws, (ii) subject to Section 7 if such requested modifications would cause the anticipated cost of the Tenant Improvements to exceed the Tenant Improvement Allowance (unless Tenant agrees to be responsible for all such costs, and provide evidence satisfactory to Landlord of Tenant’s ability to pay such amounts, including escrow the funds if required by Landlord), (iii) if such requested modifications would not increase the value of the Tenant Improvements, (iv) if such requested modifications would increase the burden on the Building systems, either during construction or after completion of same.
Metering Equipment 13.01. Utility will furnish, install, own and maintain metering equipment capable of measuring the flow of kilowatt-hours (kWh) of energy. The Customer's service associated with the CRG will be metered at a single metering point. The metering equipment will measure energy delivered by Utility to Customer and also measure energy delivered by Customer to Utility. Customer agrees to provide safe and reasonable access to the premises for installation of this equipment and its future maintenance or removal.
Note to Design Professional Please insert the number of additional Days allowed and the new Material Completion and Occupancy Date, or, if no additional time is allowed, insert “0” for the Days and “No Change” for the date.
Compliance Control Services (1) Support reporting to regulatory bodies and support financial statement preparation by making the Fund's accounting records available to the Trust, the Securities and Exchange Commission (the “SEC”), and the independent accountants. (2) Maintain accounting records according to the 1940 Act and regulations provided thereunder. (3) Perform its duties hereunder in compliance with all applicable laws and regulations and provide any sub-certifications reasonably requested by the Trust in connection with any certification required of the Trust pursuant to the Xxxxxxxx-Xxxxx Act of 2002 (the “SOX Act”) or any rules or regulations promulgated by the SEC thereunder, provided the same shall not be deemed to change USBFS’s standard of care as set forth herein. (4) Cooperate with the Trust’s independent accountants and take all reasonable action in the performance of its obligations under this Agreement to ensure that the necessary information is made available to such accountants for the expression of their opinion on the Fund’s financial statements without any qualification as to the scope of their examination.
Testing of Metering Equipment Connecting Transmission Owner shall inspect and test all of its Metering Equipment upon installation and at least once every two (2) years thereafter. If requested to do so by NYISO or Developer, Connecting Transmission Owner shall, at Developer’s expense, inspect or test Metering Equipment more frequently than every two (2) years. Connecting Transmission Owner shall give reasonable notice of the time when any inspection or test shall take place, and Developer and NYISO may have representatives present at the test or inspection. If at any time Metering Equipment is found to be inaccurate or defective, it shall be adjusted, repaired or replaced at Developer’s expense, in order to provide accurate metering, unless the inaccuracy or defect is due to Connecting Transmission Owner’s failure to maintain, then Connecting Transmission Owner shall pay. If Metering Equipment fails to register, or if the measurement made by Metering Equipment during a test varies by more than two percent from the measurement made by the standard meter used in the test, Connecting Transmission Owner shall adjust the measurements by correcting all measurements for the period during which Metering Equipment was in error by using Developer’s check meters, if installed. If no such check meters are installed or if the period cannot be reasonably ascertained, the adjustment shall be for the period immediately preceding the test of the Metering Equipment equal to one-half the time from the date of the last previous test of the Metering Equipment. The NYISO shall reserve the right to review all associated metering equipment installation on the Developer’s or Connecting Transmission Owner’s property at any time.
Security Coordinator Provider shall provide the name and contact information of Provider’s Security Coordinator for the Student Data received pursuant to the DPA.
Equipment Installation In order to meet its obligations under this Agreement, a Party that owns, rents, or leases equipment (the equipment owner) may require installation of such equipment on property owned by another Party (the property owner), provided that the property is being used for an electric utility purpose and that the property owner shall not be required to do so if it would thereby be prevented from performing its own obligations or exercising its rights under this Agreement.
Project Managers The JBE’s project manager is: [Insert name]. The JBE may change its project manager at any time upon notice to Contractor without need for an amendment to this Agreement. Contractor’s project manager is: [Insert name]. Subject to written approval by the JBE, Contractor may change its project manager without need for an amendment to this Agreement.
Contract for Professional Services of Physicians Optometrists, and Registered Nurses