Fuel Gas Flow Measurements Sample Clauses

Fuel Gas Flow Measurements. The Plant fuel gas flow measurements will be based on the permanent Plant orifice flow meter. The meter is a Vixxxxx-Xxxxx xunior flow metering tube (or equal) with straightening vanes manufactured and installed in accordance with [14]. Signals of static pressure, temperature, and square root of differential pressure are sent to the DCS. The determination of fuel gas flow for the performance test will be based on manual calculations using the raw pressure, temperature, and differential pressure measurements in accordance with [12], [13], [14], [17], and/or [18] as appropriate, and in conjunction with the actual fuel gas analysis. In addition to the pressure, temperature, and differential pressure at the orifice plate, the DCS also receives inputs from the Transco and/or SONAT online gas chromatograph. Outputs from the chromatograph to the DCS include constituent analysis, heating value, and specific gravity. Volumetric flow at standard conditions is calculated directly in the DCS using orifice data and chromatograph data in Exhibit 4.2-15 conjunction with Baxxxx xlgorithms. This calculated flow will serve as a secondary measurement for the performance test. Also secondary data, fuel gas flow measurements for each Combustion Turbine will be collected via the GE supplied permanent orifice flow meters on the fuel gas supply line to each Combustion Turbine and each HRSG. Actual readings of differential pressure, static pressure, and temperature will be collected from the associated permanent Plant instruments. Fuel gas mass flow will be calculated in accordance with [12], [13], [14], [17], and/or [18] as appropriate, and in conjunction with the actual fuel gas analysis.
AutoNDA by SimpleDocs

Related to Fuel Gas Flow Measurements

  • Liquidity Risk Measurement Services Not Applicable.

  • Measurement All quantities of Products received or delivered by or into truck, rail, or marine vessel shall be measured and determined based upon the meter readings at each Terminal, as reflected by delivery tickets or bills of lading, or if such meters are unavailable, by applicable calibration tables. All quantities of Products received and delivered by pipeline shall be measured and determined based upon the meter readings of the pipeline operator, as reflected by delivery tickets, or if such meters are unavailable, by applicable calibration tables. Deliveries to a Terminal rack at Mandan, Salt Lake City or Wilmington from a Tesoro Refinery shall be deemed to be the same as the corresponding volumes delivered contemporaneously from the Terminal rack. Deliveries by book transfer shall be reflected by entries in the books of TLO. All quantities shall be adjusted to net gallons at 60° F in accordance with ASTM D-1250 Petroleum Measurement Tables, or latest revisions thereof. A barrel shall consist of 42 U.S. gallons and a gallon shall contain 231 cubic inches. Meters and temperature probes shall be calibrated according to applicable API standards. Tesoro shall have the right, at its sole expense, and in accordance with rack location procedure, to independently certify said calibration. Storage tank gauging shall be performed by TLO’s personnel. TLO’s gauging shall be deemed accurate unless challenged by an independent certified xxxxxx. Tesoro may perform joint gauging at its sole expense with TLO’s personnel at the time of delivery or receipt of Product, to verify the amount involved. If Tesoro should request an independent xxxxxx, such xxxxxx must be acceptable to TLO, and such gauging shall be at Tesoro’s sole expense.

  • Fuel Upon redelivery of the Aircraft to Lessor, an adjustment will be made in respect of fuel on board on the Previous Delivery Date and the Expiry Date at the price then prevailing at the Redelivery Location.

  • STORAGE TANKS AND SUMPS 3.1 Is any above or below ground storage of gasoline, diesel, petroleum, or other Hazardous Materials in tanks or sumps proposed in, on or about the Premises? Existing Tenants should describe any such actual or proposed activities. Yes [ ] No [ ] If yes, please explain:

  • Measurement and Monitoring Tools As of the Effective date, Vendor and Prudential will mutually agree on the measurements and service level management procedures, pursuant to the governance procedures set forth in Attachment G and performance standards set forth in Attachment E-1 and E-2, to measure Vendor's performance of the Services against the applicable Service Levels. Such measurement and monitoring tools and procedures will (a) for Attachment E-1, be implemented upon the Effective Date; (b) for Attachment E-2, be implemented after successful completion of all testing and written acceptance by Prudential of the Transition Services set forth in Attachment B-1; (c) permit reporting at a level of detail sufficient to verify compliance with the Service Levels; and (d) be subject to audit by Prudential or its designee in accordance with the Agreement, except such audit will not include the installation of any audit software on Vendor's network.

  • Maintenance and Repair; Return (a) Lessee, at its sole cost and expense, shall maintain each Property in good condition, repair and working order (ordinary wear and tear excepted) and in the repair and condition as when originally delivered to Lessor and make all necessary repairs thereto and replacements thereof, of every kind and nature whatsoever, whether interior or exterior, ordinary or extraordinary, structural or nonstructural or foreseen or unforeseen, in each case as required by Section 9.1 and on a basis consistent with the operation and maintenance of properties or equipment comparable in type and function to the applicable Property, such that such Property is capable of being immediately utilized by a third party and in compliance with standard industry practice subject, however, to the provisions of Article XV with respect to Casualty and Condemnation.

  • Delivery Points The measurement of and tests for quality of Shipper's Gas redelivered at the Delivery Points shall be governed by and determined in accordance with the requirements of the receiving pipeline at each Delivery Point.

  • Cost of Metering The Issuer shall not be obligated to pay any costs associated with the routine metering duties set forth in this Section 2, including the costs of installing, replacing and maintaining meters, nor shall the Issuer be entitled to any credit against the Servicing Fee for any cost savings realized by the Servicer as a result of new metering and/or billing technologies.

  • Metering 1. If the Producer desires to sell electric power to the Company, the Company shall provide, own and maintain at the Producer's expense all necessary meters and associated equipment to be utilized for the measurement of energy and capacity for determining the Company's payment to the Producer pursuant to an applicable agreement.

  • Mission Block Fuel The block fuel for a stage length of 2,050 nautical miles in still air (representative of a route with a 4.4 hour flight time from a sea level airport) with a zero fuel weight of 154,221 kilograms, using the conditions and operating rules defined below, shall not be more than the following guarantee value: NOMINAL: [*] Kilograms TOLERANCE: [*] Kilograms GUARANTEE: [*] Kilograms Conditions and operating rules:

Time is Money Join Law Insider Premium to draft better contracts faster.