Gas Meter Standards. Orifice meters installed in such measuring stations for Gas shall be constructed and operated in accordance with ANSI/API 2530 API 14.3, AGA Report No. 3, Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids (including as it may be revised from time to time) and shall include the use of flange connections and, where necessary, straightening vanes, flow conditioners and/or pulsation dampening equipment. Ultrasonic meters or Coriolis meters installed in such measuring stations shall be constructed and operated in accordance with AGA Report No. 9, Measurement of Gas by Ultrasonic Meters, First Edition, and AGA Report No. 11, Measurement of Natural Gas by Coriolis Meter, respectively; and any subsequent modification and amendment thereof generally accepted within the Gas industry. Electronic flow computers shall be used and the Gas shall have its volume, mass, and/or heat content computed in accordance with the applicable AGA standards including, but not limited to, AGA Report Nos. 3, 5, 6, 7, 8 and API 21.1 “Flow Measurement Using Electronic Metering Systems” and any subsequent modifications and amendments thereof generally accepted within the Gas industry. When Gas chromatographs are used they shall be installed, operated, maintained, and verified according to industry standards (GPA 2261, GPA 2145, GPA 2172, and GPA 2177).

Appears in 2 contracts

Samples: Gas Processing Agreement (Altus Midstream Co), Gas Processing Agreement (Altus Midstream Co)

AutoNDA by SimpleDocs

Gas Meter Standards. Orifice meters installed in such measuring stations for Gas shall be constructed and operated in accordance with ANSI/API 2530 API 14.3, AGA Report No. 3, Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids (including as it may be revised from time to time) and shall include the use of flange connections and, where necessary, straightening vanes, flow conditioners conditioners, and/or pulsation dampening equipment. Ultrasonic meters or Coriolis meters installed in such measuring stations shall be constructed and operated in accordance with AGA Report No. 9, Measurement of Gas by Ultrasonic Meters, First Edition, and AGA Report No. 11, Measurement of Natural Gas by Coriolis Meter, respectively; and any subsequent modification and amendment thereof generally accepted within the Gas industry. Electronic flow computers shall be used and the Gas shall have its volume, mass, and/or heat content computed in accordance with the applicable AGA standards including, but not limited to, AGA Report Nos. 3, 5, 6, 7, 8 and API 21.1 “Flow Measurement Using Electronic Metering Systems” and any subsequent modifications and amendments thereof generally accepted within the Gas industry. When Gas chromatographs are used they shall be installed, operated, maintained, and verified according to industry standards (GPA 2261, GPA 2145, GPA 2172, and GPA 2177).

Appears in 1 contract

Samples: Gas Gathering Agreement (Altus Midstream Co)

AutoNDA by SimpleDocs

Gas Meter Standards. Orifice meters installed in such measuring stations for Gas shall be constructed and operated in accordance with ANSI/API 2530 API 14.3, AGA Report No. 3, Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids (including Fluids, as it may be revised is now and from time to time) time may be revised, amended, or supplemented and shall include the use of flange connections and, where necessary, straightening vanes, flow conditioners and/or pulsation dampening equipment. Ultrasonic meters or Coriolis meters installed in such measuring stations shall be constructed and operated in accordance with AGA Report No. 9, Measurement of Gas by Ultrasonic Meters, First Edition, and AGA Report No. 11, Measurement of Natural Gas by Coriolis Meter, respectively; and any subsequent modification and amendment thereof generally accepted within the Gas industry. Electronic flow computers shall be used and the Gas shall have its volume, mass, and/or heat content computed in accordance with the applicable AGA standards including, but not limited to, AGA Report Nos. 3, 5, 6, 7, 8 and API 21.1 “Flow Measurement Using Electronic Metering Systems” and any subsequent modifications and amendments thereof generally accepted within the Gas industry. When Gas chromatographs are used they shall be installed, operated, maintained, and verified according to industry standards (GPA 2261, GPA 2145, GPA 2172, and GPA 2177).

Appears in 1 contract

Samples: Gas Gathering Agreement (Sandridge Energy Inc)

Time is Money Join Law Insider Premium to draft better contracts faster.