Gradation Requirements Sample Clauses

Gradation Requirements. Gradation requirements specified herein shall apply to the completed compacted base course. The aggregates shall have a maximum size of 50 mm (2 inch) and be graded continuously well within the limits specified in Table I. Sieves shall conform to ASTM E 11. TABLE I. GRADATION OF AGGREGATES Percentage by Weight Passing Square-Mesh Sieve: Sieve Designation Percent Passing 50 mm (2 inches) 100 37.5 mm (1 ½ inches) 70-100 12.5 mm (1/2 inch) 30-60 4.75 mm (No. 4) 10-35 2.36 mm (No. 8) 5-25 425 μm (No. 40) 4-18 75 μm (No. 200) 0-10 Liquid limit and plasticity index requirements stated herein shall apply to any aggregate component that is blended to meet the required gradation and also to the aggregate in the completed base course. The portion of the aggregate passing the 425 um (No. 40) sieve shall be either non-plastic or have a liquid limit not greater than 25 and a plasticity index not greater than 5.
AutoNDA by SimpleDocs
Gradation Requirements. The Contractor shall rigidly follow the gradation requirements of O.P.S.S. 1006, O.P.S.S. 1010. Oversize material or material outside of the Specification for Class 2 Aggregate, Granular – CLASS 6-HL3 or Granular M will not be accepted.
Gradation Requirements. The Contractor shall rigidly follow the gradation requirements of O.P.S.S.1006 , O.P.S.S. 1010.
Gradation Requirements. Add the following to this subsection: Provide necessary means to obtain an aggregate sample from the batch plant conveyor belt. Construct the sampling device so representative samples may be taken as required. Deliver the samples by mechanical means to a point on the ground or other satisfactory safe and accessible location. If two consecutive sieve analysis results are out of specification, reprocess failing stockpile or stockpiles. If three consecutive sieve analysis results are out of specification, stockpile or stockpiles will be rejected. Once rejected material has been replaced, provide informational results indicating the new material is within specification.

Related to Gradation Requirements

  • GRADUATION REQUIREMENTS I understand that in order to graduate from the program and to receive a certificate of completion, diploma or degree I must successfully complete the required number of scheduled clock hours as specified in the catalog and on the Enrollment Agreement, pass all written and practical examinations with a minimum score of 80%, and complete all required clinical hours and satisfy all financial obligations to the College. Initial

  • Notification Requirements 1. If the Family Leave is foreseeable, the employee must provide the agency/department with thirty (30) calendar days notice of his or her intent to take Family Leave.

  • Certification Requirements The applicant will provide Vista Laboratories, Inc. with all product information for the evaluation of the product to be certified and warrant that the information provided is accurate and complete so that Vista Labs may perform the services requested. If the product was tested at an external laboratory, the applicant must provide the complete test report to Vista Labs. If the external testing facility is not ISO 17025 accredited, or does not have the proper scope, Vista Labs must determine if the test report can be used for certification activities. The applicant’s information is used to perform a product review and evaluation to determine the product’s compliance to the specific certification requested. Throughout the process, the client agrees to make claims regarding certification consistent with the scope of certification. The applicant agrees to supply the required number of product samples, to be determined by Vista Labs, to the laboratory for testing, measurement, and evaluation purposes. The client understands that certain tests may damage or destroy the sample and acknowledge that Vista Labs is not responsible for such damages. Samples will be returned only upon request by the applicant and at the applicant’s expense, after the completion of certification. Samples will be disposed of after six months if not requested for return by applicant. The product is ineligible for certification if it has been modified by the client after testing or certification. Changes to the product must be approved by Vista Laboratories. Vista Labs reserves the right to re- evaluate the product as a result of information that raises questions concerning the conformance of the product. Certified products maintain fulfilment of product requirements if the certification applies to ongoing production. If the client provides copies of the certification documents to other parties, the documents are reproduced in their entirety, or as specified in the certification scheme. In making reference to its product certification in media, such as brochures or advertisement, the client complies with the requirements of the Vista Labs or as specified by the certification scheme. The client complies with any requirements that may be prescribed in the certification scheme relating to the use of marks of conformity, and on all product correspondences and product related information. Vista Labs reserves the right to revise or withdraw the requirements as required in order to maintain conformance with FCC rules and regulations governing the product. The product may continue with certification and receive certification upon demonstration of compliance with the revised requirements, to the satisfaction of Vista Laboratories.

  • Construction Requirements a) All Life and Safety and applicable Building Codes will be strictly enforced (i.e., tempered glass, fire dampers, exit signs, smoke detectors, alarms, etc.). Prior coordination with the Building Manager is required.

  • Installation requirements 7.8 We (if we install the System) or our contractor (if we procure a contractor to install the System) must:

Time is Money Join Law Insider Premium to draft better contracts faster.