Common use of Insulation Resistance Test Clause in Contracts

Insulation Resistance Test. This test is designed to check for a potential failure of the insulation between the connection pins and the housing of the natural gas detector. Apply 1,000 V DC between one of the connector pins and the housing of the natural gas detector for at least 2 seconds. The minimum allowable resistance shall be 10 MΩ.

Appears in 5 contracts

Samples: unece.org, unece.org, unece.org

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!