Common use of Insulation Resistance Test Clause in Contracts

Insulation Resistance Test. This test is designed to check for a potential failure of the insulation between the connection pins and the housing of the natural gas detector. Apply 1,000 V DC between one of the connector pins and the housing of the natural gas detector for at least 2 seconds. The minimum allowable resistance shall be 10 MΩ.

Appears in 5 contracts

Samples: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations