Large disturbances Sample Clauses

Large disturbances. Large disturbances are characterized by voltage falling outside of the continuous operating range. The Facility shall adhere to the following characteristics for large disturbances: The response of each generating resource over its full operating range and for all expected grid conditions should be stable. The dynamic performance of each resource should be tuned to provide this stable response. Company will work with Seller to ensure during the interconnection process that each resource supports Company System reliability and provides a stable transient response to grid events. [Note - The performance specifications described here may need to be modified based on studies performed for specific interconnections to provide a stable response.] Inverter-based resources shall operate in closed loop automatic voltage control at all times to support voltage regulation and voltage stability. Either the individual inverters or the plant-level closed loop automatic voltage controller must operate with a relatively fast response characteristic to mitigate steady-state voltage issues from causing dynamic voltage collapse. The plant-level controller may send voltage or reactive power set point changes to the individual inverters relatively fast, or the inverters will respond locally (depending on control architecture). For a large disturbance step in voltage, measured at the inverter terminals, where voltage falls outside the continuous operating range, the positive sequence component of the inverter reactive current response must meet the performance specifications set forth below. These parameters may be adjusted following additional study and/or operational testing and performance. Reaction time: Time between the step change in voltage and when the resource reactive power output begins responding to the change. The reaction time shall be less than 16 msec. Rise time: Time between a step change in control signal input and when the reactive power output changes by 90 percent of its final value. The rise time shall be less than 100 msec. Overshoot: Percentage of rated reactive current output that the resource can exceed when reaching the settling band. Overshoot will be determined following the IRS such that any overshoot in reactive power response does not cause Company System voltages to exceed acceptable voltage limits. The magnitude of the dynamic response may be requested to be reduced based on stability studies or actual operational data review.
AutoNDA by SimpleDocs
Large disturbances. Large disturbances are characterized by voltage falling outside of the continuous operating range. The Facility shall adhere to the following characteristics for large disturbances:

Related to Large disturbances

  • Earthquake including land shock waves or tremors before, during or after a volcanic eruption;

  • Labor Difficulties There is no labor strike, slowdown, stoppage or lockout actually pending, or, to the knowledge of the Company, threatened against the Company or any of the Company Subsidiaries. Neither the Company nor any Company Subsidiary has experienced any material labor strike, slowdown, stoppage or lockout during the past three (3) years.

  • Accidents and Claims The Manager shall promptly investigate and report in detail to the Owner all accidents, claims for damage relating to the ownership, operation or maintenance of the Properties, and any damage or destruction to the Properties and the estimated costs of repair thereof, and shall prepare for approval by the Owner all reports required by an insurance company in connection with any such accident, claim, damage, or destruction. Such reports shall be given to the Owner promptly and any report not so given within ten (10) days after the occurrence of any such accident, claim, damage or destruction shall be noted in the report delivered to the Owner pursuant to Section 2.5(b). The Manager is authorized to settle any claim against an insurance company arising out of any policy and, in connection with such claim, to execute proofs of loss and adjustments of loss and to collect and provide receipts for loss proceeds.

  • Soldiers' and Sailors' Civil Relief Act The Mortgagor has not notified the Seller, and the Seller has no knowledge of any relief requested or allowed to the Mortgagor under the Relief Act or any similar state statute;

  • CONTRACTS (RIGHTS OF THIRD PARTIES) ACT 1999 A person who is not a party to this Agreement will not have any right under the Contracts (Rights of Third Parties) Act 1999 to enforce any of its terms but this will not affect any right or remedy of a third party which exists or is available apart from that Act.

  • Shortages Claims for shortages in the amount of Products shipped by Patheon will be dealt with by reasonable agreement of the parties.

  • Unusual Transactions All Accounts have been originated by the Grantors and all Inventory has been acquired by the Grantors in the ordinary course of business.

  • Interruptions There shall be no abatement of rent and Lessor shall not be liable in any respect whatsoever for the inadequacy, stoppage, interruption or discontinuance of any utility or service due to riot, strike, labor dispute, breakdown, accident, repair or other cause beyond Lessor's reasonable control or in cooperation with governmental request or directions.

  • Force Majeure Events a) Neither Party shall be responsible or liable for or deemed in breach hereof because of any delay or failure in the performance of its obligations hereunder (except for obligations to pay money due prior to occurrence of Force Majeure events under this Agreement) or failure to meet milestone dates due to any event or circumstance (a "Force Majeure Event") beyond the reasonable control of the Party experiencing such delay or failure, including the occurrence of any of the following:

Time is Money Join Law Insider Premium to draft better contracts faster.