Material Specification Sample Clauses

Material Specification. All materials used must conform with the requirement of Sub- section 2 (Standards and Codes of Practice) and details of the materials proposed for all important plant items shall be submitted to the Engineer at the design stage and prior to manufacture. Proprietary materials not covered by appropriate specifications will only be considered on submission of the necessary technical details to permit a full and complete appraisal of their suitability for the proposed use.
AutoNDA by SimpleDocs
Material Specification. Sodium hypochlorite shall be tested and certified as meeting these specifications and those of the American National Standards Institute/National Sanitation Foundation Standard 60 (ANSI/NSF Standard 60), Drinking Water Treatment Chemicals Health Effects. Contractor shall to inform the County if its NSF certification has been revoked or lapsed within 24 hours of the time the supplier receives verbal or written notification from NSF. Loss of certification shall constitute sufficient grounds for immediate termination of this item from the agreement. Sodium hypochlorite shall have a minimum of 120 Grams Per Liter (GPL) available chlorine equivalent to 10.8 percent sodium hypochlorite by weight. Product shall be a clear straw colored liquid with no visible cloudiness, impurities, or sediment. Sodium hypochlorite shall have a minimum of 0.08 percent by weight excess sodium hydroxide and a maximum of 0.4 weight percent sodium hydroxide. Sodium hypochlorite delivered under the agreement shall meet the following containment concentration limits: • Iron <0.5 mg/L • Copper <0.05 mg/L • Nickel <0.05 mg/L • Chlorate <3,000 mg/L The suspended solids in the sodium hypochlorite delivered under the agreement shall be minimized and the shipments delivered shall achieve a filtration time of less than three minutes for 1000 when applying the “Suspended Solids Quality Test for Bleach Using the Vacuum Filtration” Method developed by Novatek and referenced under the Sampling and Testing Prior to Unloading detailed in this Section.
Material Specification. Valve Size : 50-300 mm Main valve body and cover : Cast Iron Main valve trim : Stainless steel End detail : SABS 1123 table 1600/3 or 2500/3 as specified Pressure rating : 0-50° Coating : Fusion bonded epoxy Desired options:- • X43 “y” strainer or equivalent on pilot piping • Three ball valves on pilot piping, inlet, outlet and line to cover chamber • 63 mm diameter pressure gauge, glycerine filled, fitted with 10 mm stainless steel ball valve on Tee-piece on inlet and outlet pilot piping.
Material Specification. Valve Size :50-300mm Main valve Body : 316 Stainless steel End Detail (50 to 100 mm) : Wafer pattern End Detail (150 to 300mm) : SABS 1123 Table 1600/3 or 2500/3 as specified Pressure rating : 1600 kPa or 2500 kPa as specified Temperature range : 0 to 70° Liner Material : Natural Rubber Liner retainer : 316 Stainless Steel Coating : Fusion bonded epoxy Desired options:- • X43 “y” strainer or equivalent on pilot piping • Three ball valves on pilot piping, inlet, outlet and line to cover chamber • 63 mm diameter pressure gauge, glycerine filled, fitted with 10 mm stainless steel ball valve on Tee-piece on inlet and outlet pilot piping.

Related to Material Specification

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • EODUF Packing Specifications 7.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Billing Specifications 55.6.1 The Parties agree that billing requirements and outputs will be consistent with the Ordering & Billing Form (OBF) and also with Telcordia Technologies Billing Output Specifications (BOS).

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

Time is Money Join Law Insider Premium to draft better contracts faster.