Common use of Measurement Accuracy Verification Clause in Contracts

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Point flow rate (Mcf/Day). Any flow rate at a Receipt Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Gathering Agreement (Altus Midstream Co)

AutoNDA by SimpleDocs

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Delivery Point flow rate (Mcf/Day). Any flow rate at a Receipt Delivery Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 1,000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement5.5. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or Gas Processing Agreement dated September 1, 2021 Between Altus Midstream Processing LP (Processor) and Apache Corporation (Producer) calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.65.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Processing Agreement (Altus Midstream Co)

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Point flow rate (Mcf/Day). Any flow rate at a Receipt Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Gathering Agreement (Altus Midstream Co)

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Delivery Point flow rate (Mcf/Day). Any flow rate at a Receipt Delivery Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 1,000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement5.5. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.65.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Processing Agreement (Altus Midstream Co)

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Delivery Point flow rate (Mcf/Day). Any flow rate at a Receipt Delivery Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 1,000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement5.5. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found Gas Processing Agreement dated [______________] Between Alpine High Processing LP (Processor) and [_____________] (Producer) that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.65.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Processing Agreement (Altus Midstream Co)

AutoNDA by SimpleDocs

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall be based upon each Receipt Delivery Point flow rate (Mcf/Day). Any flow rate at a Receipt Delivery Point that is: (x) greater than 1,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 1,000 Mcf/Day shall be tested quarterly, and (z) less than 100 Mcf/Day shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 of this Agreement5.5. If, upon testing, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two percent (2%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.65.6. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.. Gas Processing Agreement dated July 1, 2018 Between Alpine High Processing LP (Processor) and Apache Corporation (Producer)

Appears in 1 contract

Samples: Gas Processing Agreement (Altus Midstream Co)

Measurement Accuracy Verification. Each Party shall verify the accuracy of all transmitters, flow computers, and other equipment used in the measurement of the Gas hereunder at intervals not to exceed one hundred eighty (180) Days and cause such equipment to be adjusted or calibrated as necessary. Testing frequency shall will be based upon each Receipt Point well or station’s flow rate (Mcf/Day). Any flow rate at a Receipt Point that is: (x) greater than 1,000 or equal to 5,000 Mcf/Day shall be tested Monthly, (y) between 101 and 1000 monthly. Any flow rate that is greater than or equal to 1,000 Mcf/Day shall be tested quarterlyDay, and (z) but less than 100 5,000 Mcf/Day Day, shall be tested semi-annually. Neither Party shall be required to cause adjustment or calibration of such equipment more frequently than once every Month, unless a special test is requested pursuant to Section 10.5 13.5 of this Agreement. If, upon testingtest, (i) no adjustment or calibration error is found that results in an incremental adjustment to the calculated flow rate through each meter run in excess of two one percent (21%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) or (ii) any quantity error is not greater than two hundred fifty (250) Mcf per Month, then any previous recordings of such equipment shall be considered accurate in computing deliveries but such equipment shall be adjusted or calibrated at once. If, during any test of the measuring equipment, an adjustment or calibration error is found that results in (i) an incremental adjustment to the calculated flow rate through each meter run in excess of two one percent (21%) of the adjusted flow rate (whether positive or negative and using the adjusted flow rate as the percent error equation denominator) and (ii) a quantity error greater than two hundred fifty (250) Mcf per Month Pg 20 of 68 Gas Gathering Agreement dated July 1, 2018 Between Alpine High Gathering LP (Gatherer) and Apache Corporation (Producer) CONFIDENTIAL TREATMENT REQUESTED (“Material Measurement Error”), then any previous recordings of such equipment shall be corrected to zero error for any period during which the error existed (and which is either known definitely or agreed to by the Parties) and the total flow for such period shall be determined in accordance with the provisions of Section 10.613.6 of this Agreement. If the period of error condition cannot be determined or agreed upon between the Parties, such correction shall be for a period extending over the last one half (1/2) of the time elapsed since the date of the last test.

Appears in 1 contract

Samples: Gas Gathering Agreement (Sandridge Energy Inc)