Mechanical Noise Sample Clauses

Mechanical Noise. Sound control and vibration isolation techniques shall meet the following noise criteria requirements. Private Offices NC 30-35 General office space in excess of 6.0 meters from core areas NC 35-40 General office space within 6.0 meters of core areas NC 35-40 Lobbies, corridors, and areas adjacent to the core and/or mechanical duct shafts NC 40-45 Service spaces and parking garages NC 45-50 The capacity of the mechanical systems and the operation thereof during Business Hours, will comply with the thermal comfort standards as defined in ASHRAE 55-2004, Thermal Environment Conditions for Human Occupancy. Building heating will be provided by multiple gas-fired condensing type hot water boilers located in the mechanical penthouse. Building cooling will be provided by multiple non CFC-based centrifugal chillers. The chillers will be located in a mechanical penthouse. Associated cooling towers shall be located outdoors adjacent to the mechanical penthouse. The chilled water pumping system shall be complete with variable speed drives to conserve energy during periods of reduced chilled water demand. Building humidification will be provided by multiple gas-fired humidifiers located in the mechanical penthouse. Building ventilation will be provided by heat/cool make-up air unit located in the mechanical penthouse. A variable frequency drive shall be provided to minimize fan energy consumption during periods of reduced occupancy. Outside air intakes will be located in a manner to be free of pollutants. Exhaust and relief air outlets (i.e. chimneys, flue gas stack, cooling towers, etc.) will be located well clear of intakes to meet Ministry of the Environment guidelines. The make-up air unit for the Building ventilation will be provided with 2-stage filtration. Pre-filters shall be rated for MERV 6. Final filters shall be rated for MERV 13. All enclosed areas used as indoor car parking garages will be ventilated in accordance with Ontario Building Code requirements. Air pressures within the garage area will be maintained negative in relation to surrounding building areas. Ceilings shall be free of base building cross floor exhaust ducts and exit stair pressurization ducts subject to multiple tenant floor requirements. Typical floors will be conditioned by compartmental VAV air handling units, one per floor, to meet the required air conditioning load. Unit fan(s) shall be supplied with variable frequency drives for reduced energy consumption. Each compartmental unit ...

Related to Mechanical Noise

  • Mechanical (i) Large scale mechanical details complete. (ii) Mechanical schedules for equipment completed. (iii) Completed electrical schematic for environmental cooling and exhaust equipment. (iv) Complete energy conservation calculations and report.

  • Mechanical Rights The Licensor hereby grants to Licensee a non-exclusive License to use Master Recording in the reproduction, duplication, manufacture, and distribution of phonograph records, cassette tapes, compact disks, internet downloads, other and miscellaneous audio and digital recordings, and any lifts and versions thereof (collectively ,”Recordings”) worldwide for up to the pressing or selling a total of 5000 copies of such Recordings or any combination of such Recordings. Additionally, Licensor shall be permitted to distribute unlimited internet downloads for non-profit and non-commercial use.

  • Compressed Work Week The Company and Union recognize the concept of the compressed work week. It is further understood that the compressed work week conditions will apply only to those departments that are on the compressed work week.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • Electrical Items All electrical items purchased under this Grant Agreement/Contract or used in the performance of approved and eligible grant-funded activities must meet all applicable Occupational Safety and Health Administration (OSHA) standards and regulations, and bear the appropriate listing from Underwriters Laboratory (UL), Factory Mutual Resource Corporation (FMRC), or National Electrical Manufacturers Association (NEMA).