Electrical Items Sample Clauses

Electrical Items. All electrical items purchased under this Grant Agreement/Contract or used in the performance of approved and eligible grant-funded activities must meet all applicable Occupational Safety and Health Administration (OSHA) standards and regulations, and bear the appropriate listing from Underwriters Laboratory (UL), Factory Mutual Resource Corporation (FMRC), or National Electrical Manufacturers Association (NEMA).
AutoNDA by SimpleDocs
Electrical Items. All electrical items must meet all applicable OSHA standards and regulations, and bear the appropriate listing from Underwriters Laboratory (UL), Factory Mutual Resource Corporation (FMRC), or National Electrical Manufacturers Association (NEMA).
Electrical Items. You must make available to us promptly for inspection all electrical items you bring into the Home at any time, and must not use such items if they have not been inspected or fail the inspection.
Electrical Items. All Accommodation shall meet the following standards: 3.10.1 all Accommodation shall have a current NICEIC or NAPIT electrical safety report. This report must have no items marked as requiring urgent attention or investigation; 3.10.2 all electrical wiring shall be covered; 3.10.3 all surface mounted wiring shall be enclosed in suitable plastic conduit; 3.10.4 all RCD consumer unit shall be housed in a cupboard, with a childproof latch on the door to prevent access and ensure that cables under the meter are covered; 3.10.5 xxxxxx and cooker. Fused spurs shall be provided; 3.10.6 Portable Appliance Testing (PAT) is required annually for all electrical appliance supplied (e.g. electric cookers); 3.10.7 an adequate number of sockets shall be required and the following shall be appropriately spaced: (a) living room. Two double sockets as a minimum; (b) double bedrooms. Two double sockets as a minimum; (c) single bedrooms. One double socket as a minimum; (d) kitchen. Two double sockets at worktop height as a minimum, one socket for a fridge and one socket for a washing machine; (e) landing. One socket as a minimum; 3.10.8 electric lighting in each room is to be of sufficient intensity.
Electrical Items. 3.3.1 All electrical items offered for sale must: a) comply with the requirements of any applicable legislation, including the Electrical Equipment (Safety) Regulations 1994 and the General Product Safety Regulations 2005 b) be of good serviceable condition; c) be free from rust, mould and other major blemishes; d) be safety tested; and e) be offered for sale with a warranty of at least three months.
Electrical Items. A. Lighting: Description Quantity ----------- -------- A(AA,AH) 100 B(CA) 26 C(PA,PH) 271 D(FI) 183 E(EM) 67 F(HB) 103 G(SA) 17 H(ST) 20 K(XW) 14 M(XX) 2 X(EA) 28 XI(EB) 1 24' POLE SINGLE HEAD 6 27' POLE TWIN HEAD 4 DOCK LIGHT RECEPTACLES 9 B. WIRING DEVICES Description Quantity ----------- -------- SINGLE POLE SWITCH 64 THREE-WAY SWITCH 30 FOUR-WAY SWITCH 3 1000W DIMMER 1 1500W DIMMER 1 OCCUPANCY SENSOR 0 DUPLEX RECEPTACLE-OFFICE 126 DUPLEX RECEPTACLE-PRODUCTION 49 ISOLATED GROUND DUPLES RECEPTACLE 48 GFI RECEPTACLE 17 WEATHERPROOF GFI RECEPTACLE 4 30A 3-POLE 208V RECEPTACLE 1 C. SOUND SYSTEM Description Quantity ----------- -------- VOLUME CONTROL 0 OFFICE SPEAKER 0 PRODUCTION SPEAKER 5 AMPLIFIER 1 D. TELEPHONE Description Quantity ----------- -------- 2" EMPTY CONDUIT 300 ft EQUIPMENT BOARD 1 VOICE/DATA OPENINGS LAB 66 VOICE/DATA TRAINING RM 63 E. EQUIPMENT/CORD DROPS Description Quantity ----------- -------- DUPLEX 177 20A 3-POLE 208V 19
Electrical Items. All electrical items provided by the Respondent to the CPA or a Customer under the Contract must meet all applicable OSHA standards and regulations, and bear the appropriate listing from UL, FMRC, or NEMA.
AutoNDA by SimpleDocs
Electrical Items. All items stored on the premises must have a current PAT test label. Any items used on the premises by professionals hired for the occasion must comply, for example a professional Disco, rather than the hirers own domestic equipment.
Electrical Items. All items stored on the premises must have a current XXX test label. Any items used on the premises by professionals hired for the occasion must comply, for example a professional Disco, rather than the hirers own domestic equipment.
Electrical Items. Provide electrical feed to all work station clusters and to the table tops in the conference rooms (3x). Include core drills or trenching as required. • All conference rooms should have data available on 3 - 4 walls of the room (where there is sheet rock) located next to power outlets. • Large(er) Conference rooms (1x6 seat & Executive Conference Room) Requires cables to be run to under the conference room table, via conduit under the floor or through a channel in the slab. The conduit size should be 1.5”. The cables will terminate in the table. Location TBD once furniture is chosen. • 5 x data, 1 x power - Cables to run from behind wall mounted TV to conference room table • 5 x data, 1 x power - Data and power location behind TV on wall location TBD • Small 4 seat conference rooms (these rooms will not have a TV) Require cables to be run to under the conference room table. The cables will terminate in the table. Location TBD once furniture is chosen. 4 x data, 1 x power
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!