Common use of MOISTURE WARRANTY Clause in Contracts

MOISTURE WARRANTY. Mohawk hereby warrants to the Buyer of Mohawk engineered and longstrip wood flooring products against moisture damage due to topical spills or subfloor moisture for as long as the Buyer owns the home. Topical spills of normal household substances (food and beverage) must be removed promptly. Topical spills allowed to remain on the floor for any considerable time will damage the Mohawk Wood Floor and void this warranty. Flooding, acts of God, plumbing accidents, leaking appliances (icemakers, dishwashers, clothes washers, etc.) are not topical spills and are not covered by this warranty. Mohawk engineered or longstrip wood products may be installed on, above or below grade on all common subfloors and are warranted against subfloor moisture if the following conditions are met: • Written verification that the concrete subfloor has moisture of no more than 3 lbs./1000 square feet/24 hours using a calcium chloride test; or Written verification that the concrete subfloor has an acceptable reading using an electronic concrete moisture meter; or • Written verification that the wood subfloors have a moisture reading of less than 13% using an electronic wood moisture meter; and • Mohawk Wood Flooring Adhesive is used. It is important that you keep your original sales receipt showing Mohawk Wood Flooring Adhesive was installed. If the floor fails due to the incursion of moisture from the subfloor, Mohawk will replace the damaged material at no cost to the Buyer for one time only, provided that testing approved by Mohawk indicates that moisture penetrated the subfloor. This includes material only. Labor is excluded from this warranty and labor costs must be incurred by the Buyer. Please note that this applies to engineered and longstrip wood only. Solid wood products are not approved for direct glue applications and are not covered by this warranty. These limited warranties do not include the removal or replacement of cabinets, fixtures, retail markups, installation or labor provided for others Jobsite Conditions Mohawk recommends that all Mohawk Wood Floor be acclimated a minimum of at least 72 hours before installation. The purpose of acclimation is to allow the moisture content of the wood to adjust to “normal living conditions” at the site. These are the temperature and humidity conditions that will typically be experienced once the structure is occupied. Engineered: The room temperature must be within a range of 60 – 80o F, with relative humidity in a range of 35 – 55%. Concrete subfloor moisture must not exceed 3lb per 1000 square feet per 24 hours (ASTM 1869 or ASTM F2170-02). These environmental conditions are specified as pre-installation requirements and should be maintained for the life of the product. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties. o Solid: The room temperature must be within a range of 60 – 80 F, with relative humidity in a range of 35 – 55%. The subfloor and flooring should be tested with an appropriate moisture meter. The subfloor moisture level must not exceed 12%. The difference between the moisture content of the wood subfloor and the solid hardwood flooring must not exceed 4% for products less than 3” wide. For solid hardwood products equal to or greater than 3” wide, the moisture content of the wood subfloor and hardwood floor should not differ more than 3%. Solid wood is not suitable for application over a concrete subfloor. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties.

Appears in 4 contracts

Samples: customcarpetcenters.com, images.thdstatic.com, s1.img-b.com

AutoNDA by SimpleDocs

MOISTURE WARRANTY. Mohawk hereby warrants to the Buyer of Mohawk engineered and longstrip wood flooring products against moisture damage due to topical spills or subfloor moisture for as long as the Buyer owns the home. Topical spills of normal household substances (food and beverage) must be removed promptly. Topical spills allowed to remain on the floor for any considerable time will damage the Mohawk Wood Floor and void this warranty. Flooding, acts of God, plumbing accidents, leaking appliances (icemakers, dishwashers, clothes washers, etc.) are not topical spills and are not covered by this warranty. Mohawk engineered or longstrip wood products may be installed on, above or below grade on all common subfloors and are warranted against subfloor moisture if the following conditions are met: • Written verification that the concrete subfloor has moisture of no more than 3 lbs./1000 square feet/24 hours using a calcium chloride test; or Written verification that the concrete subfloor has an acceptable reading using an electronic concrete moisture meter; or • Written verification that the wood subfloors have a moisture reading of less than 13% using an electronic wood moisture meter; and • Mohawk Wood Flooring Adhesive is used. It is important that you keep your original sales receipt showing Mohawk Wood Flooring Adhesive was installed. If the floor fails due to the incursion of moisture from the subfloor, Mohawk will replace the damaged material at no cost to the Buyer for one time only, provided that testing approved by Mohawk indicates that moisture penetrated the subfloor. This includes material only. Labor is excluded from this warranty and labor costs must be incurred by the Buyer. Please note that this applies to engineered and longstrip wood only. Solid wood products are not approved for direct glue applications and are not covered by this warranty. These limited warranties do not include the removal or replacement of cabinets, fixtures, retail markups, installation or labor provided for others Jobsite Conditions Mohawk recommends that all Mohawk Wood Floor be acclimated a minimum of at least 72 hours before installation. The purpose of acclimation is to allow the moisture content of the wood to adjust to “normal living conditions” at the site. These are the temperature and humidity conditions that will typically be experienced once the structure is occupied. Engineered: The room temperature must be within a range of 60 – 80o F, with relative humidity in a range of 35 – 5560%. Concrete subfloor moisture must not exceed 3lb per 1000 square feet per 24 hours (ASTM 1869 or ASTM F2170-02). These environmental conditions are specified as pre-installation requirements and should be maintained for the life of the product. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties. o Solid: The room temperature must be within a range of 60 – 80 F, with relative humidity in a range of 35 – 55%. The subfloor and flooring should be tested with an appropriate moisture meter. The subfloor moisture level must not exceed 12%. The difference between the moisture content of the wood subfloor and the solid hardwood flooring must not exceed 4% for products less than 3” wide. For solid hardwood products equal to or greater than 3” wide, the moisture content of the wood subfloor and hardwood floor should not differ more than 3%. Solid wood is not suitable for application over a concrete subfloor. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties.

Appears in 1 contract

Samples: efloors.com

AutoNDA by SimpleDocs

MOISTURE WARRANTY. Mohawk hereby warrants to the Buyer of Mohawk engineered and longstrip wood Engineered Hardwood flooring products against moisture damage due to topical spills or subfloor moisture for as long as the Buyer owns the home. Topical spills of normal household substances (food and beverage) must be removed promptly. Topical spills allowed to remain on the floor for any considerable time will damage the Mohawk Wood Floor and void this warranty. Flooding, acts of God, plumbing accidents, leaking appliances (icemakers, dishwashers, clothes washers, etc.) are not topical spills and are not covered by this warranty. Mohawk engineered or longstrip wood Wood Floor products may be installed on, above or below grade on all common subfloors and are warranted against subfloor moisture if the following conditions are met: • Written verification that the concrete subfloor has moisture of no more than 3 lbs./1000 lbs. per 1000 square feet/24 feet per 24 hours using a calcium chloride test; or Written verification that the concrete subfloor has an acceptable reading using an electronic concrete moisture meter; or Moisture Warranty (cont’d) • Written verification that the wood subfloors have a moisture reading of less than 1312% using an electronic wood moisture meter; and • Mohawk Wood Flooring Adhesive Adhesive, or a suitable alternative, is used. It is important that you keep your Buyer must present original sales receipt showing installation of Mohawk Wood Flooring Adhesive was installedor a suitable alternative. If the floor fails due to the incursion of moisture from the subfloor, Mohawk will replace the damaged material at no cost to the Buyer for one time only, provided that testing approved by Mohawk indicates that moisture penetrated the subfloor. This includes These limited warranties cover material only. Labor is excluded from this warranty and labor costs must be incurred by the Buyer. Please note that this applies to engineered and longstrip wood only. Solid wood products are not approved for direct glue applications and are not covered by this warranty. These limited warranties do not include the removal or replacement of cabinets, fixtures, retail markups, installation or labor provided for others others. Jobsite Conditions Mohawk recommends that all wood subfloors be below 12% moisture content and that Mohawk Wood Floor Floors be acclimated a minimum of at least 72 hours before installation. The purpose of acclimation is to allow the moisture content within 4% of the wood subfloor moisture readings to adjust to “normal living conditions” at install the siteproduct. These Do not install the floor until these moisture conditions are the temperature and humidity conditions that will typically be experienced once the structure is occupiedmet. Engineered: The room temperature must be within a range of 60 – 80o F60˚ to 80℉, with relative humidity in a range of 35 to 55%. Concrete subfloor moisture must not exceed 3lb per 1000 1,000 square feet per 24 hours (ASTM 1869 F1869 or or < 75% RH ASTM F2170-02). These environmental conditions are specified as pre-installation preinstallation requirements and should be maintained for the life of the product. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties. o Solid: The room temperature must be within a range of 60 – 80 F, with relative humidity in a range of 35 – 55%. The subfloor and flooring should be tested with an appropriate moisture meter. The subfloor moisture level must not exceed 12%. The difference between the moisture content of the wood subfloor and the solid hardwood flooring must not exceed 4% for products less than 3” wide. For solid hardwood products equal to or greater than 3” wide, the moisture content of the wood subfloor and hardwood floor should not differ more than 3%. Solid wood is not suitable for application over a concrete subfloor. Environmental conditions consistently outside of these parameters could result in product performance problems that would not be covered under these warranties.

Appears in 1 contract

Samples: pdf.lowes.com

Time is Money Join Law Insider Premium to draft better contracts faster.