NON SKID TILE FLOORING AND GLAZED TILES SKIRTING/DADO Sample Clauses

NON SKID TILE FLOORING AND GLAZED TILES SKIRTING/DADO. 16.2.1 Refer para 13.14 & 13.15 of MES Schedule Part I. Non-skid ceramic tiles shall be of size as mentioned in Sch ‘A’ for flooring and glazed ceramic tiles shall be of size as mentioned in Sch ‘A’ for walls. Colour of both the tiles shall be approved by GE. The cement screed bed shall be as indicated in Sch ‘A’ for bedding, laying and finishing, refer para 13.40 of MES Schedule Part I 1991. Tiles shall conform to IS No 13712 and quality shall be economy finish as per class B-II (a) grade. Make shall be mentioned in List of some B/R and E/M makes. 16.2.2 Non skid ceramic tile floor :- Tiles of 7mm thick of size as specified in relevant items of Sch “A” Part –I and laid as per manufacturers instructions.
AutoNDA by SimpleDocs

Related to NON SKID TILE FLOORING AND GLAZED TILES SKIRTING/DADO

  • Unbundled Voice Loops (UVLs) 2.2.1 BellSouth shall make available the following UVLs:

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.1.3.1 Definition 4.1.3.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for <<customer_name>> when <<customer_name>> serves end-users with four (4) or more voice-grade (DS-0) equivalents or lines in locations served by BellSouth’s local circuit switches, which are in the following MSAs: Atlanta, GA; Miami, FL; Orlando, FL; Ft. Lauderdale, FL; Charlotte-Gastonia-Rock Hill, NC; Greensboro-Winston Salem-High Point, NC; Nashville, TN; and New Orleans, LA, and BellSouth has provided non-discriminatory cost based access to the Enhanced Extended Link (EEL) throughout Density Zone 1 as determined by NECA Tariff No. 4 as in effect on January 1, 1999. 4.1.3.3 In the event that <<customer_name>> orders local circuit switching for a single end user account name at a single physical end user location with four (4) or more 2-wire voice-grade loops from a BellSouth central office in an MSA listed above, BellSouth shall charge <<customer_name>> the market based rate in Exhibit C for use of the local circuit switching functionality for the affected facilities. 4.1.3.4 A featureless port is one that has a line port, switching facilities, and an interoffice port. A featured port is a port that includes all features then capable or a number of then capable features specifically requested by <<customer_name>>. Any features that are not currently then capable but are technically feasible through the switch can be requested through the NBR/BFR process. 4.1.3.5 BellSouth will provide to <<customer_name>> customized routing of calls: (i) to a requested directory assistance services platform; (ii) to an operator services platform pursuant to Section 10 of Attachment 2; (iii) for <<customer_name>>’s PIC’ed toll traffic in a two (2) PIC environment to an alternative OS/DA platform designated by <<customer_name>>. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers. 4.1.3.6 Remote Switching Module functionality is included in Switching Capability. The switching capabilities used will be based on the line side features they support. 4.1.3.7 Switching Capability will also be capable of routing local, intraLATA, interLATA, and calls to international customer’s preferred carrier; call features (e.g. call forwarding) and Centrex capabilities. 4.1.3.8 Where required to do so in order to comply with an effective Commission order, BellSouth will provide to <<customer_name>> purchasing local BellSouth switching and reselling BellSouth local exchange service under Attachment 1, selective routing of calls to a requested directory assistance services platform or operator services platform. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers, but obtain a <<customer_name>> branded service.

  • Tandem Transit Traffic ‌ 12.1 As used in this Section, Tandem Transit Traffic is Telephone Exchange Service traffic that originates on Onvoy's network, and is transported through Frontier’s Tandem to the subtending End Office or its equivalent of another carrier (CLEC, ILEC other than Frontier, Commercial Mobile Radio Service (CMRS) carrier, or other LEC (“Other Carrier”). Neither the originating nor terminating customer is a Customer of Frontier. Subtending End Offices shall be determined in accordance with and as identified in the Local Exchange Routing Guide (LERG). For the avoidance of any doubt, under no circumstances shall Frontier be required to transit traffic through a Frontier Tandem to a Central Office that the LERG does not identify as subtending that particular Frontier Tandem. Switched Exchange Access Service traffic is not Tandem Transit Traffic. 12.2 Tandem Transit Traffic Service provides Onvoy with the transport of Tandem Transit Traffic as provided below. 12.3 Tandem Transit Traffic may be routed over the Interconnection Trunks described in Sections 2 through 6 of this Attachment. Onvoy shall deliver each Tandem Transit Traffic call to Frontier’s Tandem with CCS and the appropriate Transactional Capabilities Application Part (“TCAP”) message to facilitate full interoperability of CLASS Features and billing functions. 12.4 Onvoy may use Tandem Transit Traffic Service only for traffic that originates on Onvoy’s network and only to send traffic to an Other Carrier with whom Onvoy has a reciprocal traffic exchange arrangement (either via written agreement or mutual tariffs) that provides for the Other Carrier, to terminate or complete traffic originated by Onvoy and to bill Onvoy, and not to bill Frontier, for such traffic. Onvoy agrees not to use Frontier’s Tandem Transit Traffic Service to send traffic to an Other Carrier with whom Onvoy does not have such a reciprocal traffic exchange arrangement or to send traffic that does not originate on Onvoy’s network. 12.5 Onvoy shall pay Frontier for Tandem Transit Traffic Service at the rates specified in the Pricing Attachment. Frontier will not be liable for compensation to any Other Carrier for any traffic that is transported through Frontier’s Tandem and Frontier reserves the right to assess to Onvoy any additional charges or costs any Other Carrier imposes or levies on Frontier for the delivery or termination of such traffic, including any Switched Exchange Access Service charges. If Frontier is billed by any Other Carrier for any traffic originated by Onvoy, Frontier may provide notice to Onvoy of such billing. Upon receipt of such notice, Onvoy shall immediately stop using Frontier’s Tandem Transit Traffic Service to send any traffic to such Other Carrier until it has provided to Frontier certification that the Other Carrier has removed such billed charges from its bill to Frontier and that the Other Carrier will not bill Frontier for any traffic originated by Onvoy. Such certification must be signed by an authorized officer or agent of the Other Carrier and must be in a form acceptable to Frontier. 12.6 If Onvoy uses Tandem Transit Traffic Service for traffic volumes that exceed the Centum Call Seconds (Hundred Call Seconds) busy hour equivalent of 200,000 combined minutes of use per month (a DS1 equivalent) to the subtending End Office of a particular Other Carrier for any month (the “Threshold Level”). Onvoy shall use good faith efforts to establish direct interconnection with such Other Carrier and reduce such traffic volumes below the Threshold Level. If Frontier believes that Xxxxx has not exercised good faith efforts promptly to obtain such direct interconnection, either Party may use the Dispute Resolution processes of this Agreement. 12.7 If Onvoy fails to comply with Section 12 of this Attachment, such failure shall be a material breach of a material provision of this Agreement and Frontier may exercise any and all remedies under this Agreement and Applicable Law for such breach. 12.8 If or when a third party carrier plans to subtend an Onvoy switch, then Onvoy shall provide written notice to Frontier at least ninety (90) days before such subtending service arrangement becomes effective so that Frontier may negotiate and establish direct interconnection with such third party carrier. Upon written request from Frontier, Onvoy shall offer to Frontier a service arrangement equivalent to or the same as Tandem Transit Traffic Service provided by Frontier to Onvoy as defined in this Section such that Frontier may terminate calls to a Central Office or its equivalent of a CLEC, ILEC other than Frontier, CMRS carrier, or other LEC, that subtends an Onvoy Central Office or its equivalent (“Reciprocal Tandem Transit Service”). Onvoy shall offer such Reciprocal Transit Service arrangements under terms and conditions of an amendment to this Agreement or a separate agreement no less favorable than those provided in this Section. 12.9 Neither Party shall take any actions to prevent the other Party from entering into a direct and reciprocal traffic exchange arrangement with any carrier to which it originates, or from which it terminates, traffic.

  • Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • COVID-19 Vaccine Passports Pursuant to Texas Health and Safety Code, Section 161.0085(c), Contractor certifies that it does not require its customers to provide any documentation certifying the customer’s COVID-19 vaccination or post-transmission recovery on entry to, to gain access to, or to receive service from the Contractor’s business. Contractor acknowledges that such a vaccine or recovery requirement would make Contractor ineligible for a state-funded contract.

  • Originating Switched Access Detail Usage Data A category 1101XX record as defined in the EMI Telcordia Practice BR-010-200- 010.

  • Geographic Area and Sector Specific Allowances, Conditions and Exceptions The following allowances and conditions shall apply where relevant. Where the Employer does work which falls under the following headings, the Employer agrees to pay and observe the relevant respective conditions and/or exceptions set out below in each case.

  • Mail Order Catalog Warnings In the event that, the Settling Entity prints new catalogs and sells units of the Products via mail order through such catalogs to California consumers or through its customers, the Settling Entity shall provide a warning for each unit of such Product both on the label in accordance with subsection 2.4 above, and in the catalog in a manner that clearly associates the warning with the specific Product being purchased. Any warning provided in a mail order catalog shall be in the same type size or larger than other consumer information conveyed for such Product within the catalog and shall be located on the same display page of the item. The catalog warning may use the Short-Form Warning content described in subsection 2.3(b) if the language provided on the Product label also uses the Short-Form Warning.

  • Non-Synchronous Generation The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the high-side of the generator substation at a power factor within the range of 0.95 leading to 0.95 lagging, unless the NYISO or the Transmission Owner in whose Transmission District the Small Generating Facility interconnects has established a different power factor range that applies to all similarly situated non-synchronous generators in the control area or Transmission District (as applicable) on a comparable basis, in accordance with Good Utility Practice. This power factor range standard shall be dynamic and can be met using, for example, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors, or a combination of the two. This requirement shall only apply to newly interconnecting non-synchronous generators that have not yet executed a Facilities Study Agreement as of September 21, 2016.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!