Common use of Optical Connectors Clause in Contracts

Optical Connectors. The CFP2 module shall support LC, MTP12 and MTP24 optical connector types, as listed in Table 5-3. The optical connectors are positioned in the CFP2 module as illustrated in Figure 5-10. The optical connector is centered in position along the X-axis (module width) with an offset tolerance of ±0.5mm. The position of the optical connector in the Y and Z axes shall be specified by the CFP2 module manufacturer. Table 5-3: Optical Connectors8 Pin # Category Reference Number LC Connector TBA TBA MPO12 Connector TBA TBA MPO24 Connector TBA TBA 8 Other optical connectors may be supported Figure 5-10: CFP2 Optical Connector Position Offset 2mm Transmitter Receiver Module center Connector center

Appears in 3 contracts

Samples: www.prolabs.com, www.gigalight.com, www.fluxlight.com

AutoNDA by SimpleDocs

Optical Connectors. The CFP2 CFP8 module shall support LC, MTP12 and MTP24 MTP16 optical connector types, as listed in Table 5-3. The optical connectors are positioned in the CFP2 CFP8 module as illustrated in Figure 5-10. The optical connector is centered in position along the X-axis (module width) with an offset tolerance of ±0.5mm. The position of the optical connector in the Y and Z axes shall be specified by the CFP2 module manufacturer. Table 5-3: Optical Connectors8 Connectors5 Pin # Category Reference Number LC Connector TBA TBA MPO12 Connector TBA TBA MPO24 MPO16 Connector TBA TBA 8 MPO32 Connector TBA TBA 5 Other optical connectors may be supported Figure 5-10: CFP2 CFP8 Optical Connector Position Offset 2mm Transmitter Receiver Module center Connector centerPosition

Appears in 2 contracts

Samples: ascentoptics.com, cfp-msa.org

AutoNDA by SimpleDocs

Optical Connectors. The CFP2 module shall support LC, MTP12 and MTP24 optical connector types, as listed in Table 5-3. The optical connectors are positioned in the CFP2 module as illustrated in Figure 5-10. The optical connector is centered in position along the X-axis (module width) with an offset tolerance of ±0.5mm. The position of the optical connector in the Y and Z axes shall be specified by the CFP2 module manufacturer. Table 5-35‐3: Optical Connectors8 Pin # Category Reference Number LC Connector TBA TBA MPO12 Connector TBA TBA MPO24 Connector TBA TBA 8 Other optical connectors may be supported Figure 5-105‐10: CFP2 Optical Connector Position Offset ± 2mm Transmitter Receiver Module center Connector center

Appears in 1 contract

Samples: pdf4pro.com