Optional MOD_SELn Timing Requirements. The addition of the MOD_SELn input pin to CFP8 requires a new timing specification, not covered by reference [4]. A timing diagram is shown in Figure 2-4. The timing parameters are listed in Table 2-4. Host MOD_SELn Setup Time t_MOD_SELn_setup 100 - ms Before the rising edge of MDC clock cycle for the first preamble bit. Host MOD_SELn Hold Time t_MOD_SELn_hold 1 - ms After the falling edge of MDC clock cycle for the last ADDRESS/DATA bit.

Appears in 6 contracts

Samples: CFP Multi Source Agreement (Msa), Multi Source Agreement, CFP Multi Source Agreement (Msa)

AutoNDA by SimpleDocs

Optional MOD_SELn Timing Requirements. β€Œ 6 The addition of the MOD_SELn input pin to CFP8 requires a new timing specification, not covered by 7 reference [4]. A timing diagram is shown in Figure 2-4. The timing parameters are listed in Table 2-4. 8 Figure 2- 4: Optional MOD_SELn Timing Diagram 10 Table 2- 4: Optional MOD_SELn Timing Parameters Host MOD_SELn Setup Time t_MOD_SELn_setup 100 - ms Before the rising edge of MDC clock cycle for the first preamble bit. Host MOD_SELn Hold Time t_MOD_SELn_hold 1 - ms After the falling edge of MDC clock cycle for the last ADDRESS/DATA bit.