PCMS Control and Communications Sample Clauses

PCMS Control and Communications. Each PCMS shall be controlled and monitored by its own field controller. The field controller shall be a stand-alone microcomputer, which does not require continuous communication with PCMS control software to perform most PCMS control functions. The field controller shall be capable of communicating with another computer via both RS-232 and RJ45 Ethernet connections. 2.5.1 The PCMS field controller shall be able to receive instructions from and provide information to a computer containing PCMS control software using the following communication modes: 2.5.1.1 Remotely – Via direct (e.g., RS-232, RJ45 Ethernet, broadband modem such as Satellite, Cable, DSL. The system communications backbone, as well as all field modems or signal converters, shall provide the PCMS field controller with either an RS-232 signal having a baud rate between 2,400 bps and 115200 bps, and/or an RJ45 Ethernet 10/100Mbps signal. 2.5.1.2 Locally – Via direct connection with a laptop computer that is connected directly to the field controller using a null modem connection and a baud rate between 2,400 bps and 115200 bps. 2.5.1.3 Locally – Via a keypad/ touch screen and LCD interface.
AutoNDA by SimpleDocs
PCMS Control and Communications. The PCMS field controller shall be able to receive instructions from and provide information to a computer containing PCMS control software using the following communication modes: 3.21.1 Remotely – Via direct (e.g., RS-232, RJ45 Ethernet, broadband modem such as Satellite, Cable, DSL). The system communications backbone, as well as all field modems or signal converters, shall provide the PCMS field controller with either an RS-232 signal having a baud rate between 2,400 bps and 115200 bps, and/or an RJ45 Ethernet 10/100Mbps signal. 3.21.2 Locally – Via direct connection with a laptop computer that is connected directly to the field controller using a null modem connection and a baud rate between 2,400 bps and 115200 bps. 3.21.3 Locally – Via a keypad and LCD interface. This provides a way to add or remove message(s) from the PCMS list of installed messages, adjust luminosity to manual or automatic and monitor miscellaneous data like battery voltage, photocells reading, etc.

Related to PCMS Control and Communications

  • Agreement Administration and Communications A. Under this Agreement, either of the representatives of the Judicial Council identified below will monitor the Work and act as the Judicial Council’s liaisons with the Contractor: i. The Meeting Planner will be MPname. B. The Judicial Council may reallocate funds between the estimated amounts set forth in Exhibit G, without an Amendment to this Agreement, as long as the total amount to be paid under this Agreement does not exceed the Contract Amount. C. All requests and communications about the Work to be performed under this Agreement, including signing of any BEO’s, shall be made through the Meeting Planner or his or her designee or successor. D. Any Notice from the Contractor to the Judicial Council shall be delivered to the following address: MP name, Meeting Planner Judicial Council of California 000 Xxxxxx Xxxx Xxxxxx Xxx Xxxxxxxxx, XX 00000-0000 E. Notice to the Contractor shall be directed to the Contractor’s liaison, Attn, or his or her designee or successor, at the following address: Attn: Ktr DifferentAddress1 DifferentAddress2

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!